Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM LOSS MONITOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The neutron camera upgrade for MAST Upgrade

The Neutron Camera Upgrade (NCU) is a neutron flux monitor consisting of six lines of sight (LoSs) under installation on Mega Ampere Spherical Tokamak (MAST) Upgrade. The NCU is expected to contribute to the study of the confinement of fast ions and on the efficiency of non-inductive current drive in the presence of on-axis and off-axis neutral beam injection by measuring the neutron emissivity profile along the equatorial plane. This paper discusses the NCU main design criteria, the engineering and interfacing issues, and the solutions adopted. In addition, the results from the characterization and performance studies of the neutron detectors using standard γ-rays sources and a 252 Cf source are discussed. The proposed design has a time resolution of 1 ms with a statistical uncertainty of less than 10% for all MAST Upgrade scenarios with a spatial resolution of 10 cm: higher spatial resolution is possible by moving the LoSs in-between plasma discharges. Finally, the energy resolution of the neutron detector is better than 10% for a light output of 0.8 MeVee, and the measured pulse shape discrimination is satisfactory.

47 OTHER INSTRUMENTATION↗

Investigating the possibility of a monitoring fast ion diagnostic for ITER

In burning plasma fusion devices, fast ion transport plays a central role in the performances of the machines. Moreover the losses of energetic particles might cause severe damages on plasma facing components. Therefore real time measurements of fast ion transport would provide valuable information for safe and reliable plasma operations. In this paper, we examine the feasibility of a monitoring system based on active charge exchange recombination spectroscopy making use of the 0.5 MeV/amu ITER heating neutral beams for detecting fast {sup 4}He{sup +2} (alphas) particles in ITER plasmas. There are two time scales relevant to fast ion dynamics: the first is the slowing down time of the distribution function which is of the order of 1 s, and the second is the time scale of burstlike transport events such as collective Alfven mode excitations, which--for typical ITER plasma parameters--can be as low as 0.2-1 ms. To detect such fast events a broadband high-throughput spectrometer is needed, while for the reconstruction of the alpha velocity distribution function a higher resolution spectrometer and longer integration time are necessary. To monitor a spatial redistribution of fast particles due to the propagation of the instability, it is proposed to use a limited number of spatial channels, looking at the charge exchange He II spectra induced by the heating beams, whose energy matches the slowing down energies of fast particles. The proposal is to share the motional stark effect periscope on equatorial port 3 [A. Malaquias et al., Rev. Sci. Instrum. 75, 3393 (2004)] adding additional fibers and suitable instruments. A signal to noise ratio of 5 could be achieved with a spatial resolution of a/15 and a time resolution of 5 ms, in a broad spectral band of 100 A, corresponding to the spectral broadening of the line emitted by alpha particles with energies {delta}E{<=}1.5 MeV. Fast H and D ion populations created by heating neutral beam or ion cyclotron resonance heating are expected to produce significantly lower charge exchange signal levels and can only be monitored on substantially longer time scales as it is expected because of the strong energy difference with respect to the heating neutral beam and the consequently low charge exchange cross sections.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Response of Polarized Protons in Solid Hydrogen-Deuteride(HD) to Electron Beams

Solid frozen-spin polarized targets of hydrogen-deuteride(HD) have been proven advantageous in photon beam experiments, where they exhibit immeasurably long spin-relaxation times(T1). The present research investigates their potential applicability to experiments with minimum-ionizing charged-particle beams. Studies have been conducted with sub-nanoAmp CW currents of 10 MeV electron beams at the newly commissioned Upgraded Injector Test Facility (UITF) at Jefferson Lab (JLab). Since the energy deposition is almost independent of electron beam energy, these UITF experiments provide insight on the expected performance at the GeV energies required in typical JLab experiments. A horizontal in-beam dilution refrigerator equipped with superconducting solenoids has been used to maintain solid HD samples at about 0.1K and 1 Tesla. NMR coils sur rounding the HD target have been used to monitor hydrogen polarization. Thermal equilibrium polarizations of targets not in the frozen-spin state (with intentionally short T1) have been used to deduce the in situ temperature of solid HD while under electron bombardment. The behavior of a 40% H-polarized frozen-spin target has been tracked while exposed to beams under various conditions. Polarization loss has been observed to be approximately proportional to dose, with the target polarization dropping to 1/e of its initial value after about 6 µC cm2 , about 4 ? 1013 beam particles/cm2 . A model for depolarization by beam-associated paramagnetic impurities largely accounts for the data, and suggests that improvements in heat removal could lead to significant increases in the in-beam T1

