Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Identification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

High efficiency thermal storage system for solar plants (HELSOLAR). Final report

The project objective was to develop a high temperature Thermal Storage System (TES) based on graphite and able to provide both economical and technical advantages with respect to existing solutions contributing to increase the share of Concentrated Solar Plants (CSP). One of the main disadvantages of most of the renewable energy systems is their dependence to instantaneous irradiation and, thus, lack of predictability. CSP plants with thermal storage have proved to offer a good solution to this problem although still at an elevated price. The identification of alternative concepts able to work more efficiently would help to speed up the convergence of CSP towards grid parity. One way to reduce costs is to work in a range of temperatures higher than those allowed by the actual molten salt systems, currently the benchmark for TES in CSP. This requires the use of alternative energy storage materials such as graphite, as well as the utilization of Heat Transfer Fluids (HTF) other than molten salts or organic oils. The main technical challenges identified are derived from the high temperatures and significant high pressures, which pose risks such as potential graphite and insulation oxidation, creep, fatigue, corrosion and stress-corrosion in the pipes, leakages in the joints, high blower drivers’ electrical power consumption, thermal compatibility or relative deformations of the different materials. At the end, the main challenge of the project, is to identify a technical solution able to overcome all these problems but still at a competitive cost when compared to already existing thermal storage solutions. Special attention is given to all these issues during this project.

14 SOLAR ENERGY↗

Commercialization of microcavity plasma devices and arrays: Systems for VUV photolithography and nanopatterning, disinfection of drinking water and air, and biofilm deactivation for medical therapeutics

Abstract A little more than two decades after the introduction of the first microcavity plasma devices, a growing body of commercial products based on the remarkable properties of these low‐temperature, atmospheric plasmas is now available. Following a brief review of early microplasma lamp development, this article describes microplasma‐based devices and systems currently being manufactured for applications in photolithography, photopatterning, and other nanofabrication processes, such as atomic layer deposition, spectroscopic identification and analysis of materials (including wide bandgap crystals), the disinfection of drinking water in off‐grid communities, deactivating COVID‐19 and other pathogens in air and on surfaces in public spaces, and vacuum ultraviolet lamps for driving atomic clocks. The microplasma‐based treatment of otitis media in the human ear will also be discussed.

42 ENGINEERING↗

XAFS studies on battery materials: Data analysis supported by a chemometric approach

The large amount of data collected during a typical operando X-ray absorption fine structure (XAFS) experiment and the interest to thoroughly investigate and comprehend a redox process occurring in a Li-ion battery need an advanced data analysis approach. In this context, multivariate curve resolution (MCR) has gained attention as chemometric technique that allows the identification of the number of the species and their existence range without any a priori information on the studied system. Herein the call for an advanced data treatment is answered by a joint XAFS-MCR approach, able to unveil the local structural dynamics of the selected species, providing a quick and efficient data interpretation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comprehensive Experimental and Computational Spectroscopic Study of Hexacyanoferrate Complexes in Water: From Infrared to X-ray Wavelengths

We present a joint experimental and computational study of the hexacyanoferrate aqueous complexes at equilibrium in the 250 meV to 7.15 keV regime. The experiments include the vibrational spectroscopy of the cyanide ligands, the valence electronic absorption spectra and Fe 1s core hole spectra using X-ray absorption and emission techniques. These experiments are accompanied by density functional theory (DFT) based quantum mechanics/molecular mechanics (QM/MM) molecular dynamics (MD) simulations and spectroscopy calculations of the experiments spanning the IR to X-ray wavelengths. Our simulations, including explicit solvent effects, across this large energy window allows for a systematic comparison of vibrational, valence electronic and core-level spectra. The analysis reveals how the local solvation environment influences the geometric and electronic structure and impacts the line shape and intensity of the observed spectral features in the infrared, optical and X-ray wavelengths.

