Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “test system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Dataset for SIAM MPI23 Project "Model inversion for complex physical systems using low-dimensional surrogates"

Training and testing data for the SIAM MPI23 workshop "Model inversion for complex physical systems using low-dimensional surrogates". The data consists of ensembles of input and output pairs corresponding to queries of a 2D saturated groundwater flow model. The inputs consist of random vectors which map to discretized model parameter fields via a Kosambi-Karhunen-Loève expansion. Output corresponds to discretized pressure fields.

basis adaptation, conditional Karhunen-Loève expan↗

Performance Evaluation of a Microgrid System with Grid-Forming and Grid-Following Inverters with Diesel Generators: Insights From Hardware Experiments

This paper presents a comprehensive performance evaluation of a microgrid system integrating grid-forming (GFM) inverters, grid-following (GFL) inverters, and a diesel generator, focusing on their interactions and behavior under various dynamic events. The study is conducted using a pure hardware setup comprising two GFM inverters, one GFL inverter, a diesel generator, load banks, a point of common coupling (PCC), and an emulated main grid. The evaluation specifically examines dynamic scenarios, including voltage jumps, phase jumps, rate of change of frequency (ROCOF), synchronization, and islanding operations, which pose critical challenges to system stability. Among all the tests conducted, the overloading and phase jump tests proved to be the most challenging. The capacity of the DC side is crucial for withstanding overloading and grid disturbance tests; otherwise, GFM inverters frequently trip due to DC undervoltage. Throughout all grid disturbance tests, the diesel generator consistently stands out as the most robust and reliable GFM unit in the system. Overall, insights from these hardware experiments shed light on the response characteristics of different generation types during grid disturbances and identify potential stability concerns in such hybrid microgrid systems.

14 SOLAR ENERGY↗

Modeling and Characterization of Surface Discharges in Insulating Material for Spacers: Electrode Shape, Discharge Mode, and Revision of the Creepage Concept

In the design of MV AC and DC spacers, the predominant factors are surface and interface conditions. Design is generally carried out on specifications and standards which are based on long-term experience and lab testing. However, the diffusion of power electronics with a trend to increase electric field, switching frequency, and rise time to achieve higher power density calls for an innovative, global approach to optimized insulation system design. A new methodology, based on field simulation, discharge modeling, and partial discharge inception measurements, called the three-leg approach, can form the basis to optimize insulation design for any type of supply voltage waveform. This paper focuses on the influence of the type of electrode on the inception and phenomenology of surface discharges and, as a consequence, on the interpretation of the results used for application of the three-leg approach. It is demonstrated that a typical electrode system used for insulating material testing can generate both gas and surface discharges at the triple point, when the electrodes have a smooth profile that is used to avoid corona or flashover. Hence, testing partial discharge may not provide a straightforward indication of the surface discharge inception and, thus, be partially misleading for insulation design. Another takeover is that such analysis must benefit from PD testing tools endowed with analytics able to provide automatic identification of the type of defect generating PD, i.e., internal, surface, and corona, since design and remedy actions can be taken, and adequate insulating materials developed, only knowing the type of source generating PD. Hence, testing partial discharge may not provide a straightforward indication of surface discharge inception and, thus, be partially misleading for insulation design. In addition to the importance of the three-leg approach to favor reliable and optimized design of insulation systems, there is a clear need to have a PD testing tool endowed with analytics. It should preferably be able to provide automatic identification of the type of defect generating PD, i.e., internal, surface, and corona.

36 MATERIALS SCIENCE↗

Performance Evaluation of Data-Enhanced Hierarchical Control for Grid Operations

This paper presents a hardware-in-the-loop (HIL) simulation to evaluate the performance of voltage regulation of Data-Enhanced Hierarchical Control (DEHC). This DEHC uses an advanced distribution management system (ADMS) for grid operations to control legacy and grid-edge devices and coordinate with distributed energy management systems (DERMS) to manage high penetrations of photovoltaics (PV) on a utility distribution system. The HIL platform provides realistic laboratory testing, including accurate modeling (legacy devices, grid-edge devices, and PV) of the real-world distribution system from a utility partner, a real controller (ADMS), software controller DERMS, hardware grid-edge devices, and standard communications protocols. The test results demonstrate functionalities of the integrated platform and the performance of voltage regulation of the coordinated control systems. Based on laboratory testing, the utility can set up the same grid-automation system to manage DERs, legacy devices, and grid-edge devices to achieve their system-level control and operation objectives (e.g., voltage regulation), thus de-risking potential issues such as instability for field deployment.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Smart Monitoring and Diagnostic System (SMDS) for Packaged Air Conditioners and Heat Pumps for Small/Medium Commercial Buildings: Preparation for Commercialization: CRADA 478 [Abstract only]

