Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Voltage Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Binary selectable detector holdoff circuit: Design, testing, and application

A very high speed switching circuit, part of a laser radar data acquisition system, has been designed and tested. The primary function of this circuit was to provide computer controlled switching of photodiode detector preamplifier power supply voltages, typically less than plus or minus 20 volts, in approximately 10 nanoseconds. Thus, in actual use, detector and/or detector preamplifier damage can be avoided as a result of sudden extremely large values of backscattered radiation being detected, such as might be due to short range, very thin atmospheric dust layers. Switching of the power supply voltages was chosen over direct switching the photodiode detector input to the preamplifier, based on system noise considerations. Also, the circuit provides a synchronized trigger pulse output for triggering devices such as the Biomation Model 8100 100 MHz analog to digital converter.

Kadrmas, K. A.↗

A photon-counting multichannel spectrometer

A multichannel detector system is described in which the positions of individual photon events in a high-gain image intensifier are decoded in the output of a video detector. The high-gain intensifier consists of a pair of three-stage electrostatic image-tube assemblies each containing three fiber-optically-coupled tubes potted in a rugged package with an internal high-voltage supply. Operation of the electrooptical system is discussed along with the pulse-detection process and the operation of the spectrograph in which the image-tube assembly is mounted. It is noted that the spectrometer detects 1.0 count/sec per A for an object of magnitude 13.0 at the peak of its response in the visual band when no light is lost on the slit, that a 10% coincidence correction is reached at an overall count rate of 860 per sec, and that the response follows an exponential law up to count rates of about 4000 per sec. The measured spectrum of the Seyfert galaxy NGC 5548 is provided as an example of the raw data produced by the instrument on a 1.5 meter telescope.

Shectman, S. A.↗

A theoretical model of current collection

Numerical simulations were carried out on the high-bias voltage on the conducting satellite for the current collection. Results show that the particle trajectories are dependent on the geomagnetic field orientation and the biased potential on both the satellite and the instrument's detector. It is noted that these particles will not escape from the plasma sheath when the B field is perpendicular to the satellite surface plane. It is also shown that part of the satellite surface will be shielded if the perpendicular magnetic field is greater than 0.35 gauss.

Hwang, Kai-Shen↗

Non-Geiger-Mode Single-Photon Avalanche Detector with Low Excess Noise

This design constitutes a self-resetting (gain quenching), room-temperature operational semiconductor single-photon-sensitive detector that is sensitive to telecommunications optical wavelengths and is scalable to large areas (millimeter diameter) with high bandwidth and efficiencies. The device can detect single photons at a 1,550-nm wavelength at a gain of 1 x 10(exp 6). Unlike conventional single photon avalanche detectors (SPADs), where gain is an extremely sensitive function to the bias voltage, the multiplication gain of this device is stable at 1 x 10(exp 6) over a wide range of bias from 30.2 to 30.9 V. Here, the multiplication gain is defined as the total number of charge carriers contained in one output pulse that is triggered by the absorption of a single photon. The statistics of magnitude of output signals also shows that the device has a very narrow pulse height distribution, which demonstrates a greatly suppressed gain fluctuation. From the histograms of both pulse height and pulse charge, the equivalent gain variance (excess noise) is between 1.001 and 1.007 at a gain of 1 x 10(exp 6). With these advantages, the device holds promise to function as a PMT-like photon counter at a 1,550- nm wavelength. The epitaxial layer structure of the device allows photons to be absorbed in the InGaAs layer, generating electron/hole (e-h) pairs. Driven by an electrical field in InGaAs, electrons are collected at the anode while holes reach the multiplication region (InAlAs p-i-n structure) and trigger the avalanche process. As a result, a large number of e-h pairs are created, and the holes move toward the cathode. Holes created by the avalanche process gain large kinetic energy through the electric field, and are considered hot. These hot holes are cooled as they travel across a p -InAlAs low field region, and are eventually blocked by energy barriers formed by the InGaAsP/ InAlAs heterojunctions. The composition of the InGaAsP alloy was chosen to have an 80 meV valance band offset with InAlAs, which is high enough to hinder the transport of the already cooled holes. Being stopped by the energy barrier, holes are accumulated at the junctions to shield the electric field, resulting in a decrease of the electric field in the multiplication region. Because the impact ionization rate is extremely sensitive to the magnitude of the electric field, the field-screening effect drastically reduces the impact ionization rate and quenches the output signals. After the avalanche pulse signal is self-quenched, the accumulated holes at the InGaAsP/ InAlAs interface escape the energy barrier through thermal excitation and tunneling and finally leave the device. The device is thus reset and ready for subsequent photon detection. This recovery time is controlled by the height of the energy barrier and the hole-cooling rate.

