Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTOPE RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The radioactive nuclei 26 Al and 60 Fe in the Cosmos and in the solar system

The cosmic evolution of the chemical elements from the Big Bang to the present time is driven by nuclear fusion reactions inside stars and stellar explosions. A cycle of matter recurrently re-processes metal-enriched stellar ejecta into the next generation of stars. The study of cosmic nucleosynthesis and this matter cycle requires the understanding of the physics of nuclear reactions, of the conditions at which the nuclear reactions are activated inside the stars and stellar explosions, of the stellar ejection mechanisms through winds and explosions, and of the transport of the ejecta towards the next cycle, from hot plasma to cold, star-forming gas. Due to the long timescales of stellar evolution, and because of the infrequent occurrence of stellar explosions, observational studies are challenging, as they have biases in time and space as well as different sensitivities related to the various astronomical methods. Here, we describe in detail the astrophysical and nuclear-physical processes involved in creating two radioactive isotopes useful in such studies, 26 Al and 60 Fe. Due to their radioactive lifetime of the order of a million years, these isotopes are suitable to characterise simultaneously the processes of nuclear fusion reactions and of interstellar transport. We describe and discuss the nuclear reactions involved in the production and destruction of 26 Al and 60 Fe, the key characteristics of the stellar sites of their nucleosynthesis and their interstellar journey after ejection from the nucleosynthesis sites. This allows us to connect the theoretical astrophysical aspects to the variety of astronomical messengers presented here, from stardust and cosmic-ray composition measurements, through observation of γ rays produced by radioactivity, to material deposited in deep-sea ocean crusts and to the inferred composition of the first solids that have formed in the Solar System. We show that considering measurements of the isotopic ratio of 26 Al to 60 Fe eliminate some of the unknowns when interpreting astronomical results, and discuss the lessons learned from these two isotopes on cosmic chemical evolution. This review paper has emerged from an ISSI-BJ Team project in 2017–2019, bringing together nuclear physicists, astronomers, and astrophysicists in this inter-disciplinary discussion.

79 ASTRONOMY AND ASTROPHYSICS↗

Carbon isotope fractionation by an ancestral rubisco suggests that biological proxies for CO 2 through geologic time should be reevaluated

The history of Earth’s carbon cycle reflects trends in atmospheric composition convolved with the evolution of photosynthesis. Fortunately, key parts of the carbon cycle have been recorded in the carbon isotope ratios of sedimentary rocks. The dominant model used to interpret this record as a proxy for ancient atmospheric CO 2 is based on carbon isotope fractionations of modern photoautotrophs, and longstanding questions remain about how their evolution might have impacted the record. Therefore, we measured both biomass (ε p ) and enzymatic (ε Rubisco ) carbon isotope fractionations of a cyanobacterial strain ( Synechococcus elongatus PCC 7942) solely expressing a putative ancestral Form 1B rubisco dating to ≫1 Ga. This strain, nicknamed ANC, grows in ambient pCO 2 and displays larger ε p values than WT, despite having a much smaller ε Rubisco (17.23 ± 0.61‰ vs. 25.18 ± 0.31‰, respectively). Surprisingly, ANC ε p exceeded ANC ε Rubisco in all conditions tested, contradicting prevailing models of cyanobacterial carbon isotope fractionation. Such models can be rectified by introducing additional isotopic fractionation associated with powered inorganic carbon uptake mechanisms present in Cyanobacteria, but this amendment hinders the ability to accurately estimate historical pCO 2 from geological data. Understanding the evolution of rubisco and the CO 2 concentrating mechanism is therefore critical for interpreting the carbon isotope record, and fluctuations in the record may reflect the evolving efficiency of carbon fixing metabolisms in addition to changes in atmospheric CO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development towards stable chlorine isotope measurements of astromaterials using the modified Middleton source of an accelerator mass spectrometer

The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35 Cl and 37 Cl. Chlorine isotope variations (reported as δ 37 Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) are documented to exceed 80‰ between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history. The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements. This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ 37 Cl measurements using the modified Middleton ion source of an existing accelerator mass spectrometer. For samples with as little as 1 μg Cl–the equivalent of 2–4 mm 3 of a typical lunar rock sample–the average cathode accuracy is ~1‰. Finally, cathode reproducibility is typically ~1‰ (2σ) for samples with at least 10 μg of Cl, increasing to ~3–6‰ for aliquots with ~1–2 μg Cl, similar to published SIMS results and sufficient to study astromaterials from the Moon, Mars, or 4 Vesta, which have tens of ‰ observed variations.

