Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HOSPITALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Are State-Sponsored New Radiation Therapy Facilities Economically Viable in Low- and Middle-Income Countries?

Purpose: The economic viability of establishing a state-funded radiation therapy (RT) infrastructure in low- and middle-income countries (LMICs) in accordance with the World Bank definition has been assessed through computation of a return on investment (ROI). Methods and Materials: Of the 139 LMICs, 100 were evaluated according to their RT facilities, gross national income (GNI) per capita, and employment/population ratio. The assumption was an investment of US$5 million for a basic RT center able to treat 1000 patients annually. The national breakeven points and percentage of ROI (%ROI) were calculated according to the GNI per capita and patient survival rates of 10% to 50% at 2 years. It was assumed that 50% of these patients would be of working age and that, if employed and able to work after treatment, they would contribute to the country's GNI for at least 2 years. The cumulative GNI after attaining the breakeven point until the end of the 15-year lifespan of the teletherapy unit was calculated to estimate the %ROI. The recurring and overhead costs were assumed to vary from 5.5% to 15% of the capital investment. Results: The %ROI was dependent on the GNI per capita, employment/population ratio and 2-year patient survival (all P<.001). Accordingly, none of the low-income countries would attain an ROI. If 50% of the patients survived for 2 years, the %ROI in the lower-middle and upper-middle income countries could range from 0% to 159.9% and 11.2% to 844.7%, respectively. Patient user fees to offset recurring and overhead costs could vary from “nil” to US$750, depending on state subsidies. Conclusions: Countries with a greater GNI per capita, higher employment/population ratio, and better survival could achieve a faster breakeven point, resulting in a higher %ROI. Additional factors such as user fees have also been considered. These can be tailored to the patient's ability to pay to cover the recurring costs. Certain pragmatic steps that could be undertaken to address these issues are discussed in the present study.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterization of the procoagulant phenotype of amniotic fluid across gestation in rhesus macaques and humans

Background: Amniotic fluid (AF) plays a key role in fetal development, yet the evolving composition of AF and its effects of hemostasis and thrombosis are poorly understood. Objectives: Here, we aim to determine how the evolving molecular composition of AF relates to its procoagulant properties. Methods: We analyzed the proteomes, lipidomes and procoagulant properties of AF obtained by amniocentesis from rhesus macaque and human pregnancies at gestational-age matched timepoints. Results When added to human plasma, both rhesus and human AF accelerated clotting time and fibrin generation. We identified proteomic modules associated with clotting time and enriched for coagulation-related pathways. Proteins known to be involved in hemostasis were highly correlated with each other and their intensity of expression varied across gestation in both rhesus and humans. Inhibition of contact pathway did not affect the procoagulant effect of AF. Blocking tissue factor pathway inhibitor reversed the ability of AF to block the generation of FXa. The prothrombinase activity of AF was inhibited by phospholipid inhibitors. The levels of phosphatidylserine in AF were inversely correlated with clotting time. AF promoted platelet activation and secretion in plasma. Conclusions: The addition of AF to plasma enhances coagulation in a manner dependent on phospholipids as well as the presence of proteases and other proteins that directly regulate coagulation. We describe a correlation between clotting time and expression of coagulation proteins and phosphatidylserine in both rhesus and human AF, supporting the use rhesus models for future studies of AF biology.

amniotic fluid↗

Clinical solid waste management practices and its impact on human health and environment - A review

