Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Improvement of Contact Resistance with Molecular Ion Implantation

Basic characteristics of ClusterBoron (B{sub 18}H{sub 22}) implantation were investigated for improving contact resistance in DRAM devices. Generally, {sup 49}BF{sub 2} has been widely used for contact implant application in DRAM manufacturing because of its higher productivity compared to monomer boron ({sup 11}B). However, because of limited activation in a low thermal budget ({approx}800 deg. C) anneal, the sheet resistance was saturated for doses over 5x10{sup 15} ions/cm{sup 2}. Although many investigations have been reported, such as {sup 30}BF implant mixed implant with monomer boron etc., no practical solution has been found for dramatic improvement of contact resistance in a productive manner. B{sub 18}H{sub 22} was developed to overcome the productivity limitations encountered in low energy, high dose boron implantation and the limited activation of {sup 49}BF{sub 2} due to co-implanted fluorine. In this study, basic characterization of the B{sub 18}H{sub 22} contact implant was performed through sheet resistance, SIMS (Secondary Ion Mass Spectrometry) and XTEM (cross-sectional transmission electron microscopy). The B{sub 18}H{sub 22} implants showed lower sheet resistance than conventional {sup 49}BF{sub 2} for 5x10{sup 15} ions/cm{sup 2} on bare wafer tests. Through XTEM study, we found the activation behavior of both B{sub 18}H{sub 22} and {sup 49}BF{sub 2} were directly related with the amorphous layer thickness and residual defects from low thermal budget anneal. PMOS contact resistance in the sub-70 nm device by B{sub 18}H{sub 22} implantation showed considerable improvement (about 30%), showing B{sub 18}H{sub 22} could replace the BF{sub 2} for contact implant in contact resistance implant.

36 MATERIALS SCIENCE↗

Chemical and bonding analysis of liquids using liquid cell electron microscopy

Liquid cell transmission electron microscopy (TEM) has become an essential tool for studying the structure and properties of both hard and soft condensed-matter samples, as well as liquids themselves. Liquid cell sample holders, often consisting of two thin window layers separating the liquid sample from the high vacuum of the microscope column, have been designed to control in situ conditions, including temperature, voltage/current, or flow through the window region. While high-resolution and time-resolved TEM imaging probes the structure, shape, and dynamics of liquid cell samples, information about the chemical composition and spatially resolved bonding is often difficult to obtain due to the liquid thickness, the window layers, the holder configuration, or beam-induced radiolysis. Here, we review different approaches to quantitative liquid cell electron microscopy, including recent developments to perform energy-dispersive x-ray and electron energy-loss spectroscopy experiments on samples in a liquid environment or the liquid itself. We also cover graphene liquid cells and other ultrathin window layer holders.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of a reducing environment in disassembly of the herpesvirus tegument

Initiation of infection by herpes family viruses involves a step in which most of the virus tegument becomes detached from the capsid. Detachment takes place in the host cell cytosol near the virus entry site and it is followed by dispersal of tegument proteins and disappearance of the tegument as a distinct entity. Here we describe the results of experiments designed to test the idea that the reducing environment of the cytosol may contribute to tegument detachment and disassembly. Non-ionic detergent was used to remove the membrane of purified herpes simplex virus under control and reducing conditions. The effects on the tegument were then examined by SDS-PAGE and electron microscopy. Protein analysis demonstrated that most major tegument proteins were removed under both oxidizing and reducing conditions except for UL49 which required a reducing environment. It is proposed therefore that the reducing conditions in the cytosol are involved in removal of UL49 protein. Electron microscopic analysis revealed that capsids produced under oxidizing conditions contained a coating of protein that was absent in reduced virions and which correlated uniquely with the presence of UL49. This capsid-associated layer is suggested to be the location of UL49 in the extracted virion.

60 APPLIED LIFE SCIENCES↗

In-Situ Liquid Cell Transmission Electron Microscopy of Nanoparticles from Spent Nuclear Fuel

Noble Metal Particles (NMP) that are present in SNF play an important role in the Fuel Matrix Degradation (FMD) Model that is being considered for predicting the release rate of radionuclides from a waste package. Previous characterization of chemically separated NMP from SNF showed that these were well-crystallized nanoparticles containing Mo, Tc, Ru, Rh, and Pd with some evidence of actinides. These same chemically separated particles were re-characterized following 10 years of storage as the separated material in water. Scanning Transmission Electron Microscopy (STEM) analysis revealed that significant alteration had occurred in this material during storage, resulting in the almost complete degradation of the NMP. We hypothesized that radiolytic damaged had occurred in the material. To support these concepts, we synthesized a mixed Ru-Pd nanoparticle and subjected it to irradiation in the electron microscope in an in-situ liquid cell. We demonstrated that intense radiation can lead to the decomposition of these metallic particles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Interrogating the Effects of Hydrogen on the Behavior of Planar Deformation Bands in Austenitic Stainless Steel