07 ISOTOPE AND RADIATION SOURCES↗

Evidence of both molecular cloud and fluid chemistry in Ryugu regolith

The sulfur chemistry of (162173) Ryugu particles can be a powerful tracer of molecular cloud chemistry and small body processes, but it has not been well explored. We report identification of organosulfurs and a sulfate grain in two Ryugu particles, A0070 and A0093. The sulfate grain shows oxygen isotope ratios (δ 17 O = -11.0 ± 4.3 per mil, δ 18 O = -7.8 ± 2.3 per mil) that are akin to silicates in Ryugu but exhibit mass-independent sulfur isotopic fractionation (Δ 33 S = +5 ± 2 per mil). A methionine-like coating on the sulfate grain is isotopically anomalous (δ 15 N = +62 ± 2 per mil). Both the sulfate and organosulfurs can simultaneously form and survive during aqueous alteration within Ryugu’s parent body, under reduced conditions, low temperature, and a pH >7 in the presence of N-rich organic molecules. This work extends the heliocentric zone where anomalous sulfur, formed by selective photodissociation of H 2 S gas in the molecular cloud, is found.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Water isotopes, climate variability, and the hydrological cycle: recent advances and new frontiers

Abstract The hydrologic cycle is a fundamental component of the climate system with critical societal and ecological relevance. Yet gaps persist in our understanding of water fluxes and their response to increased greenhouse gas forcing. The stable isotope ratios of oxygen and hydrogen in water provide a unique opportunity to evaluate hydrological processes and investigate their role in the variability of the climate system and its sensitivity to change. Water isotopes also form the basis of many paleoclimate proxies in a variety of archives, including ice cores, lake and marine sediments, corals, and speleothems. These records hold most of the available information about past hydrologic variability prior to instrumental observations. Water isotopes thus provide a ‘common currency’ that links paleoclimate archives to modern observations, allowing us to evaluate hydrologic processes and their effects on climate variability on a wide range of time and length scales. Building on previous literature summarizing advancements in water isotopic measurements and modeling and describe water isotopic applications for understanding hydrological processes, this topical review reflects on new insights about climate variability from isotopic studies. We highlight new work and opportunities to enhance our understanding and predictive skill and offer a set of recommendations to advance observational and model-based tools for climate research. Finally, we highlight opportunities to better constrain climate sensitivity and identify anthropogenically-driven hydrologic changes within the inherently noisy background of natural climate variability.

Dee, Sylvia (ORCID:000000022140785X)↗

Chalcogen isotopes reveal limited volatile contribution from late veneer to Earth

The origin of Earth’s volatile elements is highly debated. Comparing the chalcogen isotope ratios in the bulk silicate Earth (BSE) to those of its possible building blocks, chondritic meteorites, allows constraints on the origin of Earth’s volatiles; however, these comparisons are complicated by potential isotopic fractionation during protoplanetary differentiation, which largely remains poorly understood. Using first-principles calculations, we find that core-mantle differentiation does not notably fractionate selenium and tellurium isotopes, while equilibrium evaporation from early planetesimals would enrich selenium and tellurium in heavy isotopes in the BSE. The sulfur, selenium, and tellurium isotopic signatures of the BSE reveal that protoplanetary differentiation plays a key role in establishing most of Earth’s volatile elements, and a late veneer does not substantially contribute to the BSE’s volatile inventory.

