Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Experimental Considerations in Long-Baseline Neutrino Oscillation Measurements

Long-baseline neutrino oscillation experiments, which are among the largest neutrino experiments in the world, have extensive physics programs to make precision measurements of three-flavor oscillation parameters, search for physics beyond the Standard Model, and study neutrinos from astrophysical sources. In this article, experimental considerations, including oscillation phenomenology, detector and experiment design, and analysis strategies, are described, with a focus on the three-flavor oscillation measurements. Current and future experiments are discussed, and significant sources of systematic uncertainty, along with mitigation strategies, are emphasized as control of systematic uncertainty is critical for success in precise measurement of long-baseline oscillation parameters. This article is structured as a primer for those new to this area of experimental work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluating Precision of Measured Radionuclide Ambient Air Concentrations

According to AIRNET – Quality Assurance Project Plan for the Radiological Air Sampling Network, SOP-5140, Revision 2 (to become EPC-CP-PIP-5140): “The regulation 40 CFR Part 61.93 requires that the system be able to readily detect a dose of 1.0 mrem above background. Following statistical principles and assuming 95% confidence for such a measurement, we require that 95% of all measurements must fall within two standard deviations of the mean. This represents the minimum acceptable precision for decision making.” An independent assessment of the Rad-NESHAP program completed in early 2019 found that no documentation existed proving that the Airnet data meets the precision defined above. Therefore, to address this particular finding, Airnet concentration data was pulled from the Environmental Information Management (EIM), a cloud-based database maintained by Locus Technologies, for analysis.

54 ENVIRONMENTAL SCIENCES↗

Observation of Cabibbo-Suppressed Two-Body Hadronic Decays and Precision Mass Measurement of the Ω c 0 Baryon

The first observation of the singly Cabibbo-suppressed Ω c 0 → Ω − K + and Ω c 0 → Ξ − π + decays is reported, using proton-proton collision data at a center-of-mass energy of 13 TeV, corresponding to an integrated luminosity of 5.4 fb − 1 , collected with the LHCb detector between 2016 and 2018. The branching fraction ratios are measured to be B ( Ω c 0 → Ω − K + ) B ( Ω c 0 → Ω − π + ) = [ 6.08 ± 0.51 ( stat ) ± 0.40 ( syst ) ] % , B ( Ω c 0 → Ξ − π + ) B ( Ω c 0 → Ω − π + ) = [ 15.81 ± 0.87 ( stat ) ± 0.44 ( syst ) ± 0.16 ( ext ) ] % . In addition, using the Ω c 0 → Ω − π + decay channel, the Ω c 0 baryon mass is measured to be M ( Ω c 0 ) = 2695.28 ± 0.07 ( stat ) ± 0.27 ( syst ) ± 0.30 ( ext ) MeV , improving the precision of the previous world average by a factor of 4. © 2024 CERN, for the LHCb Collaboration 2024 CERN

Aaij, R. (ORCID:0000000305331952)↗

Gaussian mixture model clustering algorithms for the analysis of high-precision mass measurements

The development of the phase-imaging ion-cyclotron resonance (PI-ICR) technique for use in Penning trap mass spectrometry (PTMS) increased the speed and precision with which PTMS experiments can be carried out. In PI-ICR, data sets of the locations of individual ion hits on a detector are created showing how ions cluster together into spots according to their cyclotron frequency. Ideal data sets would consist of a single, 2D-spherical spot with no other noise, but in practice data sets typically contain multiple spots, non-spherical spots, or significant noise, all of which can make determining the locations of spot centers non-trivial. A method for assigning groups of ions to their respective spots and determining the spot centers is therefore essential for further improving precision and confidence in PI-ICR experiments. Here, we present the class of Gaussian mixture model (GMM) clustering algorithms as an optimal solution. We show that on simulated PI-ICR data, several types of GMM clustering algorithms perform better than other clustering algorithms over a variety of typical scenarios encountered in PI-ICR. The mass spectra of 163Gd, 163 mGd, 162 Tb, and 162 mTb measured using PI-ICR at the Canadian Penning trap mass spectrometer were checked using GMMs, producing results that were in close agreement with the previously published values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MUSE beamline calorimeter

