Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Advanced Instrumentation for Transient Reactor Testing

Transient testing involves placing fuel or material into the core of specialized materials test reactors that are capable of simulating a range of design basis accidents, including reactivity insertion accidents, that require the reactor produce short bursts of intense highpower neutron flux and gamma radiation. Testing fuel behavior in a prototypic neutron environment under high-power, accident-simulation conditions is a key step in licensing nuclear fuels for use in existing and future nuclear power plants. Transient testing of nuclear fuels is needed to develop and prove the safety basis for advanced reactors and fuels. In addition, modern fuel development and design increasingly relies on modeling and simulation efforts that must be informed and validated using specially designed material performance separate effects studies. These studies will require experimental facilities that are able to support variable scale, highly instrumented tests providing data that have appropriate spatial and temporal resolution. Finally, there are efforts now underway to develop advanced light water reactor (LWR) fuels with enhanced performance and accident tolerance. These advanced reactor designs will also require new fuel types. These new fuels need to be tested in a controlled environment in order to learn how they respond to accident conditions. For these applications, transient reactor testing is needed to help design fuels with improved performance. In order to maximize the value of transient testing, there is a need for in-situ transient realtime imaging technology (e.g., the neutron detection and imaging system like the hodoscope) to see fuel motion during rapid transient excursions with a higher degree of spatial and temporal resolution and accuracy. There also exists a need for new small, compact local sensors and instrumentation that are capable of collecting data during transients (e.g., local displacements, temperatures, thermal conductivity, neutron flux, etc.).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Compact Heat Exchanger Design and Testing for Advanced Reactors and Advanced Power Cycles

The goal of the proposed research is to demonstrate the thermal hydraulic performance of innovative surface geometries in compact heat exchangers used as intermediate heat exchangers (IHXs) and recuperators for the supercritical carbon dioxide (s-CO 2 ) Brayton cycle. Printed-circuit heat exchangers (PCHEs) are the primary compact heat exchangers of interest. The overall objectives are: To develop optimized PCHE designs for different working fluid combinations including helium to s-CO 2 , liquid salt to s-CO 2 , sodium to s-CO 2 , and liquid salt to helium; To experimentally and numerically investigate thermal performance, thermal stress and failure mechanism of PCHEs under various transients; and To study diffusion bonding techniques for elevated-temperature alloys and examine post-test material integrity of the PCHEs. The project objectives were accomplished by defining and executing five different tasks corresponding to these specific objectives. The first task involved a thorough literature review and a selection of IHX candidates with different surface geometries as well as a summary of prototypic operational conditions. The second task involved optimization of PCHE design with numerical analyses of thermal-hydraulic performances and mechanical integrity. The subsequent task dealt with the development of testing facilities and engineering design of PCHE to be tested in s-CO 2 fluid conditions. The next task involved experimental investigation and validation of the thermal-hydraulic performances and thermal stress distribution of prototype PCHEs manufactured with particular surface geometries. The last task involved an investigation of diffusion bonding process and posttest destructive testing to validate mechanical design methods adopted in the design process. The experimental work utilized the two test facilities at The Ohio State University (OSU) including one existing High-Temperature Helium Test Facility (HTHF) and the newly developed s-CO 2 test loop (STL) facility and s-CO 2 test facility at University of Wisconsin – Madison (UW).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermolytic Hydrogen Generation Testing of Tank 22 Material

Savannah River National Laboratory performed hydrogen generation rate (HGR) testing using Tank 22 actual-waste sample material. The main objective of the testing was to determine the thermolysis HGR for Tank 22 material with and without added glycolate. An important use of the data from actual-waste sample testing is to validate equations for the Savannah River Site Concentration, Storage, and Transfer Facility (CSTF) HGR being developed through simulated-waste testing. Not exclusive to providing data for model validation, the desired outcome of this testing was to demonstrate a negligible thermolytic HGR in Tank 22 from the contribution of glycolate from the future Defense Waste Processing Facility (DWPF) Nitric-Glycolic Acid (NGA) flowsheet to Tank 22. Tank 22 is the pathway for glycolate in the DWPF recycle stream to enter the CSTF. Testing with added glycolate used the estimated future concentration of glycolate based on DWPF recycle with limited Sludge Receipt and Adjustment Tank and Slurry Mix Evaporator (SME) material carry-over but without glycolate mitigation in the Recycle Collection Tank. Minor objectives include the determination of the impact of the glycolate source used in testing and the inclusion of sludge solids in testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Hydraulic Experimental Test Article: Status Report for FY2019