58 GEOSCIENCES↗

Stable isotopes contain substantial additive information about terrestrial carbon and water cycling

Abstract Stable isotope ratios of H ( δ 2 H ), O ( δ 18 O), and C ( δ 13 C) are linked to key biogeochemical processes of the water and carbon cycles; however, the degree to which isotope-associated processes are reflected in macroscale ecosystem flux observations remains unquantified. Here through formal information assessment, new measurements of δ 13 C of net ecosystem exchange ( NEE ) as well as δ 2 H and δ 18 O of latent heat ( LH ) fluxes across the United States National Ecological Observation Network (NEON) are used to determine conditions under which isotope measurements are informative of environmental exchanges. We find all three isotopic datasets individually contain comparable amounts of information about NEE and LH fluxes as wind speed observations. Such information from isotope measurements, however, is largely unique. Generally, δ 13 C provides more information about LH as aridity increases or mean annual precipitation decreases. δ 2 H provides more information about LH as temperatures or mean annual precipitation decreases, and also provides more information about NEE as temperatures decrease. Overall, we show that the stable isotope datasets collected by NEON contribute non-trivial amounts of new information about bulk environmental fluxes useful for interpreting biogeochemical and ecohydrological processes at landscape scales. However, the utility of this new information varies with environmental conditions at continental scales. This study provides an approach for quantifying the value adding non-traditional sensing approaches to environmental monitoring sites and the patterns identified here are expected to aid in modeling and data interpretation efforts focused on constraining carbon and water cycles’ mechanisms.

54 ENVIRONMENTAL SCIENCES↗

Calculations of enrichment cascade performance using enrichment probabilities – a new method

A new method for calculating the performance of uranium enrichment cascades is presented. The method assigns a unique “enrichment probability” for each isotope to move up or down from the basic enrichment unit, allowing independent material balance calculations for each isotope. The formulation is much simpler than previous methods, which rely on isotopic ratios, and this method can be used when previous methods fail. This method gives the same results as published cases for 235 U enrichment and also gives good agreement with published data on minor isotopes. Some comparisons with measured data and other calculations are given. One case shows that the maximum 235 U enrichment that can be obtained by enrichment of reprocessed uranium (0.02% 234 U initial) is 82%. Another example shows a large difference in the minor isotopic content of material enriched in batches compared to continuous enrichment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal impacts on nondestructive analysis measurements of uranium hexafluoride

A series of nondestructive assay measurements were performed before, during, and after localized heating of an industrial standard 12B cylinder of uranium hexafluoride to replicate dose variations previously observed on commercial 30B cylinders. While cylinders represent a closed system, enrichment measurements may be impacted by altered uranium and daughter product distributions due to sublimation. A series of measurements were performed to examine localized heating impacts on dose rates, ratios of uranium and daughter product distributions, and measured 235 U enrichment as calculated by two different approaches. The less complex enrichment meter approaches were found to be more robust and less prone to deviation than isotope ratio approaches such as FRAM, but the impact can be minimized by using observable dose changes to avoid impacted areas.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Developing Methodology to Determine Pu Isotopic Composition by Laser Ablation MC-ICP-MS

This project will develop methodology to analyze the Pu isotope ratio in mixed U-Pu particles by laser ablation MC-ICP-MS. This will involve: 1) testing and validation of the Pu analytical method using mixed U-Pu solutions and Pu doped glasses, 2) isotopic analysis of mixed U-Pu particles by laser ablation MC-ICP-MS, and 3) continued development of the R-based data reduction program. Details regarding the analytical method development and results of QC testing will be output as a deliverable to the IAEA, along with an updated version of the LARA data reduction software.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Shifting modes of iron sulfidization at the onset of OAE-2 drive regional shifts in pyrite δ 34 S records