This project will enable Pacific Northwest National Laboratory (PNNL) and industry partner, mCloud Technologies, to work collaboratively to ready the Smart Monitoring and Diagnostic System (SMDS) for commercial deployment and validate its performance under real-world conditions at field sites. This project will specifically focus on 1) implementing the SMDS algorithms in a scalable cloud-based software architecture, 2) designing new, innovative, complimentary commercial services based on the SMDS, 3) enhancing the SMDS energy and cost impact algorithms to reduce uncertainty in estimates, 4) determining the lower limits on SMDS performance degradation detection, 5) validating algorithm performance and default values of adjustable thresholds with existing data from controlled physical testing and from customer packaged air conditioners and heat pumps (commonly referred to as rooftop units or RTUs), 6) field testing to validate the system on multiple customer buildings in diverse environments, and 7) expanding field deployment to a larger set of mCloud’s customer buildings. Project results by validating, enhancing, and quantifying the performance of the SMDS will position mCloud, and potential future licensees, to implement the SMDS in commercial offerings that encourage and enable use of condition-based and predictive maintenance, leading to significant reductions in energy use and greenhouse gas emissions associated with space conditioning by RTUs. Furthermore, these enhancements will increase the value of the SMDS for users and increase the potential market for its use and impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electron Density Measurements Using USPR (Final Scientific/Technical Report)

UC Davis has fabricated an ultrashort pulse reflectometer (USPR) diagnostic instrument for electron density profile measurements on compact, short duration, magnetically-confined fusion-energy concept devices such as spheromaks and FRCs. The USPR system transmits extremely short duration (~few nsec) chirped waveforms that together span 29 to 75 GHz. These chirped waveforms illuminate and reflect from the target plasma, with each frequency component reflecting from a different density layer (higher frequencies probe deeper into the plasma before reflecting). The reflected waveforms are split into roughly 42 different frequencies; time-of-flight (TOF) measurements made at each frequency with high resolution (~25 psec measurement resolution which corresponds to ~5 mm). These TOF data may then be inverted via software to generate electron density profiles with high time resolution (~10 μsec). At the heart of the system is a field programmable gate array (FPGA) based controller which collects and processes all of the USPR data in addition to generating all of the control signals required for maximum flexibility. The FPGA controller has the software flexibility to be easily reconfigured for different plasma devices, and the entire system sufficiently compact to be easily and quickly transported between devices. A high speed impulse generator was transformed into a set of three ultrashort pulse transmitter chirps using a combination of dispersive waveguide, frequency doublers and high-pass filters. A mm-wave controller was fabricated to sequentially switch between the three chirps, directing the chirps one-by-one to three different mm-wave assemblies spanning 29-75 GHz. Each mm-wave assembly consists of a high power active multiplier chain which converts the transmitter chirp to higher frequencies, and a broadband mixer which downconverts the reflected waveform to the 2-18 GHz range of the UPSR receiver. The 16-channel receiver (shared by all 3 mm-wave assemblies) was fabricated employing custom TOF modules capable of operating at a high 1 MHz sampling rate. Laboratory testing of the full system revealed the presence of unwanted harmonics from the multiplication process, with interference observed in the downconverted reflections at selected frequency channels that could not be completely filtered out. Additional interference effects arising from internal reflections within the mm-wave assemblies were minimized using a high-speed switch which served to “gate out” much of these reflections. The USPR diagnostic was transported and installed onto the HIT-SIU plasma device, becoming operational on 11/08/2022. Although designed to span 3 distinct mm-wave bands, the HIT-SIU plasmas at this time were sufficiently low density such that only the lowest of the three bands was likely to have strong plasma reflections. The system was then set to operate on only the lowest band (assembly #1), with data collected every 1 μsec rather than 3 μsec which would have been the case when cycling through all three bands. Connected to HIT-SIU, time-varying plasma reflections were observed on 9 of 16 possible frequency channels. Close examination of the data collected revealed issues previously unobserved in laboratory testing, associated with (a) reflections from the small aperture horns required for operation within the HIT-SIU device, and (b) a dependence of the recorded TOF with the threshold voltage of a given channel. Plans were made to address each of these issues before undertaking any future campaigns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploratory Investigation of Disengagements and Crashes in Autonomous Vehicles Under Mixed Traffic: An Endogenous Switching Regime Framework

