Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Incidental Testicular Irradiation From Prostate IMRT: It All Adds Up

Purpose: To identify the technical aspects of image-guided intensity-modulated radiation therapy (IMRT) for localized prostate cancer that could result in a clinically meaningful incidental dose to the testes. Methods and Materials: We examined three sources that contribute incidental dose to the testes, namely, from internal photon scattering from IMRT small field and large pelvic nodal fields with 6 or 15 MV, from neutrons when >10-MV photons are used, and from daily image-guided fiducial-based portal imaging. Using clinical data from 10 patients who received IMRT for prostate cancer, and thermo-luminescent dosimeter measurements in phantom, we estimated the dose to the testes from each of these sources. Results: A mean testicular dose of 172 and 220 cGy results from internal photon scatter for pelvic nodal fields and 68 and 93 cGy for prostate-only fields, for 6- and 15-MV energies, respectively. For 15-MV photon energies, the mean testicular dose from neutrons is 60 cGy for pelvic fields and 31 cGy for prostate-only fields. From daily portal MV image guidance, the testes-in-field mean dose is 350 cGy, whereas the testes-out-of-field scatter dose is 16 cGy. Dosimetric comparisons between IMRT using 6-MV and 15-MV photon energies are not significantly different. Worst-case scenarios can potentially deliver cumulative incidental mean testicular doses of 630 cGy, whereas best-case scenarios can deliver only 84 cGy. Conclusions: Incidental dose to the testes from prostate IMRT can be minimized by opting to restrict the use of elective pelvic nodal fields, by choosing photon energies <10 MV, and by using the smallest port sizes necessary for daily image guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiotherapy (SBRT) for Operable Stage I Non-Small-Cell Lung Cancer: Can SBRT Be Comparable to Surgery?

Purpose: To review treatment outcomes for stereotactic body radiotherapy (SBRT) in medically operable patients with Stage I non-small-cell lung cancer (NSCLC), using a Japanese multi-institutional database. Patients and Methods: Between 1995 and 2004, a total of 87 patients with Stage I NSCLC (median age, 74 years; T1N0M0, n = 65; T2N0M0, n = 22) who were medically operable but refused surgery were treated using SBRT alone in 14 institutions. Stereotactic three-dimensional treatment was performed using noncoplanar dynamic arcs or multiple static ports. Total dose was 45-72.5 Gy at the isocenter, administered in 3-10 fractions. Median calculated biological effective dose was 116 Gy (range, 100-141 Gy). Data were collected and analyzed retrospectively. Results: During follow-up (median, 55 months), cumulative local control rates for T1 and T2 tumors at 5 years after SBRT were 92% and 73%, respectively. Pulmonary complications above Grade 2 arose in 1 patient (1.1%). Five-year overall survival rates for Stage IA and IB subgroups were 72% and 62%, respectively. One patient who developed local recurrences safely underwent salvage surgery. Conclusion: Stereotactic body radiotherapy is safe and promising as a radical treatment for operable Stage I NSCLC. The survival rate for SBRT is potentially comparable to that for surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose Conformal Radiotherapy for Patients With Stage III Non-Small-Cell Lung Carcinoma

Purpose: To determine the effectiveness of high-dose conformal radiotherapy to the involved field for patients with Stage III non-small-cell lung cancer (NSCLC). Methods and Materials: Between May 1999 and April 2006, a total of 100 consecutive patients with inoperable Stage IIIA or IIIB NSCLC with a performance score of 0 to 2 and treatment by radical radiotherapy combined with chemotherapy were included. Up to August 2002, 33 patients underwent conventional radiotherapy of 56 Gy to 66 Gy using anteroposterior opposite ports to the primary tumor and elective lymph nodes (conventional group). After September 2002, the remaining 67 patients underwent high-dose radiotherapy of 66 Gy to 84 Gy to the involved volume with three-dimensional (3-D) conformal radiotherapy (conformal group). Results: The median survival was 13.2 months (95% confidence interval [CI], 7.5-18.5 months) in the conventional group and 17.3 months (95% CI, 10.7- 24.0 months) in the conformal group. The overall survival at 3 years were 9.1% (95% CI, -0.7-18.9%) in the conventional group and 31.0% (95% CI, 18.9-43.1%) in the conformal group; the conformal group had a significantly better overall survival (p < 0.05). The radiotherapy method (hazard ratio = 0.55, p < 0.05) and performance status (hazard ratio = 1.48, p < 0.05) were shown to be statistically significant independent prognostic factors. Conclusions: Based on the practical experience reported here, 3-D conformal radiotherapy allowed dose escalation without excessive toxicity, and may improve overall survival rates for patients with Stage III NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Dose at the Site of Second Tumor Formation After Radiotherapy to the Central Nervous System

