NASA NTRS · 19860000261
Spring-Loaded Joule-Thomson Valve
Abstract
Improved design reduces clogging and maintains constant pressure drop as flow rate varies. Spring-Loaded Joule-Thomson Valve pressure drop regulated by spring pushing stainless-steel ball against soft brass seat. Pressure drop remains nearly constant, regardless of helium flow rate and of any gas contaminants frozen on valve seat. Because springloaded J-T valve maintains constant pressure drop, upstream roomtemperature throttle valve adjusts flow rate precisely for any given upstream pressure. In addition, new valve relatively invulnerable to frozen gas contaminants, which clog fixed-orifice J-T valves.
Keep this discovery
Explore connections, maps & timelines
Jones, J. A., Britcliffe, M. J.. 1986-05-01. Spring-Loaded Joule-Thomson Valve. https://ntrs.nasa.gov/citations/19860000261
Cite the original work for its findings. Save a collection to share your selection of sources.