Autonomous Vehicles (AVs) have a large potential to improve traffic safety but also pose some critical challenges. While AVs may help reduce crashes caused by human error, they still may experience failures of technologies and sensing, as well as decision-making errors in a mixed traffic environment. A disengagement refers to an AV transitioning control from autonomous systems to the trained test driver. The safety critical nature of disengagements makes it imperative to analyze disengagements and crashes together. In this study, we analyze both crashes and disengagements from real-world AV driving in California to fill the knowledge gap regarding the relationship between disengagements and crashes in a mixed traffic environment. A nested logit model was calibrated using three different outcomes: (1) disengagement with a crash, (2) disengagement with no crash, and (3) no disengagement with a crash. Furthermore, endogenous switching regime models were also calibrated to draw distinctions between the relation of disengagements and crashes while accounting for endogeneity effects. The results show that factors related to AV systems (such as software failures) and other roadway participants increase the propensity of a disengagement without a crash. Furthermore, AVs were observed to disengage less often as the technology matured over time. Marginal effects revealed an 8% decrease. The results thus suggest that disengagements are a part of AVs' safe performance and disengagement alerts may need to be triggered in order to avoid certain failures with current technology.

42 ENGINEERING↗

Performance Evaluation of Hierarchical Controls for Advanced Distribution Management System-Centered Grid Operations: Preprint

This paper presents a hardware-in-the-loop (HIL) platform to evaluate the performance of voltage regulation using an advanced distribution management system (ADMS) for grid operations to control legacy and grid-edge voltage control devices and coordinate with distributed energy management systems (DERMS) to manage high penetrations of photovoltaics (PV) on a utility distribution system. The HIL platform provides realistic laboratory testing, including accurate modeling (legacy devices, grid-edge devices, and PV) of the real-world distribution system from a utility partner, a real controller (ADMS), software controller DERMS, hardware grid-edge devices, and standard communications protocols. The test results show proper functionalities of the integrated platform and the performance of voltage regulation of the coordinated control systems. Based on laboratory testing, the utility can set up the same grid-automation system to manage DERs, legacy devices, and grid-edge devices to achieve their system-level control and operation objectives (e.g., voltage regulation), thus de-risking potential issues (e.g., instability) for field deployment.

ADMS↗

Defending the Homeland: Growing Foreign Challenges to the U.S. Missile Defense Posture