We report total reduced inorganic S isotope ratios (δ 34 S CRS ) shift toward more negative values across much of the southern North Atlantic just before the onset of the Cenomanian-Turonian Ocean Anoxic Event (OAE-2). At the same time, there is no parallel isotopic change in the significantly larger pool of kerogen (organic) S, which indicates that the distribution and S-isotope composition of sulfide in the environment likely did not drive the change in δ 34 S CRS . Here, we investigate possible explanations for the negative shift in δ 34 S CRS values and their divergence from organic S by isolating iron sulfides for morphological identification and grain-specific isotopic analysis using secondary ion mass spectrometry (SIMS). In pre- and syn-OAE-2 sedimentary rocks from Demerara Rise, we find four distinct morphologies of iron sulfides: pyrite framboids (1–20 μm diameter), irregular pyrite aggregates (1–38 μm diameter), large cemented pyrite aggregates (~60 μm diameter), and irregular and cemented aggregates of the pyrite polymorph marcasite (1–45 μm diameter). These different textural groups have distinct S-isotopic compositions that are largely consistent through the onset of OAE-2. As such, the secular change in bulk δ 34 S CRS values likely reflects the changing proportions of these phases stratigraphically across OAE-2. All textural groups feature resolvable intra-grain δ 34 S variability, suggesting that the environments in which they formed were characterized by dynamic sulfide δ 34 S values and/or by partial closed-system distillation. We use grain-specific δ 34 S distributions to rule out shoaling of the chemocline within the sediments as a mechanism for the observed decrease in δ 34 S CRS . Instead, we propose that changes in the reactivity of the iron species delivered to Demerara Rise over the ~200 kyr leading up to the onset of OAE-2 impacted the relative contributions of pyrite with S-isotope signatures reflecting the water column, shallow sediments, and deeper sediments to the bulk sedimentary δ 34 S CRS value. Specifically, the change in iron reactivity at the onset of OAE-2 favored the production of 34 S-depleted large, cemented aggregates and framboids at the expense of more 34 S-enriched irregular aggregates. Our results underscore that bulk δ 34 S CRS measurements integrate multiple reduced phases that form via distinct reaction mechanisms and potentially in different parts of the depositional environment. Grain-specific SIMS analyses dramatically enrich our ability to interpret pyrite isotopic patterns in the geologic record.

58 GEOSCIENCES↗

A multi-collector ICP-MS method for quantification of plutonium, uranium, and americium in hair and nails of occupationally or medically exposed individuals

The 239 Pu, 238 U, and 241 Am concentrations and 239 Pu/ 240 Pu, 235 U/ 238 U, and 236 U/ 238 U atom ratios were measured in the hair and nail samples from individuals who donated their bodies to the United States Transuranium and Uranium Registries. Further, the concentration of 239 Pu ranged from 0.22–15.8 ng/kg. The 240 Pu/ 239 Pu isotopic ratios ranged from 0.026 to 0.127 which is consistent with weapons-grade plutonium. Concentration of uranium fell between 1.84 µg/kg and 29.5 µg/kg and 235 U/ 238 U ratios ranged from 4.8×10 -3 to 7.6×10 -3 . Elevated 236 U/ 238 U atom ratios were measured in two cases and ranged from 5.0×10 -6 – 2.4×10 -5 indicating exposure to spent or reprocessed uranium material. The concentration of 241 Am was measured in four hair samples and ranged from 0.02–0.21 ng/kg.

61 RADIATION PROTECTION AND DOSIMETRY↗

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

Triple oxygen isotopic compositions ( 16 O, 17 O, 18 O) have conventionally been measured via isotope ratio mass spectrometry using O 2 as an analyte. Conversion of sample oxygen to O 2 typically utilizes fluorination chemistry or catalytic equilibration between CO 2 and O 2 . Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ' 17 O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ' 17 O analysis of either H 2 O or CO 2 as the analyte gas. So far, these instruments have been used to measure Δ' 17 O of water, carbonate (CO 2 liberated by acid digestion), and atmospheric CO 2 samples. Here, we present a new method for high-precision Δ' 17 O analysis of CO 2 via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO 2 in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO 2 over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ' 17 O analysis of the resulting CO 2 takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Ellis, Nicholas M. [University of California, Berk↗

Electrothermal vaporization as a new method for pre-inspection check samples

The use of electrothermal vaporization (ETV) has not been readily applied to nuclear safeguards or pre inspection check (PIC) sample analysis, even though the technique is ideally suited for low level (pg) isotopic quantification due to its high analyte transport efficiency. Here demonstrate the ETV method for PIC safeguard analysis. The ETV system is an automated, commercial of the shelf (COTS) technology, with the capability to introduce solid samples to a mass spectrometer platform. The system has been shown to simultaneously determine uranium assay, and the major isotopic ratios for uranium and plutonium. The ETV unit has demonstrated analysis up to 50 samples a day autonomously. The utilization of this ETV methodology provide a secondary option to the current PIC analysis and offers high throughput, enhanced sensitivity, and broader isotopic detection platform.

