At least 1,531 records · Page 85

Data retransmission from water survey of Canada gauging stations using the ERTS data collection system

Nine sites were selected for installation of Data Collection Platforms (DCPs) with the objective of obtaining one near real time water level reading a day from each site. Also the dependability, costs and other aspects of the system could be studied and decisions made with respect to the feasibility of operating a much larger network of DCPs. The number of transmissions received each day from the gauging stations varies from a maximum of 26 to 12 and a minimum of 10 to 3, depending on the location. Quality checks of data have indicated that the data are good. None of the nine DCPs have failed once they have been successfully activated. The experience with the ERTS data collection system has been excellent. The DCP appears to be a rugged, reliable piece of equipment. The ones installed at water survey sites have withstood temperatures less than -40 C and the antennas have withstood wind speeds of over 80 kph (50 mph) and snow loads of 0.6 m (2 ft).

Halliday, R. A.↗

Coal thickness gauge using RRAS techniques, part 1

A noncontacting sensor having a measurement range of 0 to 6 in or more, and with an accuracy of 0.5 in or better is needed to control the machinery used in modern coal mining so that the thickness of the coal layer remaining over the rock is maintained within selected bounds. The feasibility of using the radiofrequency resonance absorption (RRAS) techniques of electron magnetic resonance (EMR) and nuclear magnetic resonance (NMR) as the basis of a coal thickness gauge is discussed. The EMR technique was found, by analysis and experiments, to be well suited for this application.

Rollwitz, W. L.↗

Bakeable McLeod gauge

A low pressure gauge of the McLeod type demonstrating superior performance and measuring characteristics is described. A mercury reservoir which is kept in a vacuum at all times as well as bakeable glass components to reduce contamination are featured.

Kreisman, W. S.↗

Implications of general covariance and maximum four-dimensional Yang-Mills gauge symmetry

General covariance and maximum four-dimensional Yang-Mills gauge symmetry lead to these results: (1) gravity is characterized by a dimensionless constant F of the order of 10 to the -19th; (2) the Newtonian force is always attractive; (3) space-time has a torsion; and (4) gravitational spin-force between two protons is about 10 to the 19th times stronger than the corresponding Newtonian force. A possible experimental test is discussed.

Hsu, J. P.↗

Gravitational matter-antimatter asymmetry and four-dimensional Yang-Mills gauge symmetry

A formulation of gravity based on the maximum four-dimensional Yang-Mills gauge symmetry is studied. The theory predicts that the gravitational force inside matter (fermions) is different from that inside antimatter. This difference could lead to the cosmic separation of matter and antimatter in the evolution of the universe. Moreover, a new gravitational long-range spin-force between two fermions is predicted, in addition to the usual Newtonian force. The geometrical foundation of such a gravitational theory is the Riemann-Cartan geometry, in which there is a torsion. The results of the theory for weak fields are consistent with previous experiments.

Hsu, J. P.↗

Gauge calibration system based on piston manometer

An unbaked calibration system is described that permits absolute calibration with a piston manometer in the range 0.0002 to 6 Pa, with a probable error of 5 microPa + 0.8%, or in the range 0.00008 to 0.02 Pa, with a probable error of 2 microPa + 1%. Procedures and techniques that permit this performance are detailed. For hot-cathode ion gauges, the magnitudes of systematic corrections for envelope temperature and grid current are also indicated.

Warshawsky, I.↗

Optical crystal temperature gauge with fiber optic connections

An optical temperature gauge uses a semiconductor crystal with a band-edge shift property which is temperature dependent. An external narrow band light source provides optical excitation through a optical fiber and light energy thus passed through the crystal is conveyed by a second optical fiber to a light-to-electric transducers at an external location. The crystal can be located in cryogenic or other systems, to provide remote read-out. The light wavelength is varied (scanned) in a repetitive pattern in source with the instantaneous wavelength passing over the band-edge wavelength during each cycle of the scan. The timing of the crossover is related to the temperature of the crystal by electronic means. Several alternative elements of instrumentation are disclosed. A variation in the basic measurement apparatus is also disclosed, in which the band gap voltage of a light source such as a laser diode is evaluated at the time of band-edge crossover in the crystal and converted to a temperature value.

Sharma, M. M.↗

A highly optimized vectorized code for Monte Carlo simulations of SU(3) lattice gauge theories

New methods are introduced for improving the performance of the vectorized Monte Carlo SU(3) lattice gauge theory algorithm using the CDC CYBER 205. Structure, algorithm and programming considerations are discussed. The performance achieved for a 16(4) lattice on a 2-pipe system may be phrased in terms of the link update time or overall MFLOPS rates. For 32-bit arithmetic, it is 36.3 microsecond/link for 8 hits per iteration (40.9 microsecond for 10 hits) or 101.5 MFLOPS.

