Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Self-repairing properties of OPC clinker/natural zeolite blend in water and alkali carbonate environments at 270°C

The 10 d recoveries of the mechanical properties and crack sealing of an ordinary Portland cement (OPC) clinker/natural zeolite (ferrierite (Fer)) blend modified or unmodified with silica were tested at 270°C in water and alkali carbonate environments. The recoveries of the samples depended on their modification with silica and the curing environment, but were more than 100% after repeated damage under some test conditions. The mechanical properties and phase compositions of recovered samples were evaluated by compressive strength measurements and x-ray diffraction, differential thermogravimetric analyses, Fourier transform infrared analyses and scanning electron microscopy coupled with energy dispersive x-ray spectroscopy. The sealing of 0·25 mm wide and ~2 mm deep cracks was visualised with a three-dimensional optical microscope. Fer decomposed under high-temperature alkaline conditions with the release of hydrolysates that, along with the hydrating clinker, participated in the formation of new phases contributing to strength recoveries. Here, these phases included crystalline magnesium and aluminium-containing silicates, calcium and carbonated calcium silicates and amorphous hydrates. Crack sealing was complete for the silica-modified samples and partial for unmodified ones cured in carbonate environments. The sealing was very poor for samples cured in water. Lastly, the main sealing phases included crystalline and amorphous silica, high-temperature-stable zeolites and talc mineral.

15 GEOTHERMAL ENERGY↗

Current Status of Developing Ultrafast Mega-electron-volt Electron Microsope

Recent studies of ultrafast electron microscopy (UEM) techniques show the use of short bunches of relativistic electrons is promising for the development of a new instrument for imaging various materials. Compared to conventional electron microscopes, the main advantage of UEMs with the electron energy of a few MeV is the possibility to study thick samples. We will discuss the progress of UEM design to date, the principal challenges on the way to a high resolution, and possible methods for their mitigation including the design of low-aberration magnetic optics, RF and mechanical subsystems with high stability, and precise collimation of electrons scattered in the samples.

43 PARTICLE ACCELERATORS↗

The effects of titanium impurities in N/+//P silicon solar cells

Microscopic and electrical measurements were performed to explain the degradation mechanisms associated with the presence of titanium impurities in silicon. The measurements included X-ray topography, transmission electron microscopy, and deep level transient spectroscopy, before and after processing. The results indicated the presence of TiO2 precipitates, the density of which increased after phosphorus diffusion. A majority carrier trapping level was observed in the wafers before processing. It was concluded that 10% of the Ti in the N(+)/P silicon solar cells formed electrically active centers which caused degradation of the cell junction. 14% of the remaining Ti precipitated out as TiO2, forming electrically active defects, which also caused junction degradation.

Salama, A. M.↗

Analysis of Phase Separation in Czochralski Grown Single Crystal Ilmenite

Ilmenite (FeTiOs) is a wide bandgap semiconductor with an energy gap of 2.58 eV. Ilmenite has properties suited for radiation tolerant applications, as well as a variety of other electronic applications. Single crystal ilmenite has been grown from the melt using the Czochralski method. Growth conditions have a profound effect on the microstructure of the samples. Here we present data from a variety of analytical techniques which indicate that some grown crystals exhibit distinct phase separation during growth. This phase separation is apparent for both post-growth annealed and unannealed samples. Under optical microscopy, there appear two distinct areas forming a matrix with an array of dots on order of 5 pm diameter. While appearing bright in the optical micrograph, atomic force microscope (AFM) shows the dots to be shallow pits on the surface. Magnetic force microscope (MFM) shows the dots to be magnetic. Phase identification via electron microprobe analysis (EMPA) indicates two major phases in the unannealed samples and four in the annealed samples, where the dots appear to be almost pure iron. This is consistent with micrographs taken with a scanning probe microscope used in the magnetic force mode. Samples that do not exhibit the phase separation have little or no discernible magnetic structure detectable by the MFM.