Purpose: Second tumors are an uncommon complication of multimodality treatment of childhood cancer. The present analysis attempted to correlate the dose received as a component of primary treatment and the site of the eventual development of a second tumor. Methods and Materials: We retrospectively identified 16 patients who had received radiotherapy to sites in the craniospinal axis and subsequently developed a second tumor. We compared the historical fields and port films of the primary treatment with the modern imaging of the second tumor locations. We classified the location of the second tumors as follows: in the boost field; marginal to the boost field, but in a whole-brain field; in a whole-brain field; marginal to the whole brain/primary treatment field; and distant to the field. We divided the dose received into 3 broad categories: high dose (>45 Gy), moderate dose (20-36 Gy), and low dose (<20 Gy). Results: The most common location of the second tumor was in the whole brain field (57%) and in the moderate-dose range (81%). Conclusions: Our data contradict previous publications that suggested that most second tumors develop in tissues that receive a low radiation dose. Almost all the second tumors in our series occurred in tissue within a target volume in the cranium that had received a moderate dose (20-36 Gy). These findings suggest that a major decrease in the brain volume that receives a moderate radiation dose is the only way to substantially decrease the second tumor rate after central nervous system radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying the Reproducibility of Heart Position During Treatment and Corresponding Delivered Heart Dose in Voluntary Deep Inhalation Breath Hold for Left Breast Cancer Patients Treated With External Beam Radiotherapy

Purpose: Voluntary deep inhalation breath hold (VDIBH) reduces heart dose during left breast irradiation. We present results of the first study performed to quantify reproducibility of breath hold using bony anatomy, heart position, and heart dose for VDIBH patients at treatment table. Methods and Materials: Data from 10 left breast cancer patients undergoing VDIBH whole-breast irradiation were analyzed. Two computed tomography (CT) scans, free breathing (FB) and VDIBH, were acquired to compare dose to critical structures. Pretreatment weekly kV orthogonal images and tangential ports were acquired. The displacement difference from spinal cord to sternum across the isocenter between coregistered planning Digitally Reconstructed Radiographs (DRRs) and kV imaging of bony thorax is a measure of breath hold reproducibility. The difference between bony coregistration and heart coregistration was the measured heart shift if the patient is aligned to bony anatomy. Results: Percentage of dose reductions from FB to VDIBH: mean heart dose (48%, SD 19%, p = 0.002), mean LAD dose (43%, SD 19%, p = 0.008), and maximum left anterior descending (LAD) dose (60%, SD 22%, p = 0.008). Average breath hold reproducibility using bony anatomy across the isocenter along the anteroposterior (AP) plane from planning to treatment is 1 (range, 0-3; SD, 1) mm. Average heart shifts with respect to bony anatomy between different breath holds are 2 {+-} 3 mm inferior, 1 {+-} 2 mm right, and 1 {+-} 3 mm posterior. Percentage dose changes from planning to delivery: mean heart dose (7%, SD 6%); mean LAD dose, ((9%, SD 7%)S, and maximum LAD dose, (11%, SD 11%) SD 11%, p = 0.008). Conclusion: We observed excellent three-dimensional bony registration between planning and pretreatment imaging. Reduced delivered dose to heart and LAD is maintained throughout VDIBH treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfractional Dose Variations in Intensity-Modulated Radiotherapy With Breath-Hold for Pancreatic Cancer

