Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,477 records · Page 82

Experimental Investigation of Buoyant Flow in Realistic Bedforms With Heterogeneous Wettability

Submeter-scale geologic heterogeneity greatly affects CO 2 plume migration and retention. In this work, we present meter-scale laboratory experiments that can capture the impact of realistic submeter-scale geologic heterogeneity on multiphase flow and trapping. We produce realistic sedimentary formations consisting of ripple deposits with varying grain size contrast and wettability in a meter-scale slab chamber. Then, we conduct multiphase flow experiments with analog fluids through these structures and measure the saturation patterns, capillary heterogeneity trapping (CHT), and overall trapping performance. When we alter the ripple bedform architecture, variations in trapped saturation and CHT (10–20%) increment are exhibited. Similar growth in trapping performance is also observed when grain size contrast increases. Finally, wettability changes (water- to oil-wet) can increase nonwetting saturation and CHT up to 5% and 10–20%, respectively. These results emphasize the importance of correctly characterizing the impact of small-scale heterogeneities and wettability changes. We believe this is the first time that multiphase flow experiments were conducted in meter-scale domains with realistic ripple bedforms and heterogeneous wettability to investigate plume migration and trapping.

58 GEOSCIENCES↗

Dendrite Growth Morphology Modeling in Liquid and Solid Electrolytes

The main goal of this project is to develop a multi-scale modeling approach that connects micron-scale phase-field models and atomic-scale density functional theory (DFT)-based simulations via parameter- and relationship-passing in order to predict Li-metal dendrite morphology evolution, in both liquid and solid electrolytes. The key hypothesis of the DFT-informed phase-field multiscale modeling approach is that it can capture the electrochemical-mechanical driving forces and incorporate the roles of nano-meter-thin solid electrolyte interphase (SEI) in liquid electrolytes as well as of the microstructures of micro-meter-thick solid electrolytes (SEs) for all-solid-state batteries. In this project, we have formulated and implemented phase-field models to incorporate the electrochemical driving forces in liquid electrolytes and then incorporate mechanical driving forces to simulate dendrite growth in solid electrolytes with resolved microstructures. We have implemented two treatments for the SEI: an explicit model to include the microstructure of the SE or SEI in the phase field model and an implicit model to simulate the impact of nano-meter thick SEI in liquid electrolytes by varying the electrode/electrolyte interfacial properties. The key interfacial properties, including the electronic and ionic transport properties, the charge transfer reaction kinetics, and mechanical properties, were computed by DFT-based calculations. At the DFT-based model, one key advancement is to directly predict the charge transfer reaction kinetics at a complex Li/SEI/electrolyte interface by linking DFT with density functional tight binding (DFTB) calculations. As the main accomplishments, we have demonstrated two successful predictions in both solid electrolyte and liquid electrolyte based on this multiscale approach. The predicted intergranular Li dendrite growth in LLZO revealed the importance of trapped electrons at internal interfaces in the microstructure of LLZO. The predicted electroplating morphology of mossy Li and faceted Mg agreed well with experiments. The insights provided by the multiscale model and the model enabled electrolyte and SEI design will accelerate the development of Li-metal electrode for high energy density batteries, that meet DOE’s target on cell density (>350 Wh/kg) and cost below $100/kWhuse for EV applications.

25 ENERGY STORAGE↗

Agent-Based Coordination Scheme for PV Integration (ABC4PV)