The effects of internal hydrogen on the deformation microstructures of 304L austenitic stainless steel have been characterized using electron backscattered diffraction (EBSD), transmission Kikuchi diffraction (TKD), high-resolution scanning transmission electron microscopy (HRSTEM), and nanoprobe diffraction. Samples, both thermally precharged with hydrogen and without thermal precharging, were subjected to tensile deformation of 5 and 20 pct true strain followed by multiple microscopic interrogations. Internal hydrogen produced widespread stacking faults within the as-forged initially unstrained material. While planar deformation bands developed with tensile strain in both the hydrogen-precharged and non-precharged material, the character of these bands changed with the presence of internal hydrogen. As shown by nanobeam diffraction and HRSTEM observations, in the absence of internal hydrogen, the bands were predominantly composed of twins, whereas for samples deformed in the presence of internal hydrogen, ε -martensite became more pronounced and the density of deformation bands increased. For the 20 pct strain condition, α '-martensite was observed at the intersection of ε -martensite bands in hydrogen-precharged samples, whereas in non-precharged samples α '-martensite was only observed along grain boundaries. We hypothesize that the increased prevalence of α '-martensite is a secondary effect of increased ε -martensite and deformation band density due to internal hydrogen and is not a signature of internal hydrogen itself.

36 MATERIALS SCIENCE↗

Synthesis and luminescence properties of Eu{sup 3+} doped porous YVO{sub 4} nanowires by chemical precipitation in nanochannels

Highlights: Black-Right-Pointing-Pointer YVO{sub 4} nanowire were synthesized by chemical precipitation in AAO. Black-Right-Pointing-Pointer All of nanowires in uniform diameter are parallelly arranged. Black-Right-Pointing-Pointer YVO{sub 4} nanowires mainly consist of polycrystalline materials. Black-Right-Pointing-Pointer YVO{sub 4}:Eu nanowires are luminescent under electron excitation. -- Abstract: Monodisperse nanowires and arrays of YVO{sub 4}:Eu{sup 3+} were synthesized by chemical precipitation method using anodic aluminum oxide template. Scanning electron microscope images indicated that YVO{sub 4}:Eu{sup 3+} nanowires are parallelly arranged, all of which are in uniform diameter of about 50 nm. High-magnification transmission electron microscopy images showed that the nanowires are composed of a lot of agglutinating particles. X-ray diffraction patterns confirmed that YVO{sub 4}:Eu{sup 3+} nanowires mainly consist of polycrystalline materials. Excitation and emission spectra of YVO{sub 4}:Eu{sup 3+} composite films were measured. The characteristic red emission peak of Eu{sup 3+} ion attributed to the {sup 5}D{sub 0}-{sup 7}F{sub 2} transition in YVO{sub 4}:Eu{sup 3+} nanowires broadened its half width.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel white light-emitting CdSe:Mn 2+ synthesized by photo-assisted chemical bath deposition

Nowadays, white light-emitting materials have attracted extensive research due to their potential applications in lighting devices and displaying images. Several semiconductor nanoparticles have been explored to achieve efficient white light emission. In this work, we report on novel white light-emitting CdSe:Mn 2+ thin films synthesized by photo-assisted chemical bath deposition. The effect of varying the Mn 2+ ion concentrations on the thin film structure, morphology, and optical properties was investigated. X-ray powder diffraction results indicated that all the films annealed at 250 degrees C possessed a cubic structure, with crystallite sizes in the range of 1-130 nm. Scanning electron microscopy demonstrated spherical nanoparticles with no significant changes with varying Mn 2+ doping concentrations. Energy dispersive X-ray spectroscopy confirmed the presence of the anticipated elements. The atomic force microscope revealed that the surface roughness has decreased with an increase in Mn 2+ ion concentrations but decreased for 0.7 %Mn 2+ . The UV-Vis absorption spectra showed absorption edges around 600-650 nm. Photoluminescence emission spectra excited at 3.8 eV (325 nm) showed emission bands at around 1.75 eV (709 nm), and 1.88 eV (659 nm), which were attributed to the band-to-band emission, and 4 T 1 ( 4 G)-> 6 A 1 ( 6 S) transitions of Mn 2+ ions, respectively, while emission bands at 2.35 eV (528 nm), and prominent at 3.17 eV (391 nm) were due to the glass substrate. The temperature-dependent luminescence showed a decrease in relative emission intensity with the increase in the operating temperature. The chromaticity colour coordinates showed white light-emitting thin films. These present findings open a new door to developing white light using CdSe thin films.