Zhao, Kai↗

Status of LBNF/DUNE near site liquid argon proximity and external cryogenics systems development.

The Deep Underground Neutrino Experiment (DUNE) near site located at Fermilab will host the neutrino beam complex. It includes a high voltage liquid argon time projection chamber located 60-meter underground used as beamline instrumentation. The LAr cryogenic system provided by the Long-Baseline Neutrino Facility (LBNF) regulates thermohydraulic conditions of the membrane cryostat hosting the detector with 285 Ton purified LAr. The purification system uses molecular sieve and copper oxide pellets to manage the argon contamination below 100 ppt (parts per trillion) oxygen equivalent. The detector and its cryogenics are capable to move a stroke of 30 meters on/off beam. The cryogenic system modes of operation include the cryostat pressure test, purge in open loop, detector cooldown, cryostat fill, closed loop purification, liquid empty, and purification system activation/regeneration process. The system design status and schedule, and technical details such as operating modes and interfaces are reported in this paper.

43 PARTICLE ACCELERATORS↗

Compact magnetograph

A compact magnetograph system based on solid Fabry-Perot interferometers as the spectral isolation elements was studied. The theory of operation of several Fabry-Perot systems, the suitability of various magnetic lines, signal levels expected for different modes of operation, and the optimal detector systems were investigated. The requirements that the lack of a polarization modulator placed upon the electronic signal chain was emphasized. The PLZT modulator was chosen as a satisfactory component with both high reliability and elatively low voltage requirements. Thermal control, line centering and velocity offset problems were solved by a Fabry-Perot configuration.

Title, A. M.↗

Global Geospace Science (GGS)/POLAR Thermal Ion Dynamics Experiments (TIDE) Co-Investigator Program: Mission Operations and Data Analysis (MO/DA)

We have pursued several investigations using the Polar/TIDE data set. The first was a comparison of TIDE high-altitude observations with similar ion flux signatures in the Los Alamos National Laboratory (LANL) magnetospheric plasma analyzer (MPA) data. There are several geosynchronously orbiting satellites with LANL MPA instruments onboard. When the satellite is immersed in fresh plasma sheet electrons, the spacecraft voltage drops to several hundred volts negative, and cold ions are accelerated in to the detector. In the LANL MPA spectrograms, the accelerated cold ions appear as a bright, narrow line, following the voltage of the spacecraft. This "ion line" is seen regularly on the nightside, but has not received much attention. The Polar TIDE observations indicated a ubiquitous "lobal wind" in the near-- magnetotail, a field-aligned stream of approx. 100 eV ions flowing out of both polar ionospheres. The interesting result of this research is that the MPA ion line is also peaked in the field-aligned direction, even though the potential well should be uniform in all directions. It is believed that this is evidence that the lobal winds not only populate the high-latitude lobes, but fill the lobes all the way in to the near-Earth plasma sheet (the location of geosynchronous orbit). This activity developed into a full-scale survey of the lobal wind observations in the TIDE database. The universality of these observations with respect to local time and solar wind conditions implies that the ionospheric outflow is supplying the near-Earth plasma sheet at all times, regardless of magnetic activity. We have conducted a statistical study of the characteristics of the lobal wind in these two data sets FIDE and LANL MPA), finding much similarity between them. Using these characteristics as input conditions to our inner magnetosphere ion transport model, we have conducted simulations of the flow of these particles inside of geosynchronous orbit to show the impact these particles will have on the near-Earth space environment. As the study has progressed, these results have been presented several times to the TIDE team during teleconferences. It is planned to present this survey at the GEM 2004 Summer Workshop, and hopefully at additional conferences in the near future. We are presently writing a paper on the lobal wind occurrence statistics, which should be submitted in April or May to the Journal of Geophysical Research for publication. An undergraduate student at the University of Alabama in Huntsville, Will Maddox, working at NASA MSFC with Dr. Paul Craven, is presently creating a database of the values TIDE moments for the lobal wind (under Dr. Liemohn's guidance), and this will be the focus of a follow-on paper.

