Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Low-pressure clathrate-hydrate formation in amorphous astrophysical ice analogs

In modeling cometary ice, the properties of clathrate hydrates were used to explain anomalous gas release at large radial distances from the Sun, and the retention of particular gas inventories at elevated temperatures. Clathrates may also have been important early in solar system history. However, there has never been a reasonable mechanism proposed for clathrate formation under the low pressures typical of these environments. For the first time, it was shown that clathrate hydrates can be formed by warming and annealing amorphous mixed molecular ices at low pressures. The complex microstructures which occur as a result of clathrate formation from the solid state may provide an explanation for a variety of unexplained phenomena. The vacuum and imaging systems of an Hitachi H-500H Analytical Electron Microscope was modified to study mixed molecular ices at temperatures between 12 and 373 K. The resulting ices are characterized by low-electron dose Transmission Electron Microscopy (TEM) and Selected Area Electron Diffraction (SAED). The implications of these results for the mechanical and gas release properties of comets are discussed. Laboratory IR data from similar ices are presented which suggest the possibility of remotely observing and identifying clathrates in astrophysical objects.

Blake, D. F.↗

Diffusion mechanisms in Ir-coated Re for high-temperature, radiation-cooled rocket thrusters

Materials used for radiation-cooled rocket thrusters must be capable of surviving under extreme conditions of high temperatures and oxidizing environments. Thruster chambers were developed using chemical-vapor-deposited (CVD) Re coated with CVD Ir on the inside surface which is exposed to hot combustion gases. Ir serves as an oxidation barrier protecting the Re which maintains structural integrity at high temperatures. In order to predict and extend the performance limits of these Ir-coated Re thrusters, the diffusion kinetics of CVD materials at temperature are studied. Thruster end ring sections were examined using electron microprobe analysis both before and after exposure to high temperature vacuum environments. The resulting elemental maps for Re, Ir, and Mo in the near-surface region allow identification of diffusion mechanisms operating at these temperatures. Line scans for Ir and Re were fit using a diffusion model to extract relevant diffusion constants. The fastest diffusion process is seen to be grain boundary diffusion with Re diffusing down grain boundaries in the Ir overlayer. The measured dependence of the diffusion rate on temperature will allow prediction of operating lifetimes for these thrusters.

Hamilton, J. C.↗

Current Problems in X-Ray Emission Spectroscopy

Various problems that limit X-ray analysis in the analytical electron microscope are reviewed. Major emphasis is given to the trade-off between minimum mass fraction and spatial resolution. New developments such as high-brightness electron guns, new X-ray spectrometers and clean high-vacuum analysis conditions will lead to major improvements in the accuracy and detectability limits of X-ray emission spectroscopy.

Goldstein, Joseph I.↗

Review of the High Performance Antiproton Trap (HiPAT) Experiment

Many space propulsion concepts exist that use matter-antimatter reactions. Current antiproton production rates are enough to conduct proof-of-principle evaluation of these concepts. One enabling technology for such experiments is portable storage of low energy antiprotons, to transport antiprotons to experimental facilities. To address this need, HiPAT is being developed, with a design goal of containing 10(exp 12) particles for up to 18 days. HiPAT is a Penning-Malmberg trap with a 4 Tesla superconductor, 20kV electrodes, radio frequency (RF) network, and 10(exp -13) Torr vacuum. 'Normal' matter is being used to evaluate the system. An electron beam ionizes background gas in situ, and particle beams are captured dynamically. The experiment examines ion storage lifetimes, RF plasma diagnostics, charge exchange with background gases, and dynamic ion beam capture.