Purpose: To investigate the interfractional dose variations for intensity-modulated radiotherapy (RT) combined with breath-hold (BH) at end-exhalation (EE) for pancreatic cancer. Methods and Materials: A total of 10 consecutive patients with pancreatic cancer were enrolled. Each patient was fixed in the supine position on an individualized vacuum pillow with both arms raised. Computed tomography (CT) scans were performed before RT, and three additional scans were performed during the course of chemoradiotherapy using a conventional RT technique. The CT data were acquired under EE-BH conditions (BH-CT) using a visual feedback technique. The intensity-modulated RT plan, which used five 15-MV coplanar ports, was designed on the initial BH-CT set with a prescription dose of 39 Gy at 2.6 Gy/fraction. After rigid image registration between the initial and subsequent BH-CT scans, the dose distributions were recalculated on the subsequent BH-CT images under the same conditions as in planning. Changes in the dose-volume metrics of the gross tumor volume (GTV), clinical target volume (CTV = GTV + 5 mm), stomach, and duodenum were evaluated. Results: For the GTV and clinical target volume (CTV), the 95th percentile of the interfractional variations in the maximal dose, mean dose, dose covering 95% volume of the region of structure, and percentage of the volume covered by the 90% isodose line were within {+-}3%. Although the volume covered by the 39 Gy isodose line for the stomach and duodenum did not exceed 0.1 mL at planning, the volume covered by the 39 Gy isodose line for these structures was up to 11.4 cm{sup 3} and 1.8 cm{sup 3}, respectively. Conclusions: Despite variations in the gastrointestinal state and abdominal wall position at EE, the GTV and CTV were mostly ensured at the planned dose, with the exception of 1 patient. Compared with the duodenum, large variations in the stomach volume receiving high-dose radiation were observed, which might be beyond the negligible range in achieving dose escalation with intensity-modulated RT combined with BH at EE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Implanted Markers and Interportal Adjustment With Real-Time Tracking Radiotherapy System to Reduce Intrafraction Prostate Motion

Purpose: Interportal adjustment was applied to patients with prostate cancer using three fiducial markers and two sets of fluoroscopy in a real-time tumor-tracking radiotherapy (RTRT) system. The incidence of table position adjustment required to keep intrafractional uncertainty within 2.0 mm was investigated in this study. Methods and Materials: The coordinates of the center of gravity of the three fiducial markers were measured at the start of every portal irradiation in intensity-modulated radiotherapy (IMRT) with seven ports. The table position was adjusted to the planned position if the discrepancy was larger than 2.0 mm in the anterior-posterior (AP), cranial-caudal (CC), or left-right (LR) directions. In total, we analyzed 4,541 observations in 20 patients who received 70 Gy in 30 fractions (7.6 times a day on average). Results: The incidence of table position adjustment at 10 minutes from the initial setup of each treatment was 14.2%, 12.3%, and 5.0% of the observations in the AP, CC, and LR directions, respectively. The accumulated incidence of the table position adjustment was significantly higher at 10 minutes than at 2 minutes for AP (p = 0.0033) and CC (p = 0.0110) but not LR (p = 0.4296). An adjustment greater than 5 mm was required at least once in the treatment period in 11 (55%) patients. Conclusions: Interportal adjustment of table position was required in more than 10% of portal irradiations during the 10-minute period after initial setup to maintain treatment accuracy within 2.0 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New Brain Positron Emission Tomography Scanner With Semiconductor Detectors for Target Volume Delineation and Radiotherapy Treatment Planning in Patients With Nasopharyngeal Carcinoma

