Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Progress Toward Gamma-Ray Imaging for Automated Holdup Measurement in Gloveboxes

Shielded gloveboxes are currently being constructed to facilitate dilution and disposal of many tons of excess plutonium oxide. Measuring holdup in these gloveboxes is expected to be challenging because of the limited available lines of sight through the glovebox shielding. A system of gamma-ray imagers is being developed to provide localization and quantification for holdup. The system will be mounted above the glovebox, where there is minimal shielding. Multiple imagers with overlapping coded-aperture fields of view are employed to enable three-dimensional reconstruction. Compton reconstruction is also available to localize sources outside the coded-aperture field of view. Improved uncertainties with respect to current techniques are expected by virtue of the fixed installation, spectroscopic performance of the detectors, and iterative image reconstruction techniques. Measurement campaigns have been undertaken at an active glovebox at Savannah River Site to test the gamma-ray imaging system in an operational environment, providing a simple test of a single imager that mimics the geometry of the installation proposed for future shielded gloveboxes. Data taken during quiescent periods in the glovebox were used to measure the buildup of material on an outlet filter and record a trend over time. Calibration data was taken with known sources to simplify analysis and provide a reliable assay of the filter. Resulting images make it possible to isolate the filter from other sources and recognize compromised data. This paper will present details of the measurement and analysis methods.

Schmitt, Kyle↗

Predicting High‐Resolution Spatial and Spectral Features in Mass Spectrometry Imaging with Machine Learning and Multimodal Data Fusion

Recent advancements in molecular Mass Spectrometry Imaging have sparked interest in integrating high spatial resolution methods with molecular mass-spectrometry-based chemical imaging. Fusion-based algorithms have proven effective in generating high spatial-resolution molecular mass spectra. However, a significant challenge stems from the differing physical mechanisms underlying image generation and data upsampling techniques, potentially leading to discrepancies in integrated information channels. Integrating physical constraints into data processing workflows is essential to tackle this issue. In this study, we propose an innovative approach that merges data from Fourier transform ion cyclotron resonance (FTICR), time-of-flight matrix-assisted laser desorption/ionization, and time-of-flight secondary ion mass spectrometry imaging techniques. By leveraging FT-ICR's unparalleled spectral resolution and ToF-SIMS's exceptional spatial resolution, we achieve submicron spatial resolution, enabling the observation of intact molecular species with remarkable spectral precision. Canonical correlation analysis is employed to incorporate physical constraints. Through sophisticated image processing and machine learning techniques, the results of this fusion hold significant promise for advancing our comprehension of complex systems and unveiling concealed molecular intricacies.

canonical correlation analysis↗

Cancer cell membrane-coated rare earth doped nanoparticles for tumor surgery navigation in NIR-II imaging window

With the attractive characteristics of low toxicity, narrow emission spectra, long fluorescence lifetime, and no photobleaching, rare-earth doped nanoparticles (RENPs) have become promising imaging nanoplatforms in the second near-infrared window (NIR-II, 1000–1700 nm). Many studies have been devoted to different surface modification strategies of RENPs to achieve good NIR-II tumor imaging property. However, the tumor imaging efficiency of these approaches remains disappointing. Herein, two methods were pursued to modify RENPs with either polyethylene glycol (PEG) or cancer-cell-membrane to generate PEGylated-RENPs and cancer-cell-membrane camouflaged RENPs (CC-RENPs), respectively. Furthermore, this study demonstrated that cancer-cell-membrane coating of RENPs greatly improved tumor imaging performance in NIR-II window than PEG coating. Besides, CC-RENPs uptakes in liver and spleen significantly decreased. Importantly, CC-RENPs was found to be capable to aid us to pursue precise resection of the tumor. In conclusion, CC-RENPs are capable of targeting tumors and show high tumor NIR-II imaging quality. They are highly promising nanomaterials for future medical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical image analysis for graphene layer detection: Enhanced green channel methodology