Wei, Kevin↗

Technical Note: Implementation of biological washout processes within GATE/GEANT4—A Monte Carlo study in the case of carbon therapy treatments

Purpose: The imaging of positron emitting isotopes produced during patient irradiation is the only in vivo method used for hadrontherapy dose monitoring in clinics nowadays. However, the accuracy of this method is limited by the loss of signal due to the metabolic decay processes (biological washout). In this work, a generic modeling of washout was incorporated into the GATE simulation platform. Additionally, the influence of the washout on the β{sup +} activity distributions in terms of absolute quantification and spatial distribution was studied. Methods: First, the irradiation of a human head phantom with a {sup 12}C beam, so that a homogeneous dose distribution was achieved in the tumor, was simulated. The generated {sup 11}C and {sup 15}O distribution maps were used as β{sup +} sources in a second simulation, where the PET scanner was modeled following a detailed Monte Carlo approach. The activity distributions obtained in the presence and absence of washout processes for several clinical situations were compared. Results: Results show that activity values are highly reduced (by a factor of 2) in the presence of washout. These processes have a significant influence on the shape of the PET distributions. Differences in the distal activity falloff position of 4 mm are observed for a tumor dose deposition of 1 Gy (T{sub ini} = 0 min). However, in the case of high doses (3 Gy), the washout processes do not have a large effect on the position of the distal activity falloff (differences lower than 1 mm). The important role of the tumor washout parameters on the activity quantification was also evaluated. Conclusions: With this implementation, GATE/GEANT 4 is the only open-source code able to simulate the full chain from the hadrontherapy irradiation to the PET dose monitoring including biological effects. Results show the strong impact of the washout processes, indicating that the development of better models and measurement of biological washout data are essential.

60 APPLIED LIFE SCIENCES↗

An e.s.c.a. study of atomic oxygen interactions with phosphazene-coated polyimide films

Metallic as well as most nonmetallic materials experience oxidation and mass loss via surface erosion in low earth orbit as shown in previous Space Shuttle flights. This study is an evaluation of select polyphosphazene polymers and their resistance to atomic oxygen attack. Electron spectroscopy for chemical analysis examinations of the surfaces of polyphosphazene coatings were monitored for microstructural changes induced during exposures to atomic oxygen. Sample exposures in oxygen plasmas and O(3P) beam were compared as to their effect on surface compositional changes in the polyphosphazene coating. High resolution line scans revealed rearrangements in the polymer backbone and scissioning reactions involving fluorocarbon units of long chain fluoroalkoxy pendant groups. Atom percents and peak areas of all species provided a detailed profile of the microstructural changes induced in phosphazene polymers as a result of exposures to atomic oxygen.

Fewell, Larry L.↗

ION-INDUCED PROCESSING OF COSMIC SILICATES: A POSSIBLE FORMATION PATHWAY TO GEMS

Ion-induced processing of dust grains in the interstellar medium and in protoplanetary and planetary disks plays an important role in the entire dust cycle. We have studied the ion-induced processing of amorphous MgFeSiO{sub 4} and Mg{sub 2}SiO{sub 4} grains by 10 and 20 keV protons and 90 keV Ar{sup +} ions. The Ar{sup +} ions were used to compare the significance of the light protons with that of heavier, but chemically inert projectiles. The bombardment was performed in a two-beam irradiation chamber for in situ ion-implantation at temperatures of 15 and 300 K and Rutherford Backscattering Spectroscopy to monitor the alteration of the silicate composition under ion irradiation. A depletion of oxygen from the silicate structure by selective sputtering of oxygen from the surface of the grains was observed in both samples. The silicate particles kept their amorphous structure, but the loss of oxygen caused the reduction of ferrous (Fe{sup 2+}) ions and the formation of iron inclusions in the MgFeSiO{sub 4} grains. A few Si inclusions were produced in the iron-free magnesium silicate sample pointing to a much less efficient reduction of Si{sup 4+} and formation of metallic Si inclusions. Consequently, ion-induced processing of magnesium-iron silicates can produce grains that are very similar to the glassy grains with embedded metals and sulfides frequently observed in interplanetary dust particles and meteorites. The metallic iron inclusions are strong absorbers in the NIR range and therefore a ubiquitous requirement to increase the temperature of silicate dust grains in IR-dominated astrophysical environments such as circumstellar shells or protoplanetary disks.