Nagy, Andrew↗

Response of AC-coupled Low Gain Avalanche Detectors to Ionizing and Non-ionizing Radiation Damage

Low gain avalanche diodes with DC- and AC-coupled readout were exposed to ionizing and non-ionizing radiation at levels relevant to future experiments in particle, nuclear, and medical physics and to astrophysics. Damage-related change in their acceptor removal constants and in the resistivity of the region between the guard ring and the active area are reported, as is change in the leakage current and depletion voltages of the active volumes.

FOS: Physical sciences↗

Development of Low-Noise High Value Chromium Silicide Resistors for Cryogenic Detector Applications

Extremely high sensitivity detectors, such as silicon bolometers are required in many NASA missions for detection of photons from the x-ray to the far infrared regions. Typically, these detectors are cooled to well below the liquid helium (LHe) temperature (4.2 K) to achieve the maximum detection performance. As photoconductors, they are generally operated with a load resistor and a pre-set bias voltage, which is then coupled to the input gate of a source-follower Field Effect Transistor (FET) circuit. It is imperative that the detector system signal to noise performance be limited by the noise of the detector and not by the noise of the external components. The load resistor value is selected to optimize the detector performance. These two criteria tend to be contradictory in that these detectors require load resistors in the hundreds of megaohms, which leads to a higher Johnson noise. Additionally, the physical size of the resistor must be small for device integration as required by such missions as the NASA High Resolution Airborne Wide-Band Camera (HAWC) instrument and the Submillimeter High Angular Resolution Camera (SHARC) for the Caltech Submillimeter Observatory (CSO). We have designed, fabricated and characterized thin film resistors using a CrSi/TiW/Al metal system on optical quality quartz substrates. The resistor values range from 100 megaohms to over 650 megaohms and are Johnson noise limited at LHe temperatures. The resistor film is sputtered with a sheet resistance ranging from 300 ohms to 1600 ohms and the processing sequence developed for these devices allows for chemically fine tuning the sheet resistance in-situ. The wafer fabrication process was of sufficiently high yield (>80%) providing clusters of good resistors for integrated multiple detector channels, a very important feature in the assembly of these two instruments.

Jhabvala, Murzy↗

The 4D Camera: An 87 kHz Direct Electron Detector for Scanning/Transmission Electron Microscopy

We describe the development, operation, and application of the 4D Camera—a 576 by 576 pixel active pixel sensor for scanning/transmission electron microscopy which operates at 87,000 Hz. The detector generates data at ~480 Gbit/s which is captured by dedicated receiver computers with a parallelized software infrastructure that has been implemented to process the resulting 10–700 Gigabyte-sized raw datasets. The back illuminated detector provides the ability to detect single electron events at accelerating voltages from 30 to 300 kV. Through electron counting, the resulting sparse data sets are reduced in size by 10--300× compared to the raw data, and open-source sparsity-based processing algorithms offer rapid data analysis. The high frame rate allows for large and complex scanning diffraction experiments to be accomplished with typical scanning transmission electron microscopy scanning parameters.

47 OTHER INSTRUMENTATION↗

Layout and performance of HPK prototype LGAD sensors for the High-Granularity Timing Detector

The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology, will cover the pseudo-rapidity region of 2.4 < |n| < 4.0 with two end caps on each side and a total area of 6.4 m 2 . The timing performance can be improved by implanting an internal gain layer that can produce signals with a fast rising edge. It significantly improves the signal-to-noise ratio. The required average timing resolution per track for a minimum ionizing particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1MeV neutron-equivalent fluence up to 2.5 10 15 n eq /cm 2 including a safety factor of 1.5 before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-ups at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.