Research highlights: > Appropriate waste management technology for safe handling and disposal of clinical solid waste. > Infectious risk assessment on unsafe handling of clinical solid waste. > Recycling-reuse program of clinical solid waste materials. > Effective sterilization technology to reduce exposure of infectious risk. - Abstract: The management of clinical solid waste (CSW) continues to be a major challenge, particularly, in most healthcare facilities of the developing world. Poor conduct and inappropriate disposal methods exercised during handling and disposal of CSW is increasing significant health hazards and environmental pollution due to the infectious nature of the waste. This article summarises a literature review into existing CSW management practices in the healthcare centers. The information gathered in this paper has been derived from the desk study of open literature survey. Numerous researches have been conducted on the management of CSW. Although, significant steps have been taken on matters related to safe handling and disposal of the clinical waste, but improper management practice is evident from the point of initial collection to the final disposal. In most cases, the main reasons of the mismanagement of CSW are the lack of appropriate legislation, lack of specialized clinical staffs, lack of awareness and effective control. Furthermore, most of the healthcare centers of the developing world have faced financial difficulties and therefore looking for cost effective disposal methods of clinical waste. This paper emphasizes to continue the recycle-reuse program of CSW materials after sterilization by using supercritical fluid carbon dioxide (SF-CO2) sterilization technology at the point of initial collection. Emphasis is on the priority to inactivate the infectious micro-organisms in CSW. In that case, waste would not pose any threat to healthcare workers. The recycling-reuse program would be carried out successfully with the non-specialized clinical staffs. Therefore, the adoption of SF-CO2 sterilization technology in management of clinical solid waste can reduce exposure to infectious waste, decrease labor, lower costs, and yield better compliance with regulatory. Thus healthcare facilities can both save money and provide a safe environment for patients, healthcare staffs and clinical staffs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Zero-Field NMR and Millitesla-SLIC Spectra for >200 Molecules from Density Functional Theory and Spin Dynamics

NMR is usually performed at magnetic fields of 1 T and above to obtain sufficient sensitivity and spectral dispersion to identify chemicals based on chemical shifts and J couplings. At lower fields, the advent of hyperpolarization technologies and sensitive detectors can address sensitivity concerns. However, it remains disputed whether spectral signatures at zero and ultra-low fields are sufficient for chemical identification. Here, we report an all–electron DFT-based batch calculation of J-coupling constants, which are used to generate J coupling NMR spectra at zero field and 6.5 mT for over 200 small molecules. In the developed computational tool chain, we first used the all-electron FHI-aims code to calculate the molecular J couplings and chemical shifts. We then fed the calculated NMR parameters into the NMR simulation package SPINACH to simulate both heteronuclear J coupling spectra at zero-field, and homonuclear J coupling spectra as spin-lock induced crossing (SLIC) spectra at ultra-low field (6.5 mT). The resulting spectra demonstrate that zero and ultra-low field NMR spectra can represent unique identifiers of chemical structure for small molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced Stability and Sensitivity for CA-125 Detection Under Microfluidic Shear Flow Using Polyethylene Glycol-Coated Biosensor

The microfluidic-based point-of-care (POC) diagnostic tool has garnered significant interest in recent years, offering rapid and cost-effective disease detection. There is a growing trend toward integrating microfluidic platforms with biosensors, aligning lab-on-a-chip technologies with POC diagnostic devices. Despite numerous efforts to incorporate biosensors into microfluidic systems, researchers have performed very limited investigations on the stability of biomarker detection when biosensors operate under microfluidic shear flow conditions. Gold nanoparticles (AuNPs) are a widely employed material in capacitive biosensors for antibody immobilization and sensitivity enhancement. However, AuNPs have limitations in providing stable detection of biomarkers within microfluidic shear flow due to their agglomeration nature. This study addresses these limitations by employing 2 kDa polyethylene glycol (PEG) as an intermediate biofunctional layer to immobilize CA-125 antibodies on gold-interdigitated electrodes for the stable and accurate detection of CA-125 antigens. The stabilities and sensitivities of AuNPs and PEG-coated biosensors are evaluated under both static drop and microfluidic shear flow conditions for CA-125 antigen detection. The experimental results demonstrate a capacitive signal response (5660 pF at 10 kHz) 2.2 times higher using the PEG-coated biosensor than the signal (2551 pF at 10 kHz) measured by the AuNP-coated biosensor in the detection of CA-125 antigen–antibody conjugation under static drop conditions, indicating the higher sensitivity of the PEG-coated biosensor. Additionally, the PEG-coated biosensor exhibits better consistency for the CA-125 antigen detection between static drop and microfluidic shear flow conditions (Cp decrease in percentage (ΔCp%↓) = 2.9% at 10 kHz) compared to the electrical signals measured using the AuNP-coated biosensor (ΔCp%↓ = 32.4% at 10 kHz), which suggests that the PEG-coated biosensor demonstrates higher stability for CA-125 antigen detection under microfluidic shear flow conditions. With these significant improvements brought by the PEG-coated biosensor, especially under microfluidic conditions, a substantial hurdle in developing electrical biosensors for POC diagnostic applications has been overcome, expediting further advancements in the field.