Renewables and especially photovoltaics (PV) have benefitted significantly from a host of incentives and policies targeted toward enhanced integration and adoption of specific energy technologies. However, with the push to move forward into a subsidy-free market framework, behind-the-meter residential PV applications have generally struggled to retain their value (unlike utility scale and commercial projects) [1]. This project focused on developing control-theoretic solutions aimed at improving the integration and interaction of behind-the-meter residential PV with other distribution system assets (controllable and non-controllable) to enhance the integrated value of residential PV. To this end, a suite of decentralized control methodologies have been developed to enable effective coordination and control of behind-the-meter residential load customers’ PV, battery storage systems (BSS), controllable loads and other similar assets within a distribution feeder. This interaction aims at procuring energy savings and, thus, energy bill savings. The main source of savings is drawn from reducing the effect of demand charge pricing and is realized at the feeder level, assuming community level interaction and management among the aforementioned assets. Optimal control of the assets is implemented with a distributed optimization methodology, leveraging consensus-based algorithms. The results gathered from the optimal control simulations demonstrates that the savings can be duly achieved and the algorithm decision times (to dynamically control asset set points, for example) are fast. As for the overall efficiency of PV+BSS systems, to procure energy savings from curtailment of the demand charge pricing effects, the optimal control is set up so as to minimize the variance of the load for all customers, throughout a feeder and throughout time in a rolling horizon scheduling with model predictive control. The control takes into account inter-temporal electrochemical storage (battery) degradation costs: specifically, we have developed a long-term lifetime model for the BSS that weighs in the effect of the degradation factor in the dispatch formulations, thus, a considerable operating cost that affects energy decision making. The levelized cost of energy (LCOE – redefined for the purpose of quantifying asset integration effectiveness through the customers’ energy cost) is shown to be below the threshold set for the combined PV+BSS topology of $ 0.14/kWh for multiple cases of PV penetration all the way up to 50%, provided that a policy of shared ownership of and savings is in place. Further, the LCOE calculated for the case before the deployment PV+BSS systems is also achievable, i.e. the deployment of PV+BSS, if planned and scheduled optimally. will have no effect on customers’ energy costs. From the control methodology viewpoint, the developed consensus-based algorithms are shown to converge for a wide range of problem cases (spanning normal operating scenarios and contingencies), guaranteeing dispatch solutions under forecasting errors, communication break-downs and cyber-security attacks. The proposed control solutions are scalable and real-time implementable, with dispatch computations and device set-point updates converging in less than 2s in most practical instances of the above events.

14 SOLAR ENERGY↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Studying Rate of Fire Spread Using Landscape Statistics and FIRETEC

Wildfires are multi-system and multi-scale processes that are influenced by the land and atmosphere. Here, we study the influence of land, in terms of topography and vegetation, on uphill and downhill fire spread using data of the state of California as a testbed. The California landscape is first quantified by reclassifying its dominant vegetation types into grass, trees, and shrubs. Next, statistics of slope, vegetation height, and live fuel moisture percentage for each dominant vegetation type are gathered to create ensembles of idealized computational fluid dynamics (CFD) model simulations representative of the landscape. Rate of spread values for each CFD simulation are recorded to observe the differences in perturbing slope and fuel moisture for each vegetation type. We have found that all vegetation types prefer slopes of less than 30 degrees. Trees in the California data are 10 to 40 meters high, whereas shrub heights are less than 3 meters and grass heights are less than 1 meter. The live fuel moisture percentage of both trees and shrubs fluctuates around approximately 100% over one year (2019-2020). Using these parameters as inputs into the CFD model, fire spread rate is found to be fastest in the grass ensemble (maximum 12 m s -1 ), followed by shrubs (maximum 10 m s -1 ) and lastly by trees (maximum 7 m s -1 ). Increasing slope increases the spread rate of the uphill fire but the downhill spread decreases for slopes greater than 15 degrees. Increasing fuel moisture decreases the spread rate both up and down the hill. This study highlights the impacts that topography and vegetation have on fire spread.