Graphene, a material of increasing research interest, requires accurate layer identification due to its sensitivity to layer count. Existing methods for graphene layer number identification are either time-consuming or of low accuracy, with high-accuracy methods often requiring expensive processes. This paper aims to address this challenge by proposing a cost-effective and efficient approach. Specifically, the current work highlights only the green channel—one of the three primary color channels (red, green, blue) that make up an optical image—from images of exfoliated graphene flakes for layer count identification. A linear regression is performed between pixel position and substrate green channel value, and this effect is subtracted from the entire optical image to mitigate background effects. By storing the range of green channel values for each type of flake (monolayer, bilayer, or tri-layer) based on a few images, we establish thresholds for identifying different types of layers in a particular setup. Additionally, our methodology allows for flexible threshold tuning using a single reference image, enabling adjustment to changes in detection setup such as illumination level, magnification, or microscope used. Finally, demonstrating high accuracy and flexibility, this methodology presents a suitable technique for graphene layer number identification without the need for large datasets or expensive instruments.

2D materials↗

Sequence2Self: Self-supervised image sequence denoising of pixel-level spray breakup morphology

Optical imaging of fast and transient phenomena such as the turbulent breakup of liquid sprays exhibit low signal-to-noise ratios due to the limited illumination intensity relative to the short exposure time. Image denoising is required to facilitate physical studies over these data but is challenging due to the absence of clean ground-truths and the stringency of the denoising task (e.g., strong and complex noise, limited resolution, preserving physical fidelity), preventing supervised and existing un-/self-supervised deep learning methods. To this end, Sequence2Self (Seq2S) is proposed, an extension of Self2Self (S2S) to image sequences that leverages both the signal’s spatial and temporal correlation. Seq2S is demonstrated on time-resolved x-ray phase contrast imaging of liquid jet fuel sprays in a gas turbine combustor, which possesses all of challenges detailed above. Experiments are conducted across four fuels with different breakup morphology using various state-of-the-art methods. Overall, many of the methods failed and Seq2S was most successful: (1) Accurate spray structures were reconstructed with consistent evolution across frames void of artifacts. (2) The performance was robust, invariant to the hyperparameter choice. (3) Computational time is short and can be made eligible for real-time denoising. In particular, the images denoised by Seq2S showed spray droplet diameter distributions with near-zero Kullback–Leibler divergence (0.01 ± 0.01) to a cleaner reference, whereas the second best method yielded 0.06 ± 0.03. In conclusion, this suggests that Seq2S can be reliably used prior to subsequent quantitative spray analyses as it retains (if not, improves) the statistical physical properties of the data.

97 MATHEMATICS AND COMPUTING↗

Synchrotron X-ray based particle image velocimetry to measure multiphase streamflow and densitometry

Synchrotron-based radiation techniques are increasingly used in the field of flow condition measurements. As a complicated multiphase flow, cavitation has been investigated in a wide variety of industrial fields, to prevent damages on spillways at large dams or intensify the bacteria eradication rate during water treatments. To control the detrimental effects of cavitating flows, the dynamics of and mechanisms affecting cavitation development shall be visualized and identified in real-time. Due to the large reflection and scattering effects of multiphase flow, standard visible-light imaging technologies cannot penetrate vapor bubbles and provide extremely limited information. In this study, the synchrotron source emitted high-flux X-ray pulses are used to capture flow motion and visualize internal structures with sufficiently high spatial and temporal resolutions. The image processing procedures on raw x-ray images are developed using 2D Fourier transform (FT) and wavelet transform (WT) to implement the contrast enhancement and de-noising. Through the edge detection algorithm, tracking either seeded particles or phase interfaces inside the opaque multiphase flow can be achieved to perform the particle image velocimetry. Further, with decomposing particle-only and particle-eliminated subplots from the X-ray phase-contrast image, the time-resolved velocity and void fraction fields are obtained simultaneously, paving a way for further flow condition analysis such as densitometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards the usage of quarry blasts as an active seismic source for subsurface characterization and imaging

