Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Radiation Detection Computational Benchmark Scenarios

Modeling forms an important component of radiation detection development, allowing for testing of new detector designs, evaluation of existing equipment against a wide variety of potential threat sources, and assessing operation performance of radiation detection systems. This can, however, result in large and complex scenarios which are time consuming to model. A variety of approaches to radiation transport modeling exist with complementary strengths and weaknesses for different problems. This variety of approaches, and the development of promising new tools (such as ORNL’s ADVANTG) which combine benefits of multiple approaches, illustrates the need for a means of evaluating or comparing different techniques for radiation detection problems. This report presents a set of 9 benchmark problems for comparing different types of radiation transport calculations, identifying appropriate tools for classes of problems, and testing and guiding the development of new methods. The benchmarks were drawn primarily from existing or previous calculations with a preference for scenarios which include experimental data, or otherwise have results with a high level of confidence, are non-sensitive, and represent problem sets of interest to NA-22. From a technical perspective, the benchmarks were chosen to span a range of difficulty and to include gamma transport, neutron transport, or both and represent different important physical processes and a range of sensitivity to angular or energy fidelity. Following benchmark identification, existing information about geometry, measurements, and previous calculations were assembled. Monte Carlo results (MCNP decks) were reviewed or created and re-run in order to attain accurate computational times and to verify agreement with experimental data, when present. Benchmark information was then conveyed to ORNL in order to guide testing and development of hybrid calculations. The results of those ADVANTG calculations were then sent to PNNL for compilation. This is a report describing the details of the selected Benchmarks and results from various transport codes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test chips and ASIC qualification

A test chip set being developed to aid in the qualification of spaceborne Application Specific Integrated Circuits (ASICs) is described. The chip set consists of a process monitor for process parameter verification, a fault chip for yield analysis, a reliability chip for ASIC failure rate analysis, and total ionizing dose and single event upset chips for radiation effect analysis. The test structures contained in these chips are discussed along with representative test results.

Buehler, M. G.↗

Shuttle and Transfer Orbit Thermal Analysis and Testing of the Chandra X-Ray Observatory CCD Imaging Spectrometer Radiator Shades

Contents include the following: (1) Introduction: Chandra X-ray observatory. Advanced CCD imaging spectrometer. (2) LEO and transfer orbit analyses: Geometric modeling in TSS w/specularity. Low earth orbital heating calculations. (3) Thermal testing and LMAC. (4) Problem solving. (5) VDA overcoat analyses. (6) VDA overcoat testing and MSFC. (7) Post-MSFC test evaluation.

Sharp, John R.↗

Shock compression of liquid helium and helium-hydrogen mixtures : development of a cryogenic capability for shock compression of liquid helium on Z, final report for LDRD Project 141536.

This final report on SNL/NM LDRD Project 141536 summarizes progress made toward the development of a cryogenic capability to generate liquid helium (LHe) samples for high accuracy equation-of-state (EOS) measurements on the Z current drive. Accurate data on He properties at Mbar pressures are critical to understanding giant planetary interiors and for validating first principles density functional simulations, but it is difficult to condense LHe samples at very low temperatures (<3.5 K) for experimental studies on gas guns, magnetic and explosive compression devices, and lasers. We have developed a conceptual design for a cryogenic LHe sample system to generate quiescent superfluid LHe samples at 1.5-1.8 K. This cryogenic system adapts the basic elements of a continuously operating, self-regulating {sup 4}He evaporation refrigerator to the constraints of shock compression experiments on Z. To minimize heat load, the sample holder is surrounded by a double layer of thermal radiation shields cooled with LHe to 5 K. Delivery of LHe to the pumped-He evaporator bath is controlled by a flow impedance. The LHe sample holder assembly features modular components and simplified fabrication techniques to reduce cost and complexity to levels required of an expendable device. Prototypes have been fabricated, assembled, and instrumented for initial testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar Radiometry and Metrology, Session: Modeling and Analysis (Presentation)