54 ENVIRONMENTAL SCIENCES↗

IACMI Project 4.2: Thermoplastic Composite Development for Wind Turbine Blades

(Section 5.1) Composites made from Arkema’s Elium® thermoplastic resin and Johns Manville fiberglass were researched during this project for applications in wind blade manufacturing. A techno-economic model was developed to model this wind blade manufacturing process using these materials in place of traditional composites made with thermoset resin. This model was based on manufacturing a 61.5-meter wind blade, which showed a 4.7% reduction in wind blade cost as compared traditional thermoset materials. These cost savings were not from the thermoplastic material costing less than traditional thermoset materials, but rather from decreased capital costs, faster cycle times and reduced energy requirements and labor costs. (Section 5.2) An infusion and curing model was developed for thermoplastic composite wind blades using PAM-RTM. The primary goal was to demonstrate the infusion simulation for the Elium® resin system on a 13-meter wind blade. Additionally, the exotherm temperature was predicted and compared to measurements, which showed model results within 10% of actual measurements. (Section 5.3) Composite laminate panels and composite sandwich panels with a balsa core were produced; specimens were cut and characterized. Similar composite specimens were made with Elium® thermoplastic resin and Hexion thermoset epoxy (RIMR135/RIMH1366) to enable comparisons between these resin systems. The static test methods included: tensile, compression, in-plane shear, interlaminar shear, flexural, sandwich core shear flexure, and single cantilever beam tests for sandwich beams. Fatigue testing at room temperature was completed to composite laminate panels at a stress ratio of R=0.1 and R=10. In addition, fatigue testing to laminate panels was completed at -30°C, and at room temperature after conditioning specimens at 70°C and 90% relative humidity. Overall, mechanical test results from Elium® composites are similar to epoxy composites. (Section 5.4) Elium composite panels were produced with intentional defects such as voids and nonwetting of fibers to begin to understand performance sensitivity to defects. A thermal digital image correlation (TDIC) method provides high spatial resolution strain field at elevated temperatures and can be used to identify defective regions within composite panels. Flexural modulus differences of 21% were seen between defect and non-defect panels. Other Elium® composite panels were forced to be defective by boiling the resin after infusion, which created voids throughout the composite laminate. X-ray computed tomography scanning was used to view the internal structure of the defect panels. Defect panels had a significant reduction in fatigue life as compared to baseline panels produced without intentional defects. (Section 5.5) Lap shear specimens were fabricated to compare the lap shear strength of an off-the-shelf adhesive (Plexus MA590) and two new adhesives developed by Arkema (Bostik SAF30 90 and Bostik SAF30 120). ISO standard 4587:2003 was used to standardize the testing method and sample fabrication. Lap shear specimens were made at 1mm, 3mm, and 10mm thicknesses. The Bostik adhesive lap shear test results were similar to Plexus for all thicknesses. (Section 5.6) Fiber-reinforced polymer (FRP) composites are typically used in high-performance applications (e.g., aerospace), and their expansion into high-volume industries (e.g. consumer automotive and wind turbine blade manufacturer or similar) is hindered by their cost and a lack of efficient manufacturing techniques. Monitoring the curing process of these composites during manufacturing can improve the efficiency of the process, and therefore reduce the manufacturing cost. Cure monitoring techniques were developed that use probabilistic estimation methods and surface temperature measurements made using infrared cameras. These techniques enable real-time monitoring of the infusion process to locate manufacturing flaws, and they can, potentially, estimate residual stresses in the part. Their commercialization will help facilitate expansion of FRP composites in high-volume industries. (Section 5.7) A 13-meter composite wind blade was produced with Elium® resin and Johns Manville fiberglass; this blade was made with VARTM processing similar to how megawatt-scale wind blades are currently manufactured, but no post-mold heating was used for this thermoplastic composite blade. The wind blade underwent full-scale validation for static loading (4-different load orientations) and flapwise fatigue loading to simulate 20-years of operational loads. The thermoplastic composite wind blade withstood the loading without any noted issues and performed similar to results from a previous full-scale validation to an equivalent epoxy composite wind blade produced with the same blade molds. (Section 5.8) A study was conducted to determine the feasibility of recycling composite wind turbine blade components fabricated with glass fiber reinforced Elium® thermoplastic resin. Dissolution, which is a process unique to thermoplastic matrices, allows recovery of both the polymer matrix and full-length glass fibers, while maintaining their stiffness and strength throughout the recovery process. The economics of recycling is favorable if 50% of the glass fiber is recovered and resold for a process of $\$$ 0.28/kg, and 90% of the resin is recovered and resold at a price of $\$$ 2.50/kg.(Section 10) Recommendations are outlined for commercializing thermoplastic resin for composite wind blade production, in addition to recommended areas for future research.