36 MATERIALS SCIENCE↗

Intracellular Biomacromolecule Delivery by Stimuli-Responsive Protein Vesicles Loaded by Hydrophobic Ion Pairing

Proteins can perform ideal therapeutic functions. However, their large size and significant surface hydrophilicity and charge prohibit them from reaching intracellular targets. These chemical features also render them poorly encapsulated by nanoparticles used for intracellular delivery. In this work, a novel combination of protein vesicles and hydrophobic ion pairing (HIP) was used to load protein cargo and achieve cytosolic delivery to overcome the limitations of previous protein vesicle properties. Protein vesicles are thermally self-assembling nanoparticles made from elastin-like polypeptide (ELP) fused to an arginine-rich leucine zipper and a globular protein fused to a glutamate-rich leucine zipper. To impart stimuli-responsive disassembly, physiological stability, and small size, the ELP sequence was modified to include histidine and tyrosine residues. HIP was used to load and release protein cargo requiring endosomal escape for cytosolic function. HIP vesicles enabled delivery of cytochrome c, a cytosolically active protein, and a significant reduction in viability in both a traditional two-dimensional (2D) human cancer cell line culture and a biomimetic three-dimensional (3D) organoid model of acute myeloid leukemia. By examining the uptake of positively and negatively charged fluorescent protein cargos loaded by HIP, this work revealed the necessity of HIP for cytosolic cargo delivery and how HIP loading influences protein vesicle self-assembly and disassembly using microscopy, small-angle X-ray scattering, and nanoparticle tracking analysis. HIP protein vesicles have the potential to broaden the use of intracellular proteins as therapeutics for various diseases and extend protein vesicles to deliver other biomacromolecules, as the strategy developed here resulted in the first cytosolic protein cargo delivery using protein vesicles.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamical Signatures of Thermotoga maritima Maltose-Binding Proteins Affected by Ligand Binding

Functional segregation among protein isoforms depends on the interplay of their overall structures and the molecular dynamics of these structures. Thermotoga maritima maltose-binding protein (tmMBP) isoforms show size-dependent differential binding of maltose and malto-oligomers while maintaining remarkable fold conservation. This differential behavior needs detailed characterization in native-like aqueous conditions to understand the effects of protein dynamics on ligand binding and recognition. Small-angle neutron scattering (SANS), neutron spin echo (NSE) spectroscopy, and dynamic light scattering (DLS) were used in conjunction with previously published computational molecular dynamics (MD) simulations to understand the dynamic behavior of tmMBPs experimentally. SANS provided information on the overall structure of the molecules, while NSE was used to determine the dynamics in the nanosecond time scale. Both tmMBP2 and tmMBP3 have a bidomain architecture linked with a flexible hinge, with the binding pocket sitting in the cleft between the two domains. tmMBP2 and tmMBP3 showed different solution dynamics, with the translational and rotational components dominating the dynamics of both systems, resulting in a clear differentiation of their diffusion pattern. A faster dynamics component was also observed and was attributed to segmental dynamics. Differences observed between the ligand-free (apo) and ligand-bound (holo) states of the two proteins are attributed to conformational entropy. Our results highlight the intricacies of how structure and dynamics can together shape binding to a repertoire of substrates in structurally similar proteins.