79 ASTRONOMY AND ASTROPHYSICS↗

Machine-learning-assisted analysis of transition metal dichalcogenide thin-film growth

In situ reflective high-energy electron diffraction (RHEED) is widely used to monitor the surface crystalline state during thin-film growth by molecular beam epitaxy (MBE) and pulsed laser deposition. With the recent development of machine learning (ML), ML-assisted analysis of RHEED videos aids in interpreting the complete RHEED data of oxide thin films. The quantitative analysis of RHEED data allows us to characterize and categorize the growth modes step by step, and extract hidden knowledge of the epitaxial film growth process. In this study, we employed the ML-assisted RHEED analysis method to investigate the growth of 2D thin films of transition metal dichalcogenides (ReSe2) on graphene substrates by MBE. Principal component analysis (PCA) and K-means clustering were used to separate statistically important patterns and visualize the trend of pattern evolution without any notable loss of information. Using the modified PCA, we could monitor the diffraction intensity of solely the ReSe2 layers by filtering out the substrate contribution. These findings demonstrate that ML analysis can be successfully employed to examine and understand the film-growth dynamics of 2D materials. Further, the ML-based method can pave the way for the development of advanced real-time monitoring and autonomous material synthesis techniques.

36 MATERIALS SCIENCE↗

Progress in Development of HIFU CMUTs for use under MR-guidance

High intensity focused ultrasound (HIFU) guided by magnetic resonance imaging (MRI) is a noninvasive treatment that potentially reduces patient morbidity, lowers costs, and increases treatment accessibility. Traditionally, piezoelectric transducers are used for HIFU, but capacitive micromachined ultrasonic transducers (CMUTs) have many advantages, including fabrication flexibility, low loss, and efficient transmission. We designed, fabricated, and tested HIFU CMUTs for use under MRI guidance and have demonstrated continuous wave (CW) focusing. In this paper, we demonstrate that CMUTs can be designed for therapeutic ultrasound. First, we demonstrate successful unfocused heating of a HIFU phantom to 18.6 deg. C, which was successfully monitored under MR guidance. Second, we demonstrated a focused CMUT array whose beam profile matched with simulation. In the future, we will expand the array and system for upper abdominal cancer therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AN EXPERIMENT TO LOCATE THE SITE OF TeV FLARING IN M87

We describe a Chandra X-ray target-of-opportunity project designed to isolate the site of TeV flaring in the radio galaxy M87. To date, we have triggered the Chandra observations only once (2010 April) and by the time of the first of our nine observations, the TeV flare had ended. However, we found that the X-ray intensity of the unresolved nucleus was at an elevated level for our first observation. Of the more than 60 Chandra observations we have made of the M87 jet covering nine years, the nucleus was measured at a comparably high level only three times. Two of these occasions can be associated with TeV flaring, and at the time of the third event, there were no TeV monitoring activities. From the rapidity of the intensity drop of the nucleus, we infer that the size of the emitting region is of order a few light days Multiplication-Sign the unknown beaming factor; comparable to the same sort of estimate for the TeV emitting region. We also find evidence of spectral evolution in the X-ray band which seems consistent with radiative losses affecting the non-thermal population of the emitting electrons within the unresolved nucleus.

79 ASTRONOMY AND ASTROPHYSICS↗

BEAM STUDIES AT THE SNS LINAC

The most recent beam dynamics studies at the Spallation Neutron Source (SNS) linac, including major beam loss reduction efforts in the normal conducting linac and in the superconducting linac (SCL), and the simulation and measurement of longitudinal beam halo and longitudinal acceptance at the entrance of the SCL are discussed. Oscillation of the beam centroid around the linac synchronous phase and the phase adiabatic damping curves in the SNS linac are investigated with linac longitudinal models and measured with all the linac beam phase monitors.

43 PARTICLE ACCELERATORS↗

Disruption of SLX4-MUS81 Function Increases the Relative Biological Effectiveness of Proton Radiation