This project supports the Solar America Initiative by: (1) Providing solar radiometric measurements, data, and related technical information support to NREL Measurements and Characterization Task; NREL Reliability and Durability Task; Systems and component testing and evaluation for the SAI TPPs; Requests from industry; (2) Producing credible radiometric measurements traceable to recognized standards for performance and Industry applications in accordance with IS0-17025 accreditation scope; (3) Contributing to consensus codes and standards for performance and measurement techniques for NREL R&D, SAI TPPs, and industry applications; (4) Maintain stability of the NREL solar radiation reference (absolute cavity radiometers); (5) Execute high quality detailed radiometric calibrations for broadband and spectral radiometers to meet NREL research and PV industry needs; (6) Participate in national and international consensus standards development, contributing technical expertise, data, and analysis where appropriate; (7) Provide technical information on solar radiation resource data and applications to meet research and industry needs; and (8) Transfer technology in this area to other researchers and industry via publications and conference papers and presentations.

14 SOLAR ENERGY↗

Multi Optical Transition Radiation System for ATF2

In this paper we describe the design, installation and first calibration tests of a Multi Optical Transition Radiation System in the beam diagnostic section of the Extraction (EXT) line of ATF2, close to the multi wire scanner system. This system will be a valuable tool for measuring beam sizes and emittances coming from the ATF Damping Ring. With an optical resolution of about 2 {micro}m an original OTR design (OTR1X) located after the septum at the entrance of the EXT line demonstrated the ability to measure a 5.5 {micro}m beam size in one beam pulse and to take many fast measurements. This gives the OTR the ability to measure the beam emittance with high statistics, giving a low error and a good understanding of emittance jitter. Furthermore the nearby wire scanners will be a definitive test of the OTR as a beam emittance diagnostic device. The multi-OTR system design proposed here is based on the existing OTR1X.

43 PARTICLE ACCELERATORS↗

Experimental Demonstration of X-Ray Drive Enhancement with Rugby-Shaped Hohlraums

Rugby-shaped hohlraums have been suggested as a way to enhance x-ray drive in the indirect drive approach to inertial confinement fusion. This Letter presents an experimental comparison of rugby-shaped and cylinder hohlraums used for D{sub 2} and D{sup 3}He-filled capsules implosions on the Omega laser facility, demonstrating an increase of x-ray flux by 18% in rugby-shaped hohlraums. The highest yields to date for deuterium gas implosions in indirect drive on Omega (1.5x10{sup 10} neutrons) were obtained, allowing for the first time the measurement of a DD burn history. Proton spectra measurements provide additional validation of the higher drive in rugby-shaped hohlraums.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Experimental Cell for a Radio Light Receiver

The problem of creating a receiver for incoherent microwave radiation from sources realized on the basis of ultra-wideband oscillators of chaotic oscillations and objects and surfaces “illuminated” by these sources has been considered. The structure of the device is proposed, the experimental sample is described, and its ability to register sources of incoherent microwave radiation with an integrated output power of ~2 mW at a distance of more than 100 m is shown.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparative MicroRNA Expression Patterns in Fibroblasts after Low and High Doses of Low-LET Radiation Exposure

Exposure to ionizing radiation causes DNA damage to cells, and provokes a plethora of cellular responses controlled by unique gene-directed signaling pathways. MicroRNAs (miRNAs) are small (~22-nucleotide), non-coding RNAs which functionally silence gene expression by either degrading the messages or inhibiting translation. Here we investigate radiation-dependent changes in these negative regulators by comparing the expression patterns of all 462 known human miRNAs in fibroblasts, after exposure to low (0.1 Gy) or high (2 Gy) doses of X-rays at 30 min, 2, 6 and 24 hrs post-treatment. The expression patterns of microRNAs after low and high doses of radiation show a similar qualitative down-regulation trend at early (0.5 hr) and late (24 hr) time points, with a quantitatively steeper slope following the 2 Gy exposures. Interestingly, an interruption of this downward trend is observed after the 2 Gy exposure, i.e. a significant up-regulation of microRNAs at 2 hrs, then reverting to the downward trend by 6 hrs; this interruption at the intermediate time point was not observed with the 0.1 Gy exposure. At the early time point (0.5 hr), candidate gene targets of selected down-regulated microRNAs, common to both 0.1 and 2 Gy exposures, were those functioning in chromatin remodeling. Candidate target genes of unique up-regulated microRNAs seen at a 2 hr intermediate time point, after the 2 Gy exposure only, are those involved in cell death signaling. Finally, putative target genes of down-regulated microRNAs seen at the late (24 hr) time point after either doses of radiation are those involved in the up-regulation of DNA repair, cell signaling and homeostasis. Thus we hypothesize that after radiation exposure, microRNAs acting as hub negative regulators for unique signaling pathways needed to be down-regulated so as to de-repress their target genes for the proper cellular responses, including DNA repair and cell maintenance. The unique microRNAs up-regulated at 2 hr after 2 Gy suggest the cellular response to functionally suppress the apoptotic death signaling reflex after exposure to high dose radiation. Further analyses with transcriptome and global proteomic profiling will validate the reciprocal expression of signature microRNAs selected in our radiation-exposed cells, and their candidate target gene families, and test our hypothesis that unique radiation-specific microRNAs are keys in governing signaling responses for damage control of this environmental hazard.