The MUon Scattering Experiment (MUSE) was motivated by the proton radius puzzle arising from the discrepancy between muonic hydrogen spectroscopy and electron–proton measurements. The MUSE physics goals also include testing lepton universality, precisely measuring two-photon exchange contribution, and testing radiative corrections. MUSE addresses these physics goals through simultaneous measurement of high precision cross sections for electron–proton and muon–proton scattering using a mixed-species beam. The experiment will run at both positive and negative beam polarities. Measuring precise cross sections requires understanding both the incident beam energy and the radiative corrections. For this purpose, a lead-glass calorimeter was installed at the end of the beam line in the MUSE detector system. Here, in this article, we discuss the detector specifications, calibration and performance. We demonstrate that the detector performance is well reproduced by simulation, and meets experimental requirements.

Calorimeter↗

A Grand Scan of the pMSSM Parameter Space for Snowmass 2021

We present a flexible framework for interpretation of SUSY sensitivity studies for future colliders in terms of the phenomenological minimal supersymmetric standard model (pMSSM). We perform a grand scan of the pMSSM 19-dimensional parameter space that covers the accessible ranges of many collider scenarios, including electron, muon, and hadron colliders at a variety of center of mass energies. This enables comparisons of sensitivity and complementarity across different future experiments, including both colliders and precision measurements in the Cosmological and Rare Frontiers. The details of the scan framework are discussed, and the impact of future precision measurements on Higgs couplings, the anomalous muon magnetic moment, and dark matter quantities is presented. The next steps for this ongoing effort include performing studies with simulated events in order to quantitatively assess the sensitivity of selected future colliders in the context of the pMSSM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Operation of the Fast Neutron Coincidence Collar (FNCL) with a DD-Neutron Generator

For more than 30 years, the quantitative assay of the 235 U content of light water reactor fresh fuel assemblies relied on measuring coincidence neutrons from fissions induced by an Am(Li) neutron source using 3 He based detectors. The Fast Neutron Collar (FNCL) developed by the International Atomic Energy Agency (IAEA), replaces traditional 3 He proportional counters with an array of liquid scintillator detectors arranged about the fuel assembly to provide improved measurement precision and reduced sensitivity to gadolinium poison rods. The FNCL relies on Am(Li) neutron sources that are no longer commercially available. This work examines the replacement of Am(Li) sources with a commercial off the-shelf deuterium–deuterium (DD) neutron generator. In addition to mitigating supply concerns, the neutron generator offers advantages in measurement precision and potential automation of sequential passive/active neutron measurements. This report presents the initial performance results for both the integrated DD/FNCL and Am(Li)/FNCL assays of compact depleted uranium, low-enriched uranium, and highly enriched uranium standards along with an estimate of the expected performance for fresh fuel assemblies. A discussion of the design and operation of the “FNCL Analysis and Simulation Software” is also provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The muon g-2 experiment at Fermilab

The E989 collaboration has recently published the most precise measurement of the muon anomalous magnetic moment $a_\mu$ with an uncertainty of $0.46\,\mathrm{ppm}$. The new experimental world average of $a_\mu$ deviates by 4.2 standard deviations from the Standard Model prediction provided by the Muon g-2 Theory Initiative. Emerging results from ab-initio lattice QCD calculations for hadron-physics contributions allow to scrutinize this tantalizing hint for physics beyond the Standard Model for the first time in a three way comparison. To extract the value of $a_\mu$ a frequency comparison experiment is performed with spin-polarized muons confined in a superbly controlled electric and magnetic field environment. A measurement of the difference between the Larmor and the cyclotron frequency, the so-called anomalous spin precession frequency, is combined with a high-precision measurement of the magnetic field environment which is performed using nuclear magnetic resonance techniques. I discussed the most recent result of the Fermilab Muon g-2 experiment's first physics data run performed in 2018. I reported on the experimental improvements implemented for the subsequent science runs that will allow the collaboration to achieve the ultimate goal of $0.14\,\mathrm{ppm}$ uncertainty on $a_\mu$.