Wilkins, R.↗

Microgravity Emissions Laboratory Testing of the Light Microscopy Module Control Box Fan

The Microgravity Emissions Laboratory (MEL) was developed at the NASA Glenn Research Center for the characterization, simulation, and verification of the International Space Station (ISS) microgravity environment. This Glenn lab was developed in support of the Fluids and Combustion Facility (FCF). The MEL is a six-degrees-of-freedom inertial measurement system that can characterize the inertial response forces (emissions) of components, subrack payloads, or rack-level payloads down to 10 7g. The inertial force output data generated from the steady-state or transient operations of the test article are used with finite element analysis, statistical energy analysis, and other analysis tools to predict the on-orbit environment at specific science or rack interface locations. Customers of the MEL have used benefits in isolation performance testing in defining available attenuation during the engineering hardware design phase of their experiment s development. The Light Microscopy Module (LMM) Control Box (LCB) fan was tested in the MEL in June and July of 2002. The LMM is planned as a remotely controllable on-orbit microscope subrack facility that will be accommodated in an FCF Fluids Integrated Rack on the ISS. The disturbances measured in the MEL test resulted from operation of the air-circulation fan within the LCB. The objectives of the testing were (1) to identify an isolator to be added to the LCB fan assembly to reduce fan-speed harmonics and (2) to identify the fan-disturbance forcing functions for use in rack-response analysis of the LMM and Fluids Integrated Rack facility. This report describes the MEL, the testing process, and the results from ground-based MEL LCB fan testing.

McNelis, Anne M.↗

Micro Electron MicroProbe and Sample Analyzer

A proposed, low-power, backpack-sized instrument, denoted the micro electron microprobe and sample analyzer (MEMSA), would serve as a means of rapidly performing high-resolution microscopy and energy-dispersive x-ray spectroscopy (EDX) of soil, dust, and rock particles in the field. The MEMSA would be similar to an environmental scanning electron microscope (ESEM) but would be much smaller and designed specifically for field use in studying effects of geological alteration at the micrometer scale. Like an ESEM, the MEMSA could be used to examine uncoated, electrically nonconductive specimens. In addition to the difference in size, other significant differences between the MEMSA and an ESEM lie in the mode of scanning and the nature of the electron source.

Manohara, Harish↗

Two dimensional numerical simulations of carrier dynamics during time-resolved photoluminescence decays in two-photon microscopy measurements in semiconductors

We use two-dimensional numerical simulations to analyze high spatial resolution time-resolved spectroscopy data. This analysis is applied to two-photon excitation time-resolved photoluminescence (2PE-TRPL) but is broadly applicable to all microscopic time-resolved techniques. By solving time-dependent drift-diffusion equations, we gain insight into carrier dynamics and transport characteristics. Accurate understanding of measurement results establishes the limits and potential of the measurement and enhances its value as a characterization method. Diffusion of carriers outside of the collection volume can have a significant impact on the measured decay but can also provide an estimate of carrier mobility as well as lifetime. In addition to material parameters, the experimental conditions, such as spot size and injection level, can impact the measurement results. Although small spot size provides better resolution, it also increases the impact of diffusion on the decay; if the spot size is much smaller than the diffusion length, it impacts the entire decay. By reproducing experimental 2PE-TRPL decays, the simulations determine the bulk carrier lifetime from the data. The analysis is applied to single-crystal and heteroepitaxial CdTe, material important for solar cells, but it is also applicable to other semiconductors where carrier diffusion from the excitation volume could affect experimental measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic force microscope cantilever spring constant evaluation for higher mode oscillations: A kinetostatic method

Our previous study of the particle mass sensor has shown a large ratio (up to thousands) between the spring constants of a rectangular cantilever in higher mode vibration and at the static bending or natural mode vibration. This has been proven by us through the derived nodal point position equation. That solution is good for a cantilever with the free end in noncontact regime and the probe shifted from the end to an effective section and contacting a soft object. Our further research shows that the same nodal position equation with the proper frequency equations may be used for the same spring constant ratio estimation if the vibrating at higher mode cantilever's free end has a significant additional mass clamped to it or that end is in permanent contact with an elastic or hard measurand object (reference cantilever). However, in the latter case, the spring constant ratio is much smaller (in tens) than in other mentioned cases at equal higher (up to fourth) vibration modes. We also present the spring constant ratio for a vibrating at higher eigenmode V-shaped cantilever, which is now in wide use for atomic force microscopy. The received results on the spring constant ratio are in good (within a few percent) agreement with the theoretical and experimental data published by other researchers. The knowledge of a possible spring constant transformation is important for the proper calibration and use of an atomic force microscope with vibrating cantilever in the higher eigenmodes for measurement and imaging with enlarged resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging and quantitative data acquisition of biological cell walls with Atomic Force Microscopy and Scanning Acoustic Microscopy