Hexel, Cole↗

A high-resolution record of Late Holocene drought in the eastern Sierra Nevada (California, USA) from June Lake carbonate geochemistry

As historic drought conditions become more common in western North America, Late Quaternary hydroclimate records become vital for putting present anthropogenic conditions into a longer-term context. Here, we establish a high-resolution record of drought for the eastern Sierra Nevada (California) using lacustrine carbonates from well-dated sediment cores. We used oxygen and carbon stable-isotope ratios, combined with high-resolution scanning X-ray fluorescence counts of calcium (Ca) and titanium (Ti), to reconstruct the drought record over the last 4600 years in June Lake. We found elevated δ 18 O and δ 13 C carbonate isotope values coinciding with peaks in both total inorganic carbon and Ca/Ti, suggesting enhanced carbonate precipitation in response to evaporative concentration of lake water. At least six intervals of prolonged (centennial-scale) carbonate deposition were identified, including three pulses during the Late Holocene Dry Period (LHDP; ~3500–2000 cal yr BP), the Medieval Climate Anomaly (~1200–800 cal yr BP), and the Current Warm Period, which began around 100 cal yr BP. This record highlights the complexities of the LHDP, an interval that was more variable at June Lake than has been previously described in regional records.

54 ENVIRONMENTAL SCIENCES↗

Using groundwater noble gas measurements to confirm paleorecharge hypotheses at Pahute Mesa, Nevada National Security Site, Nevada, USA

Pahute Mesa (Nevada, USA) was the site of 85 underground nuclear tests between 1965 and 1992 whose residual radio-chemical inventory poses a contaminant threat to local groundwater resources. To assess the fate and transport of these radionuclides in groundwater, several geochemical studies, including this one, have been conducted to understand long-term groundwater flow patterns at, and downgradient of, Pahute Mesa. Groundwater samples from the Pahute Mesa area at the Nevada National Security Site were analyzed for noble gases ( 3 He/ 4 He isotopic ratio and He, Ne, Kr, Ar and Xe concentrations) to infer groundwater recharge temperatures and provide additional evidence in support of groundwater flow patterns and the presence of late-pluvial Pleistocene groundwater. These data confirm recent findings (based on groundwater geochemistry and isotope compositions) that most recharge in the area occurred under temperature conditions much cooler than are found today, except near major drainages where ephemeral run of continues to recharge shallow groundwater. These noble gas data indicate that noble gas recharge temperatures and terrigenic He components have been reset where groundwater has flowed upward over barriers formed by caldera margins, or near the regional discharge area (Oasis Valley) where shallow groundwater has interacted with shallow soil gas. This evidence from groundwater noble gas measurements, in combination with other isotopic and geochemical studies, supports the current understanding of the unusual hydrogeology and recharge history of Pahute Mesa.

54 ENVIRONMENTAL SCIENCES↗

Direct and rapid uranium isotopic analysis of environmental sample swipes via microextraction – LS-APGD/Orbitrap mass spectrometry

Accurate and precise isotopic analysis of actinides collected on environmental sample swipes from within nuclear facilities is an important safeguarding measure for detecting undeclared materials and activities. Traditional isotope ratio (IR) analysis of actinides using a bulk digestion approach can be laborious and time-consuming. Recently, direct analysis of environmental swipe samples using a microextraction approach has been explored as an alternative to conventional bulk digestion methods. The present study further evaluates this approach for accurate and precise isotopic analysis of uranium (U) in cotton swipe samples using the liquid sampling-atmospheric pressure glow discharge (LS-APGD)/Orbitrap-FTMS Booster detection system. The instrumental parameters were optimized, and quantitative capabilities were demonstrated through excellent linearity (R2 = 0.99) across a deposited mass range of 1 to 500 ng, with a limit of detection of 90 pg (in a 2 × 4 mm region) for total U; well below typical U concentrations (ng–mg range) in environmental sample swipes. The 235U/238U ratio showed excellent accuracy (−0.3% relative difference from the certificate value), with ∼20× improvement over previous microextraction-Orbitrap methods. Precision (∼1% relative standard deviation) was also greatly enhanced by ∼5×. This study also demonstrates that figures of merit achieved with neat U solution were not highly degraded when various external interfering elements/matrices were introduced. Finally, the developed method was successfully applied to analyze practical swipe samples representative of laboratory and outdoor environments. The presented figures of merit and applicability to practical samples further validate the capability of the platform for rapid analysis (<7 minutes) of environmental swipe samples.

Shrestha, Suraj [Clemson University, SC]↗