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in an SFR. High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, the secondary system in the 18-inch Test Vessel #6, and its sodium-to-air heat exchanger will occupy the location for 18-inch Test Vessel #5 (Test Vessel #5 will not be installed), Figure 2. The design work for the facility has been completed and is currently in the procurement, manufacturing and initial testing stage. The THETA primary system, including the redan, inlet and outlet plenum, 38 kW electric core simulant heater, submerged flowmeter, pump, and all instrumentation has either been procured or is currently being tested at Argonne. The secondary sodium system for cooling the tube-side sodium of the intermediate heat exchanger has all been analyzed according to ASME code and is in the final development stages before procurement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PATO IHE DDT Test Series

This report describes one aspect of our efforts for qualifying PATO as an IHE. Specifically, we tested PATO against the DDT requirements as defined by LA-UR-15-29238 IHE Material Qualification Test Series, Section 1.1. That section states: “The purpose of the DDT test is to demonstrate that an IHE material will not undergo deflagration-to-detonation transition (DDT) under stockpile-relevant conditions of scale, confinement, and material condition. Inherent in this test design is the assumption that ignition does occur, with the onset of deflagration. The test design will incorporate large margins and replicates to account for the stochastic nature of DDT events.” Along with the primary goal of qualifying PATO, this is the first time this test standard has been executed, as such, we are ‘testing the test’ by providing details of execution, pragmatic details that could be improved, and feedback regarding scientific issues.

36 MATERIALS SCIENCE↗

Static Proof Load Testing of the Sandia SWiFT 13m Blades

Pre-flown Vestas V-27 wind turbine blades will be used at the new Sandia SWiFT test facility near Lubbock,Texas. Proof load testing the blades in the flapwise direction was needed to verify the blades are still fit for service after 20 years offield operation. Testing was conducted in Building 252(A60)at the NWTC near Boulder,Colorado, between Oct 28(arrival of blades)to Dec 4,2015(completion of testing), under NREL subtasks WE141A50 and WE161A50. Single-point, quasi-static loads were applied to the blade at three independent load stations of 5.92 m, 8.69 m, and 11.62 m, using the facility gantry crane to apply the test load in the positive flapwise direction (low pressure surface in compression). Following the flapwise load cases, a single point load was applied at the 8.69 m station in the negative edgewise direction (leading edge in compression). No damage was observed due to the introduction of the proof loads. Several small pops were heard during testing on each blade, primarily during loading at the 8.69 m station. Compliance (deflection per load) varied less than 7% between all blades for all load cases. Table 3-1 summarizes the applied loads, deflections, and compliance for each blade for the flapwise test cases. Applied test loads are the raw load cell reading minus the total tare load (combined tare load of saddle and tare load for blade self weight). Deflection here is average deflection from both LE and TE string pot data.

17 WIND ENERGY↗

REBUS-PC v1.5 Verification Test Summary

Motivated in part by its usage for analysis of the University of Missouri Research Reactor (MURR), the verification of the REBUS-PC software for θ-R-Z geometries is discussed and displayed in this manuscript. Of particular importance is to show that the eigenvalue, flux, power, and burnup outputs of the software given a user problem is correct. REBUS-PC contains many features and MURR only makes use of some of those aspects. As an example, the use of region specific cross section sets, interpolation of the cross section data with respect to burnup, and automatic movement of control rods during the fuel cycle is discussed and displayed. To demonstrate the accuracy, 22 verification tests based upon 7 physical geometries are discussed. Geometry descriptions are provided in Section 2 and the REBUS-PC results for each verification test are discussed in Section 3. These verification tests consist of both analytic problems with known solutions and a more complicated input consistent with usage of REBUS-PC on the MURR reactor itself called STRZ. In this verification test summary report, the REBUS-PC software is repeatedly demonstrated to reproduce, or closely match, the eigenvalue, flux, and power distributions from analytic test problem solutions, demonstrating that the implemented finite difference approximation in θ-R-Z is working as intended. Several additional REBUS-PC features are tested, such as control rod movement by detailed comparisons of the results against reference solutions obtained using an auxiliary implemented MatLab program. As expected, the REBUS-PC software produces results that are 100% consistent with the stated capabilities and thus the verification exercise is completed. These verification tests should be executed with each re-compilation of the REBUS-PC source and after any source code changes. All output results from any such new work should be rigorously compared against the stored output of the 22 verification tests cited in this report that forms the basis of the verification process.