Diffusion↗

Aeromonas in South Asia: genomic insights into an environmental pathogen and reservoir of antimicrobial resistance

Aeromonads are an ecologically versatile group of bacteria that cause infections in aquatic animals and are recognised as emerging human pathogens. Despite this, our understanding of Aeromonas diversity, especially the relationship between clinical and environmental strains, remains limited. Here, we present a genomic analysis of the Aeromonas genus, comprising 1853 genomes, and a detailed comparison of clinical and environmental strains from South Asia, including 996 newly sequenced genomes from Bangladesh and India. Phylogenetic analyses revealed that Aeromonas is a highly diverse genus, with no distinct clade separating clinical and environmental isolates. We identified 28 Aeromonas species and 905 novel sequence types, comprising 72.5% of the genomes. Notably, we show a high incidence of antimicrobial resistance (AMR) genes across all isolates, including against front and last-line antibiotics. Finally, we highlight frequent misidentification of Aeromonas as Vibrio cholerae, which is relevant to cholera-endemic regions where both genera co-exist and are associated with diarrhoeal disease. Our study underscores Aeromonas as an important environmental AMR reservoir and emerging multi-species pathogen capable of spilling over into human populations.

59 BASIC BIOLOGICAL SCIENCES↗

An expanded registry of candidate cis -regulatory elements

Mammalian genomes contain millions of regulatory elements that control the complex patterns of gene expression. Previously, the ENCODE consortium mapped biochemical signals across hundreds of cell types and tissues and integrated these data to develop a registry containing 0.9 million human and 300,000 mouse candidate cis-regulatory elements (cCREs) annotated with potential functions. Here we have expanded the registry to include 2.37 million human and 967,000 mouse cCREs, leveraging new ENCODE datasets and enhanced computational methods. This expanded registry covers hundreds of unique cell and tissue types, providing a comprehensive understanding of gene regulation. Functional characterization data from assays such as STARR-seq, massively parallel reporter assay, CRISPR perturbation and transgenic mouse assays have profiled more than 90% of human cCREs, revealing complex regulatory functions. We identified thousands of novel silencer cCREs and demonstrated their dual enhancer and silencer roles in different cellular contexts. Integrating the registry with other ENCODE annotations facilitates genetic variation interpretation and trait-associated gene identification, exemplified by the identification of KLF1 as a novel causal gene for red blood cell traits. This expanded registry is a valuable resource for studying the regulatory genome and its impact on health and disease.

Moore, Jill E. [Univ. of Massachusetts, Worchester↗

Multiomics and deep learning dissect regulatory syntax in human development

Transcription factors establish cell identity during development by binding regulatory DNA in a sequence-specific manner, often promoting local chromatin accessibility and regulating gene expression1. Mapping accessible chromatin offers critical insights into transcriptional control, but available datasets for human development are restricted to bulk tissue, single organs or single modalities2. Here we present the Human Development Multiomic Atlas, a single-cell atlas of chromatin accessibility and gene expression from 817,740 fetal cells across 12 organs, spanning 203 cell types and more than 1 million candidate cis-regulatory elements, many of which exhibit organ-specific in vivo enhancer activity. Deep learning models trained to predict accessibility from local DNA sequence unravel a comprehensive lexicon of motifs that influence accessibility, including composite motifs exhibiting distinct syntactic constraints that are predicted to mediate transcription factor cooperativity. We identify ‘hard’ syntactic rules requiring precise motif spacing and orientation, ‘soft’ rules allowing flexible motif arrangements, and ubiquitous motifs inhibiting accessibility. Model-based interpretation of genetic variants reveals that disruption of motifs with positive and negative effects is associated with concordant effects on gene expression. Our work delineates how motif syntax governs cell-type-specific chromatin accessibility and provides a foundational resource for decoding cis-regulatory logic and interpreting genetic variation during human development.