This chapter demonstrates the feasibility of Atomic Force Microscopy (AFM) and High Frequency Scanning Acoustic Microscopy (HF-SAM) as tools to characterize biological tissues. Both the AFM and the SAM have shown to provide imaging (with different resolution) and quantitative elasticity measuring abilities. Plant cell walls with minimal disturbance and under conditions of their native state have been examined with these two kinds of microscopy. After descriptions of both the SAM and AFM, their special features and the typical sample preparation is discussed. The sample preparation is focused here on epidermal peels of onion scales and celery epidermis cells which were sectioned for the AFM to visualize the inner surface (closest to the plasma membrane) of the outer epidermal wall. The nm-wide cellulose microfibrils orientation and multilayer structure were clearly observed. The microfibril orientation and alignment tend to be more organized in older scales compared with younger scales. The onion epidermis cell wall was also used as a test analog to study cell wall elasticity by the AFM nanoindentation and the SAM V(z) feature. The novelty in this work was to demonstrate the capability of these two techniques to analyze isolated, single layered plant cell walls in their natural state. AFM nanoindentation was also used to probe the effects of Ethylenediaminetetraacetic acid (EDTA), and calcium ion treatment to modify pectin networks in cell walls. The results suggest a significant modulus increase in the calcium ion treatment and a slight decrease in EDTA treatment. To complement the AFM measurements, the HF-SAM was used to obtain the V(z) signatures of the onion epidermis. These measurements were focused on documenting the effect of pectinase enzyme treatment. The results indicate a significant change in the V(z) signature curves with time into the enzyme treatment. Thus AFM and HF-SAM open the door to a systematic nondestructive structure and mechanical property study of complex biological cell walls. A unique feature of this approach is that both microscopes allow the biological samples to be examined in their natural fluid (water) environment.

nanoindentation↗

Piezoelectricity and ferroelectricity of cellular polypropylene electrets films characterized by piezoresponse force microscopy

Cellular electrets polymer is a new ferroelectret material exhibiting large piezoelectricity and has attracted considerable attentions in researches and industries. Property characterization is very important for this material and current investigations are mostly on macroscopic properties. In this work, we conduct nanoscale piezoelectric and ferroelectric characterizations of cellular polypropylene (PP) films using piezoresponse force microscopy (PFM). First, both the single-frequency PFM and dual-frequency resonance-tracking PFM testings were conducted on the cellular PP film. The localized piezoelectric constant d{sub 33} is estimated to be 7–11pC/N by correcting the resonance magnification with quality factor and it is about one order lower than the macroscopic value. Next, using the switching spectroscopy PFM (SS-PFM), we studied polarization switching behavior of the cellular PP films. Results show that it exhibits the typical ferroelectric-like phase hysteresis loops and butterfly-shaped amplitude loops, which is similar to that of a poly(vinylidene fluoride) (PVDF) ferroelectric polymer film. However, both the phase and amplitude loops of the PP film are intensively asymmetric, which is thought to be caused by the nonzero remnant polarization after poling. Then, the D-E hysteresis loops of both the cellular PP film and PVDF film were measured by using the same wave form as that used in the SS-PFM, and the results show significant differences. Finally, we suggest that the ferroelectric-like behavior of cellular electrets films should be distinguished from that of typical ferroelectrics, both macroscopically and microscopically.

36 MATERIALS SCIENCE↗

Humble planar defects in SiGe nanopillars

We report a {001} planar defect found in SiGe nanopillars. The defect structure, determined by atomic-resolution electron microscopy, matches the Humble defect model proposed for diamond. We also investigate several possible variants of the Humble structure using first-principles calculations and find that the one lowest in energy is in agreement with the scanning transmission electron microscope images. The pillar composition has been analyzed with electron energy loss spectroscopy, which hints at how the defect is formed. Our results show that the structure and formation process of defects in nanostructured group IV semiconductors can be different from their bulk counterparts.