17 WIND ENERGY↗

Tracking the PACE of household energy usage: Energy usage impacts of projects financed through Property Assessed Clean Energy programs in California

This report examines the household-level energy impacts of residential property assessed clean energy (R-PACE) projects using normalized metered energy consumption methods. Our analysis covers projects that occurred through an R-PACE program between 2009 and 2017 and includes more than 25,000 electricity meters and 15,000 gas meters. We employ a comparison group, drawn from other R-PACE households with similar locational and usage characteristics whose projects were implemented at different times, to control for some non-project and non-weather factors that may impact energy use. We find that projects consisting of energy efficiency technologies save, on average, about 3% of household electricity usage and 3.5% of household gas usage. R-PACE financing, however, can be used to install central heating or air conditioning equipment for the first time. These projects would be expected to increase energy consumption. Since our data do not directly indicate which projects are new installations, we develop a simple algorithm for identifying them. Removing these inferred installation projects yields average savings of about 5% for electricity and 6% for gas for those households that remain in the sample. Given the mild California climate and the results of another study of similar California projects using similar methods, these results are in line with expectations. Solar PV projects yield large reductions in grid electricity use, averaging 69% of household consumption. We estimate that, collectively, all R-PACE projects installed in California through 2019 would generate annual reductions in grid-tied electricity consumption of 506 GWh (mostly due to solar PV) and gas consumption reductions of 2 million therms in a normal weather year. These impacts are equivalent to the electricity consumption of about 74,000 California households (including both efficiency and PV generation) and the gas consumption of about 4700 California households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oak Ridge National Laboratory Pilot Demonstration of an Attestation and Anomaly Detection Framework using Distributed Ledger Technology for Power Grid Infrastructure

This report summarizes the design and pilot demonstration of a framework called Grid Guard that was created to provide increased data and device trustworthiness to electric grid devices by leveraging distributed ledger technology (DLT), specifically blockchain. Grid Guard contains a combination of core cryptographic methods such as the secure hash algorithm (SHA), and asymmetric cryptography, private permissioned blockchain, baselining configuration data, consensus algorithm (Raft) and the Hyperledger Fabric (HLF) framework. The system implements a low energy, fast, and robust enhancement to system trustworthiness within and across electric grid systems such as substations, control centers and metering infrastructures. Blockchain is a distributed database structured that provides a practically unalterable (immutable) timeline of stored transactions. By relying on hashing and the Raft consensus algorithm, if an entity tries to illegitimately alter a record at one instance of the database the other ledger nodes are not altered. They work to cross-reference each other and easily locate any incorrectly added data and remove it. The bulk raw data is stored in an off-chain storage (outside of the blockchain ledger) and a hash of this baseline data is stored in the Blockchain ledger via hashing windows of time-series and configuration data, after aggregation and filtering. The bulk off-chain data repository is then considered to be trust-anchored using the hashes stored in the blockchain. To secure the electric grid testbed devices and data, device configuration baselines were compared to those baselines that had been previously stored in the ledger. Statistical baselines for device configurations, network communication patterns, and high-speed sensor data are calculated and then stored off-chain and hashes stored in the ledger. Measurements such as three-phase voltage and current, frequency, breaker status, protection scheme settings, network configuration settings (and other device configuration artifacts) and network traffic features (packet interarrival times) are compared every minute or other selected time windows. During phase 1 of the Grid Guard DLT project different DLT technologies were studies, and an assessment was performed on DLT technology vulnerabilities, uses, and key characteristics. DLT consensus protocols were studies (e.g., RAFT, named after Reliable, Replicated, Redundant, And Fault-Tolerant). Also, cryptography, public, private and permissioned or permissionless systems were assessed. Grid Guard implements a permissioned private DLT. Consensus algorithm selection and choice of DLT implementation depended heavily on the use-case. For this use-case, parameters were selected to measure performance and existing tools for assessment. Benchmarking was performed theoretically and practically. During phase 2 hashed transactions/blocks were inserted into the ledger every second. During phase 2 of the Grid Guard DLT project, a prototype framework was developed and demonstrated for attestation of critical substation devices and data using precision timing systems that use PTP and IRIG-B protocols) on a testbed of operational devices that emulated a distribution substation, control center, and power metering infrastructure using real Operational Technology (OT). The testbed includes OT devices such as protective relays, human machine interfaces (HMI), and power meters. To determine when to collect and compare system and network baselines, an initial examination of an anomaly detection capability to identify malicious manipulation of data streams was conducted. The resulting anomaly detection was demonstrated in a set of experiments and leveraged to trigger device artifact attestation checks. Attestation checks occur against device configuration baselines when compared with the immutable blockchain-stored baselines, which provided a cryptographically supported means by which to store baselines. The electrical substation-grid testbed was created to test the Grid Guard framework. The testbed emulates the operations of a portion of a power grid and SCADA systems as closely as possible. The testbed integrates real protocols, mainly IEC 61850 standard protocols, such as the Sampled Value (SV) and the GOOSE protocols. The testbed also supports DNP3 and other layer 2 and layer 3 protocols such as Telnet, SSH, SFTP/FTP and other proprietary protocols needed to connect to industrial control system equipment. The testbed emulates real power conditions using the OpalRT hardware-in-the-loop (HIL) device which can create fault situations that cannot be easily tested on real systems. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that electrical utilities commonly use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Housing Energy Connection Project (Final Technical Report)