SUMMARY Active or man-made seismic sources are often used to delineate subsurface geological structures via seismic imaging techniques. Although conventional controlled seismic sources have provided high-resolution subsurface images, the high cost of data acquisition necessitates improved use of cheaper alternative seismic sources for subsurface imaging, such as traffic noise, quarry blasts and earthquakes. Here, we explore the potential use of quarry blasts as an active seismic source for subsurface imaging. The goal of our study is to demonstrate the utility of quarry blasts as seismic sources for investigating subsurface structure with a field experiment in Mill Creek, southern Oklahoma. We deployed a 7455-m-long receiver line of 72 receivers (105 m spacing) extending away from a quarry, with a recording time of 28 d. We analyse similarities between blasts, wave types, origin time and excitation location of quarry blasts, which is important information for using such signal as an active source. Given a relative homogeneous geological condition in the study area, we could not observe clear reflected waves. However, the use of P- and S-wave velocities led to the delineation of a major basement damage zone in the study area, which further demonstrates the viability of quarry blasts as a useful seismic source for subsurface geological imaging.

58 GEOSCIENCES↗

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Water Imbibition and Oil Recovery in Shale: Dynamics and Mechanisms Using Integrated Centimeter-to-Nanometer-Scale Imaging

Water imbibition, and the associated oil displacement, is an important process in shale oil reservoirs after hydraulic fracturing and in water-based enhanced oil recovery (EOR). Current techniques for water imbibition measurement are mostly “black-box”-type methods. A more explicit understanding of the water imbibition/oil recovery dynamics and geological controls is in demand. In this paper, a multiscale imaging technique that covers centimeter to nanometer scale (i.e., core to pore scale), integrating neutron radiography, microcomputed tomography (micro-CT), and scanning electron microscope (SEM) is applied to investigate the water imbibition depth and rate and the cause of heterogeneity of imbibition in shale samples. The dynamic processes of water imbibition in the 1-in. (25.4-mm) core sample were explicitly demonstrated, and the imbibition along the matrix and imbibition through microfractures are distinguished through neutron radiography image analysis. The causes of observed imbibition heterogeneity were further investigated through micro-CT and SEM image analysis for 1.5-mm diameter miniplug samples from different laminas of the 1-in. core samples. Imbibition depth and rate were calculated on the basis of image analysis as well. Estimation of oil recovery through water imbibition in shale matrix was performed for an example shale field. Here this innovative and integrated multiscale imaging technique provides a “white/gray-box” method to understand water imbibition and water-oil displacement in shale. The wide span of the length scale (from centimeter to nanometer) of this technique enables a more comprehensive, accurate, and specific understanding of both the core-scale dynamics and pore-scale mechanisms of water imbibition, oil recovery, and matrix-fracture interaction.

04 OIL SHALES AND TAR SANDS↗

Image-Guided Intraoperative Assessment of Surgical Margins in Oral Cavity Squamous Cell Cancer: A Diagnostic Test Accuracy Review

The assessment of resection margins during surgery of oral cavity squamous cell cancer (OCSCC) dramatically impacts the prognosis of the patient as well as the need for adjuvant treatment in the future. Currently there is an unmet need to improve OCSCC surgical margins which appear to be involved in around 45% cases. Intraoperative imaging techniques, magnetic resonance imaging (MRI) and intraoral ultrasound (ioUS), have emerged as promising tools in guiding surgical resection, although the number of studies available on this subject is still low. The aim of this diagnostic test accuracy (DTA) review is to investigate the accuracy of intraoperative imaging in the assessment of OCSCC margins. By using the Cochrane-supported platform Review Manager version 5.4, a systematic search was performed on the online databases MEDLINE-EMBASE-CENTRAL using the keywords “oral cavity cancer, squamous cell carcinoma, tongue cancer, surgical margins, magnetic resonance imaging, intraoperative, intra-oral ultrasound”. Ten papers were identified for full-text analysis. The negative predictive value (cutoff < 5 mm) for ioUS ranged from 0.55 to 0.91, that of MRI ranged from 0.5 to 0.91; accuracy analysis performed on four selected studies showed a sensitivity ranging from 0.07 to 0.75 and specificity ranging from 0.81 to 1. Image guidance allowed for a mean improvement in free margin resection of 35%. IoUS shows comparable accuracy to that of ex vivo MRI for the assessment of close and involved surgical margins, and should be preferred as the more affordable and reproducible technique. Both techniques showed higher diagnostic yield if applied to early OCSCC (T1–T2 stages), and when histology is favorable.