Ross, Matthew↗

Microbial Community Composition in Deep‐Subsurface Reservoir Fluids Reveals Natural Interwell Connectivity

Abstract The identification of natural fractures and the wells they connect is crucial for the development of geological reservoirs because it may have an important impact on reservoir model construction and hydraulic fracture propagation. In this study we investigated the use of a novel data source, the microbial community composition in the reservoir formation fluids, for identification of interwell connectivity caused by natural fractures. We verified this concept at a newly developed mesoscale enhanced geothermal system (EGS) field testbed located 4,850 ft (1,478 m) beneath ground surface at the Sanford Underground Research Facility in Lead, SD. Fluids produced at or near the EGS testbed were sampled and subjected to high‐throughput 16S rRNA gene amplicon sequencing to analyze the microbial community profile therein. Despite the typically substantial heterogeneity across the community profiles of samples spatially distributed (10 m to 1.9 km apart) throughout the site, samples from two wells at the EGS testbed showed highly similar microbial community composition, suggesting the two wells intersected the same natural fracture. This evidence of natural connectivity between the two wells at the EGS testbed was later corroborated by core log analysis and sewer camera surveys into the boreholes. Besides the field case described in this study, microbial community composition as a reservoir diagnostic tool would be applicable in a much broader context such as unconventional hydrocarbon exploitation, groundwater reservoir characterization, and environmental remediation, adding valuable “hard” data capable of pinpointing the origins of fluids unambiguously.

Zhang, Yuran↗

DISCOVERY OF A NOVA-LIKE CATACLYSMIC VARIABLE IN THE KEPLER MISSION FIELD

We announce the identification of a new cataclysmic variable (CV) star in the field of the Kepler Mission, KIC J192410.81+445934.9. This system was identified during a search for compact pulsators in the Kepler field. High-speed photometry reveals coherent large-amplitude variability with a period of 2.94 hr. Rapid, large-amplitude quasi-periodic variations are also detected on time scales of {approx}1200 s and {approx}650 s. Time-resolved spectroscopy covering one half photometric period shows shallow, broad Balmer and He I absorption lines with bright emission cores as well as strong He II and Bowen blend emission. Radial velocity variations are also observed in the Balmer and He I emission lines that are consistent with the photometric period. We therefore conclude that KIC J192410.81+445934.9 is a nova-like (NL) variable of the UX UMa class in or near the period gap, and it may belong to the rapidly growing subclass of SW Sex systems. Based on Two Micron All Sky Survey photometry and companion star models, we place a lower limit on the distance to the system of {approx}500 pc. Due to limitations of our discovery data, additional observations including spectroscopy and polarimetry are needed to confirm the nature of this object. Such data will enable further understanding of the behavior of NL variables in the critical period range of 3-4 hr, where standard CV evolutionary theory finds major problems. The presence of this system in the Kepler Mission field of view also presents a unique opportunity to obtain a continuous photometric data stream of unparalleled length and precision on a CV system.

79 ASTRONOMY AND ASTROPHYSICS↗

The Mu2e undoped CsI crystal calorimeter

We present the Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Lastly, although the readout electronics were not final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of forward proton production with incident protons and charged pions on nuclear targets at the CERN Proton Synchrotron

Measurements of the double-differential proton production cross-section d{sup 2{sigma}}/dpd{Omega} in the range of momentum 0.5 GeV/c{<=}p<8.0 GeV/c and angle 0.05 rad{<=}{theta}<0.25 rad in collisions of charged pions and protons on beryllium, carbon, aluminium, copper, tin, tantalum, and lead are presented. The data were taken with the large acceptance HARP detector in the T9 beam line of the CERN Proton Synchrotron. Incident particles were identified by an elaborate system of beam detectors and impinged on a target of 5% of a nuclear interaction length. The tracking and identification of the produced particles was performed using the forward spectrometer of the HARP experiment. Results are obtained for the double-differential cross-sections mainly at four incident beam momenta (3,5,8, and 12 GeV/c). Measurements are compared with predictions of the geant4 and mars Monte Carlo generators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Novel Authentication Management for the Data Security of Smart Grid

