Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIGHT AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Performance of Hamamatsu VUV4 SiPMs for detecting liquid argon scintillation

Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is technically challenging. In this paper, we characterized the performance of Hamamatsu VUV4 silicon photomultipliers (SiPMs) for detecting VUV argon scintillation light without wavelength shifting. Using a customized cryogenic amplifier design, we operated two models of VUV4 SiPMs inside liquid argon and thoroughly examined their direct sensitivities to liquid argon scintillation. In addition to describing their cryogenic performance, we measured a photon detection efficiency of 14.7 +1.1 -2.4 % and 17.2 +1.6 -3.0 % at 128 nm for these two VUV4 models for operation at 4 V of overvoltage, with the main uncertainty arising from the SiPM reflectivity for VUV light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Angular dependent light emission from planar waveguides

We have investigated the angular dependence of amplified spontaneous emission (ASE) and laser emission from an asymmetric and free-standing polymer thin films doped with rhodamine 6G, which is transversely pumped by a pulsed Nd:YAG laser. A semi-leaky waveguide or quasi-waveguide structure has been developed by spin coating technique. In these waveguides, the light was confined by the film/air-film/glass substrate interfaces. At the film/substrate interface, a portion of light will reflect back into the film (guided mode) and the remaining refracted to the substrate resulting in cutoff modes. A blue-shift in ASE has been observed when the pump power was increased from 8 to 20 mW allowing a limited range of tuning of emission wavelength. To study the directionality of the ASE from the waveguide, we have measured the output intensity and FWHM of emission spectra as a function of viewing angle (θ) from the plane parallel to film. From the detailed examination of the output emission spectra, as +θ increases from 0° there has been an initial decrease in output intensity, but at a particular angle ≈10° an increase in output intensity was observed. This additional peak in output intensity as +θ is a clear indication of coexistence of the cutoff mode. We also present a compact solid-state laser based on leaky mode propagation from the dye-doped polymer free-standing film (∼50 μm thickness) waveguide. The partial reflections from the broad lateral surfaces of the free-standing films provided the optical feedback for the laser emission with high directionality. For a pump power of 22 mW, an intense line with FWHM <0.2 nm was observed at 578 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of a low noise detection circuit for probing the structure of damage cascades with IBIC

Optimal detector / pre-amplifier combinations have been identified for the use of light ion IBIC (ion beam induced charge) to probe the physical structure of electrically active defects in damage cascades caused by heavy ion implantation. The ideal detector must have a sufficiently thin dead layer that incident ions will produce the majority of damage cascades in the depletion region of the detector rather than the dead layer. Detector and circuit noise must be low enough to detect the implantation of a single heavy ion as well as the decrease in the light ion IBIC signal caused by Shockley-Read-Hall recombination when the beam scans regions of the detector damaged by the heavy ion. The IBIC signals from three detectors irradiated with 750 keV He⁺ ions are measured with commercial and bespoke charge sensitive pre-amplifiers to identify the combination with the lowest noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Amplified response of cavity-coupled quantum-critical systems

A quantum critical point develops when matter undergoes a continuous transformation between distinct ground states at absolute zero. It hosts pronounced quantum fluctuations, which render the system highly susceptible to external perturbations. While light-matter coupling has rapidly moved forward as a means to probe and control quantum materials, the capacity of quantum critical fluctuations in the photon-mediated responses has been largely unexplored. Here we advance the notion that directly coupling a quantum critical mode to a quantized cavity field dramatically facilitates the realization of the elusive superradiant phase transition in equilibrium, circumventing at once the key obstacles that have prevented its attainment in spite of decades of pursuit. The superradiant phase transition develops far below the ultrastrong regime of light-matter couplings, and the transition is accompanied by the light-matter hybrid system showing strongly enhanced intrinsic squeezing and amplified quantum Fisher information. We also identify candidate cavity quantum materials platforms for validating the proposed effect. Our findings suggest a general principle by which quantum criticality amplifies the response to cavity photons. They also demonstrate that cavity coupling accesses the elevated quantum entanglement of the underlying matter at quantum criticality, thereby pointing to a pathway towards realizing the potential of highly collective quantum materials to expand the capacities of quantum information science.