Purpose: We compared two treatment planning methods for stereotactic boost for treating nasopharyngeal carcinoma (NPC): the use of conventional whole-body bismuth germanate (BGO) scintillator positron emission tomography (PET{sub CONV}WB) versus the new brain (BR) PET system using semiconductor detectors (PET{sub NEW}BR). Methods and Materials: Twelve patients with NPC were enrolled in this study. [{sup 18}F]Fluorodeoxyglucose-PET images were acquired using both the PET{sub NEW}BR and the PET{sub CONV}WB system on the same day. Computed tomography (CT) and two PET data sets were transferred to a treatment planning system, and the PET{sub CONV}WB and PET{sub NEW}BR images were coregistered with the same set of CT images. Window width and level values for all PET images were fixed at 3000 and 300, respectively. The gross tumor volume (GTV) was visually delineated on PET images by using either PET{sub CONV}WB (GTV{sub CONV}) images or PET{sub NEW}BR (GTV{sub NEW}) images. Assuming a stereotactic radiotherapy boost of 7 ports, the prescribed dose delivered to 95% of the planning target volume (PTV) was set to 2000 cGy in 4 fractions. Results: The average absolute volume ({+-}standard deviation [SD]) of GTV{sub NEW} was 15.7 ml ({+-}9.9) ml, and that of GTV{sub CONV} was 34.0 ({+-}20.5) ml. The average GTV{sub NEW} was significantly smaller than that of GTV{sub CONV} (p = 0.0006). There was no statistically significant difference between the maximum dose (p = 0.0585) and the mean dose (p = 0.2748) of PTV. The radiotherapy treatment plan based on the new gross tumor volume (PLAN{sub NEW}) significantly reduced maximum doses to the cerebrum and cerebellum (p = 0.0418) and to brain stem (p = 0.0041). Conclusion: Results of the present study suggest that the new brain PET system using semiconductor detectors can provide more accurate tumor delineation than the conventional whole-body BGO PET system and may be an important tool for functional and molecular radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Assurance Peer Review Chart Rounds in 2011: A Survey of Academic Institutions in the United States

Purpose: In light of concerns regarding the quality of radiation treatment delivery, we surveyed the practice of quality assurance peer review chart rounds at American academic institutions. Methods and Materials: An anonymous web-based survey was sent to the chief resident of each institution across the United States. Results: The response rate was 80% (57/71). The median amount of time spent per patient was 2.7 minutes (range, 0.6-14.4). The mean attendance by senior physicians and residents was 73% and 93%, respectively. A physicist was consistently present at peer review rounds in 66% of departments. There was a close association between attendance by senior physicians and departmental organization: in departments with protected time policies, good attendance was 81% vs. 31% without protected time (p = 0.001), and in departments that documented attendance, attending presence was 69% vs. 29% in departments without documentation (p < 0.05). More than 80% of institutions peer review all external beam therapy courses; however, rates were much lower for other modalities (radiosurgery 58%, brachytherapy 40%-47%). Patient history, chart documentation, and dose prescription were always peer reviewed in >75% of institutions, whereas dosimetric details (beams, wedges), isodose coverage, intensity-modulated radiation therapy constraints, and dose-volume histograms were always peer reviewed in 63%, 59%, 42%, and 50% of cases, respectively. Chart rounds led to both minor (defined as a small multileaf collimator change/repeated port film) and major (change to dose prescription or replan with dosimetry) treatment changes. Whereas at the majority of institutions changes were rare (<10% of cases), 39% and 11% of institutions reported that minor and major changes, respectively, were made to more than 10% of cases. Conclusion: The implementation of peer review chart rounds seems inconsistent across American academic institutions. Brachytherapy and radiosurgical procedures are rarely reviewed. Attendance by senior physicians is variable, but it improves when scheduling clashes are avoided. The potential effect of a more thorough quality assurance peer review on patient outcomes is not known.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prone Accelerated Partial Breast Irradiation After Breast-Conserving Surgery: Five-year Results of 100 Patients