59 BASIC BIOLOGICAL SCIENCES↗

Elucidating lipid nanoparticle properties and structure through biophysical analyses

Designing lipid nanoparticle (LNP) delivery systems with specific targeting, potency and minimal side effects is crucial for their clinical use. However, traditional characterization methods, such as dynamic light scattering, cannot accurately quantify physicochemical properties of LNPs and how these are influenced by the lipid composition and mixing method. Here, we structurally characterize polydisperse LNP formulations by applying emerging solution-based biophysical methods that have higher resolution and provide biophysical data beyond size and polydispersity. These techniques include sedimentation velocity analytical ultracentrifugation, field-flow fractionation followed by multiangle light scattering and size-exclusion chromatography in line with synchrotron small-angle X-ray scattering. Here, we show that LNPs have intrinsic polydispersity in size, RNA loading and shape, which depend on both the formulation technique and the lipid composition. Lastly, we predict LNP transfection in vitro and in vivo by examining the relationship between mRNA translation and physicochemical characteristics. Solution-based biophysical methods will be essential for determining LNP structure–function relationships, facilitating the creation of new design rules for LNPs.

36 MATERIALS SCIENCE↗

Structural differences between human and mouse neurons and their implementation in generative AIs

Mouse and human brains have different functions that depend on their neuronal networks. We analyzed nanometer-scale three-dimensional structures of brain tissues of the mouse medial prefrontal cortex and compared them with structures of the human anterior cingulate cortex. The obtained results indicated that mouse neuronal somata are smaller and neurites are thinner than those of human neurons. We implemented these characteristics of mouse neurons in convolutional layers of a generative adversarial network (GAN) and a denoising diffusion implicit model (DDIM), which were then subjected to image generation tasks using photo datasets of cat faces, cheese, human faces, birds, and automobiles. The mouse-mimetic GAN outperformed a standard GAN in the image generation task using the cat faces and cheese photo datasets, but underperformed for human faces and birds. The mouse-mimetic DDIM gave similar results, suggesting that the nature of the datasets affected the results. Analyses of the five datasets indicated differences in their image entropy, which should influence the number of parameters required for image generation. The preferences of the mouse-mimetic AIs coincided with the impressions commonly associated with mice. The relationship between the neuronal network and brain function should be investigated by implementing other biological findings in artificial neural networks.

generative AI↗

Three-dimensional high-content imaging of unstained soft tissue with subcellular resolution using a laboratory-based X-ray microscope

With increasing interest in studying biological systems across spatial scales—from centimeters down to nanometers—histology continues to be the gold standard for tissue imaging at cellular resolution, providing an essential bridge between macroscopic and nanoscopic analysis. However, its inherently destructive and two-dimensional nature limits its ability to capture the full three-dimensional complexity of tissue architecture. Here, we show that phase-contrast X-ray microscopy can enable three-dimensional virtual histology with subcellular resolution. This technique provides direct quantification of electron density without restrictive assumptions, allowing for direct characterization of cellular nuclei in a standard laboratory setting. By combining high spatial resolution and soft tissue contrast, with automated segmentation of cell nuclei, we demonstrated virtual Hematoxylin and Eosin (H&E) staining using machine learning-based style transfer, yielding volumetric datasets compatible with existing histopathological analysis tools. Furthermore, by integrating electron density and the sensitivity to nanometric features of the dark field contrast channel, we achieve stain-free, high-content imaging capable of distinguishing nuclei and extracellular matrix.

3D virtual histology↗

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN↗

On the Necessity of Adopting Irradiation Protocols Recommended by the Compatibility in Irradiation Research Protocols Expert Roundtable (CIRPER) in Published Research and Why It Matters to Health Physicists

The National Nuclear Security Administration (NNSA) seeks to assist and support all partners in the fields of radiobiology, health physics, radiation physics, and related areas to transition from cesium-137 chloride-based technologies that can potentially be used in an act of terrorism to X-ray technologies. The absence of information on experimental procedures, equipment, and irradiation parameters directly and negatively impacts the reproducibility and translatability of a sizable portion of radiation biology studies. It also discourages researchers from adopting new tools that eliminate the risks of a radiological dispersal device.

Stern, Warren [Brookhaven National Laboratory (BNL↗