Martin, James J.↗

Scanning Microscopes Using X Rays and Microchannels

Scanning microscopes that would be based on microchannel filters and advanced electronic image sensors and that utilize x-ray illumination have been proposed. Because the finest resolution attainable in a microscope is determined by the wavelength of the illumination, the xray illumination in the proposed microscopes would make it possible, in principle, to achieve resolutions of the order of nanometers about a thousand times as fine as the resolution of a visible-light microscope. Heretofore, it has been necessary to use scanning electron microscopes to obtain such fine resolution. In comparison with scanning electron microscopes, the proposed microscopes would likely be smaller, less massive, and less expensive. Moreover, unlike in scanning electron microscopes, it would not be necessary to place specimens under vacuum. The proposed microscopes are closely related to the ones described in several prior NASA Tech Briefs articles; namely, Miniature Microscope Without Lenses (NPO-20218), NASA Tech Briefs, Vol. 22, No. 8 (August 1998), page 43; and Reflective Variants of Miniature Microscope Without Lenses (NPO-20610), NASA Tech Briefs, Vol. 26, No. 9 (September 2002) page 6a. In all of these microscopes, the basic principle of design and operation is the same: The focusing optics of a conventional visible-light microscope are replaced by a combination of a microchannel filter and a charge-coupled-device (CCD) image detector. A microchannel plate containing parallel, microscopic-cross-section holes much longer than they are wide is placed between a specimen and an image sensor, which is typically the CCD. The microchannel plate must be made of a material that absorbs the illuminating radiation reflected or scattered from the specimen. The microchannels must be positioned and dimensioned so that each one is registered with a pixel on the image sensor. Because most of the radiation incident on the microchannel walls becomes absorbed, the radiation that reaches the image sensor consists predominantly of radiation that was launched along the longitudinal direction of the microchannels. Therefore, most of the radiation arriving at each pixel on the sensor must have traveled along a straight line from a corresponding location on the specimen. Thus, there is a one-to-one mapping from a point on a specimen to a pixel in the image sensor, so that the output of the image sensor contains image information equivalent to that from a microscope.

Wang, Yu↗

Systems and Methods of Laser Texturing of Material Surfaces and Their Applications

The surface of a material is textured and by exposing the surface to pulses from an ultrafast laser. The laser treatment causes pillars to form on the treated surface. These pillars provide for greater light absorption. Texturing and crystallization can be carried out as a single step process. The crystallization of the material provides for higher electric conductivity and changes in optical and electronic properties of the material. The method may be performed in vacuum or a gaseous environment. The gaseous environment may aid in texturing and/or modifying physical and chemical properties of the surfaces. This method may be used on various material surfaces, such as semiconductors, metals and their alloys, ceramics, polymers, glasses, composites, as well as crystalline, nanocrystalline, polycrystalline, microcrystalline, and amorphous phases.

Gupta, Mool C.↗

MISSE-11 Ground Experiment Control

Back during the Apollo missions, when astronauts were being sent to the moon to explore and further scientific knowledge by conducting experiments and collecting samples for scientists back on Earth, they were faced with a surprising problem. It was discovered that the moon’s surface is covered with dust that has electrostatic properties, which would stick to suit and equipment. This hindered the functionality of the astronauts’ space suits, solar panels, optical instruments, among other exposed surfaces due to the jagged geometry of the dust which would damage said equipment. To resolve this issue, the Electrostatics and Surface Physics Laboratory (ESPL) came up with the solution of using an Electrodynamic Dust Shield (EDS)1 that uses electrostatic forces to move particles across a surface. Varieties of this dust shield have been developed for different applications. The purpose of the Materials International Space Station Experiments 11 (MISSE-11) is to experiment a payload that contains the dust mitigation technology to be flown to space for one year and an identical payload will be on earth, under vacuum, in the Electrostatics and Surface Physics Laboratory. The space payload was prepared prior to our arrival and shipped to fly on the International Space Station (ISS). The payload staying on the ground is going to act as a control for the experiment so that we may compare it to the payload that was flown in space. During our time at Kennedy Space Center, we were tasked with building and start testing the ground control unit of the MISSE-11 payload. To complete our task for the ground control unit, we constructed a new vacuum chamber setup and added automated aspects, procured the necessary flight electronics, designed and communicated for the machining of the payload frame, and performed functional and thermal testing on the electronics to the same original operational standards. Some modifications were made where possible, without affecting the performance of the samples, to be efficient with the production of the control unit while keeping important aspects identical. The experiment is now nearly complete, and testing will be starting within the next few weeks.