Sur, Shouvik [Rice Univ., Houston, TX (United Stat↗

Controllable X-ray Pulse Trains from Enhanced Self-Amplified Spontaneous Emission

We report the demonstration of optical compression of an electron beam and the production of controllable trains of femtosecond, soft x-ray pulses with the Linac Coherent Light Source (LCLS) freeelectron laser (FEL). This is achieved by enhanced self-amplified spontaneous emission with a 2 μm laser and a dechirper device. Optical compression was achieved by modulating the energy of an electron beam with the laser and then compressing with a chicane, resulting in high current spikes on the beam which we observe to lase. A dechirper was then used to selectively control the lasing region of the electron beam. Field autocorrelation measurements indicate a train of pulses, and we find that the number of pulses within the train can be controlled (from 1 to 5 pulses) by varying the dechirper position and undulator taper. These results are a step toward attosecond spectroscopy with x-ray FELs as well as future FEL schemes relying on optical compression of an electron beam.

Duris, Joseph P↗

Detection of two-mode compression and degree of entanglement in continuous variables in parametric scattering of light

Generation of 'twin beams' (of light with two-mode compression) in single-pass optical parametric amplifier (a crystal with a nonzero quadratic susceptibility) is considered. Radiation at the output of the nonlinear crystal is essentially multimode, which raises the question about the effect of the detection volume on the extent of suppression of noise from the difference photocurrent of the detectors. In addition, the longitudinal as well as transverse size of the region in which parametric transformation takes place is of fundamental importance. It is shown that maximal suppression of noise from difference photocurrent requires a high degree of entanglement of two-photon light at the outlet of the parametric amplifier, which is defined by Federov et al. [Phys. Rev. A 77, 032336 (2008)] as the ratio of the intensity distribution width to the correlation function width. The detection volume should be chosen taking into account both these quantities. Various modes of single-pass generation of twin beams (noncollinear frequency-degenerate and collinear frequency-nondegenerate synchronism of type I, as well as collinear frequency-degenerate synchronism of type II) are considered in connection with the degree of entanglement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of Hamamatsu VUV4 SiPM Performance for Liquid Argon Scintillation

Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is technically challenging. In this article, we characterized the performance of Hamamatsu VUV4 silicon photomultipliers (SiPMs) for detecting VUV argon scintillation light without wavelength shifting. Here, using a customized cryogenic amplifier design, we operated two models of VUV4 SiPMs inside liquid argon and thoroughly examined their direct sensitivities to liquid argon scintillation. In addition to describing their cryogenic performance, we measured a photon detection efficiency of 14.7+1.1–2.4% and 17.2+1.6–3.0% at 128 nm for these two VUV4 models for operation at 4 V of overvoltage, with the main uncertainty arising from the SiPM reflectivity for VUV light.

Pershing, Teal↗

Hot Raman amplification

A parameter regime is identified for Raman amplification at high temperatures, where deleterious laser–plasma instabilities that limit current amplification experiments are avoided, yet sufficient gain for an effective power amplifier is attained. Furthermore, calculations and kinetic simulations show that even at high temperatures, an amplifier is able to satisfy the criteria set forth to present a proof-of-principle system scalable to high powers, where energy transfer efficiencies are ≥30%, intensity gains are ≥10, and output intensities are ≥100× the pump intensity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single photon detection and sub-nanosecond timing resolution with RCA C31034 photomultiplier

The very high quantum efficiencies and low dark count rates achieved with selected RCA C31034 photomultipliers make them attractive candidates for single photoelectron fast timing experiments. Single photoelectron plateau counting and a timing resolution of 0.60 nsec (FWHM) were obtained using fast amplifiers, constant fraction timing discriminators, and a pulsed light emitting diode. A redesign of the C31034 incorporating features of the very fast C31024 is suggested to yield even better timing resolution.

Reisse, R.↗

Metal-dielectric-CNT nanowires for surface-enhanced Raman spectroscopy

A sensor with a substrate includes nanowires extending vertically from the substrate, a hafnia coating on the nanowires that provides hafnia coated nanowires, and a noble metal coating on the hafnia coated nanowires. The top of the hafnia and noble metal coated nanowires bent onto one another to create a canopy forest structure. There are numerous randomly arranged holes that let through scattered light. The many points of contact, hot spots, amplify signals. The methods include the steps of providing a Raman spectroscopy substrate, introducing nano crystals to the Raman spectroscopy substrate, growing a forest of nanowires from the nano crystals on the Raman spectroscopy substrate, coating the nanowires with hafnia providing hafnia coated nanowires, and coating the hafnia coated nanowires with a noble metal or other metal.

