Engineering Papers⌕ Search

DOE OSTI · 1571247

REBUS-PC v1.5 Verification Test Summary

Abstract

Motivated in part by its usage for analysis of the University of Missouri Research Reactor (MURR), the verification of the REBUS-PC software for θ-R-Z geometries is discussed and displayed in this manuscript. Of particular importance is to show that the eigenvalue, flux, power, and burnup outputs of the software given a user problem is correct. REBUS-PC contains many features and MURR only makes use of some of those aspects. As an example, the use of region specific cross section sets, interpolation of the cross section data with respect to burnup, and automatic movement of control rods during the fuel cycle is discussed and displayed. To demonstrate the accuracy, 22 verification tests based upon 7 physical geometries are discussed. Geometry descriptions are provided in Section 2 and the REBUS-PC results for each verification test are discussed in Section 3. These verification tests consist of both analytic problems with known solutions and a more complicated input consistent with usage of REBUS-PC on the MURR reactor itself called STRZ. In this verification test summary report, the REBUS-PC software is repeatedly demonstrated to reproduce, or closely match, the eigenvalue, flux, and power distributions from analytic test problem solutions, demonstrating that the implemented finite difference approximation in θ-R-Z is working as intended. Several additional REBUS-PC features are tested, such as control rod movement by detailed comparisons of the results against reference solutions obtained using an auxiliary implemented MatLab program. As expected, the REBUS-PC software produces results that are 100% consistent with the stated capabilities and thus the verification exercise is completed. These verification tests should be executed with each re-compilation of the REBUS-PC source and after any source code changes. All output results from any such new work should be rigorously compared against the stored output of the 22 verification tests cited in this report that forms the basis of the verification process.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Deng, P., Lin, C. S., Yang, W. S., Smith, M. A.. 2019-09-01. REBUS-PC v1.5 Verification Test Summary. https://doi.org/10.2172/1571247

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

TANTE: Time-adaptive operator learning via neural Taylor expansion

Operator learning for time-dependent partial differential equations (PDEs) has seen rapid progress in recent years, enabling efficient approximation of complex spatiotemporal dynamics. However, most existing methods rely on fixed time step sizes during rollout, which limits their ability to adapt to varying temporal complexity and often leads to error accumulation. In this work, we propose the Time-Adaptive Transformer with Neural Taylor Expansion (TANTE), a novel operator-learning framework that produces continuous-time predictions with adaptive step sizes. TANTE predicts future states by performing a Taylor expansion at the current state, where neural networks learn both the higher-order temporal derivatives and the local radius of convergence. This allows the model to dynamically adjust its rollout based on the local behavior of the solution, thereby reducing cumulative error and improving computational efficiency. We demonstrate the effectiveness of TANTE across a wide range of PDE benchmarks, achieving superior accuracy and adaptability compared to fixed-step baselines, delivering accuracy gains of 60-80 % and speed-ups of 30-40 % at inference time.

97 MATHEMATICS AND COMPUTING↗

Structured illumination for surface-resolved grazing-incidence X-ray scattering

Grazing-incidence (GI) scattering techniques are widely used to characterize thin films, offering high surface sensitivity and insight into morphology and structure. However, these approaches typically provide statistical averaged information due to elongated footprint or limited spatial resolution due to beam size. Here we introduce a method that combines structured illumination with GI X-ray scattering and leverages our computational imaging approach to resolve local structural details. We demonstrate that our method captures local features of an organic semiconductor thin film without the need for sample rotation as in tomography. The method expands GI techniques from statistical averaging to high-resolution imaging, thereby providing the capability for detailed analysis of local material properties, such as domain shape, orientation and polymorphism, which are critical for advancing material design towards more efficient and tailored materials.

97 MATHEMATICS AND COMPUTING↗