Fertl, Martin↗

Direct Subsurface Measurements through Precise Micro Drilling

Wellbore integrity is a significant problem in the U.S. and worldwide, which has serious adverse environmental and energy security consequences. Wells are constructed with a cement barrier designed to last about 50 years. Indirect measurements and models are commonly used to identify wellbore damage and leakage, often producing subjective and even erroneous results. The research presented herein focuses on new technologies to improve monitoring and detection of wellbore failures (leaks) by developing a multi-step machine learning approach to localize two types of thermal defects within a wellbore model, a prototype mechatronic system for automatically drilling small diameter holes of arbitrary depth to monitor the integrity of oil and gas wells in situ, and benchtop testing and analyses to support the development of an autonomous real-time diagnostic tool to enable sensor emplacement for monitoring wellbore integrity. Each technology was supported by experimental results. This research has provided tools to aid in the detection of wellbore leaks and significantly enhanced our understanding of the interaction between small-hole drilling and wellbore materials.

42 ENGINEERING↗

Nuclear charge densities in spherical and deformed nuclei: Toward precise calculations of charge radii

Precise measurements of atomic transitions affected by electron-nucleus hyperfine interactions offer sensitivity to explore basic properties of the atomic nucleus and study fundamental symmetries, including the search for new physics beyond the standard model of particle physics. Specifically, such measurements, augmented by atomic and nuclear calculations, will enable extraction of the higher-order radial moments of the charge-density distribution in spherical and deformed nuclei. The new data impose higher precision requirements on a theoretical description. The nuclear charge density is composed of the proton point distribution folded with the nucleonic charge distributions. The latter induce subtle relativistic corrections due to the coupling of nucleon magnetic moments with the nuclear spin-orbit density. Additional corrections come from the effect of center-of-mass projection. We assess the precision of nuclear charge density calculations by studying the behavior of relativistic and center-of-mass motion corrections to the second and fourth charge radial moments. Special attention has been paid to the magnetic spin-orbit density associated with the local variations of the spin-orbit current. The calculations for semimagic and open-shell nuclei are performed in the framework of self-consistent mean-field theory using quantified energy density functionals and density-dependent pairing forces. We used the general expression for the spin-orbit form factor that is valid for spherical and deformed nuclei. We studied the impact of various correction terms on the charge radii, fourth radial moments, diffraction radii, and surface thickness of spherical and deformed nuclei. The spin-orbit corrections to charge radial moments and surface thickness show strong shell fluctuations which can make an appreciable effect when aiming at high-precision predictions of isotopic shifts. The inclusion of relativistic and center-of-mass corrections impacts the quality of energy density functionals optimized to charge radii data. To establish reliable constraints on the existence of new forces from isotope shift measurements, precise calculations of nuclear charge densities of deformed nuclei are needed. The proper inclusion of the spin-orbit charge density and other correction terms is essential when aiming at extraction of subtle effects which become particularly visible in isotopic trends. It is also important when developing high-quality nuclear energy density functionals optimized using heterogeneous datasets involving absolute charge radii, differential charge radii, and charge form factor properties deduced from electron-scattering data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative 2D thermometry in turbulent sooting non-premixed flames using filtered Rayleigh scattering

This paper demonstrates the application of a thermometry method in turbulent sooting non-premixed flames using filtered Rayleigh scattering (FRS). Fuel tailoring is used to establish a specific C 2 H 2 -based fuel mixture such that temperature can be determined accurately by a single FRS measurement over the entirety of mixture fraction space, or equivalently, for all relevant thermo-chemical states. Evaluation is performed in a hierarchy of flows to establish measurement precision and accuracy. Initial assessments in a series of heated fuel mixtures; non-sooting, near-adiabatic flat flames; and laminar non-premixed sooting flames show accuracy of the approach over a full range of expected temperatures and high single-shot measurement precision (e.g., 65 < <#comment/> S N R < <#comment/> 80 ) for temperatures between 1900 and 2200 K. Subsequently, 2D temperature measurements are evaluated in a turbulent non-premixed sooting flame. For the current fuel mixture, the local mixture-averaged Rayleigh scattering cross section is nearly constant over all composition space, and thus traditional laser Rayleigh scattering (LRS) is used as a measurement standard in the absence of soot. The results show excellent agreement between the proposed FRS thermometry approach and LRS in non-sooting regions. In the presence of soot, the proposed FRS-based approach shows no signs of interference. In addition, 2D temperature imaging shows high SNR (60–74) over all temperature conditions. Thus, we believe the proposed methodology successfully provides a high-resolution 2D temperature method under turbulent sooting flame conditions.