This project expanded existing medium-voltage distribution to 33 households, a daycare, a mechanical shop, irrigation pumps, and a sewer lift station, all of which previously received electric service from the local electric utility. As part of the project, automatic meter reading (AMR) and advanced metering infrastructure (AMI) was installed to allow the Tribe to set up its own electric metering like a utility. The primary objective of this project was to expand the Tribe-owned electrical distribution to provide highly reliable electrical service to these existing loads. The objective was successfully met after project completion. The project reduced high costs for electric energy previously supplied by the utility, by supplanting utility-supplied electric power with Tribe-generated electric power. The project gave the Tribe greater independence from traditional power sources and provided jobs for the community.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Direct Measurement of Light Scattering and Quantum State Preservation from Non-Specular Materials [Slides]

Conclusions from Bidirectional Reflectance Distribution Function (BRDF) Measurements: Mirrors are specular and have consistent reflectance over a range of angles. The measured power of the reflected light was consistent for all power meter positions; Kapton had a similar specular response as the mirror (FWHM), but displayed varying power levels for the different power meter positions (much like the Anodized AI and the Solar Cells); The Solar Cells had very high loss consistent with a material that is supposed to absorb light, but still exhibited specular behavior for FWHM; The Anodized AI had the most diffuse (highest FWHM) reflectance and low BRDF amplitude; Also tried to measure the BRDF Aeroglaze (a common satellite coating) but the power meter was not sensitive enough. To the eye, this material seemed very absorbent and any reflection would be very diffuse.

36 MATERIALS SCIENCE↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

Non-contact based measurement of thin film coatings using eddy current measurements

When a time varying magnetic field attempts to penetrate a conductive surface, the surface will respond to that time varying field by the generation of circular currents around the flux lines. This effect is described by Faraday’s law of induction. An eddy current based measurement system attempts to discern the power loss incurred by these circulating currents within the conductive surface. The measurement system described here uses an Agilent E 4980A LCR meter to quantify the reaction of the film to the high frequency magnetic field lines which are forced into the film. The measurement metric is the meter’s interpretation of the power dissipation caused by the measured film. The meter is setup to use the Ls/Rs inductor model, and is run at 1 Mhz to bring the losses within the film as high as possible for sensitivity.

43 PARTICLE ACCELERATORS↗

Automated Model for Improved Mapping of Country-Scale High-Resolution Coastal Bathymetry

Accurate and up-to-date maps of coastal bathymetry are critical for a variety of sectors from vessel navigation to port construction and are increasingly vital to inform coastal infrastructure management amid accelerating sea-level rise and more frequent and severe storm-surge events. The primary challenges to accurate and efficient bathymetric mapping from optical remote sensing are: accurately modeling light attenuation in both the atmosphere and water column; and inefficient data processing pipelines for highresolution satellite imagery. To address the effects of light attenuation within the water-column we have developed a novel physics-based bathymetry model that accounts for variations in water-column inherent optical properties on a pixel-by-pixel basis in optically-shallow aquatic environments, which represents a major advancement. For applications to satellite imagery, we have developed a software package that automatically applies the robust 6S atmospheric correction algorithm, estimates the bottom depth from the physics-based bathymetry model, which corrects for attenuation by suspended particulate matter and colored dissolved organic matter in the water column on a pixel-by-pixel basis, and leverages highperformance computing for rapid application to region-scale (e.g., CONUS) 2-meter resolution imagery datasets. Our approach is tailored to sensors that collect data at two-meter resolution with high return times for frequent updates. We mapped 591 WorldView satellite images for Florida, North Carolina, and Alaska and validated the maps against LiDAR-derived bathymetry data. Results show median RMSE of 1.75, 1.59, and 2.67 meters, respectively. By combining the strengths of Oak Ridge National Laboratory in high-performance computing and remote-sensing science with the water-column modeling expertise of Scripps Institution of Oceanography we advance the state of bathymetric mapping capability.