Maes, Olivier C.↗

Environmental Effects on Data Retention in Flash Cells

Flash technology is being utilized in fuzed munition applications and, based on the development of digital logic devices in the commercial world, usage of flash technology will increase. Antifuse technology, prevalent in non-volatile field programmable gate arrays (FPGAs), will eventually be phased out as new devices have not been developed for approximately a decade. The reliance on flash technology presents a long-term reliability issue for both DoD and NASA safety- and mission-critical applications. A thorough understanding of the data retention failure modes and statistics associated with Flash data retention is of vital concern to the fuze safety community. A key retention parameter for a flash cell is the threshold voltage (VTH), which is an indirect indicator of the amount of charge stored on the cells floating gate. This paper will present the results of our on-going tests: long-term storage at 150 C for a small population of devices, neutron radiation exposure, electrostatic discharge (ESD) testing, and the trends of large populations (over 300 devices for each condition) exposed to three difference temperatures: 25 C, 125 C, and 150 C.

Flash↗

Overview of Space Environmental Effects (SEE) Team Electrostatic Discharge (ESD) Testing

Electrostatic discharge (ESD) due to the radiation environment encountered during spaceflight missions is a serious risk that must be mitigated by careful testing and design considerations. The MSFC Space Environmental Effects (SEE) Team has world-class facilities for ESD testing along with decades of experience. The Team has recently conducted successful campaigns for several high-profile projects including Europa Clipper, Exploration Upper Stage, Lunar Gateway, Orion, Docking System, and Human Landing System. This presentation will give a brief overview of ESD causes, hazards, test methods and test deliverables.

Peter Bertone↗

The DosiMap, a new 2D scintillating dosimeter for IMRT quality assurance: Characterization of two Cerenkov discrimination methods

New radiation therapy techniques such as IMRT present significant efficiency due to their highly conformal dose distributions. A consequence of the complexity of their dose distributions (high gradients, small irradiation fields, low dose distribution, ...) is the requirement for better precision quality assurance than in classical radiotherapy in order to compare the conformation of the delivered dose with the planned dose distribution and to guarantee the quality of the treatment. Currently this control is mostly performed by matrices of ionization chambers, diode detectors, dosimetric films, portal imaging, or dosimetric gels. Another approach is scintillation dosimetry, which has been developed in the last 15 years mainly through scintillating fiber devices. Despite having many advantages over other methods it is still at an experimental level for routine dosimetry because the Cerenkov radiation produced under irradiation represents an important stem effect. A new 2D water equivalent scintillating dosimeter, the DosiMap, and two different Cerenkov discrimination methods were developed with the collaboration of the Laboratoire de Physique Corpusculaire of Caen, the Comprehensive Cancer Center Francois Baclesse, and the ELDIM Co., in the frame of the MAESTRO European project. The DosiMap consists of a plastic scintillating sheet placed inside a transparent polystyrene phantom. The light distribution produced under irradiation is recorded by a CCD camera. Our first Cerenkov discrimination technique is subtractive. It uses a chessboard pattern placed in front of the scintillator, which provides a background signal containing only Cerenkov light. Our second discrimination technique is colorimetric. It performs a spectral analysis of the light signal, which allows the unfolding of the Cerenkov radiation and the scintillation. Tests were carried out with our DosiMap prototype and the performances of the two discrimination methods were assessed. The comparison of the dose measurements performed with the DosiMap and with dosimetric films for three different irradiation configurations showed discrepancies smaller than 3.5% for a 2 mm spatial resolution. Two innovative discrimination solutions were demonstrated to separate the scintillation from the Cerenkov radiation. It was also shown that the DosiMap, which is water equivalent, fast, and user friendly, is a very promising tool for radiotherapy quality assurance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long term performance of the advanced thermal control flight experiment