MISSE↗

Understanding the Chemistry of PAHs in H2O Ice

Polycyclic aromatic hydrocarbons (PAHs) can be incorporated into H O ice grains and mantles found in dense molecular clouds, comets, interplanetary dust particles (IDPs), and many Solar System objects. However, laboratory infrared (IR) spectroscopic studies of PAHs in ices is still a relatively young field. Early research efforts have shown the rich chemistry of PAHs in H O to be dependent on PAH concentration, with the concentration impacting everything from IR band shifts to the photoproducts produced [1-6]. Similarly, research suggests that a potential top-down synthesis route for complex organic molecules or COMs found within solar systems is possible from PAHs in water ice [7]. In order to fully exploit the observations from the James Webb Space Telescope (JWST) more IR studies of PAHs in H O ice under relevant astrophysical conditions and planetary systems are needed. The NASA ICEE (Institute for Carbon Evolution Experiments), formerly the NASA Ames PAH IR Laboratory, has been at the forefront of this field. Starting in 2019, just before the COVID-19 shutdown, the ICEE laboratory underwent a major renovation, gearing it towards in-depth PAHs in H O ice research under relevant solar systems and interstellar conditions. The ICEE facility enables us to study the processing of PAHs in H O ice using UV photons and charged particle (electron) irradiation either singly or in combination under ultra-high vacuum and low temperature (15K). We use in-situ measurements with IR, Raman, and mass spectra by which we monitor the chemistry of PAHs in H O ice before, during and after the irradiation. This presentation will summarize the past work regarding PAHs in ices and provide an update on the latest ICEE research results in this area, outlining a roadmap for future research efforts.

Andrew Mattioda↗

Integrated electron beam tip and sample heating device for a scanning tunneling microscope

An electron beam heating device with the temperature up to 2200 K is provided for heating a sample and a tip for a scanning tunneling microscope (STM). The electron beam heating device includes a base stage for mating respectively with an electron beam sample heating carrier and an electron beam tip heating carrier, both carriers include a filament. The integration of the filament into the transferable electron beam sample heating carrier and electron beam tip heating carrier enables filament exchange without venting the vacuum system. A fixed distance between the sample and the filament enables reproducible sample temperature control and the filament is mounted at a back of the sample, allowing optical access for temperature measurement, and allowing sample preparation processes without changing positions of the sample or the filament. Once the tip is loaded, a fixed relative position between the tip and the filament enables reproducible control of heating. A tip holder includes an electrically isolated post connected to the tip, enabling a separate electrical potential to be applied to the tip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Heat Treatment on Microstructure and Mechanical Property of 316L Stainless Steel Produced by Laser Powder Bed Fusion

