Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Radiation Aging of Cable Insulation Systems to Support Extension of Cable Electrical Assessment Techniques - CRADA 562 (Final Report)

Radiation aging (primarily gamma radiation) affects a small subset of the LV cable population based on a 40-year operation. Increasing plant operating life to 60 or 80 years will result in additional cables experiencing degradation, either from radiation or from combined thermal and radiation effects. Previous research work done by EPRI and other researchers focuses on electrical diagnostics of thermal effects. However, the electrical diagnostic response of the cable system to radiation aging is minimally understood. In order to study the electrical responses from XLPE and EPR cabling and correlate these responses with radiation dose and level of thermal exposure, gamma radiation testing was performed at Pacific Northwest National Laboratory (PNNL). This report covers the radiation testing performed at PNNL, which involved irradiation of 30-foot long cables and short witness samples. The cabling was irradiated, at room temperature, using cobalt-60 gamma-rays to intervals of 10 million rads (10 Mrads), for a maximum of 70 Mrads. The results can be used to determine cable conditions (extent of damage) more accurately and localize where the degradation exists along the length of the cable (axial location). These insights can provide operators with the options to focus repair, mitigation, or replacement efforts locally.

36 MATERIALS SCIENCE↗

NGNP Component Test Capability Design Code of Record

The Next Generation Nuclear Plant Project is conducting a trade study to select a preferred approach for establishing a capability whereby NGNP technology development testing—through large-scale, integrated tests—can be performed for critical HTGR structures, systems, and components (SSCs). The mission of this capability includes enabling the validation of interfaces, interactions, and performance for critical systems and components prior to installation in the NGNP prototype.

42 ENGINEERING↗

Multifunctional Fiber-Reinforced Polymer Composites for Damage Detection and Memory

Self-structural health monitoring (SHM) functionalities for fiber-reinforced polymer composites have become highly sought after to ensure the structural safety of newly advancing components in the automotive, civil, mechanical, and aerospace industries. This paper introduces a self-damage detection and memory (SDDM) hybrid composite material, where the structural carbon fiber tow is transformed into a piezoresistive sensor network, and the structural glass fiber operates as electrical insulation. In this study, SDDM specimens were fabricated, and tensile and impact tests were performed. The tensile tests of SDDM specimens find two distinct loading peaks: first where the carbon fiber fails, and second where the glass fiber fails. A linear correlation was observed between the carbon fiber resistance and composite strain up to a threshold, beyond which a sharp nonlinear increase in resistance occurred. The resistance then approached infinity, coinciding with the first loading peak and failure of the carbon fiber elements. This demonstrates the potential for a damage early warning threshold. Additionally, the effect of stitching the sensor tow in a zig-zag pattern over a large area was investigated using tailored fiber placement (TFP) of 1-loop, 3-loop, and 5-loop specimens. Tensile testing found that increasing the number of loops improved the sensor’s accuracy for strain sensing. Furthermore, impact tests were conducted, and as the impact energy progressively increased, the sensor resistance permanently increased. This illustrates a capability for self-memory of microdamage throughout the life cycle of the structure, potentially useful for predicting the remaining life of the composite.

Demo, Luke B. (ORCID:0000000208806522)↗

Development of joining processes and fabrication of US first wall qualification mockups for ITER.

We report here the fabrication processes used to manufacture US Party Team First Wall Qualification Mockups along with the detailed microstructural characterization and mechanical properties of the Be/CuCrZr/316L HIP bonds. A companion submission to this conference describes details of the PMTF heat flux testing and the performance of the first US FWQM.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent Performance and Ignition Tests of the pulsed SNS H- Source for 1-MW Neutron Production

After acquiring several reliable spare targets, SNS ramped the beam power from 850 kW to 1.4 MW, which required an increase in H- beam pulse length from 0.88 to 1.0 ms at 60 Hz. This increase initially produced slow 2-MHz power ramp-ups and, after several weeks of uninterrupted operation, it produced plasma outages every time the pulse length was raised above ~0.95 ms. Similar outages were previously observed towards the end of long service cycles, which were believed to indicate that the breakdown voltage of the high purity hydrogen started to exceed the induced electric fields. In 2011 the RF was reconfigured to start with 10 cycles of 1.96 MHz, which yielded the shortest H- beam rise times and apparently eliminated those plasma outages. The new, pulse-length dependent outages were eliminated by increasing the initial frequency to 1.985 MHz. However, careful frequency studies are unable to justify this frequency. In addition, the paper discusses the issues and solutions for the electron-dump voltage, which starts to sag and become unstable after several weeks of high current operation.

43 PARTICLE ACCELERATORS↗

Making Technological Timelines: Anticipatory Repair and Testing in High Performance Scientific Computing

Think of some examples of repair in everyday life. Maybe you had a car accident and took your car to the body shop. Maybe the head came off your child’s doll and you had to glue it back on. Maybe the handle of your shovel cracked and you wrapped the cracked area with duct tape to hold it together. These are examples of what could be called reactive repair, where an unexpected accident initiates a sequence of action and decision-making that ends in repair. In these cases, most of the thinking and planning surrounding repair takes place after a breakdown has been identified. This type of repair is often taken to be distinct from deliberate design, as it occurs within the context of technology that is already in operation, often has an improvisational character, and may be performed by end users or technicians rather than credentialed experts. But does repair always have to be reactive? And if not, what does this tell us about the distinction between design and repair, and their respective roles in shaping technological change? The short answer is that repair, like design, can play a dynamic and forward-looking role in shaping technological trajectories – not only stabilizing existing systems, but anticipating change and generating new technological futures.