97 MATHEMATICS AND COMPUTING↗

Influence of Glycolate Anion on Aqueous Corrosion in DWPF and Downstream Facilities – SCC Testing

Glycolic acid is being evaluated as an alternate reductant in the preparation of High Level Waste for the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS). During processing, the glycolic acid may not be completely consumed with small quantities of the glycolate anion being carried forward to waste facilities. The SRS liquid waste contractor requested an assessment of the influence of the glycolate anion on the corrosion of the materials of construction (MoC) throughout the waste processing system since this concern had not been previously evaluated. The influence of glycolic acid on the occurrence of stress corrosion cracking (SCC) had not been evaluated specifically in the previous testing. The present testing used electrochemical and coupon immersion testing to assess this influence. Additionally, the primary guidance on corrosion for operating DWPF with a formate-based flowsheet is based on testing that utilized test solutions with a small number of constituents. Recent testing used more complex solutions based on flowsheet development for DWPF. Additional electrochemical tests were also conducted to assess the influence of this difference on test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Of Clouds and Craters: The History of U.S. Nuclear Weapons Testing

“Now!” With that word, the Atomic Age – and the era of nuclear weapons testing – dawned. The advent of World War II’s first irresistible weapon, which had been secretly tested in the New Mexico desert in July 1945, would help hasten the inevitable: complete victory for the Allies. Codenamed Trinity, the test was the first of over a thousand conducted by the United States between 1945 and 1992. Nuclear weapons would change future clashes as well. The looming Cold War, with roots stretching all the way back to 1917, was history’s first conflict between two, major nations armed with nuclear weapons. It is clear the existence of those weapons played an important role in maintaining a tenuous peace between the United States and the Soviet Union; it is also clear nuclear weapons testing played a prominent role in fueling both the arms race and the success of deterrence. Yet, the history of nuclear weapons testing is rarely remembered, even though nuclear tests have been performed in the very recent past. Of the estimated 2,000-plus nuclear tests ever performed, the U.S. is responsible for approximately half. This is the story of U.S. full-scale nuclear weapons testing.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Causal Analysis Report for Thunder Range Block VIII Test - Management Concern

From July 24th -27th, 2018, Sandia National Laboratories (SNL) was conducting a series of explosive tests (referred to as Block VIII Tests) at Thunder Range. Thunder Range is an explosive testing range located on Kirtland Air Force Base and operated by SNL. The testing occurred on Range 7, a fragmentation range that is authorized for activities up to a maximum of 2,000 pounds net explosive weight (NEW). The maximum NEW for the Block VIII tests was 114 lbs. The specific management concern is that although the Thunder Range team identified controls to provide protection for essential personnel, those controls were not adequately evaluated before testing occurred. There were several controls in place at Thunder Range when the block VW test was executed. Engineered controls including Fire Control Point (FCP) placement, FCP structure design, and administrative controls involving communications. These controls were in place but not thoroughly evaluated for adequacy in meeting requirements related to sound pressure and fragments before the test was executed. Compliance with the remaining requirements was achieved. The lack of evaluation did not result in harm to personnel, equipment, or structures but was deemed as an opportunity to further understand how compliance with DOE-STD-1212-2012 could be better achieved with defensible evidence. The information provided in the remainder of this report discusses these controls and the deficiencies that contributed to this management concern.