The advanced non-light water reactor designs (Gen IV reactors), including molten salt/ very high temperature/ sodium-cooled and lead-cooled fast reactors, typically operate at higher temperatures and more extreme radiation conditions than light water reactors. An intrinsic part of the deployment and progress of Gen IV reactor designs is selecting the most suitable structural material for a specific application. Additive manufacturing (AM), a fairly new process of making physical, three-dimensional objects from a computer design file, is going to completely change the way of design, build and certify nuclear systems. It offers a range of opportunities to produce complex geometries from existing materials, offers new routes for processing of previously difficult to process materials, allows for design of new high-performance materials, and finally facilitates hybridization of dissimilar materials. This emerging technology has successfully produced cars, wind turbine blade molds and even live cells. It could also open up big opportunities for the nuclear industry to quickly deploy technologies at a fraction of the cost. So far, AM techniques have been preliminarily applied in the field of nuclear reactors, including the classical parts such as the pressure vessel of a small reactor with 508-III steel, the bottom nozzle of a fuel assembly with 304L steel, the fuel cladding with zirconium alloy and the integrated impeller of a pump and the multi-channel valve body with 316L steel [6,7]. The AM applications for operating nuclear reactors started in auxiliary plant components and have slowly migrated to metallic reactors and core components, but many of these are not safety critical components. Although many parts used for nuclear reactors have been fabricated by AM techniques, practical applications in engineering are still a long way off due to the uncertainty factors focused on the processing, material properties, analysis methods and application standards, which feeds the safety and life-cycle of the nuclear reactor. Due to rapid, repeated heating and cooling during production, a high dislocation density was present in the AM material. This microstructure feature is unstable at elevated temperature while high temperature is one of the typical operation environments for nuclear reactors. Thus, it is important to understand the thermal effect on the microstructure of AM material. The objectives of this study are to investigate the effect of heat treatment on the microstructure and mechanical properties of 316L stainless steel produced by laser powder bed fusion additive manufacturing, and to determine an appropriate heat treatment practice that will be applied to the lightweight AM lattice-structured material with the same chemistry. The heat treatment study consisted of annealing the samples at a temperature range of 800 to 1200 oC with a 50 oC increment for different times (1-24 hours), followed by vacuum or air cooling. Microstructural characterization was carried out by Scanning Electron Microscope (SEM). Grain size and crystallographic orientation were investigated by Electron Backscatter Diffraction (EBSD). Vickers hardness tests with a 0.5 kg load were employed to determine the hardness of samples after different heat treatments. After heat treatment, the random crystallographic orientation was preserved, and the volume fraction of high-angle grain boundaries (grain boundary misorientation =15 oC) remained the same. The dislocation density decreased with annealing temperature due to recovery. The fine subgrain structures in the as-printed specimen were quite stable up to 1200 oC. Minimal recrystallization was observed up to 1200 oC. Recrystallization initiated only after 8.5 hours at 1200 oC. The SEM images did not show obvious dependence of microstructure on cooling rate. The hardness of the specimens decreased with increasing annealing temperature as a result of the decrease in dislocation density. It is interesting to note that the AM material showed very similar hardness to the wrought material when annealing at similar temperature, although the microstructures are very different. Annealing at 1050 oC for 1 hour followed by air cooling was selected as the heat treatment procedure for the lattice designed lightweight AM 316L material.

36 MATERIALS SCIENCE↗

In-situ X-ray photoelectron spectroscopy studies of water on metals and oxides at ambient conditions

X-ray photoelectron spectroscopy (XPS) is a powerful tool for surface and interface analysis, providing the elemental composition of surfaces and the local chemical environment of adsorbed species. Conventional XPS experiments have been limited to ultrahigh vacuum (UHV) conditions due to a short mean free path of electrons in a gas phase. The recent advances in instrumentation coupled with third-generation synchrotron radiation sources enables in-situ XPS measurements at pressures above 5 Torr. In this review, we describe the basic design of the ambient pressure XPS setup that combines differential pumping with an electrostatic focusing. We present examples of the application of in-situ XPS to studies of water adsorption on the surface of metals and oxides including Cu(110), Cu(111), TiO2(110) under environmental conditions of water vapor pressure. On all these surfaces we observe a general trend where hydroxyl groups form first, followed by molecular water adsorption. The importance of surface OH groups and their hydrogen bonding to water molecules in water adsorption on surfaces is discussed in detail.

36 MATERIALS SCIENCE↗

Multi-messenger dynamic imaging of laser-driven shocks in water using a plasma wakefield accelerator

Understanding dense matter hydrodynamics is critical for predicting plasma behavior in environments relevant to laser-driven inertial confinement fusion. Traditional diagnostic sources face limitations in brightness, spatiotemporal resolution, and in their ability to detect relevant electromagnetic fields. In this work, we present a dual-probe, multi-messenger laser wakefield accelerator platform combining ultrafast X-rays and relativistic electron beams at 1 Hz, to interrogate a free-flowing water target in vacuum, heated by an intense 200 ps laser pulse. This scheme enables high-repetition-rate tracking the evolution of the interaction using both particle types. Betatron X-rays reveal a cylindrically symmetric shock compression morphology assisted by low-density vapor, resembling foam-layer-assisted fusion targets. The synchronized electron beam detects time-evolving electromagnetic fields, uncovering charge separation and ion species differentiation during plasma expansion – phenomena not captured by photons or hydrodynamic simulations. We show that combining both probes provides complementary insights spanning kinetic to hydrodynamic regimes, highlighting the need for hybrid physics models to accurately predict fusion-relevant plasma behavior.

imaging techniques↗

A robust method for handling low density regions in hybrid simulations for collisionless plasmas