Bidirectional wireless communication is employed in various smart grid components such as smart meters and control and monitoring applications where security is vital. The Trusted Third Party (TTP) and wireless connectivity between the smart meter and the third party in the key management-based encryption techniques for the smart grid are expected to be totally trustworthy and dependable. In a wired/wireless medium, however, a man-in-the-middle may seek to disrupt, monitor and manipulate the network, or simply execute a replay attack, revealing its vulnerability. Recognizing this, this study presents a novel authentication management (model) comprised of two layer security schema. The first layer implements an efficient novel encryption method for secure data exchange between meters and control center with the help of two partially trusted simple servers (constitutes the TTP). In this setting, one server handles the data encryption between the meter and control center/central database, and the other server administers the random sequence of data transmission. The second layer monitors and verifies exchanged data packets among smart meters. It detects abnormal packets from suspicious sources. To implement this node-to-node authentication, One class support vector machine algorithm is proposed which takes advantages of the location information as well as the data transmission history (node identification, packet size, and data transmission frequency). This schema secures data communication, and imposes a comprehensive privacy throughout the system without considerably extending the complexity of the conventional key management scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Calibration and Use of the Canberra iSolo 300G

This procedure provides instructions for the calibration and use of the Canberra iSolo Low Background Alpha/Beta Counting System (iSolo) that is used for counting air filters and swipe samples. This detector is capable of providing radioisotope identification (e.g., it can discriminate between radon daughters and plutonium). This procedure includes step-by-step instructions for: (1) Performing periodic or daily 'Background' and 'Efficiency QC' checks; (2) Setting-up the iSolo for counting swipes and air filters; (3) Counting swipes and air filters for alpha and beta activity; and (4) Annual calibration.

61 RADIATION PROTECTION AND DOSIMETRY↗

Viability report for the ByWater Lakes project

This report presents the results from the hydrological, ecological, and renewable energy assessments conducted by Sandia National Laboratories at the ByWater Lakes site in Espanola, New Mexico for ByWater Recreation LLC and Avanyu Energy Services through the New Mexico small business assistance (NMSBA) program. Sandia's role was to assess the viability and provide perspective for enhancing the site to take advantage of renewable energy resources, improve and sustain the natural systems, develop a profitable operation, and provide an asset for the local community. Integral to this work was the identification the pertinent data and data gaps as well as making general observations about the potential issues and concerns that may arise from further developing the site. This report is informational only with no consideration with regards to the business feasibility of the various options that ByWater and Avanyu may be pursuing.

54 ENVIRONMENTAL SCIENCES↗

Repairing polycrystalline IN 100 using additive manufacturing (CRADA NFE-17-06791 Final Report)

The overall goal of this Manufacturing Demonstration Facility (MDF) technical collaboration project is to extend the use of the laser blown powder additive manufacturing process to enable the repair of polycrystalline high γ' Ni base super alloys, and to qualify the repaired parts for end use. The goal of phase 1 of this project was to evaluate the cracking susceptibility of Inconel 100 samples, and to identify parameters that would yield crack free repair deposits on representative geometries using a surrogate material as a substrate. A detailed design of experiments was performed in conjunction with thermomechanical modeling to determine processing conditions. A set of process parameters were identified which yielded minimal cracking. Further modeling was used to identify the preheat condition necessary to obtain crack free deposits. Following identification of the preheat, a furnace was integrated within the chamber of the blown powder Direct Energy Deposition (DED) system, and deposits were fabricated with on a preheated furnace. The results show that crack free deposits with dimensions 35x15x0.5 mm 3 can be fabricated. With this success obtained in phase 1 the goal of phase 2, if awarded, would be to fabricate the deposit on the actual IN 100 substrates develop heat treatment procedures and qualify the repair procedures.