42 ENGINEERING↗

Wind Turbine/Radar Interference: Offshore Test Options

This paper attempts to describe the options to expand the scope of the current Interagency Field Test & Evaluation (IFT&E) objectives to include wind turbine encroachment on agency missions for offshore wind development in the United States. The options described here build on the recently completed IFT&E test campaigns that took place in 2012 and 2013. Those tests, which looked at the CARSR, ASR-11, ARSR-4, and eight proposed mitigation technologies, found that wind turbines can significantly impact the ability of radars to detect aircraft and meet mission requirements above and near wind farms. One of the more immediate successes of the IF&E Program is that today, several of the infill radar technologies which were tested, took the results of their IF&TE performance to move well beyond Technology Readiness Level 6/7 and some have been deployed and are operating at airports in the United Kingdom (UK). As well, the UK Ministry of Defense (MOD) has deployed the replacement radar which was tested to address specific concerns with especially concerning offshore wind farms. The UK MOD continues to test and hopes to refine these systems so that identified shortfalls in surveillance capability and operations which remain can be addressed. Wind energy has been steadily growing in the U.S. With a current capacity of over 60 GW today and the expectation that this capacity will need to grow to 300 GW to meet the U.S. Department of Energy's (DOE) goal of 20% wind energy in the future, offshore wind farms are gaining more attention. The specific impacts of wind turbine interference on maritime radars have not been determined at this time. However, the DOE did fund a study conducted by the University of Texas at Austin entitled, "Assessment of Offshore Wind Farm Effects on Sea Surface, Subsurface and Airborne Electronic Systems," that focused on identifying the broader Wind-Turbine/Radar Interference: Offshore Test Options SAND2014-17870 effects of electromagnetic interference expected to be caused by offshore wind farms.' A review of that study would be worth the reader's time. And while no comprehensive field studies have been accomplished, it is worth noting that many mitigation solutions that were tested I the IFT&E Program are derived from short-range maritime radar systems. The Wind and Water Power Technologies Office (WWPTO), within the DOE Office of Energy Efficiency and Renewable Energy, supports the development, deployment, and commercialization of wind and water power technologies. This report is funded by the WWPTO.

17 WIND ENERGY↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Well RWM019

An aquifer pumping test was conducted on the Lost Lake Aquifer Zone (LLAZ) at the recently installed recovery well RWM019 in accordance with the approved test plan (Dixon, 2020). The objective of the testing was to determine baseline well performance parameters and aquifer hydraulic conductivity. This testing consisted of a step-drawdown test to determine well performance properties, a constant pumping rate aquifer test to determine aquifer hydraulic properties, and a post-test aquifer recovery monitoring period also used to estimate aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. The specific capacity of RWM019 was determined to be approximately 2.6 gpm/ft of drawdown based on the final step of the step-drawdown test. Well efficiency was inversely related to pumping rate and decreased from 87% to 81% over a pumping range of approximately 49 to 79 gpm. The aquifer head loss coefficient was determined to be 2.3 ft/ft 3 /min and the well loss coefficient was determined to be 0.05 min 2 /ft 5 .

42 ENGINEERING↗

Creep, Fatigue, and Creep-Fatigue Testing of Alloy 709 Base Metal at ORNL (FY 2021)

The testing activities and research in support of ASME Code qualification of Alloy 709, an advanced austenitic steel, are being carried out at Oak Ridge National Laboratory (ORNL), Argonne National Laboratory, and Idaho National Laboratory. ORNL has been tasked to carry out a subset of the Code Case testing for creep rupture, fatigue and creep-fatigue. The focus of the FY 2021 Code Case testing on Alloy 709 base metal at ORNL includes (1) continuing the long-term creep rupture testing on ESR1100 and AOD1100; (2) adding ESR1150-AH to the creep Code Case testing matrix; and (3) continuing fatigue and creep-fatigue Code Case testing on ESR1150- AH. This report summarizes the status and the preliminary test results of FY 2021 planned Code Case testing at ORNL.