Purpose: To report the 5-year results of a prospective trial of three-dimensional conformal external beam radiotherapy (3D-CRT) to deliver accelerated partial breast irradiation in the prone position. Methods and Materials: Postmenopausal patients with Stage I breast cancer with nonpalpable tumors <2 cm, negative margins and negative nodes, positive hormone receptors, and no extensive intraductal component were eligible. The trial was offered only after eligible patients had refused to undergo standard whole-breast radiotherapy. Patients were simulated and treated on a dedicated table for prone setup. 3D-CRT was delivered at a dose of 30 Gy in five 6-Gy/day fractions over 10 days with port film verification at each treatment. Rates of ipsilateral breast failure, ipsilateral nodal failure, contralateral breast failure, and distant failure were estimated using the cumulative incidence method. Rates of disease-free, overall, and cancer-specific survival were recorded. Results: One hundred patients were enrolled in this institutional review board-approved prospective trial, one with bilateral breast cancer. One patient withdrew consent after simulation, and another patient elected to interrupt radiotherapy after receiving two treatments. Ninety-eight patients were evaluable for toxicity, and, in 1 case, both breasts were treated with partial breast irradiation. Median patient age was 68 years (range, 53-88 years); in 55% of patients the tumor size was <1 cm. All patients had hormone receptor-positive cancers: 87% of patients underwent adjuvant antihormone therapy. At a median follow-up of 64 months (range, 2-125 months), there was one local recurrence (1% ipsilateral breast failure) and one contralateral breast cancer (1% contralateral breast failure). There were no deaths due to breast cancer by 5 years. Grade 3 late toxicities occurred in 2 patients (one breast edema, one transient breast pain). Cosmesis was rated good/excellent in 89% of patients with at least 36 months follow-up. Conclusions: Five-year efficacy and toxicity of 3D-CRT delivered in prone partial breast irradiation are comparable to other experiences with similar follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Control Quantification (QCQ): A Tool to Measure the Value of Quality Control Checks in Radiation Oncology

Purpose: To quantify the error-detection effectiveness of commonly used quality control (QC) measures. Methods: We analyzed incidents from 2007-2010 logged into a voluntary in-house, electronic incident learning systems at 2 academic radiation oncology clinics. None of the incidents resulted in patient harm. Each incident was graded for potential severity using the French Nuclear Safety Authority scoring scale; high potential severity incidents (score >3) were considered, along with a subset of 30 randomly chosen low severity incidents. Each report was evaluated to identify which of 15 common QC checks could have detected it. The effectiveness was calculated, defined as the percentage of incidents that each QC measure could detect, both for individual QC checks and for combinations of checks. Results: In total, 4407 incidents were reported, 292 of which had high-potential severity. High- and low-severity incidents were detectable by 4.0 {+-} 2.3 (mean {+-} SD) and 2.6 {+-} 1.4 QC checks, respectively (P<.001). All individual checks were less than 50% sensitive with the exception of pretreatment plan review by a physicist (63%). An effectiveness of 97% was achieved with 7 checks used in combination and was not further improved with more checks. The combination of checks with the highest effectiveness includes physics plan review, physician plan review, Electronic Portal Imaging Device-based in vivo portal dosimetry, radiation therapist timeout, weekly physics chart check, the use of checklists, port films, and source-to-skin distance checks. Some commonly used QC checks such as pretreatment intensity modulated radiation therapy QA do not substantially add to the ability to detect errors in these data. Conclusions: The effectiveness of QC measures in radiation oncology depends sensitively on which checks are used and in which combinations. A small percentage of errors cannot be detected by any of the standard formal QC checks currently in broad use, suggesting that further improvements are needed. These data require confirmation with a broader incident-reporting database.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiotherapy Quality Assurance Report From Children's Oncology Group AHOD0031