Purpose: Clinical proton beam therapy has been based on the use of a generic relative biological effectiveness (RBE) of ∼1.1. However, emerging data have suggested that Fanconi anemia (FA) and homologous recombination pathway defects can lead to a variable RBE, at least in vitro. We investigated the role of SLX4 (FANCP), which acts as a docking platform for the assembly of multiple structure-specific endonucleases, in the response to proton irradiation. Methods and Materials: Isogenic cell pairs for the study of SLX4, XPF/ERCC1, MUS81, and SLX1 were irradiated at the mid-spread-out Bragg peak of a clinical proton beam (linear energy transfer 2.5 keV/μm) or with 250 kVp x-rays, and the clonogenic survival fractions were determined. To estimate the RBE of the protons relative to cobalt-60 photons (Co60Eq), we assigned a RBE(Co60Eq) of 1.1 to x-rays to correct the physical dose measured. Standard DNA repair foci assays were used to monitor the damage responses, and the cell cycle distributions were assessed by flow cytometry. The poly(ADP-ribose) polymerase inhibitor olaparib was used for comparison. Results: Loss of SLX4 function resulted in an enhanced proton RBE(Co60Eq) of 1.42 compared with 1.11 for wild-type cells (at a survival fraction of 0.1; P<.05), which correlated with increased persistent DNA double-strand breaks in cells in the S/G{sub 2} phase. Genetic analysis identified the SLX4-binding partner MUS81 as a mediator of resistance to proton radiation. Both proton irradiation and olaparib treatment resulted in a similar prolonged accumulation of RAD51 foci in SLX4/MUS81-deficient cells, suggesting a common defect in the repair of DNA replication fork-associated damage. Conclusions: A defect in the FA pathway at the level of SLX4 results in hypersensitivity to proton radiation, which is, at least in part, due to impaired MUS81-mediated processing of replication forks that stall at clustered DNA damage. In vivo and clinical studies are needed to confirm these findings in human cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep Geothermal Drilling Using Millimeter Wave Technology (Final Technical Research Report)

Conventional drilling methods are very mature, but still have difficulty drilling through very deep,very hard and hot rocks for geothermal, nuclear waste entombment and oil and gas applications.This project demonstrated the capabilities of utilizing only high energy beams to drill such rocks,commonly called ‘Direct Energy Drilling’, which has been the dream of industry since the invention of the laser in the 1960s. A new region of the electromagnetic spectrum, millimeter wave (MMW) wavelengths at 30-300 giga-hertz (GHz) frequency was used to accomplish this feat. To demonstrate MMW beam drilling capabilities a lab bench waveguide delivery, monitoring and instrument system was designed, built and tested around an existing (but non-optimal) 28 GHz frequency, 10 kilowatt (kW) gyrotron. Low waveguide efficiency, plasma generation and reflected power challenges were overcome. Real-time monitoring of the drilling process was also demonstrated. Then the technical capability of using only high power intense millimeter waves to melt (with some vaporization) four different rock types (granite, basalt, sandstone, limestone) was demonstrated through 36 bench tests. Full bore drilling up to 2” diameter (size limited by the available MMW power) was demonstrated through granite and basalt samples. The project also demonstrated that MMW beam transmission losses through high temperature (260°C, 500oF), high pressure (34.5 MPa, 5000 psi) nitrogen gas was below the error range of the meter long path length test equipment and instruments utilized. To refine those transmission losses closer, to allow extrapolation to very great distances, will require a new test cell design and higher sensitivity instruments. All rock samples subjected to high peak temperature by MMW beams developed fractures due to thermal stresses, although the peak temperature was thermodynamically limited by radiative losses. Therefore, this limited drill rate and rock strength data were not able to be determined experimentally. New methods to encapsulate larger rock specimens must be developed and higher power intensities are needed to overcome these limitations. It was demonstrated that rock properties are affected (weakening then strengthened) by exposure to high temperatures. Since only MMW beams can economically reach rock temperatures of over 1650°C, even exceeding 3000°C, that can cause low viscosity melts or vaporization of rocks. Future encapsulated rock specimens must provide sufficiently large sizes of thermally impacted material to provide for the necessary rock strength, permeability and other analyzes required. Multiple MMW field systems, tools and methods for drilling and lining were identified. It was concluded that forcing a managed over-pressure drilling operation would overcome water influx and hot rock particulates handling problems, while simultaneously forming the conditions necessary to create a strong, sealing rock melt liner. Materials that contact hot rock surfaces were identified for further study. High power windows and gases for beam transmission under high pressures are critical paths for some of the MMW drilling systems. Straightness/ alignment can be a great benefit or a problem, especially if a MMW beam is transmitted through an existing, conventionally drilled bore.

04 OIL SHALES AND TAR SANDS↗

Low-loss superconducting titanium nitride grown using plasma-assisted molecular beam epitaxy

Titanium nitride (TiN) is a known superconducting material that is attractive for use as passive components in superconducting circuits for both conventional and quantum information devices. In contrast to conventional synthesis techniques, here, plasma-assisted molecular beam epitaxy is reported to produce high-quality TiN on bare silicon wafers. Using a rf-plasma source to crack the nitrogen molecules and a conventional high-temperature effusion cell for titanium, TiN growth is completed under nitrogen-rich conditions. The growth and nucleation is monitored in situ, while the structure and composition are characterized using x-ray diffraction, atomic force microscopy, x-ray photoelectron spectroscopy, secondary ion mass spectroscopy, and scanning transmission electron microscopy. The stoichiometric TiN (111) films sit on an amorphous nitride layer with low impurity concentrations. The films superconduct with Tc=5.4 K, and coplanar waveguide resonators are fabricated with a small center width of 6 μm that demonstrate single-photon quality factors approaching 1M and high-power quality factors over 5M without observing saturation.