The Office of the Secretary of Defense (OSD) for Policy requested that Lawrence Livermore National Laboratory conduct a Congressionally directed study on homeland missile defense, pursuant to Section 1692 of the fiscal year 2020 National Defense Authorization Act. In accordance with the statutory language, this study considers whether the security benefits obtained by deployment of homeland missile defenses of the United States are undermined or counterbalanced by adverse reactions of potential adversaries, and considers the effectiveness of homeland missile defense efforts of the United States to deter the development of ballistic missiles. Almost a half-century has elapsed since the United States and the Soviet Union signed the Anti-Ballistic Missile (ABM) Treaty, and almost two decades since the former withdrew. Since withdrawing, the United States has sought to develop and deploy a layered missile defense system to defend against regional threats to U.S. and allied interests abroad and to counter limited threats to the U.S. homeland. As such, missile defense supports key national defense policy objectives. Protecting the U.S. homeland, forces abroad, allies, and partners. Deterring attacks against the United States, its allies, and partners. Assuring allies an strengthening U.S. diplomatic activities in peacetime and crisis. We offer five key findings: 1. The primary benefit of the Ground-based Midcourse Defense (GMD) system is the protection it provides the U.S. homeland against a limited but evolving rogue-state missile threat. While this system has never been tested in combat, it appears thus far to have effectively paced North Korea’s development and deployment of intercontinental ballistic missiles (ICBMs). In the absence of such a defensive capability, the United States would likely have been more heavily exposed to North Korean actions, would have operated at a much higher-risk posture, and would have had less negotiating room with which to navigate coercive tactics and crises. Its allies would have been more concerned about U.S. willingness in time of crisis and war to run the risks of protecting them. The GMD system also serves as a hedge against Iranian breakout. 2. Potential adversaries continue to develop long-range ballistic missiles despite deployment of a U.S. homeland missile defense system. This includes both rogue states and major power rivals whose long-range missile programs predated the deployment of U.S. missile defenses. While North Korea has continued its long-range missile developments and achieved an intercontinental capability, Iran has not yet reached this threshold. The broader proliferation of long-range missiles anticipated in the late 1990s has not materialized. 3. While Russia has used the existence of a U.S. homeland missile defense system as a justification for its substantial and continuing weapon modernization program, neither Russian force modernization nor the limited U.S. homeland missile defense system has altered the strategic balance. Russia has long considered U.S. missile defenses—both theater and homeland—as directed against its strategic forces and as a capability that could rapidly advance, thereby eroding Russian confidence in its nuclear deterrent. Russia’s political and military actions appear excessive and negatively impact areas such as arms control, but they do not undermine the primary benefit of the U.S. system cited in Key Finding 1. 4. China’s expansion and diversification of nuclear and missile forces has been influenced by its concerns about U.S. homeland missile defense, but those concerns are only one of many factors in China’s force planning. Although China’s actions to preserve and expand its assured retaliation prospects have not fundamentally altered the strategic balance, its buildup and lack of transparency about its force modernization goals are troubling. Taken together, the aggregate pattern of China’s modernization activities over the past two decades strongly suggests a concerted effort to develop a modern military force commensurate with its intended geopolitical status. Whatever China’s legacy concerns over the survivability of its strategic nuclear forces, its ability to overwhelm the GMD system appears intact today and will be further strengthened in the years ahead as it continues its long-term modernization program. China’s political and military actions negatively affect U.S. security interests but do not undermine the primary benefit of the U.S. system cited in Key Finding 1. 5. The basic finding that benefits have not so far been undermined by adverse reactions is a function of circumstances that are increasingly in flux. The existing GMD-centered system is under increasing pressure from the pace and scope of North Korean missile deployments. The proposed “layered” system seeks to mitigate this impending capability gap in the near term and to complement future capabilities, such as the Next Generation Interceptor, when they come online. Given the pace of U.S. missile defense developments since 2000, it is possible that adversary advances in capability will outpace the U.S. system’s ability to adapt. Additionally, because this layered system is in principle more readily scaled, it will almost certainly be viewed skeptically by China and Russia. In a context of growing great-power security competition, the Department of Defense (DoD) should consider undertaking a broader net assessment of the U.S., Russian, and Chinese force balance.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

CCE Phase 2: System-of-System Analysis

During Phase 1, Consequence Prioritization, the CCE Team identified High Consequence Events (HCEs) that can be accomplished through cyber means to impact critical functions, services, and processes. During Phase 2, System-of-Systems Analysis (SoS Analysis), the CCE Team will conduct a systematic review and analysis of information related to the equipment, systems, processes, operations, maintenance, testing, and procurement practices based on the HCEs identified in Phase 1.

99 GENERAL AND MISCELLANEOUS↗

1 K refrigerator for the CLAS12 Polarized Target Design, Construction, and First Results

A dynamically polarized target of protons and deuterons in irradiated NH3 and ND3 will be employed with the CLAS12 detector system to explore the spin structure of the nucleon in Hall B at Jefferson Lab. This target will feature a versatile, horizontal 1 K refrigerator that has been constructed by a collaboration of Christopher Newport University, Old Dominion University, the University of Virginia, and the JLab Target Group. A description of the challenges involved with designing the target for the CLAS12 experiments and the collaboration’s solutions will be presented. These include a modular and compact design of the 1 K refrigerator and its ancillary equipment, as well as a novel mechanism for loading the target samples. Initial test results of the system will also be included.

Brock, James↗

A Proposed Beam-Beam Test Facility COMBINE

The COmpact Machine for Beam-beam Interactions in Non-Equilibrium systems (COMBINE) is a proposed, dedicated, beam-beam test facility. This is currently a joint effort between Jefferson Lab and Old Dominion University to create a small, low energy pair of collider rings that would be used to study beam-beam interactions, as well as act as a teaching tool for students. The base design would make use of a pair of identical rings (2.5 meters per side) one rotated 180 degrees from the other, meeting at their common interaction point. These would be fed by an electron gun producing up to 125 keV electrons. The low energy will allow for beam-beam tune shifts commensurate with existing colliders, and will also allow for an exploration of the predicted effects of gear-changing, which would be performed using a variable pathlength scheme. Finally, this machine can also test linac-ring type systems.