47 OTHER INSTRUMENTATION↗

UAV Inspection of Electrical Transmission Infrastructure with Path Conformance Autonomy and Lidar-Based Geofences NASA Report on UTM Reference Mission Flights at Southern Company Flights November 2016

Flights at low altitudes in close proximity to electrical transmission infrastructure present serious navigational challenges: GPS and radio communication quality is variable and yet tight position control is needed to measure defects while avoiding collisions with ground structures. To advance unmanned aerial vehicle (UAV) navigation technology while accomplishing a task with economic and societal benefit, a high voltage electrical infrastructure inspection reference mission was designed. An integrated air-ground platform was developed for this mission and tested in two days of experimental flights to determine whether navigational augmentation was needed to successfully conduct a controlled inspection experiment. The airborne component of the platform was a multirotor UAV built from commercial off-the-shelf hardware and software, and the ground component was a commercial laptop running open source software. A compact ultraviolet sensor mounted on the UAV can locate 'hot spots' (potential failure points in the electric grid), so long as the UAV flight path adequately samples the airspace near the power grid structures. To improve navigation, the platform was supplemented with two navigation technologies: lidar-to-polyhedron preflight processing for obstacle demarcation and inspection distance planning, and trajectory management software to enforce inspection standoff distance. Both navigation technologies were essential to obtaining useful results from the hot spot sensor in this obstacle-rich, low-altitude airspace. Because the electrical grid extends into crowded airspaces, the UAV position was tracked with NASA unmanned aerial system traffic management (UTM) technology. The following results were obtained: (1) Inspection of high-voltage electrical transmission infrastructure to locate 'hot spots' of ultraviolet emission requires navigation methods that are not broadly available and are not needed at higher altitude flights above ground structures. (2) The sensing capability of a novel airborne UV detector was verified with a standard ground-based instrument. Flights with this sensor showed that UAV measurement operations and recording methods are viable. With improved sensor range, UAVs equipped with compact UV sensors could serve as the detection elements in a self-diagnosing power grid. (3) Simplification of rich lidar maps to polyhedral obstacle maps reduces data volume by orders of magnitude, so that computation with the resultant maps in real time is possible. This enables real-time obstacle avoidance autonomy. Stable navigation may be feasible in the GPS-deprived environment near transmission lines by a UAV that senses ground structures and compares them to these simplified maps. (4) A new, formally verified path conformance software system that runs onboard a UAV was demonstrated in flight for the first time. It successfully maneuvered the aircraft after a sudden lateral perturbation that models a gust of wind, and processed lidar-derived polyhedral obstacle maps in real time. (5) Tracking of the UAV in the national airspace using the NASA UTM technology was a key safety component of this reference mission, since the flights were conducted beneath the landing approach to a heavily used runway. Comparison to autopilot tracking showed that UTM tracking accurately records the UAV position throughout the flight path.

Moore, Andrew J.↗

High current compensation network for dc logarithmic amplifiers

Circuit voltage output is reduced by voltage equivalent to ampere resistance drop of nonlogarithmic resistances of practical diodes; therefore, output is same as circuit using ideal diode. Circuit applies to meter and electronic recorder movements, and improves performance of radiation detectors and several microbiological monitoring devices

Wilson, J. H.↗

Narrow Line X-Ray Calibration Source for High Resolution Microcalorimeters

We are developing a narrow line calibration source for use with X-ray microcalorimeters. At energies below 300 electronvolts fluorescent lines are intrinsically broad, making calibration of high resolution detectors difficult. This source consists of a 405 nanometers (3 electronvolts) laser diode coupled to an optical fiber. The diode is pulsed to create approximately one hundred photons in a few microseconds. If the pulses are short compared to the rise time of the detector, they will be detected as single events with a total energy in the soft X-ray range. Poisson fluctuations in photon number per pulse create a comb of X-ray lines with 3 electronvolts spacing, so detectors with energy resolution better than 2 electronvolts are required to resolve the individual lines. Our currently unstabilized diode has a multimode width less than 1 nanometer, giving a 300 electronvolt event a Full width at half maximum (FWHM) less than 0.1 electronvolts. By varying the driving voltage, or pulse width, the source can produce a comb centered on a wide range of energies. The calibration events are produced at precisely known times. This allows continuous calibration of a flight mission without contaminating the observed spectrum and with minimal deadtime.