Pu, Jinpeng↗

Measurements of the charge ratio and polarization of cosmic-ray muons with the Super-Kamiokande detector

We present the results of the charge ratio (𝑅) and polarization (𝑃$^{𝜇}_{0}$) measurements using decay electron events collected between September 2008 and June 2022 with the Super-Kamiokande detector. Because of its underground location and long operation, we are able to perform high-precision measurements by accumulating cosmic-ray muons. We measured the muon charge ratio to be 𝑅 = 1.32 ± 0.02⁢(stat +syst) at 𝐸 𝜇 ⁢cos⁡𝜃 Zenith = 0.7$^{+0.3}_{−0.2}$ TeV, where 𝐸 𝜇 is the muon energy and 𝜃 Zenith is the zenith angle of incoming cosmic-ray muons. This result is consistent with the Honda flux model while indicating a tension with the 𝜋⁢𝐾 model of 1.9⁢𝜎. We also measured the muon polarization at the production location to be 𝑃$^{𝜇}_{0}$ = 0.52 ± 0.02 (stat+syst) at the muon momentum of 0.9$^{+0.6}_{−0.1}$ TeV/𝑐 at the surface of the mountain; this also suggests a tension with the Honda flux model of 1.5⁢𝜎. This is the most precise measurement ever to experimentally determine the cosmic-ray muon polarization near 1 TeV/𝑐. These measurement results are useful to improve atmospheric neutrino simulations.

Atmospheric neutrino oscillations↗

Searching for the origin of the rare-earth peak with precision mass measurements across Ce–Eu isotopic chains

A nuclear mass survey of rare-earth isotopes has been conducted with the Canadian Penning Trap mass spectrometer using the most neutron-rich nuclei thus far extracted from the CARIBU facility. Here, we present a collection of 12 nuclear masses determined with a precision of ≤ 10 keV/c 2 for Z = 58-63 nuclei near N = 100. Independently, a detailed study exploring the role of nuclear masses in the formation of the r-process rare-earth abundance peak has been performed. Employing a Markov chain Monte Carlo (MCMC) technique, mass predictions of lanthanide isotopes have been made which uniquely reproduce the observed solar abundances near A = 164 under three distinct astrophysical outflow conditions. We demonstrate that the mass surface trends thus far mapped out by our measurements are most consistent with MCMC mass predictions given an r process that forms the rare-earth peak during an extended (n, γ) ⇌ (γ, n) equilibrium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Search for a heavy neutral lepton with the MAGNETO-𝜈 experiment using 241 Pu 𝛽 − decays

The MAGNETO-𝜈 experiment searches for keV-scale heavy neutral leptons (HNLs) through precise measurements of the 𝛽 − -decay spectrum of 241 Pu. We present spectra comprising a total of 194 million 𝛽 − decays recorded using decay energy spectrometry with metallic magnetic calorimeters, representing the most statistically precise measurement of 241 Pu 𝛽 − decay to date. The 𝛽-endpoint energy was determined using 𝛾 rays and x-rays from an external 133 Ba calibration source, yielding 𝑄 𝛽 = 22.273⁢ (33) ⁢keV. The measured spectrum shows no statistically significant deviation from the allowed 𝛽-decay model. From a subset of the high-statistics data, we set an upper limit on the mixing of an 11.5-keV HNL with the electron neutrino, |𝑈 𝑒⁢4 | 2 < 1.31 × 10 −3 at the 95% confidence level.