36 MATERIALS SCIENCE↗

Cross-sectional TEM specimen preparation for W/B{sub 4}C multilayer sample using FIB

A recent emergence of a cross-beam scanning electron microscopy (SEM)/focused-ion-beam (FIB) system have given choice to fabricate cross-sectional transmission electron microscopy (TEM) specimen of thin film multilayer sample. A 300 layer pair thin film multilayer sample of W/B{sub 4}C was used to demonstrate the specimen lift-out technique in very short time as compared to conventional cross-sectional sample preparation technique. To get large area electron transparent sample, sample prepared by FIB is followed by Ar{sup +} ion polishing at 2 kV with grazing incident. The prepared cross-sectional sample was characterized by transmission electron microscope.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Identification of Defects and the Origins of Surface Noise on Hydrogen–Terminated (100) Diamond

Near-surface nitrogen vacancy centres are critical to many diamond-based quantum technologies such as information processors and nanosensors. Surface defects play an important role in the design and performance of these devices. The targeted creation of defects is central to proposed bottom-up approaches to nanofabrication of quantum diamond processors, and uncontrolled surface defects may generate noise and charge trapping which degrade shallow NV device performance. Surface preparation protocols may be able to control the production of desired defects and eliminate unwanted defects, but only if their atomic structure can first be conclusively identified. This work uses a combination of scanning tunnelling microscopy (STM) imaging and first-principles simulations to identify several surface defects on H:C(100)—2 × 1 surfaces prepared using chemical vapour deposition (CVD). The atomic structure of these defects is elucidated, from which the microscopic origins of magnetic noise and charge trapping are determined based on the modeling of their paramagnetic properties and acceptor states. Rudimentary control of these deleterious properties is demonstrated through STM tip-induced manipulation of the defect structure. Furthermore, the results validate accepted models for CVD diamond growth by identifying key adsorbates responsible for the nucleation of new layers.

36 MATERIALS SCIENCE↗

Formation and dynamics of supported phospholipid membranes on a periodic nanotextured substrate

We have studied and modeled the morphology and dynamics of planar lipid bilayer assemblies supported on a textured silicon substrate that contains nano-structured features perpendicular to the plane of observation. Using a combination of characterization methods, including atomic force microscopy and quantitative fluorescence microscopy, we have discovered the bilayer assemblies are conformal to the underlying nanostructured substrate. As far as the dynamics are concnerned, the lipids freely diffuse in and out of the plane of observation while supported by the nanotextured material. In a microscopic sense, diffusion is isotropic along the patterned substrate. Macroscopically, when observed over length scales exceeding the dimensions of the nano-structured features, the diffusion appears anisotropic. The observed macroscopic anisotropy is well simulated using models of diffusion on the nanostructured surface that assume the lipids diffuse homogeneously and isotropically on the supporting nanotextured substrate.

36 MATERIALS SCIENCE↗

Dynamic recrystallization kinetics and microstructure evolution of an AZ91D magnesium alloy during hot compression

Highlights: • DRX kinetic model is developed for the aged AZ91D magnesium alloy. • The DRX behavior in different strained regions was investigated. • Four morphologies of the second phase were proposed during the hot compression tests. • The nucleation mechanisms of the DRX grains were clarified. - Abstract: The flow behavior of as-cast AZ91D magnesium alloy was evaluated by isothermal compression tests within the temperatures of 220 °C, 260 °C, 300 °C, 340 °C, and 380 °C, and the strain rates of 0.001, 0.01, 0.1, 1 and 10s{sup −1}. Based on the stress-strain curve and hyperbolic sine function, the thermal activation energy and the strain rate sensitivity of the material were determined to be 142.2726 kJ·mol{sup −1} and 0.142, respectively. The S type evolution of the dynamic recrystallization with the increasing strain that dynamic recrystallization (DRX) model obtained from stress and strain data. There was a good consistency between the proposed DRX kinetics model and microstructure observation results. Combining isothermal compression specimens with finite element and scanning electron microscopy (SEM) analysis indicated that the sample can be divided into rarely recrystallized region, partially recrystallized region and completely recrystallized region, which falls within the dense deformation zone, free deformation zone and severe deformation zone, respectively. The different forms of the β-Mg{sub 17}Al{sub 12} phase induced by compression tests were confirmed by SEM. Nucleation mechanisms of the DRX were discussed with reference to the transmission electron microscope (TEM) analysis results.

36 MATERIALS SCIENCE↗

Understanding and controlling low-temperature aging of nanocrystalline materials.