97 MATHEMATICS AND COMPUTING↗

Mid Infra-Red Laser Sensor for Continuous Sulfur Trioxide Monitoring to Improve Coal-Fired Power Plant Performance during Flexible Operations

During the course of this project, we performed exhaustive research and development of SO3/H2SO4 sensing technology for coal-fired power plant applications (Figure 1). The development culminated in a successful field campaign of a prototype continuous real-time H2SO4 monitor at a coal-fired power plant (TRL 6) accomplishing the primary goal of the project. The developed sensors utilize tunable laser absorption spectroscopy (TLAS) operating in the mid-infrared (Mid-IR) wavelength region, which is the so-called “molecular fingerprint” region. Systems operating in the Mid-IR have orders of magnitude more sensitivity than systems operating at shorter wavelengths, such as near-infrared (NIR). However, NIR systems are more widespread due to more mature supporting technology (e.g., fiber optics, optical components, etc.). In this project, we not only produced a specific Mid-IR sensor, we also advanced Mid-IR sensor technology in general through the development and demonstration of such supporting technology. In this project, we also developed proprietary broad tuning lasers enabling the ability to effectively measure SO3, H2SO4, H2O, and SO2. Different molecular species have unique spectral signatures that can be probed with lasers operating at different wavelengths. Standard TLAS uses relatively narrow wavelength tuning distributed feedback (DFB) lasers, which can typically only target a single species with narrow features, and are not appropriate for species with broad features, such as SO3 or H2SO4. In contrast, by developing unique, broad-tuning laser technology, we were able to measure these species, as well as SO2 and H2O simultaneously. Furthermore, to enable real-time analysis at a power plant, we modified a commercially available heated gas cell to operate in the Mid-IR wavelength range and fiber coupled the lasers to enable remote delivery of the beams. To generate reference data (library spectra), our collaborators at the University of California Irvine (UCI) developed a catalytic SO3 generation facility. It is worth mentioning that representative H2SO4 and SO3 Mid-IR spectra are not a part of any publicly available database and the data generated under this project is a valuable resource in and of itself. In addition, based on the UCI study we determined that detection of SO3 is complicated by the very strong SO2 absorption. For that reason, we concentrated on H2SO4 detection. Since SO3 and H2SO4 exist in a flue gas in a state of equilibrium, which depends on temperature and humidity, by measuring water concentration and controlling the temperature of the gas cell, we developed an approach to determine SO3 concentration from the H2SO4 measurement. During the development phase of the project, we performed three testing campaigns at our collaborator’s FERCo flue gas facility with conditions representative of the coal-fired power plant (~ 40ppm SO3, 1700ppm to 2800 ppm SO2, 10% water) with the exception of particulate matter. After three test campaigns at FERCo we performed field testing at Harrison Power Station. The final system was mounted on a duct and measured H2SO4, SO2 and water. The tests were highly successful with a demonstrated real-time H2SO4 precision of 1 ppm with a 1 second update. Our collaborators at EPRI conducted an industry survey and determined that there is a very high interest for the SO3/H2SO4 monitoring in the power generation industry as well as in heavy industries in general. Furthermore, work performed by OptoKnowledge beyond the scope of this project under a synergistic DOE SBIR determined another approach to SO3 detection. We applied for Phase II on this SBIR for development a of versatile SO3/H2SO4 sensor but were not selected. We are currently looking for another opportunity to leverage all the technological advancements produced by this project including but not limited to the flue gas facility at UCI, the hardware and software developed, and relationships with FERCo, EPRI CEMTEK, and Harrison Station.

01 COAL, LIGNITE, AND PEAT↗

CHLORIDE WASHER PERFORMACE TESTING

Testing was performed to determine the chloride (Cl-) removal capabilities of the Savannah River National Laboratory (SRNL) designed and built Cl- washing equipment intended for HB-Line installation. The equipment to be deployed was tested using a cerium oxide (CeO2) based simulant in place of the 3013 plutonium oxide (PuO2) material. Two different simulant mixtures were included in this testing -- one having higher Cl- content than the other. The higher Cl- simulant was based on K-Area Interim Surveillance Inspection Program (KIS) material with Cl- content approximately equal to 70,000 ppm. The lower Cl- level simulant was comparable to KIS material containing approximately 8,000-ppm Cl- content. The performance testing results indicate that the washer is capable of reducing the Cl- content of both surrogates to below 200 ppm with three 1/2-liter washes of 0.1M sodium hydroxide (NaOH) solution. Larger wash volumes were used with similar results - all of the prescribed test parameters consistently reduced the Cl- content of the surrogate to a value below 200 ppm Cl- in the final washed surrogate material. The washer uses a 20-micron filter to retain the surrogate solids. Tests showed that 0.16-0.41% of the insoluble fraction of the starting mass passed through the 20-micron filter. The solids retention performance indicates that the fissile masses passing through the 20-micron filter should not exceed the waste acceptance criteria for discard in grout to TRU waste. It is recommended that additional testing be pursued for further verification and optimization purposes. It is likely that wash volumes smaller than those tested could still reduce the Cl- values to acceptable levels. Along with reduced wash volumes, reuse of the third wash volume (in the next run processed) should be tested as a wash solution minimization plan. A 67% reduction in the number of grouted paint pails could be realized if wash solution minimization testing returned acceptable results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