Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controllable loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Comparison of plasma response models for RMP effects on the divertor and scrape-off layer in KSTAR

Resonant magnetic perturbations (RMPs) are beneficial for control of edge localized modes (ELMs) in tokamaks. Nevertheless, a side effect of RMPs is the appearance of helical striations in the particle and heat loads onto divertor targets. The extent and field line connection of these striations is significantly altered by the plasma response to external perturbations. For an ELM suppressed high confinement (H-mode) plasma at KSTAR, magnetic footprints are computed by FLARE based on plasma response from GPEC, MARS-F, M3D-C1 and JOREK with substantial differences in the resulting footprints (from 2 cm to 14 cm). This is reflected in EMC3-EIRENE simulations of the resulting heat loads: it is found that either the peak value or the extent of the striations appears to be overestimated compared to infrared camera measurements. Reasonable agreement can only be achieved for the smallest footprint for lower input power and lower cross-field transport, or for higher upstream density and radiative power losses.

Frerichs, H. [Univ. of Wisconsin, Madison, WI (Uni↗

Do ambient shear and thermal stratification impact wind turbine tip-vortex breakdown?

Modern wind turbines experience uneven inflow conditions across the rotor, due to the ambient flow’s shear and thermal stratification. Such conditions alter the shape and length of turbine wakes and thus impact the loads and power generation of downstream turbines. To this end, understanding the spatial evolution of the individual wakes under different atmospheric conditions is key to controlling and optimising turbine arrays. With this numerical study we aim to obtain a better understanding of the fundamental physics governing the near-wake dynamics of wind turbines under shear and thermal stability, by examining their tip-vortex breakup mechanisms. Our approach considers scale-resolving simulations of a single turbine wake under a linear shear profile as well as the application of harmonic tip perturbations to trigger flow instabilities. For the subsequent analysis we use the proper orthogonal decomposition (POD) method to extract coherent structures from the flow, and we also calculate mean kinetic energy fluxes to quantify each coherent structure’s contribution to wake recovery. The wake’s helical spiral is found to hinder wake recovery for all studied ambient flow conditions, whereas the mutual inductance instability has positive MKE flux leading to an enhanced wake recovery. Finally, the ambient shear has the largest impact on the local MKE flux with respect to downstream location by changing the shape of the curve and location of extrema, whereas thermal stratification has only a minimal impact on the magnitude of the near-wake local MKE flux distribution.

17 WIND ENERGY↗

Design of the cryogenic moderator system for the second target station

The Second Target Station (STS) at Oak Ridge National Laboratory will be a 700 kW pulsed spallation neutron source designed to provide the world's highest brightness cold neutron beams. In order to produce the required neutron performance, two compact liquid hydrogen moderators are located adjacent to the tungsten spallation target and must be supplied with less than 20 K hydrogen and a para hydrogen fraction of 99.8% or greater. The Cryogenic Moderator System (CMS) will consist of a single hydrogen loop feeding the two moderators in series cooled by a helium refrigerator with a cooling capacity of 2.5 kW at 17 K. The hydrogen loop consists of a hydrogen circulator, hydrogen helium heat exchanger, ortho-para converter, accumulator, transfer lines and heater. The design of the hydrogen loop is based on the CMS design of the First Target Station at the Spallation Neutron Source and some of the component designs may be reused. General hydrogen temperature control is provided by controlling the flowrate of helium to the heat exchanger. The hydrogen loop will have a constant flowrate of 0.5 L/s and remove a nuclear heat load of about 850 W from the two moderators, which is deposited both directly in the hydrogen and the adjacent hydrogen containing structures. Because the nuclear heat load is accelerator driven, the hydrogen system must remain stable when the heat load is removed instantaneously during beam trips. System stability is maintained passively with the accumulator and actively with the heater. Ionizing radiation which interacts with the liquid hydrogen drives backconversion of the hydrogen from parahydrogen to orthohydrogen. The STS moderator performance is very sensitive to small fractions of orthohydrogen requiring an ortho-para converter to maintain the hydrogen supplied to the moderators at near equilibrium parahydrogen concentration. STS CMS is in the early stage of preliminary design and current focus is evaluating component sizing and system stability during beam transients.

Janney, Jim↗

Lightning Current Propagation in Electrical Conduit

Investigation of lightning strikes to conductors ran through long spans of rigid steel conduit was performed. An overdamped-exponential current waveform with controlled peaks and rise rates was used to inject simulated lightning strikes. The impact of the length of wire, length of conduit, grounding location/s, and load type was investigated. Breakdown of 600 V, 12 AWG, THHN insulated wire (3.23 mm OD, 2 mm conductor diameter) was observed for voltages above 45 kV. The presence of resistive loads (between wire and ground) in excess of 20 ohms, or current rise times in excess of 5 kA/μs were found to consistently produce breakdown between wire and conduit. Practical power circuit elements such as outlets and splices were found to breakdown at voltage levels much below the wire insulation failure threshold.