60 APPLIED LIFE SCIENCES↗

Predictive Modeling of NOx Emissions from Lean Direct Injection of Hydrogen and Hydrogen/Natural Gas Blends Using Flame Imaging and Machine Learning

This research paper explores the use of machine learning to relate images of flame structure and luminosity to measured NOx emissions. Images of reactions produced by 16 aero-engine derived injectors for a ground-based turbine operated on a range of fuel compositions, air pressure drops, preheat temperatures and adiabatic flame temperatures were captured and postprocessed. The experimental investigations were conducted under atmospheric conditions, capturing CO, NO and NOx emissions data and OH* chemiluminescence images from 27 test conditions. The injector geometry and test conditions were based on a statistically designed test plan. These results were first analyzed using the traditional analysis approach of analysis of variance (ANOVA). The statistically based test plan yielded 432 data points, leading to a correlation for NOx emissions as a function of injector geometry, test conditions and imaging responses, with 70.2% accuracy. As an alternative approach to predicting emissions using imaging diagnostics as well as injector geometry and test conditions, a random forest machine learning algorithm was also applied to the data and was able to achieve an accuracy of 82.6%. This study offers insights into the factors influencing emissions in ground-based turbines while emphasizing the potential of machine learning algorithms in constructing predictive models for complex systems.

08 HYDROGEN↗

Deep Learning for Automated Detection and Identification of Migrating American Eel Anguilla rostrata from Imaging Sonar Data

Adult American eels (Anguilla rostrata) are vulnerable to hydropower turbine mortality during outmigration from growth habitat in inland waters to the ocean where they spawn. Imaging sonar is a reliable and proven technology for monitoring of fish passage and migration; however, there is no efficient automated method for eel detection. We designed a deep learning model for automated detection of adult American eels from sonar data. The method employs convolution neural network (CNN) to distinguish between 14 images of eels and non-eel objects. Prior to image classification with CNN, background subtraction and wavelet denoising were applied to enhance sonar images. The CNN model was first trained and tested on data obtained from a laboratory experiment, which yielded overall accuracies of >98% for image-based classification. Then, the model was trained and tested on field data that were obtained near the Iroquois Dam located on the St. Lawrence River; the accuracy achieved was commensurate with that of human experts.

13 HYDRO ENERGY↗

Description of a prototype emission-transmission computed tomography imaging system

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

NASA Discipline Musculoskeletal↗

Planetary Radar Imaging with the Deep-Space Network's 34 Meter Uplink Array

A coherent uplink array consisting of up to three 34-meter antennas of NASA's Deep Space Network has been developed for the primary purpose of increasing EIRP at the spacecraft. Greater EIRP ensures greater reach, higher uplink data rates for command and configuration control, as well as improved search and recovery capabilities during spacecraft emergencies. It has been conjectured that Doppler-delay radar imaging of lunar targets can be extended to planetary imaging, where the long baseline of the uplink array can provide greater resolution than a single antenna, as well as potentially higher EIRP. However, due to the well known R-4 loss in radar links, imaging of distant planets is a very challenging endeavor, requiring accurate phasing of the Uplink Array antennas, cryogenically cooled low-noise receiver amplifiers, and sophisticated processing of the received data to extract the weak echoes characteristic of planetary radar. This article describes experiments currently under way to image the planets Mercury and Venus, highlights improvements in equipment and techniques, and presents planetary images obtained to date with two 34 meter antennas configured as a coherently phased Uplink Array.