36 MATERIALS SCIENCE↗

Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107

At the time of this testing, the Low-Activity Waste Pretreatment System (LAWPS) was to provide for the initial production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility for immobilization. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 (hereafter called AP-107) be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange) then vitrified. A small-scale test platform to demonstrate the solids filtration, Cs removal, and LAW vitrification was constructed and installed at Pacific Northwest National Laboratory. Bench-scale ion exchange testing with approximately 9 L of AP-107 supernate was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Batch 2081000057). The ion exchange media was first tested with simulant and was previously described. This report describes the Cs ion exchange batch contact and column test results with the AP-107 tank waste. Batch contact testing helps to evaluate CST performance on tank waste supernate prior to processing it in the ion exchange columns. Batch contacts were performed with the waste at four Cs concentrations at a phase ratio of 200 (liquid volume to exchanger mass) with AP-107. The distribution coefficient (K d ) at the equilibrium condition of 8.57 µg Cs/mL (AP-107 feed condition) was determined to be 669 mL AP-107/g CST. With a CST bed density of 1.00 g/mL, this K d corresponded to a predicted 50% Cs breakthrough of 669 bed volumes (BVs). The Cs load capacity at the equilibrium feed condition was determined to be 7.5 mg Cs/g dry CST. The column testing was prototypic to the intended LAWPS operations in a lead-lag column format, although on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column at ~2.2 BV/h. Loading continued until the lag column reached the WTP waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and 137 Cs concentrations). For AP-107, the WAC is 0.114% of the influent 137 Cs concentration; this required a Cs decontamination factor of 876. The Cs effluent from the lag column reached the WAC after processing ~410 BVs. To keep the subsequent product effluent below the WAC, a replacement lag column was prepared, the lead column was removed from service (after processing a total of 471 BVs), the lag column was put into the lead column position, and the replacement lag column was installed. Feed processing continued and after another ~290 BVs the Cs effluent from the lag column again exceeded the WAC. In both cases, the lead columns only reached 25% Cs breakthrough before removal. Although 50% Cs breakthrough was not reached, this value was estimated and averaged based on extrapolation of the loading curves (640 BVs) and agreed within 4% of the predicted 50% Cs breakthrough from batch contact test results (669 BVs). Table ES.1 summarizes the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Digital Twin Predictive Model for PWR Components: Updates on Multi Times Series Temperature Prediction Using Recurrent Neural Network, DMW Fatigue Tests, System Level Thermal-Mechanical-Stress Analysis

The long-term operation (LTO) of nuclear power plant (NPP) beyond their original design life of 40 years, can lead to more material damage associated with cyclic fatigue under thermal-mechanical loading cycles and associated long-term exposure of reactor material to the deleterious reactor-coolant environments. However, under this LTO condition the reactor components can still safely operate but may require more frequent Nondestructive Evaluation (NDE) of reactor components. Frequent NDE requirement may lead to frequent shutdown of the NPP. This in turn can lead to power outage and additional NDE-inspection-cost related economic loss. The economic loss can be minimized by reducing uncertainty in life estimation of safety-critical pressure boundary components and by implementing more digital approach such as by using upcoming digital-twin (DT) technology for predicting the structural states (e.g., time and location dependent inside/outside thickness temperature, stress, strain, plastic deformation, etc.) and associated fatigue life of a component in real time. Towards this goal Argonne National Laboratory (ANL) with the sponsorship of DOE Light Water Reactor Sustainability (LWRS) program is working on the development of a DT framework that can be used for real time environmental fatigue prediction of reactor components. The DT framework is based on limited experiment-data, Artificial-intelligence (AI) – Machine-Learning (ML) - Deep-Learning (DL) based techniques and Multiphysics-computational-mechanics such as finite element (FE) based modeling tools. Towards this overall goal, following are some of the major contributions made during the FY21: 1) Multiple 82/182 dissimilar metal weld (DMW) specimens (both solid-weld and joint-weld representing the actual reactor multi-metal nozzles) were fatigue tested. The resulting fatigue lives were compared to the NUREG-6909 based best-fit and design fatigue curves. Additionally, the results of 52/152 DMW fatigue specimens (which were recently tested at Republic of Korea under the sponsorship of International Nuclear Energy Research Initiative - INERI program) were compared to the NUREG-6909 based best-fit and design fatigue curves. From the comparison of 82/182 and 52/152 DMW test data with NUREG-6909 best-fit curve, most of the reported test data fall way away from the NUREG-6909 suggested best-fit or mean curve. The NUREG-6909 suggested best-fit curve is the best-fit curve of austenitic stainless steel and due to lack of enough data on Nickel-based welds, this is currently being used for predicting the life of Nickel-alloy-based welded components. However, the above observation may require higher scaling factor (e.g., ASME suggested factor of 20 on cycles rather than the current NUREG-6909 suggested factor of 12 on cycles) for scaling the austenitic-stainless-steel best-fit-curve for estimating the design or safe-life of a welded component. Accordingly, for example, if a DMW component experience a strain amplitude of 0.6% the PWR-water life of the component would be 52 cycles instead of 85 cycles. However, more DMW tests are required to further ascertain the above-mentioned observations. 2) A system level CAD and finite element model were developed which consists of reactor pressure vessel (RPV), part of steam generator (SG), part of pressurizer (PRZ), hot leg (HL), and surge line (SL). This is with detailed nozzle geometry and thermal-mechanical material properties of different metals to simulate realistic thermal-mechanical stress under connected system global thermal-mechanical boundary conditions. 3) Different system level heat transfer analyses were performed with estimation of relevant heat transfer coefficients. The resulting data were used in subsequent system level thermal-mechanical stress analysis and for generating spatial-temporal training and validation data for a system level digital-twin based temperature predictor. Transient heat transfer analyses were performed considering thermal boundary condition under design-basis (DB) loading and EDF (Électricité de France) data-based grid-load-following (EDF-GLF) loading cycles. 4) System level thermal-mechanical stress analysis was performed for identifying damage-prone hotspots and for future extension of the model for cyclic state prediction. From the system-level model simulation under DB loading cycle it is found that HL and the SL nozzle that connect to the HL can experience significant stress and strain and could be one of the weakest links in the overall reactor coolant system (RCS). 5) An AI/ML based DT model was developed for multi-time-series temperature prediction at any inside/outside thickness locations of PWR pressure boundary components. This is by using Recurrent-neural-network (RNN) and keras machine learning libraries. The RNN model was validated against two laboratory test-based data sets with one obtained through ANL’s in-air fatigue test system and other through PWR-water test loop. The experimentally validated DT model further validated against FE model results to predict thermal scarification related spatialtemporal temperatures at random locations of a component. The well validated DT model was then used for demonstrating spatial-temporal temperature prediction under 100+ years of reactor operation subjected to combined DB, EDF-GLF and randomized grid-load-following (RANDOMGLF) loading Cycles. The expert-elicitation DT model framework was developed assuming field/input/process measurements can be available from a few existing plant sensors and can readily be used by the NPP operators. The above temperature prediction model will feed to the next-step stress analysis model based on which the life of a component can be predicted in realtime, which is one of our future works.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Initial Temperature Testing of Advanced Manufactured Melt Wire Package