Barkai, D.↗

Measurement of heat-transfer coefficients in shock wave-turbulent boundary layer interaction regions with a multi-layered thin film heat transfer gauge

A thin film heat transfer gauge is applied to the measurement of heat transfer coefficients in the interaction regions of incident shock waves and fully developed turbulent boundary layers. It was developed to measure heat flux with high spatial resolution and fast response for wind tunnels with long flow duration. To measure the heat transfer coefficients in the interaction region in detail, experiments were performed under the conditions of Mach number = 4, total pressure = 1.2 MPa, 0.59 to approximately 0.65. Reynolds number = 1.3 to approximately 1.5 x 10 to the 7th power and incident shock angles from 17.8 to 22.8 degrees. The results show that the heat transfer coefficient changes complicatedly in the interaction region. At the beginning the interaction region, the heat transfer coefficient decreases at first, reaches its minimum value at the point where the pressure begins to increase, and then increases sharply. When the boundary layer begins to separate, even a small separation bubble causes significant changes in the heat transfer coefficient, while the pressure does not show any changes which suggests that the boundary layer begins to separate.

Hayashi, M.↗

Realizations of magnetic-monopole gauge fields - Diatoms and spin precession

It is found that the effective Hamiltonian for nuclear rotation in a diatom is equivalent to that of a charged particle in a background magnetic-monopole field. In certain cases, half-integer orbital angular momentum or non-Abelian fields occur. Furthermore, the effects of magnetic-monopole-like gauge fields can be experimentally observed in spin-resonance experiments with variable magnetic fields.

Moody, J.↗

Gamma-Ray Fuel Gauges for Airplanes

Accurate system overcomes problems of capacitance gauges. Feasibility study conducted on use of attenuation of gamma rays to measure quantities of fuel in tanks. Studies with weak Am241 59.5-keV radiation source indicate it is possible to monitor continuously fuel quantity in tanks to accuracy of better than 1 percent. Measurements also indicate easily measurable differences in physical properties and resultant attenuation characteristics of JP-4, JP-5, and Jet A fuels. Am241-based densitometers currently in use aboard some aircraft . Estimated complete system, including microprocessor and associated display devices, assembled at cost of less than $10,000 per fuel tank.

Singh, Jag J.↗

Effect of LID (Registered) processing on the microstructure and mechanical properties of Ti-6Al-4V and Ti-6Al-2Sn-4Zr-2Mo titanium foil-gauge materials

A study was undertaken to determine the mechanical properties and microstructures resulting from Liquid Interface Diffusion (LID -Registered) processing of foil-gauge specimens of Ti-6Al-4V and Ti-6Al-2Sn-4Zr-2Mo coated with varying amounts of LID material. In addition, the effects of various elevated temperature exposures on the concentration profiles of the LID alloying elements were investigated, using specimens with a narrow strip of LID material applied to the surface. Room and elevated temperature tensile properties were determined for both coated and uncoated specimens. Optical microscopy was used to examine alloy microstructures, and scanning electron microscopy to examine fracture surface morphologies. The chemical concentration profiles of the strip-coated specimens were determined with an electron microprobe.

Balckburn, Linda B.↗

A general, gauge-invariant analysis of the cosmic microwave anisotropy

A general, gauge-invariant analysis of the large-scale anisotropies in the cosmic background radiation produced by arbitrary scalar, vector, or tensor perturbations in open, closed, or flat Robertson-Walker spacetimes (with no cosmological constant) is presented. The multipole moment predictions for the scale invariant spectrum and Omega = 1 universe predicted by inflationary cosmologies are contrasted with those for other spectra and for open and closed universes. Using the measured value of the dipole moment, limits are set on the expected value of the quadrupole moment as a function of Omega for various spectra.

Abbott, L. F.↗

An experimental evaluation of apparent strain from foil strain gauges attached to carbon composite substrates

An experimental evaluation of apparent thermal strains is conducted using various combinations of substrate/gauge/attachment structure and redundant high temperature extensometry. It is found that the extensometry could either confirm independent measurements of the substrate's thermal expansion, or quantify nonzero mechanical strains resulting from uncertain material behavior and boundary conditions. Apparent strain and thermal expansion behavior data can then be used to modify the raw strain measurements in order to determine either stress producing or total strains. Limitation of the correction procedure for the three selected strain gauges is noted which is due to relatively large gauge/attachment variability.

Scott, B. R.↗

The Lewis Strain Gauge Laboratory: Status and plans

An in-house lab was established for developing, testing, and evaluating high-temperature strain gauges and to aid in in-house applications of high-temperature strain instrumentation. The lab is automated to provide computer control of oven temperatures, imposed strain, and data sampling.

Hobart, Howard F.↗

Thomas precession, Wigner rotations and gauge transformations

The exact Lorentz kinematics of the Thomas precession is discussed in terms of Wigner's O(3)-like little group which describes rotations in the Lorentz frame in which the particle is at rest. A Lorentz-covariant form for the Thomas factor is derived. It is shown that this factor is a Lorentz-boosted rotation matrix, which becomes a gauge transformation in the infinite-momentum or zero-mass limit.

Han, D.↗

Whistle Gauge Measures Flow And Temperature

Simple, rugged gauge used to measure speed of flow and temperature of steam or other gas flowing through pipes of arbitrary diameter, from 1 to 28 in. or larger. Specially designed, instrumented whistle - has no moving parts, small, nonobstruction, operates at high temperature and pressure, and cleans itself. Does not operate at zero flow, but at moderate flows (tens of meters per second) generates intense sound for use in measurements. Consists of slanted ring groove of depth D and pressure taps in wall of pipe carrying flow to be measured. Resonant wavelength of sound generated by ring groove depends primarily on size and shape of groove and approximately equal to 4D.

Shakkottai, Parthasarathy↗