36 MATERIALS SCIENCE↗

Binary pseudo-random patterned structures for modulation transfer function calibration and resolution characterization of a full-field transmission soft x-ray microscope

We present a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) one-dimensional sequences and two-dimensional arrays as an effective method for spectral characterization in the spatial frequency domain of a broad variety of metrology instrumentation, including interferometric microscopes, scatterometers, phase shifting Fizeau interferometers, scanning and transmission electron microscopes, and at this time, x-ray microscopes. The inherent power spectral density of BPR gratings and arrays, which has a deterministic white-noise-like character, allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field of view of an instrument. We demonstrate the MTF calibration and resolution characterization over the full field of a transmission soft x-ray microscope using a BPR multilayer (ML) test sample with 2.8 nm fundamental layer thickness. We show that beyond providing a direct measurement of the microscope’s MTF, tests with the BPRML sample can be used to fine tune the instrument’s focal distance. Our results confirm the universality of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion microscopy with evolutionary-algorithm-based autofocusing

Abstract Ion microscopy is an established technique for laser focus diagnostics and the accurate, intensity-resolved measurement of laser ionization processes. In the present feasibility study, we discuss a new ion microscope design, which improves its resolution across a large range of magnifications and simplifies its operation. Instead of the common two einzel lens configuration, which is usually optimized for a fixed magnification, we propose a generic design consisting of an array of equally spaced ring electrodes, whose individually adjustable voltages are controlled by an evolutionary algorithm. In this way, we can realize aberration minimized magnifications between 25 and 100. Moreover, the algorithm can adjust the voltage settings under changing experimental conditions and facilitates autofocusing for user-defined magnification.

Haniel, Franz E.↗

Retinal microvascular and neuronal pathologies probed in vivo by adaptive optical two-photon fluorescence microscopy

The retina, behind the transparent optics of the eye, is the only neural tissue whose physiology and pathology can be non-invasively probed by optical microscopy. The aberrations intrinsic to the mouse eye, however, prevent high-resolution investigation of retinal structure and function in vivo. Optimizing the design of a two-photon fluorescence microscope (2PFM) and sample preparation procedure, we found that adaptive optics (AO), by measuring and correcting ocular aberrations, is essential for resolving putative synaptic structures and achieving three-dimensional cellular resolution in the mouse retina in vivo. Applying AO-2PFM to longitudinal retinal imaging in transgenic models of retinal pathology, we characterized microvascular lesions with sub-capillary details in a proliferative vascular retinopathy model, and found Lidocaine to effectively suppress retinal ganglion cell hyperactivity in a retinal degeneration model. Tracking structural and functional changes at high-resolution longitudinally, AO-2PFM enables microscopic investigations of retinal pathology and pharmacology for disease diagnosis and treatment in vivo.

59 BASIC BIOLOGICAL SCIENCES↗

Rapid Solidification of Magnetic Oxides

The enhanced control over microstructural evolution inherent in rapid solidification processing techniques are exploited to create novel ceramic magnetic materials. The great sensitivity of magnetic properties to local structure provides a powerful probe both for the study of structure and of microscopic solidification mechanisms. The first system studied is the SrO-Fe2O3 binary, which contains the commercially important hard magnetic compound strontium hexaferrite. The products were analyzed by transmission electron microscopy, Mossbauer spectroscopy, magnetic measurements, and differential thermal analysis. As-quenched ribbons contain high concentrations of super-paramagnetic particles, 80 to 250 Angstroms in diameter, in a glassy matrix. This suggests the possibility of crystallizing monodomain strontium hexaferrite during subsequent heat treatment, with a resulting increase in coercivity over conventionally processed ferrite magnets. That magnetic properties can be controlled in solidification processing by varying the quench rate is demonstrated.

Kalonji, G.↗

Information-rich localization microscopy through machine learning

Recent years have witnessed the development of single-molecule localization microscopy as a generic tool for sampling diverse biologically relevant information at the super-resolution level. While current approaches often rely on the target-specific alteration of the point spread function to encode the multidimensional contents of single fluorophores, the details of the point spread function in an unmodified microscope already contain rich information. Here we introduce a data-driven approach in which artificial neural networks are trained to make a direct link between an experimental point spread function image and its underlying, multidimensional parameters, and compare results with alternative approaches based on maximum likelihood estimation. To demonstrate this concept in real systems, we decipher in fixed cells both the colors and the axial positions of single molecules in regular localization microscopy data.