36 MATERIALS SCIENCE↗

Oak Ridge National Laboratory Evaluation of Stream-Trained Models in Practice

The goal of this integration is to replicate the results from the original paper Autonomous Utility Pole Identification on different camera hardware and integrate the model into a live video stream provided by the unmanned aerial system (UAS) itself while in operation. This involves retraining the original model and validating its efficacy on multiple camera modules to select the most effective device for installation. Moreover, this integration requires writing software to handle the reception of a real-time streaming protocol stream from the UAS and run each frame through the model while allowing a user to monitor the camera feed.

97 MATHEMATICS AND COMPUTING↗

Differential white cell count by centrifugal microfluidics.

We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generation of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.

59 BASIC BIOLOGICAL SCIENCES↗

Magnetic Alignment of Pulsed Solenoids Using the Pulsed Wire Method

A unique application of the pulsed-wire measurement method has been implemented for alignment of 2.5 T pulsed solenoid magnets. The magnetic axis measurement has been shown to have a resolution of better than 25 {micro}m. The accuracy of the technique allows for the identification of inherent field errors due to, for example, the winding layer transitions and the current leads. The alignment system is developed for the induction accelerator NDCX-II under construction at LBNL, an upgraded Neutralized Drift Compression experiment for research on warm dense matter and heavy ion fusion. Precise alignment is essential for NDCX-II, since the ion beam has a large energy spread associated with the rapid pulse compression such that misalignments lead to corkscrew deformation of the beam and reduced intensity at focus. The ability to align the magnetic axis of the pulsed solenoids to within 100 pm of the induction cell axis has been demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulsed, Photonuclear-induced, Neutron Measurements of Nuclear Materials with Composite Shielding

Active measurements were performed using a 10-MeV electron accelerator with inspection objects containing various nuclear and nonnuclear materials available at the Idaho National Laboratory’s Zero Power Physics Reactor (ZPPR) facility. The inspection objects were assembled from ZPPR reactor plate materials to evaluate the measurement technologies for the characterization of plutonium, depleted uranium or highly enriched uranium shielded by both nuclear and non-nuclear materials. A series of pulsed photonuclear, time-correlated measurements were performed with unshielded calibration materials and then compared with the more complex composite shield configurations. The measurements used multiple 3He detectors that are designed to detect fission neutrons between pulses of an electron linear accelerator. The accelerator produced 10-MeV bremsstrahlung X-rays at a repetition rate of 125 Hz (8 ms between pulses) with a 4-us pulse width. All inspected objects were positioned on beam centerline and 100 cm from the X-ray source. The time-correlated data was collected in parallel using both a Los Alamos National Laboratory-designed list-mode acquisition system and a commercial multichannel scaler analyzer. A combination of different measurement configurations and data analysis methods enabled the identification of each object. This paper describes the experimental configuration, the ZPPR inspection objects used, and the various measurement and analysis results for each inspected object.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simplicity beneath Complexity: Counting Molecular Electrons Reveals Transients and Kinetics of Photodissociation Reactions

Time-resolved pump-probe gas phase X-ray scattering signals, extrapolated to zero momentum transfer, provide a measure of the number of electrons in a system, an effect that arises from the coherent addition of elastic scattering from the electrons. This allows for the identification of reactive transients and the determination of the chemical reaction kinetics without the need for extensive scattering simulations or complicated inversion of scattering data. We examine the photodissociation reaction of trimethyl amine, and identify two reaction paths upon excitation to the 3p state at 200 nm: a fast dissociation path out of the 3p state to the dimethyl amine radical (16.6±1.2%), and a slower dissociation via internal conversion to the 3s state (83.4±1.2%). The time constants for the two reactions are 640±130 fs and 74±6 ps, respectively. In addition, it is found that the transient dimethyl amine radical has a N-C bond length of 1.45±0.02 Å and a CNC bond angle of 118°±4°.

Minitti, Michael P↗