Nanocrystalline copper lms were created by both repetitive high-energy pulsed power, to produce material without internal nanotwins; and pulsed laser deposition, to produce nan- otwins. Samples of these lms were indented at ambient (298K) and cryogenic temperatures by immersion in liquid nitrogen (77K) and helium (4K). The indented samples were sectioned through the indented regions and imaged in a scanning electron microscope. Extensive grain growth was observed in the lms that contained nanotwins and were indented cryogenically. The lms that either lacked twins, or were indented under ambient conditions, were found to exhibit no substantial grain growth by visual inspection. Precession transmission elec- tron microscopy was used to con rm these ndings quantitatively, and show that 3 and 7 boundaries proliferate during grain growth, implying that these interface types play a key role in governing the extensive grain growth observed here. Molecular dynamics sim- ulations of the motion of individual grain boundaries demonstrate that speci c classes of boundaries - notably 3 and 7 - exhibit anti- or a-thermal migration, meaning that their mobilities either increase or do not change signi cantly with decreasing temperature. An in-situ cryogenic indentation capability was developed and implemented in a transmission electron microscope. Preliminary results do not show extensive cryogenic grain growth in indented copper lms. This discrepancy could arise from the signi cant di erences in con g- uration and loading of the specimen between the two approaches, and further research and development of this capability is needed.

Battaile, Corbett Chandler↗

Geological pattern formation by growth and dissolution in aqueous systems

Although many geological processes take place on time scales that are very long compared with the human experience, essentially all geological processes, fast or slow, are far from equilibrium processes. Surprisingly often, geological processes lead to the formation of quite simple and distinctive patterns, which hint at an underlying simplicity in many complex geological systems.. The ability to predict the seasons was critically important to early human society, and Halley’s prediction of the return of the comet that bears his name is still considered to be a scientific milestone. Spatial patterns have also attracted attention because of their aesthetic appeal, which depends in subtle ways on a combination of regularity and irregularity. In recent decades, rapid growth in the capabilities of digital computers has facilitated the simulation of pattern formation processes, and computer simulations have become an important tool for evaluating theoretical concepts and for scientific discovery. Computer technology in combination with other technologies such as high resolution digital cameras, scanning microprobes (atomic force microscopy AFM), confocal microscopy, and scanning tunneling microscopy (STM), for example) has facilitated the quantitative characterization of patterns over a wide range of scales and has enabled rapid advances in our ability to understand the links between large scale pattern formation and microscopic processes. The ability to quantitatively characterize patterns is important because it enables a more rigorous comparison between the predictions of computer models and real world patterns and their formation.In some cases, the idea that patterns with a high degree of regularity have simple origins appears to be justified, but in other cases, such as the formation of almost perfectly circular stone rings due to freeze-thaw cycles simple patterns appear to be the consequence of quite complex processes. In other cases, it has been shown that very simple non-linear processes can lead to extremely complicated patterns, and that some apparently complex disordered systems can be described quantitatively in terms of simple fractal models.

58 GEOSCIENCES↗

Growth, microstructure, and field-emission properties of synthesized diamond film on adamantane-coated silicon substrate by microwave plasma chemical vapor deposition

Diamond nucleation on unscratched Si surface is great importance for its growth, and detailed understanding of this process is therefore desired for many applications. The pretreatment of the substrate surface may influence the initial growth period. In this study, diamond films have been synthesized on adamantane-coated crystalline silicon {l_brace}100{r_brace} substrate by microwave plasma chemical vapor deposition from a gaseous mixture of methane and hydrogen gases without the application of a bias voltage to the substrates. Prior to adamantane coating, the Si substrates were not pretreated such as abraded/scratched. The substrate temperature was {approx}530 deg. C during diamond deposition. The deposited films are characterized by scanning electron microscopy, Raman spectrometry, x-ray diffraction, and x-ray photoelectron spectroscopy. These measurements provide definitive evidence for high-crystalline quality diamond film, which is synthesized on a SiC rather than clean Si substrate. Characterization through atomic force microscope allows establishing fine quality criteria of the film according to the grain size of nanodiamond along with SiC. The diamond films exhibit a low-threshold (55 V/{mu}m) and high current-density (1.6 mA/cm{sup 2}) field-emission (FE) display. The possible mechanism of formation of diamond films and their FE properties have been demonstrated.

36 MATERIALS SCIENCE↗