A robust method to handle vacuum and near vacuum regions in hybrid simulations for space and astrophysical plasmas is presented. The conventional hybrid simulation model dealing with kinetic ions and a massless charge-neutralizing electron fluid is known to be susceptible to numerical instability due to divergence of the whistler-mode wave dispersion, as well as division-by-density operation in regions of low density. Consequently, a pure vacuum region is not allowed to exist in the simulation domain unless some ad hoc technique is used. To resolve this difficulty, an alternative way to introduce finite electron inertia effect is proposed. Contrary to the conventional method, the proposed one introduces a correction to the electric field rather than the magnetic field. It is shown that the generalized Ohm's law correctly reduces to Laplace's equation in a vacuum which therefore does not involve any numerical problems. In addition, a variable ion-to-electron mass ratio is introduced to reduce the phase velocity of high frequency whistler waves at low density regions so that the stability condition is always satisfied. It is demonstrated that the proposed model is able to handle near vacuum regions generated as a result of nonlinear self-consistent development of the system, as well as pure vacuum regions set up at the initial condition, without losing the advantages of the standard hybrid code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-energy metal ion implantation for reduction of surface resistivity of alumina ceramic

In this work, the possibility to increase the surface conductivity of ceramic insulators through their treatment with accelerated metal ion beams produced by a MevvaV.Ru vacuum arc source is demonstrated. The increase in surface conductivity is made possible due to experimental conditions in which an insulated collector is charged by beam ions to a potential many times lower than the accelerating voltage, and hence, than the average beam ion energy. The observed effect of charge neutralization of the accelerated ion beam is presumably associated with electrons knocked out of the electrodes of the accelerating system of the source and of the walls of the vacuum chamber by the accelerated ions.

36 MATERIALS SCIENCE↗

Studying the Transparency of Graphene for Low-Energy Electrons

The transparency of graphene membranes for electrons with energies in the range from 5 to 50 eV has been studied with a view to using graphene as an electrode stimulating field-induced emission in microand nanoelectronic devices. The behavior of electrons reflected from a membrane was analyzed with allowance for their return under the action of a retarding electric field. Low-energy electrons were represented by photoelectrons emitted from a diamond photocathode under the action of vacuum ultraviolet radiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electronic assembly thermal testing - Dwell/duration/cycling

Testing of electronic assemblies varies throughout industry, NASA, and the military. Differences include test levels, atmospheric versus vacuum testing of assemblies, dwell durations at temperature extremes (especially high temperature), and thermal cycling versus dwell testing. Of particular interest are the different philosophies of thermal cycling versus single-cycle thermal dwell. An examination of the various failure physics for electronic assemblies has been initiated at JPL. The intent is to determine which failure modes are best revealed by thermal cycling testing and which are susceptible to high-temperature dwell physics. Preliminary results of this study are presented, along with discussions of testing goals, flight environments, reliability models, and the differences between industry and JPL design/test approaches.

Gibbel, Mark↗

Side-by-side evaluation of the outgassing rate and ultimate pressure achieved inside tubes made of low-carbon and stainless steel

The hydrogen outgassing rate of a vacuum chamber made of AISI 1020 low-carbon steel was found to be notably smaller than a similar chamber made of AISI 316L stainless steel following heat treatment at 150 °C. When the chambers were baked at 400 °C, the outgassing rate of the 1020 low-carbon steel chamber was approximately 2000 times smaller than that of the 316L stainless-steel chamber. After quantifying hydrogen outgassing rates, vacuum chambers made of 1020 low-carbon steel and 316L stainless steel were heated for a prescribed duration and then pumped with an ion pump and nonevaporable getter pump to reach “ultimate pressure.” The 1020 low-carbon steel chamber reached lower pressures than the 316L stainless-steel chamber. Monte Carlo simulation predictions using the measured hydrogen outgassing rates are in good agreement with the ultimate pressure measurements. Finally, our measurements indicate that low-carbon steel can provide pressures within the extreme high vacuum range (<7.5 × 10 -13 Torr) if care is taken to minimize the surface area contribution from stainless steel.

36 MATERIALS SCIENCE↗