42 ENGINEERING↗

Transmission electron microscopy assisted in-situ joule heat dissipation study of individual InAs nanowires

Managing heat transport at nanoscale is an important and challenging task for nanodevice applications and nanostructure engineering. Herein, through in-situ engineering nanowire (NW)-electrode contacts with electron beam induced carbon deposition in a transmission electron microscope, Joule heat dissipation along individual suspended Indium Arsenide NWs is well managed to obtain pre-designed temperature profiles along NWs. The temperature profiles are experimentally determined by the breakdown site of NWs under Joule heating and breakdown temperature measurement. A model with NW-electrode contacts being well considered is proposed to describe heat transport along a NW. By fitting temperature profiles with the model, thermal conductance at NW-electrode contacts is obtained. It is found that, the temperature profile along a specific NW is mainly governed by the relative thermal conductance at the two NW-electrode contacts, which is engineered in experiments.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Controlling hydrocarbon transport and electron beam induced deposition on single layer graphene: Toward atomic scale synthesis in the scanning transmission electron microscope

Abstract Focused electron beam induced deposition (FEBID) is a direct write technique for depositing materials on a support substrate akin to 3D printing with an electron beam (e‐beam). Opportunities exist for merging this existing technique with aberration‐corrected scanning transmission electron microscopy to achieve molecular‐ or atomic‐level spatial precision. Several demonstrations have been performed using graphene as the support substrate. A common challenge that arises during this process is e‐beam‐induced hydrocarbon deposition, suggesting greater control over the sample environment is needed. Various strategies exist for cleaning graphene in situ. One of the most effective methods is to rapidly heat to high temperatures, for example, 600℃ or higher. While this can produce large areas of what appears to be atomically clean graphene, mobile hydrocarbons can still be present on the surfaces. Here, we show that these hydrocarbons are primarily limited to surface migration and demonstrate an effective method for interrupting the flow using e‐beam deposition to form corralled hydrocarbon regions. This strategy is effective for maintaining atomically clean graphene at high temperatures where hydrocarbon mobility can lead to substantial accumulation of unwanted e‐beam deposition.

36 MATERIALS SCIENCE↗

Raman and electron microscopic studies of Si{sub 1-x}Ge{sub x} alloy nanowires grown by chemical vapor deposition

Si{sub 1-x}Ge{sub x} alloy nanowires (SiGeNWs) were grown by Au-catalyzed chemical vapor deposition and studied by Raman spectroscopy, transmission electron microscopy (TEM), and energy-dispersive x-ray spectroscopy (EDS) in TEM (TEM-EDS). The relationship between the growth parameters and the structure of the SiGeNWs was clarified by systematically changing the growth conditions over a wide range. Raman and TEM-EDS results demonstrated that the SiGeNWs consist of a lower Ge composition core and a higher Ge composition shell epitaxially grown on the surface of the core. The effects of oxidation on the structure of the SiGeNWs were studied. It was found that oxidation leads to segregation of the Ge atoms at the interface between the SiGeNWs and SiO{sub 2}, which in turn results in a large inhomogeneity in Ge composition. Oxidation at a very low rate in a diluted oxygen gas atmosphere is required to avoid the formation of Ge particles and minimize the inhomogeneity.

36 MATERIALS SCIENCE↗

Human-in-the-Loop: The Future of Machine Learning in Automated Electron Microscopy

Machine learning (ML) methods are progressively gaining acceptance in the electron microscopy community for de-noising, semantic segmentation, and dimensionality reduction of data post-acquisition. The introduction of the application programming interfaces (APIs) by major instrument manufacturers now allows the deployment of ML workflows in microscopes, not only for data analytics but also for real-time decision-making and feedback for microscope operation. However, the number of use cases for real-time ML remains remarkably small. Furthermore, we discuss some considerations in designing ML-based active experiments and pose that the likely strategy for the next several years will be human-in-the-loop automated experiments (hAE). In this paradigm, the ML learning agent directly controls beam position and image and spectroscopy acquisition functions, and a human operator monitors experiment progression in real and feature space of the system and tunes the policies of the ML agent to steer the experiment toward specific objectives.

47 OTHER INSTRUMENTATION↗