36 MATERIALS SCIENCE↗

1.54 micron Emission from Erbium implanted GaN for Photonic Applications

The development of efficient and compact light sources operating at 1.54 micron is of enormous importance for the advancement of new optical communication systems. Erbium (1%) doped fiber amplifiers (EDFA's) or semiconductor lasers are currently being employed as near infrared light sources. Both devices, however, have inherent limitations due to their mode of operation. EDFA's employ an elaborate optical pumping scheme, whereas diode lasers have a strongly temperature dependent lasing wavelength. Novel light emitters based on erbium doped III-V semiconductors could overcome these limitations. Er doped semiconductors combine the convenience of electrical excitation with the excellent luminescence properties of Er(3+) ions. Electrically pumped, compact, and temperature stable optoelectronic devices are envisioned from this new class of luminescent materials. In this paper we discuss the potential of Er doped GaN for optoelectronic applications based on temperature dependent photoluminescence excitation studies.

Thaik, Myo↗

Probing Plasmonic Near-Fields in Oxide-Modified Aluminum Nanocubes Using Photon-Induced Near-Field Electron Microscopy

Plasmonic nanoparticles generate strong electric fields near their surface upon photoexcitation, enabling applications in sensing, spectroscopy, and photocatalysis. Electron microscopy techniques – such as cathodoluminescence and electron energy loss spectroscopy – have been leveraged to produce nanoscale maps of localized surface plasmon (LSP) modes. More recently, photon-induced near-field electron microscopy (PINEM) has emerged as a powerful technique for imaging evanescent near-fields generated by ultrafast laser excitation. In this work, we employ PINEM within an ultrafast electron microscope, complemented by numerical calculations to investigate how optical polarization, surface modification, and light intensity affect the evanescent fields associated with LSPs on oxide-modified aluminum nanocubes. Polarization control of the incident light field enables spatial mapping of the nanocube’s LSPs at the single particle level. Systematic variation of the oxide layer thickness reveals that increased coating thickness correlates with a stronger PINEM signal and a greater energy gain of probing electrons. Additionally, higher light intensities at fixed polarization and oxide coating further amplify the PINEM signal. These findings demonstrate the utility of PINEM as a high-resolution technique for optical near-field imaging and spectroscopy of single plasmonic nanoparticles. The ability to probe single particle behavior offers new opportunities for advancing the design and characterization of nanophotonic and plasmonic materials.

PINEM↗

Trapping induced nonlinear behavior of backward stimulated Raman scattering in multi-speckled laser beams

In inertial confinement fusion experiments, stimulated Raman scattering (SRS) occurs when electron density fluctuations are amplified resonantly by the incident laser beams and scattered light. These beams comprise several thousands of individual laser speckles. We have found in single-speckle studies that electron trapping lowers the threshold intensity for SRS onset to a value below that from linear theory and enhances scattering. The trapping-induced plasma-wave frequency shift leads to wave-front bowing and filamentation processes that saturate SRS and limit scattering within a speckle. With large-scale simulations, we have now examined how laser speckles interact with one another through three-dimensional (3D) particle-in-cell (PIC) simulations of two interacting speckles and 2D PIC simulations of ensembles of laser speckles (hundreds of speckles). Our work shows that kinetic trapping physics also governs the onset and saturation of SRS in ensembles of speckles. Speckles interact in a manner that is nonlinear and nonlocal: An intense speckle can destabilize its neighbors through transport of hot electrons and SRS waves, resulting in enhanced emission of particles and waves that, in turn, act upon the original speckle. In this manner, speckles below threshold when in isolation can be above the threshold in multi-speckled beams under conditions for laser-driven fusion experiments at the National Ignition Facility (NIF) and ensembles of speckles are thus found to collectively lower the SRS onset threshold. Simulations of the hohlraum interior where laser beams overlap show that multi-speckled laser beams at low average intensity (a few times 10{sup 14} W/cm{sup 2}) have correspondingly lower thresholds for enhanced SRS and that the sub-ps bursts of SRS saturate through trapping induced nonlinearities. Because of electron trapping effects, SRS reflectivity grows slowly with average laser intensity. While SRS reflectivity saturates under NIF conditions, SRS hot electron energy increases with increasing laser intensity and may contribute to capsule preheat.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser and optical transport line for laser-based ion beam diagnostics and control in the SNS linear accelerator

We report our recent upgrade of the laser and optical transport line for the laser-based ion beam diagnostics (laser wire) system at the linear accelerator (linac) of the Spallation Neutron Source (SNS). A new light source based on diodepumped solid-state laser amplifiers has been developed to provide near diffraction-limited laser beam with a variety of pulse structures. The free-space optical transport line has been modified to include image relay optics with remote control, which greatly improved the laser beam quality and position stability at individual measurement stations. The upgraded system enables novel beam diagnostics/control capabilities including longitudinal profile measurement and high-energy proton beam extraction from the SNS linac.