Purpose: A phase 3 trial assessing response-based therapy in intermediate-risk Hodgkin lymphoma mandated real-time central review of involved field radiation therapy (IFRT) and imaging records by a centralized review center to maximize protocol compliance. We report the impact of centralized radiation therapy review on protocol compliance. Methods and Materials: Review of simulation films, port films, and dosimetry records was required before and after treatment. Records were reviewed by study-affiliated or review center–affiliated radiation oncologists. A deviation of 6% to 10% from protocol-specified dose was scored as “minor”; a deviation of >10% was “major.” A volume deviation was scored as “minor” if margins were less than specified or “major” if fields transected disease-bearing areas. Interventional review and final compliance review scores were assigned to each radiation therapy case and compared. Results: Of 1712 patients enrolled, 1173 underwent IFRT at 256 institutions in 7 countries. An interventional review was performed in 88% of patients and a final review in 98%. Overall, minor and major deviations were found in 12% and 6% of patients, respectively. Among the cases for which ≥1 pre-IFRT modification was requested by the Quality Assurance Review Center and subsequently made by the treating institution, 100% were made compliant on final review. By contrast, among the cases for which ≥1 modification was requested but not made by the treating institution, 10% were deemed compliant on final review. Conclusions: In a large trial with complex treatment pathways and heterogeneous radiation therapy fields, central review was performed in a large percentage of cases before IFRT and identified frequent potential deviations in a timely manner. When suggested modifications were performed by the institutions, deviations were almost eliminated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nodal Stage of Surgically Resected Non-Small Cell Lung Cancer and Its Effect on Recurrence Patterns and Overall Survival

Purpose: Current National Comprehensive Cancer Network guidelines recommend postoperative radiation therapy (PORT) for patients with resected non-small cell lung cancer (NSCLC) with N2 involvement. We investigated the relationship between nodal stage and local-regional recurrence (LR), distant recurrence (DR) and overall survival (OS) for patients having an R0 resection. Methods and Materials: A multi-institutional database of consecutive patients undergoing R0 resection for stage I-IIIA NSCLC from 1995 to 2008 was used. Patients receiving any radiation therapy before relapse were excluded. A total of 1241, 202, and 125 patients were identified with N0, N1, and N2 involvement, respectively; 161 patients received chemotherapy. Cumulative incidence rates were calculated for LR and DR as first sites of failure, and Kaplan-Meier estimates were made for OS. Competing risk analysis and proportional hazards models were used to examine LR, DR, and OS. Independent variables included age, sex, surgical procedure, extent of lymph node sampling, histology, lymphatic or vascular invasion, tumor size, tumor grade, chemotherapy, nodal stage, and visceral pleural invasion. Results: The median follow-up time was 28.7 months. Patients with N1 or N2 nodal stage had rates of LR similar to those of patients with N0 disease, but were at significantly increased risk for both DR (N1, hazard ratio [HR] = 1.84, 95% confidence interval [CI]: 1.30-2.59; P=.001; N2, HR = 2.32, 95% CI: 1.55-3.48; P<.001) and death (N1, HR = 1.46, 95% CI: 1.18-1.81; P<.001; N2, HR = 2.33, 95% CI: 1.78-3.04; P<.001). LR was associated with squamous histology, visceral pleural involvement, tumor size, age, wedge resection, and segmentectomy. The most frequent site of LR was the mediastinum. Conclusions: Our investigation demonstrated that nodal stage is directly associated with DR and OS but not with LR. Thus, even some patients with, N0-N1 disease are at relatively high risk of local recurrence. Prospective identification of risk factors for local recurrence may aid in selecting an appropriate population for further study of postoperative radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical and Dosimetric Factors Predicting Grade ≥2 Radiation Pneumonitis After Postoperative Radiotherapy for Patients With Non-Small Cell Lung Carcinoma

To identify clinical and dosimetric factors that would predict grade ≥2 radiation pneumonitis (RP) for patients undergoing postoperative radiation therapy (PORT) for non-small cell lung cancer (NSCLC); and to use the factors identified to generate a predictive model to quantify risk of RP in such patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A microgrid deployment framework to support drayage electrification

The electrification of heavy-duty commercial vehicles (HDCVs) is key to enhancing air quality and reducing urban air pollution, but it also imposes significant demands on an electric grid not designed for such high loads. Without complementary infrastructure, electrification may yield limited air quality improvements. This article explores the critical role of microgrids—integrating solar photovoltaics and battery storage—in supporting HDCV electrification. We present an integrated framework to identify viable microgrid sites in a given region, estimate deployment costs, and optimize power use to reduce dependence on the grid. As a case study, we apply the framework to the region around the Port of Savannah, GA, USA, demonstrating how targeted microgrid deployment can enhance grid capacity, improve energy resiliency, and support electrified freight transport.