high resolution detectors↗

AI for Experimental Controls at Jefferson Lab

We report the AI for Experimental Controls project is developing an AI system to control and calibrate detector systems located at Jefferson Laboratory. Currently, calibrations are performed offline and require significant time and attention from experts. This work would reduce the amount of data and the amount of time spent calibrating in an offline setting. The first use case involves the Central Drift Chamber (CDC) located inside the GlueX spectrometer in Hall D. We use a combination of environmental and experimental data, such as atmospheric pressure, gas temperature, and the flux of incident particles as inputs to a sequential Neural Network (NN) to recommend a high voltage setting and the corresponding calibration constants in order to maintain consistent gain and optimal resolution throughout the experiment. Utilizing AI in this manner represents an initial shift from offline calibration towards near real time calibrations performed at Jefferson Laboratory.

47 OTHER INSTRUMENTATION↗

LaF3 insulators for MIS structures

Thin films of LaF3 deposited on Si or GaAs substrates have been observed to form blocking contacts with very high capacitances. This results in comparatively hysteresis-free and sharp C-V (capacitance-voltage) characteristics for MIS structures. Such structures have been used to study the interface states of GaAs with increased resolution and to construct improved photocapacitive infrared detectors.

Sher, A.↗

New techniques for the detection and capture of micrometeoroids

In order to understand the origin and distribution of the biogenic elements and their compounds in the solar system, it will be necessary to study materials from many classes of objects. Chemical, elemental, and isotopic measurements of returned samples of comets, asteroids, and possibly extra-solar system dust clouds would provide information on a particularly important class: primitive objects. Extraterrestrial micron-sized particles in the vicinity of Earth are one source of such materials that might otherwise be inaccessible. The Space Station appears to be an eminently suitable platform from which to collect and detect these various particles. The primary challenge, however, is to collect intact, uncontaminated particles which will be encountered at tens of kilometers per seconds. A concept for a micrometeoroid detector that could be deployed from the Space Station was developed which uses a large area detector plate implanted with acoustic transducers. When an impact event occurs, the resulting signal is subjected to spectral analysis providing positive detection, momentum information, and angle of incidence. The primary advantage of this detector is the large area which increases the probability of measuring events. A concept of a nondestuctive micrometeoroid collector for use from a Space Station was also developed. The collector utilizes input port charging of the incoming particle followed by staged high voltage deceleration for nondestructive capture. Low velocity particles (local contamination) would be rejected due to insufficient energy and only uncontaminated micrometeoroids would be collected.

Wolfe, J. H.↗

Characterizing novel Indium Phosphide pad detectors with focused X-ray beams and laboratory tests

Future tracking systems in High Energy Physics experiments will require large instrumented areas with low radiation length. Crystalline silicon sensors have been used in tracking systems for decades, but are difficult to manufacture and costly to produce for large areas. We are exploring alternative sensor materials that are amenable to fast fabrication techniques used for thin film devices. Indium Phosphide pad sensors were fabricated at Argonne National Lab using commercially available InP:Fe 2-inch mono-crystal substrates. Current-voltage and capacitance-voltage characterizations were performed to study the basic operating characteristics of a group of sensors. Micro-focused X-ray beams at Canadian Light Source and Diamond Light Source were used to study the response to ionizing radiation, and characterize the uniformity of the response for several devices. Electrical test results showed a high degree of performance uniformity between the 48 tested devices. X-ray test beam results showed good performance uniformity within tested devices after accounting for spatially-local defects and edge fields. As a result, this motivates further studies into thin film devices for future tracking detectors.

47 OTHER INSTRUMENTATION↗