imaging↗

Planetary Radar Imaging with the Deep-Space Network's 34 Meter Uplink Array

A coherent Uplink Array consisting of two or three 34-meter antennas of NASA's Deep Space Network has been developed for the primary purpose of increasing EIRP at the spacecraft. Greater EIRP ensures greater reach, higher uplink data rates for command and configuration control, as well as improved search and recovery capabilities during spacecraft emergencies. It has been conjectured that Doppler-delay radar imaging of lunar targets can be extended to planetary imaging, where the long baseline of the uplink array can provide greater resolution than a single antenna, as well as potentially higher EIRP. However, due to the well known R4 loss in radar links, imaging of distant planets is a very challenging endeavor, requiring accurate phasing of the Uplink Array antennas, cryogenically cooled low-noise receiver amplifiers, and sophisticated processing of the received data to extract the weak echoes characteristic of planetary radar. This article describes experiments currently under way to image the planets Mercury and Venus, highlights improvements in equipment and techniques, and presents planetary images obtained to date with two 34 meter antennas configured as a coherently phased Uplink Array.

uplink array↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

Flexible Soft X-Ray Image Sensors based on Metal Halide Perovskites With High Quantum Efficiency

Soft X-ray imaging is a powerful tool to explore the structure of cells, probe material with nanometer resolution, and investigate the energetic phenomena in the universe. Conventional soft X-ray image sensors are by and large Si-based charge coupled devices that suffer from low frame rates, complex fabrication processes, mechanical inflexibility, and required cooling below -60 °C. Here, a soft X-ray photodiode is reported based on low-cost metal halide perovskite with comparable performance to commercial Si-based device. Nanothrough network electrode minimized the optical loss due to the shadowing of insensitive layers, while a multidimensional perovskite heterojunction is generated to reduce the photo-generated carrier loss. Further, this strategy promoted a record quantum efficiency of 8 × 10 3 % without cooling, several orders of magnitude greater than the previously achieved. Flexible and curved soft X-ray imaging arrays are fabricated based on this high-performance device structure, demonstrating stable soft X-ray response and sharp imaging capabilities. This work highlights the low-cost and efficient perovskite photodiode as a strong candidate for the next-generation soft X-ray image sensors.

36 MATERIALS SCIENCE↗

Imaging Photonic Resonances within an All‐Dielectric Metasurface via Photoelectron Emission Microscopy

Dielectric metasurfaces, through volume‐type photonic resonances, enable precise control of light‐matter interactions for applications including imaging, holography, and sensing. The application space of dielectric metasurfaces has extended from infrared to visible wavelengths by incorporating high refractive index materials, such as titanium dioxide (TiO 2 ). Understanding the fundamental and fabrication limits for these applications requires metrology with nanoscale resolution, sensitivity to electromagnetic fields within the meta‐atom volume, and far‐field excitation. In this work, photoelectron emission microscopy (PEEM) is used to image field distributions of photonic resonances in a TiO 2 metasurface excited with far‐field, visible‐wavelength illumination. The local volumetric field variations within the meta‐atoms are analyzed as a function of illumination angle and polarization by comparing photoelectron images to finite‐difference time‐domain simulations. This study determines the inelastic mean free path of very low‐energy (<1 eV) photoelectrons to be 35 ± 10 nm, which is comparable to the meta‐atom height thereby highlighting PEEM sensitivity to resonances within the volume. Additionally, the simulations reveal high sensitivity of PEEM images to an in‐plane component of the illumination k ‐vector. These results demonstrate that photoelectron imaging with subwavelength resolution offers unique advantages for examining light‐matter interactions in volume‐type (as opposed to surface) photonic modes within dielectric nanophotonic structures.

electron inelastic mean free path↗