As a part of the In-Pile Instrumentation Program, The Idaho National Laboratory (INL) has recently established in-house capabilities to fabricate and test new advanced manufactured sensors for measuring the peak irradiation temperature inside a nuclear test reactor. Although nuclear test reactors can use standard methods of real-time temperature monitoring, such as thermocouples, the complexity of feedthroughs and attachment complications to collect real-time measurements greatly increases the cost of the experiment. Passive monitoring techniques may be utilized that exploit the melting point of well characterized material (standard melt wires), however, the limited space available for instrumentation during experiments is also a challenge. To accommodate the challenge, INL has expanded its temperature detection instrumentation capabilities paired with the advancement of in-house advanced manufacturing options to include printed melt wires for peak irradiation temperature measurement. The advanced manufactured melt wire package can determine peak temperatures in experiments that can fit the challenging space available during irradiation. Recent results and knowledge from this ongoing work have made it possible to develop unique temperature sensors that can accomplish user specific temperature ranges inside the harsh environments experienced during radiation testing. This report summarizes the initial temperature testing using fabricated melt wires with two different melting temperatures, silver (melting temperature of ~960 °C) and solder (melting temperature of ~160 °C), that were initially tested for their relative melting points using non-standard method of furnace and hot plate testing under normal air conditions. Future work will include more controlled way of testing printed melt wires under inert gas with multiple temperature measurements followed by comparison of standard melt wire package performance for baseline characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

USHPRR MP-1 Irradiation Test: Assessment of Edge Pitting and Bond Line Corrosion in Vendor Produced Fuel Plates

This report summarizes an effort to identify the source of anomalous localized edge pitting and bond line corrosive attack of experimental mini fuel plates manufactured at the commercial fuel vendor BWXT and tested in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) as part of the Miniplate 1 (MP-1) irradiation test. The MP-1 test was conducted by the US High Performance Research Reactor Project (USHPRR) and overseen by the Fuel Qualification Pillar (FQ). The test involved evaluation of a mix of 62 “vendor” fuel plates fabricated at BWXT and 12 “laboratory” fuel plates fabricated at Idaho National Laboratory using commercial-scale and labscale fabrication processes respectively. The MP-1 test was the first in a series of tests to generate data to support qualification of a new plate-type low-enriched uranium (LEU) U-10Mo monolithic fuel system. The major objective of the MP-1 experiment was to test, for the first time, miniplates fabricated by a commercial fuel vendor over the range of irradiation conditions relevant to conversion of NRC regulated High Performance Research Reactors (HPRRs) from high-enriched uranium to LEU. The focus of the efforts described in this report are the vendor fuel plates to inform changes in the fabrication process prior to fabrication of the next miniplate experiment MP2.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