Nissen, Edith↗

Model predictive control for integrated control of air-conditioning and mechanical ventilation, lighting and shading systems

Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Panel Session 145: Challenges and Opportunities in Establishing a System for Transportation of SNF/UNF

Issues associated with establishing a SNF Transportation System in the U.S. are complex. In part, this is because in the US when discussing SNF, there are two distinct categories. The two categories represent significant differences in ownership, transportation-regulator, and even the physical characteristics of the SNF. Specifically, the physical differences in the SNF include size of the rods, associated quantities to be shipped, cladding material, and radionuclide content/enrichment. The first is commercial SNF (i.e., that associated with nuclear power plants), owned by utilities, until a permanent repository is built with DOE obligated by law to then assume the responsibility for shipping and ownership of the SNF. Since no-permanent repository currently exists, most commercial SNF is stored near the reactor in which it was installed, hence requiring no shipments. Although current shipments of commercial SNF are very limited, the few that do occur are generally performed to support a utilities SNF consolidation effort utility and for post irradiation examination/testing. However, with approximately 83,000 metric tons currently being stored at more than 70 sites around the U.S., when a permanent repository becomes available, the required number of shipments will be extensive. The second category is DOE and research reactor fuel. These fuel rods are generally much smaller in length than commercial fuel rods, with the quantity of rods transported in a shipment significantly less than the number of rods in a typical commercial fuel assembly. Currently, most of the SNF shipments within the U.S come from this category. DOE is currently managing about 2500 metric tons of heavy metal of SNF. This panel focused on updates and status of transportation of SNF/UNF. Panelists provided updates and information on continuing impacts, risk assessment, equipment (rail cars, handling, securement), possible rail routing, and proposed inspection equipment/routing prior to shipments. Panelists with presentations: Preparing for Nuclear Waste Transportation (Daniel Ogg); Challenges and Opportunities in Establishing a System for Transportation of SNF/UNF (Kathy Langan); UNF Transportation: Challenges and Opportunities (Michael Valenzano)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PV Module Operating Temperature - Data and Resources

The Photovoltaic Systems Evaluation Laboratory (PSEL) at Sandia National Laboratories (SNL) in Albuquerque, NM has an extensive test site where PV modules and other system components are deployed and monitored for testing and evaluation. For this dataset PV Performance Labs has assembled one year of measurements from the Systems Long-Term Evaluation (SLTE) project (formerly known as PV Lifetime) providing the main variables needed to investigate and validate PV module operating temperature models: irradiance, ambient temperature, wind speed and back-of-module temperature. For use with more advanced thermal modeling, an estimate of down-welling long-wave radiation is also included.

14 SOLAR ENERGY↗

Performance Evaluation of Distributed Energy Resources Management System via Advanced Hardware-in-the-Loop Simulation: Preprint

This paper presents an advanced hardware-in-the-loop (HIL) platform to evaluate the performance of voltage regulation coordinated across advanced distribution management systems (ADMS), distributed energy management system (DERMS), and DERs. The HIL platform provides realistic laboratory testing, including accurate modeling of the real-world distribution system from a utility partner, real controller (ADMS and DERMs) and power (DERs) hardware, and standard communications protocols. The test results show proper functionalities of the integrated platform and performance of the peak load management of coordinated control systems. Based on the laboratory testing, the utility can set up the same grid automation system to manage DERs to achieve system-level control and operation objectives (e.g., peak load management), thus derisking potential issues (e.g., instability) for field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of the sensitivity of 236 U measurements in environmental samples by MC-ICP-MS and ATONA based high precision U TIMS measurements

The ATONA project is focused upon exploring the improvements in uranium isotope ratio measurements by thermal ionization mass spectrometry (TIMS) provided by a new, capacitor-based, amplifier technology. These “ATONA” Faraday amplifiers (Isotopx Ltd, UK) promise accurate, low-noise measurements of very small signals (< 1 femto-amp) in a traditional Faraday cup, which was only previously possible using an ion counter. This report outlines a series of experiments that were performed to assess the performance of the system in samples that test our rapid analysis procedures, and then compare the results against other mass spectrometry techniques currently available for environmental analyses. The following major goals were achieved: (1) illustrated the importance of 236 U measurements for the screening and analysis of environmental samples; (2) improved sensitivity for 236 U, and then identified 236 U in the 4350B standard at ultra-trace levels (3) Provided comparison of the 236 U sensitivity to multi-collector inductively coupled mass spectrometry techniques (4) Illustrated high TRL for the ATONA based measurement technique. This completes the reporting requirements for task 4 in the project LCP and highlights the utility of the system to make highly sensitive 236 U measurements in programmatically relevant sample matrices and at relevant uranium concentrations.