Richardson, C. J. K. (ORCID:0000000188175347)↗

Detectors and beam monitors based on wide bandgap semiconductors at cryogenic temperatures

Wide-bandgap semiconductors, such as single-crystal diamond and sapphire, can be used to measure the flux of passing particles through a particle-induced conductivity effect. We recently demonstrated a diamond-based, electrodeless electron beam halo monitor. This monitor utilized a thin diamond blade placed within an open, high-quality microwave resonator. The blade partially intercepted the beam and changes in the RF properties of the resonator were used to infer beam parameters. To enhance the sensitivity of our semiconductor sensors, we propose two new techniques: (1) biasing the semiconductor sensor to support avalanche multiplication of free carriers, and (2) operating at cryogenic temperatures to reduce intrinsic semiconductor losses and increase the mobility of induced carriers. These techniques are applicable not only to particle beam diagnostics but also to the detection of various types of ionizing radiation.

Accelerator Physics↗

Report on LEReC Recombination Monitor APEX Study on June 15th 2016

During the prospective Low Energy RHIC electron Cooling (LEReC) operation, the electron beam will overlap and interact with the low energy ion beam to provide transverse cooling. Cooling is needed to facilitate reaching the BES-2 (Beam Energy Scan 2) program goals of an average store luminosity of 5 × 10 24 cm -2 s -1 at 3.85 GeV/n and 17.3 × 10 24 cm -2 s -1 at 9.1 GeV/n. The RHIC phase of BES-2 is currently planned for the RHIC runs in 2019 and 2020. Effective cooling will depend on the accuracy of velocity matching between the two beams. Another process, the rate of ion-electron recombination, is also maximized when the velocities are matched, but the exact matching requirement is less stringent. Therefore, as suggested by one of us, detecting and maximizing recombination signals should be helpful in finding the narrow velocity matching window conducive to cooling. When 197 Au 79+ RHIC ions pick up an electron from the LEREeC electron beam they are converted into 197 Au 78+ ions with nearly the same momentum while having about 1.3% higher magnetic rigidity than the original 197 Au 79+ particles. The detection of the recombined ions can be done by driving the 197 Au 78+ beam into the beam pipe wall, creating showers of secondary particles which then can be detected outside the cryostat by using appropriately positioned detectors. For the purpose of forcing losses of the expected off-momentum particles a dedicated lattice with large horizontal dispersion in one arc was proposed and designed.

43 PARTICLE ACCELERATORS↗

Automated Calibration System for Beam Current Monitor

The Beam Current Monitor (BCM) measures the instantaneous current in a beam. This work aims to develop an automated calibration system for the BCM to address the need for calibration without interrupting beam operation. We strive to create a synchronous calibration method integrated into the master timeline by utilizing the pulsed nature of synchrotrons to run calibration pulses during inter-pulse gaps. This improvement should enhance operational efficiency, ensure safe operation, and help mitigate beam loss, all by enabling intermittent calibration during the operation of the accelerator. This is accomplished by developing a Python program that interfaces with a Keithley 6221 DC and AC source and a Keithley 2182A Nanovoltmeter. The program configures both of these devices to perform a selected mode of the current sweep, allows for the initiation of the current sweep, collects the measured voltage data from the 2182A, stores the collected data to the computer in a CSV file, and graphs the collected data.

Haller, James↗

Machine Learning for LBNF Beam Diagnostics

This paper focuses on developing a machine learning model for predicting initial beam parameters for the Long Baseline Neutrino Facility (LBNF) beamline using downstream muon monitor data. Parameters such as proton beam position on target, sigma on target, focusing horn current, and focusing horn tilt are parameters we anticipate to be predictable based on the muon monitors. Uncertainty in initial beam condition measurements are a major contributor to uncertainty in downstream flux, and over operation time beam misalignment can occur [1]. A machine learning model has promise to detect anomalies along the beamline based on discrepancies between predicted configurations and measured configurations, and thus can expedite error detection and handling. A PyTorch neural network is defined, trained, and tested. The developed model currently does not provide reliable predictions, with the lowest loss being 0.09.. Further steps to improve the model’s accuracy are discussed, as well as future plans to detect anomalous beam conditions using a digital twin.

O'Brien, Bridget [Fermilab]↗

The GlueX beamline and detector

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μs$. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. Here, we describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