A ≥ 220↗

Simultaneous extraction of the weak radius and the weak mixing angle from parity-violating electron scattering on 12 C

We study the impact of nuclear structure uncertainties on a measurement of the weak charge of 12 C at the future Mainz Energy Recovering Superconducting Accelerator (MESA) facility in Mainz. Information from a large variety of nuclear models, accurately calibrated to the ground-state properties of selected nuclei, suggest that a 0.3% precision measurement of the parity-violating asymmetry at forward angles will not be compromised by nuclear structure effects, thereby allowing a world-leading determination of the weak charge of 12 C . Furthermore, we show that a combination of measurements of the parity-violating asymmetry at forward and backward angles for the same electron-beam energy can be used to extract information on the nuclear weak charge distribution. We conclude that a 0.34% precision on the weak radius of 12 C may be achieved by performing a 3% precision measurement of the parity-violating asymmetry at backward angles.

Electroweak interaction↗

Electroweak, QCD and flavour physics studies with ATLAS data from Run 2 of the LHC

A of precision measurements sensitive to electroweak, QCD and quark-flavour effects performed by the ATLAS Collaboration at the Large Hadron Collider is reported. The measurements are predominantly performed on proton–proton ( p p ) collision data recorded at a centre-of-mass energy of 13 TeV taken from 2015 to 2018, with an integrated luminosity of up to 140 fb−1, with some results based on p p and Pb+Pb data recorded at lower nucleon centre-of-mass energies. The results cover a wide range of topics, from strong production of particles at low energies and the spectroscopy of hadrons to perturbative QCD with hadronic jets and electroweak and strong production of single and multiple vector bosons. They provide precise measurements of fundamental constants and stringent tests of the Standard Model with unprecedented precision and in energy ranges never explored before. They are also used to explore the proton structure and to perform model-independent searches for new physics.

Source record↗

Measurement of U 238 ( n , n ' γ ) cross section data and their impact on reaction models

A better knowledge of (n,xn) reaction cross sections is important for both reaction modeling and energy applications. This article focuses on inelastic scattering of neutrons off 238 U for which improvements are needed to better constrain evaluations and solve inconsistencies in nuclear power reactor calculations. A new precise measurement of (n,xnγ) reaction cross sections on 238 U has been performed at the GELINA (Geel Electron LINear Accelerator) neutron facility operated by EC-JRC-Geel (Belgium) with the GRAPhEME (GeRmanium array for Actinides PrEcise MEasurements) setup. The prompt γ-ray spectroscopy method coupled to time-of-flight measurements is used to extract (n,xnγ) cross section values which can be further combined to infer the total neutron inelastic scattering cross section. Cross section data for 18 γ transitions (five never measured before) are presented and compared to the data in the literature. Here, emphasis is especially given to the uncertainty determination to produce partial cross section data as accurate as possible. Due to intrinsic limitations of the experimental method, the use of additional nuclear structure information coupled with theoretical modeling is required to determine the total (n, n') cross section over the whole neutron energy range. We have investigated modeling aspects of the 238 U(n,n'γ) cross sections related to the description of compound nucleus and preequilibirum mechanisms as well as the discrete part of nuclear structure. Through comparison between experimental and calculated (n,n'γ) cross sections, we pinpoint inaccuracies in the description of specific reaction mechanisms and challenge recently implemented models. This helps improving the whole modeling of the (n, n') reaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dark matter detection, Standard Model parameters and Intermediate Scale Supersymmetry

The vanishing of the Higgs quartic coupling at a high energy scale may be explained by Intermediate Scale Supersymmetry, where supersymmetry breaks at (10 9 -10 12 ) GeV. The possible range of supersymmetry breaking scales can be narrowed down by precise measurements of the top quark mass and the strong coupling constant. On the other hand, nuclear recoil experiments can probe Higgsino or sneutrino dark matter up to a mass of 1012 GeV. We derive the correlation between the dark matter mass and precision measurements of standard model parameters, including supersymmetric threshold corrections. The dark matter mass is bounded from above as a function of the top quark mass and the strong coupling constant. The top quark mass and the strong coupling constant are bounded from above and below respectively for a given dark matter mass. We also discuss how the observed dark matter abundance can be explained by freeze-out or freeze-in during a matter-dominated era after inflation, with the inflaton condensate being dissipated by thermal effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