54 ENVIRONMENTAL SCIENCES↗

Electrical Resistivity Tomography Monitoring of In Situ Soil Flushing at the Hanford 100-K East Area: 100KE Soil Flushing Monitoring

Former operations in the 100-KE Area at the Hanford Site resulted in vadose zone hexavalent chromium that provides a source of groundwater contamination. Previous efforts to remediate vadose zone chromium involved excavation and offsite treatment of contaminated soils. Although much of the chromium was removed, contamination still exists in native soil between the water table and the bottom of the pit, which has since been backfilled. In-situ soil flushing was tested at the 100-KE Area to accelerate the removal of the remaining hexavalent chromium in the vadose zone. Soil flushing works by applying clean flush water at the surface, which mobilizes and transports chromium as it migrates downward to the water table. Once the chromium reaches the water table, it is hydraulically contained, extracted, and treated through pump and treat operations. The efficacy of soil flushing is directly related to the volume of clean water that infiltrates through contaminated soils. Therefore, performance monitoring requires and understanding of flush water migration through the vadose zone. It is challenging to comprehensively assess soil flushing performance via borehole access due to the limited volume of investigation afforded by a given wellbore. As an alternative, 3D time-lapse electrical resistivity tomography (ERT) was tested as a method of monitoring the distribution of flush water over time within the vadose zone. ERT is a method of imaging the bulk electrical conductivity of the subsurface, which is highly dependent on water saturation levels in unconsolidated and unsaturated sediments. Thus, the timing and location of changes in bulk conductivity caused by soil flushing can be used to infer flush water migration pathways. In this report we present results of 3D time-lapse ERT imaging during two separate soil flushing campaigns conducted during the spring and summer months of 2022 and 2023. Results show generally that: 1) Pit backfill materials appear to nominally have larger permeability than native soils. Consequently, the boundary between pit backfill and native soil had a significant impact on flush water migration, causing some flush water to migrate along the pit boundary to the bottom of the pit. 2) Non-uniform flows, likely caused by variations in hydrogeologic properties, developed in the pit backfill materials, resulting in uneven flush water distribution on the southern margin of the soil flushing zone. 3) Redistribution of water at the interface between backfill materials and Hanford formation materials likely facilitated elevated and uniform distribution of flush water within native soils beneath the deeper parts of the pit boundary beneath the center of the flush zone, which presumably overlie soils with elevated chromium contamination. These areas appear to have been infiltrated by higher volumes of flush water than the northern and southern margins of the flush zone. 4) In comparison to 2022, high flush water application rates significantly improved flush water distribution throughout the target flushing zone. 5) Imaging resolution was limited to a depth of approximate 20 meters below the land surface, due primarily to limitations on the lateral extent of the surface ERT array. The ~10 m region of the vadose zone between approximately 130 meters elevation and the water table at approximately 120 meters elevation was unresolved.

100 Area↗

One Year In: Tracking the Impacts of NEM 3.0 on California’s Residential Solar Market

On December 15, 2022, the California Public Utilities Commission passed an overhaul of the net metering program for the state’s investor-owned utilities. The changes replaced the long-standing net energy metering (NEM) tariffs with a net billing tariff (NBT) structure—colloquially known as “NEM 3.0”—which significantly reduces the compensation for behind-the-meter solar photovoltaic (PV) systems. The NEM tariffs remained open for new interconnection applications until April 15, 2023, but after that date, all new interconnection applications were submitted under NBT. Now, one year later, we have an opportunity to evaluate how the California solar market has evolved under this new compensation regime. As a precursor to its annual Tracking the Sun report, Berkeley Lab has released a short technical brief describing key trends in the California residential solar market since the roll-out of the new NBT structure. The purpose of this analysis is to provide empirical insights into how the market has evolved over the past year, confirming some expectations while also revealing several striking surprises.