Electrical engineering↗

Modeling of inertial deposition in scaled models of rat and human nasal airways: Towards in vitro regional dosimetry in small animals

Rodents are routinely used in inhalation toxicology tests as human surrogates. However, in vitro dosimetry tests in rodent casts are still scarce due to small rodent airways and in vitro tests to quantify sub-regional dosimetry are still impractical. We hypothesized that for inertial particles whose deposition is dominated by airflow convection (Reynolds number) and particle inertia (Stokes number), the deposition should be similar among airway replicas of different scales if their Reynolds and Stokes numbers are kept the same. In this study, we aimed to (1) numerically test the hypothesis in three airway geometries: a USP induction port, a human nose model, and a Sprague-Dawley rat nose model, and (2) find the range of applicability of this hypothesis. Five variants of the USP and human nose models and three variants of the rat nose model were tested. Inhalation rates and particle sizes were scaled to match the Reynolds number and Stokes numbers. A low-Reynolds-number k–ω model was used to resolve the airflow and a Lagrangian tracking algorithm was used to simulate the particle transport and deposition. Statistical analysis of predicted doses was conducted using ANOVA. For normal inhalation rates and particle dia- meters ranging from 0.5 to 24 mm, the deposition differences between the life-size and scaled models are insignificant for all airway geometries considered (i.e., human nose, USP, and rat nose). Furthermore, the deposition patterns and exit particle profiles also look similar among scaled models. However, deposition rates and patterns start to deviate if inhalation rates are too low, or particle sizes are too large. For the rat nose, the threshold velocity was found to be 0.71 m/s and the threshold Froude number to be 50. Results of this study provide a theoretical foundation for sub-regional in vitro dosimetry tests in small animals and for interpretation of data from inter-species or intra-species with varying body sizes.

54 ENVIRONMENTAL SCIENCES↗

Collaborating CPU and GPU for large-scale high-order CFD simulations with complex grids on the TianHe-1A supercomputer

Programming and optimizing complex, real-world CFD codes on current many-core accelerated HPC systems is very challenging, especially when collaborating CPUs and accelerators to fully tap the potential of heterogeneous systems. In this paper, with a tri-level hybrid and heterogeneous programming model using MPI + OpenMP + CUDA, we port and optimize our high-order multi-block structured CFD software HOSTA on the GPU-accelerated TianHe-1A supercomputer. HOSTA adopts two self-developed high-order compact definite difference schemes WCNS and HDCS that can simulate flows with complex geometries. We present a dual-level parallelization scheme for efficient multi-block computation on GPUs and perform particular kernel optimizations for high-order CFD schemes. The GPU-only approach achieves a speedup of about 1.3 when comparing one Tesla M2050 GPU with two Xeon X5670 CPUs. To achieve a greater speedup, we collaborate CPU and GPU for HOSTA instead of using a naive GPU-only approach. We present a novel scheme to balance the loads between the store-poor GPU and the store-rich CPU. Taking CPU and GPU load balance into account, we improve the maximum simulation problem size per TianHe-1A node for HOSTA by 2.3×, meanwhile the collaborative approach can improve the performance by around 45% compared to the GPU-only approach. Further, to scale HOSTA on TianHe-1A, we propose a gather/scatter optimization to minimize PCI-e data transfer times for ghost and singularity data of 3D grid blocks, and overlap the collaborative computation and communication as far as possible using some advanced CUDA and MPI features. Scalability tests show that HOSTA can achieve a parallel efficiency of above 60% on 1024 TianHe-1A nodes. With our method, we have successfully simulated an EET high-lift airfoil configuration containing 800M cells and China's large civil airplane configuration containing 150M cells. To our best knowledge, those are the largest-scale CPU–GPU collaborative simulations that solve realistic CFD problems with both complex configurations and high-order schemes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