The Advanced Thermal Control Flight Experiment (ATFE) is providing the first zero-g flight data for the performance of a thermal diode heat pipe and an electrical Feedback Controlled Heat Pipe (FCHP). The temperature stability derived from the melting and freezing of octadecane is also being evaluated in this experiment. Flight data for the different operational modes are compared to ground test data, and the performance of the individual components is analyzed. Also, the ATFE's long term behavior from launch through September 30, 1975, is evaluated. The temperature control capability of a thermal diode, phase change material, and FCHP was demonstrated over more than 500 days of flight operation and each of these components should be considered in future applications. Both the diode and FCHP transport more than 20 W in the normal and passive modes during maximum conditions. Up to 30 W has been carried by the FCHP when the auxiliary heater is applied. The "OFF-conductance" of the diode has improved substantially in flight. A 1.4 W decrease in backflow has been realized by more complete blockage. The variable conductance behavior of the FCHP is essentially unchanged with time and relative to ground tests. Degradation of the radiator and reservoir surfaces have resulted in a partial loss of control by the FCHP during normal mode operation; however, manual control at an elevated set point has demonstrated the FCHP's ability to provide regulated temperature control to within + or - 2 C. The same pipe when operated as a passive VCHP controlled at 35 + or - 10 C with the same test conditions.

Brennan, P. J.↗

A Pelvic Phantom for Modeling Internal Organ Motions

A pelvic phantom was developed for use in testing image-guided radiation therapy (IGRT) and adaptive applications in radiation therapy (ART) with simulating the anterior-posterior internal organ motions during prostate radiotherapy. Measurements could be done with an ionization chamber (IC) in the simulated prostate. The rectum was simulated by air-equivalent material (AEM). The volume superior to the IC placement was considered as the bladder. The extension of AEM volume could be varied. The vertical position of the IC placement could be shifted by {+-}1 cm to simulate the prostate motion parallel to the changes in bladder volume. The reality of the simulation was inspected. Three-millimeter-slice-increment computed tomography (CT) scans were taken for irradiation planning. The structure set was adapted to the phantom from a treated patient. Planning target volume was delineated according to the RTOG 0126 study. IMRT and 3D conformal radiation therapy (3D-CRT) plans were made. Prostate motion and rectum volume changes were simulated in the phantom. IC displacement was corrected by phantom shifting. The delivered dose was measured with IC in 7 cases using intensity-modulated radiation therapy (IMRT) and 3D-CRT fractions, and single square-shaped beams: anteroposterior (AP), posteroanterior (PA), and lateral (LAT). Variations from the calculated doses were slightly below 1% at IMRT and around 1% at 3D-CRT; below 4.5% at square AP beam; up to 9% at square PA beam; and around 0.5% at square LAT beam. Other authors have already shown that by using planning systems and ultrasonic and cone beam CT guidance, correction of organ motions in a real patient during prostate cancer IGRT does not have a significant dosimetric effect. The inspection of our phantom-as described here-ended with similar results. Our team suggested that our model is sufficiently realistic and can be used for IGRT and ART testing.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electromagnetic Compatibility Design, Implementation and Test of the SMAP Spacecraft to Meet Stringent L-Band Radiated Emissions Requirements

This paper describes the electromagnetic compatibility (EMC) requirements on the NASA SMAP mission, the implementation of EMC best practices at various levels of development in subsystems packaging and system level cabling harnesses, and the testing and result s of flight hardware at the sub system and spacecraft system levels.

Huang, Chi-Chien Nelson↗

Electromagnetic Compatibility Design, Implementation and Test of the SMAP Spacecraft to Meet Stringent L-Band Radiated Emissions Requirements

This paper describes the electromagnetic compatibility (EMC) requirements on the NASA SMAP mission, the implementation of EMC best practices at various levels of development in system level cabling harnesses and subsystems packaging, and the testing and results of flight hardware at the subsystem and spacecraft system levels.

Huang, Chi-Chien Nelson↗