14 SOLAR ENERGY↗

Microreactor Incident-Free Transportation Radiation Dose Assessment

This report, prepared by Pacific Northwest National Laboratory (PNNL) for the U.S. Nuclear Regulatory Commission, provides an estimate of the radiation dose related to the transportation of microreactors following the regulatory limits established in Title 10 of the Code of Federal Regulations (10 CFR) 71.47(b). The transportation of irradiated microreactors poses unique challenges. Microreactors may be challenged to meet the current 10 mrem/hr limit at 2 meters from the vehicle in 10 CFR 71.47(b). The need to modify packaging to be within practical weight and size limits for shipping may limit the amount of shielding that can be applied for a microreactor transportation package design. Operational strategies that would necessitate moving a reactor within a short time after its operating life may result in higher radiation dose rates associated with lower cooling times. This study estimates the radiation dose to maximally exposed individuals (MEIs) under the current regulatory radiation level limit of 10 mrem/hr at 2 meters from the vehicle as well as alternative limits of 10, 50, 100, and 200 mrem/hr at 2 meters from the vehicle. This analysis expands on prior incident free transportation radiation dose assessments conducted for spent nuclear fuel (SNF) and radioactive waste transportation. The key factors analyzed include the microreactor fuel type and burnup, shipment cooling periods, shielding designs integrated into transport packaging, and exposure scenarios for MEIs for highway and rail transport. This report considers additional distances that may be associated with compensatory measures to ensure safe transport conditions under varying radiation dose limits, including enhanced routing measures, escort protocols, vehicle inspections, and operational restrictions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

EVs-at-RISC: A Secure and Resilient Interoperable SCM Control System Architecture for Electric Vehicle’s-at-Scale (Final Technical Report)

The EVs-at-RISC project was a five-year research, development, and demonstration initiative to create foundational tools for utility-scale fleet aggregation and Smart Charge Management (SCM) of Electric Vehicles (EV), Electric Vehicle Charging Infrastructure (EVCI), and related Distributed Energy Resources (DER). Rather than seeking to develop and demonstrate highly perfected SCM algorithms and control strategies, this project instead focused on creating foundational software solutions that enable unprecedented digital interoperability across the communications technologies and vendor platforms used to manage EV , EVCI, and DER, as well as existing energy management infrastructure operated by utilities, grid operators, and aggregators. This project then extends these novel interoperability capabilities to develop and deploy powerful middleware abstractions across grid edge networks and EVCI/DER fleet aggregations incorporating modern software tools and best practices, such as CI/CD, to bring the immense capabilities of infrastructure-as-code and policy-as-code to modern grid edge network environments. This addresses the foremost systemic issues preventing realization of any net operational benefits from scaled deployment of behind-the-meter EV, EVCI, and DER assets in electric power grids and markets today. The results of this approach and project unlock massive potential for new SCM capabilities to be easily prototyped, evaluated, and deployed at-scale within the existing grid edge network infrastructure and EVCI/DER technology ecosystem. The EVs-at-RISC project achieves this by extending Open Field Message Bus (OpenFMB), a conceptual model for digital interoperability and distributed intelligence in traditional front-of-meter utility SCADA networks, validating our hypothesis that OpenFMB could be similarly used to solve systemic digital interoperability issues in behind-the-meter environments and unlock real-world utility-scale SCM capabilities without requiring any new proprietary vendor solutions or significant infrastructure reconfiguration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Storage Impacts in Resilience Hubs and Other Critical Infrastructure: An Assessment Guide for Developers and Practitioners

Battery energy storage systems (BESS) deployed behind the meter at resilience hubs and other critical infrastructure can provide economic and operational value during normal operations—such as lower and more predictable energy costs—as well as resilience and security benefits during power disruptions by maintaining essential services. However, existing evaluation approaches tend to focus narrowly on engineering performance or rely on broad socio-economic frameworks that are not well suited to behind-the-meter storage. As a result, developers, utilities, and funders often lack consistent methods for defining success, quantifying benefits, and comparing outcomes across projects. This report presents a practitioner-oriented impact assessment framework for evaluating behind-the-meter BESS at resilience hubs and critical infrastructure facilities. The framework is organized into five iterative components—developing an action plan, defining project goals, identifying metrics, collecting data and measuring outcomes, and reporting and using results—and includes a structured metric architecture spanning six impact categories. Designed for real-world constraints such as limited staffing and uneven data availability, the framework was developed, applied, and refined through real projects, and is illustrated with case studies across diverse deployment contexts.

Impact Assessment↗