Liu, Yun↗

National Ignition Facility: Shot Operations Plan

This document identifies the policies and general procedures necessary to perform and support routine shot operations in the NIF Facility. Shot Operations are defined as those activities directly related to or supporting the operation of the NIF Main Laser System, Precision Diagnostic System (PDS), Target Chamber (TC), and associated systems located on the NIF. Operations include delivery of low-power laser light through to the firing of the main laser amplifiers, operation of the beampath and associated utilities, target positioners and diagnostics, and the various computer control systems. Construction and maintenance activities are not covered here, except as they interface to ongoing operations. This document, in conjunction with the NIF Operations Management Plan and NIF Maintenance Plan, satisfies the requirements for a Conduct of Operations.

42 ENGINEERING↗

Polarimetry Microlensing of Close-in Planetary Systems

A close-in giant planetary (CGP) system has a net polarization signal whose value varies depending on the orbital phase of the planet. This polarization signal is either caused by the stellar occultation or by reflected starlight from the surface of the orbiting planet. When the CGP system is located in the Galactic bulge, its polarization signal becomes too weak to be measured directly. One method for detecting and characterizing these weak polarization signatures due to distant CGP systems is gravitational microlensing. In this work, we focus on potential polarimetric observations of highly magnified microlensing events of CGP systems. When the lens is passing directly in front of the source star with its planetary companion, the polarimetric signature caused by the transiting planet is magnified. As a result, some distinct features in the polarimetry and light curves are produced. In the same way, microlensing amplifies the reflection-induced polarization signal. While the planet-induced perturbations are magnified whenever these polarimetric or photometric deviations vanish for a moment, the corresponding magnification factor of the polarization component(s) is related to the planet itself. Finding these exact times in the planet-induced perturbations helps us to characterize the planet. In order to evaluate the observability of such systems through polarimetric or photometric observations of high-magnification microlensing events, we simulate these events by considering confirmed CGP systems as their source stars and conclude that the efficiency for detecting the planet-induced signal with the state-of-the-art polarimetric instrument (FORS2/VLT) is less than 0.1%. Consequently, these planet-induced polarimetry perturbations can likely be detected under favorable conditions by the high-resolution and short-cadence polarimeters of the next generation.

79 ASTRONOMY AND ASTROPHYSICS↗

On a photon-counting array using the Fairchild CCD-201

The evaluation of certain performance parameters of the Fairchild CCD 201 and the proposed method of operation of an electron bombarded charge coupled device are described. Work in progress on the evaluation of the parameters relevant to remote, low noise operation is reported. These tests have been conducted using light input. The video data from the CCD are amplified, digitized, stored in a minicomputer memory, and then recorded on magnetic tape for analyzing. The device will be used in an array of sensors in the aperture plane of a telescope to discriminate between photoelectron events, and in the focal plane operating at single photoelectron sensitivity at a minimum of blooming and lag.

Currie, D. G.↗

Solid-state image sensor with focal-plane digital photon-counting pixel array

A photosensitive layer such as a-Si for a UV/visible wavelength band is provided for low light level imaging with at least a separate CMOS amplifier directly connected to each PIN photodetector diode to provide a focal-plane array of NxN pixels, and preferably a separate photon-counting CMOS circuit directly connected to each CMOS amplifier, although one row of counters may be time shared for reading out the photon flux rate of each diode in the array, together with a buffer memory for storing all rows of the NxN image frame before transfer to suitable storage. All CMOS circuitry is preferably fabricated in the same silicon layer as the PIN photodetector diode for a monolithic structure, but when the wavelength band of interest requires photosensitive material different from silicon, the focal-plane array may be fabricated separately on a different semiconductor layer bump-bonded or otherwise bonded for a virtually monolithic structure with one free terminal of each diode directly connected to the input terminal of its CMOS amplifier and digital counter for integration of the photon flux rate at each photodetector of the array.

Fossum, Eric R.↗