47 OTHER INSTRUMENTATION↗

Data Processing Package for Cyclic Integrated Reversible Bending Fatigue Testing

A data processing software package has been introduced. The package was developed using MATLAB with the aid of the Curve Fitting Toolbox. The package is made up of four modules: pre-processing, data processing for static testing, data processing for monitoring, and data processing for measurements. CIRFT data are structured with multiple levels of architecture involving group, specimen, session, and scan/block. The degree of complexity of the data structure depends on whether a test is static or cyclic.The test results are presented in figures, scatter plots, and tables. For static testing, the output in tables provides bending mechanical properties and characteristic points of moment–curvature relation: flexural rigidities in linear segments of loading and unloading stages, intersection points between characteristic segments of the curve, and equivalent stress and strain quantities. For cyclic testing, the table output lists control and fatigue life and responsive/dependent quantities including moment, curvature, flexural rigidity, flexural hysteresis, rigidity phase angle, and equivalent stresses and strains. In addition, derivatives such as half-gage length and sensor spacing correction are included. The output also provides standard deviations of the reported quantities when they are applicable or available. The data processing package can serve as a fundamental characterization tool in mechanical study of materials. The package is intended primarily for data processing for the CIRFT process and can also be used in applications for which similar testing requirements exist.

36 MATERIALS SCIENCE↗

Report on High-Fidelity Dynamic Modeling of a Coal-Fired Steam Power Plant

As a result of the growth of renewables including solar and wind energy with fluctuating production, fossil fuel power plants are being required to cycle between high and low power production. This cycling is both at a greater frequency and over a wider range than in the past. In many cases, power plants are not designed for this type of cycling operation but can nonetheless endure these challenging operation requirements under the right conditions. In this project, optimal solution for enhanced flexible operations are being investigated using model based estimation and control techniques. To support the development of model-based estimator and model-based controls at GE Global Research, GE Steam Power configured a dynamic model using a reference steam plant design including the boiler, turbine, and water/steam conditioning systems as well as the controls needed for plant cycling with stability and reliability. The dynamic model was built using the APROS® software from VTT, and then calibrated to multiple load conditions from full load (100%TMCR) to partial loads (75%TMCR, 50%TMCR and 25%TMCR) based on internally developed steady state heat balance models at the unit level. These internal heat balance models are based on first principles and extensive engineering experiences from GE Steam Power as an OEM and a services provider. This topical report presents the structure of the unit level dynamic model, the tuning process, and representative simulation results from typical load cycling simulations using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

Hybrid circuit breakers

In one aspect, a hybrid circuit protection device for current-limiting a fault current between a source and a load during a fault is provided. The hybrid circuit protection device includes an input configured to couple to the source, an output configured to couple to the load, a return configured to couple the source to the load, a main switch configured to selectively couple the input to the output, a switching network coupled in parallel with the main switch, and a controller. The controller is configured to determine that the main switch has opened in response to the fault current, where the fault current has an initial value, and activate the switching network to current-limit the fault current to less than the initial value during the fault.

Qi, Li↗

Measuring Impact: Evaluating Thermal Zoning Simplification on Energy Efficiency Measures Analysis

Building Energy Modeling (BEM) is a versatile tool for designing, retrofitting, ensuring code compliance, obtaining certifications, qualifying for incentives, and enabling real-time building control. However, capturing all the details of building geometry for thermal zoning can be time-consuming, costly, and sometimes computationally challenging. As a result, modelers have been applying zoning simplification based on factors such as space functions and internal loads, as well as relying on their experience and judgment while adhering to zoning rules outlined in industry standards. Despite the prevalence of this common practice, a notable gap exists in the literature regarding studies quantifying the influence of simplified thermal zoning on the evaluation of Energy Efficiency Measures (EEMs). Recognizing this gap, this paper seeks to contribute to the field by enhancing the understanding of how the simplification of thermal zoning influences the evaluation of EEMs against a baseline design. The study utilized a medium office prototype model with a detailed floor plan featuring over 20 zones per floor covering diverse functional spaces with varying internal loads and occupancy schedules. A standard thermal zoning strategy outlined in ASHRAE Standard 90.1 Appendix G was employed as the simplified zoning method. This strategy condenses the zoning into a core zone and four perimeter zones per floor. It was compared with the detailed zoning approach, which involves one zone per space. Common Energy EEMs, such as enhanced envelope, high-efficiency appliances and equipment, and HVAC controls, were individually implemented and evaluated. The results indicate that the performance comparison between the two zoning methods varies depending on the type of measures considered. Basic measures, such as adding wall insulation, demonstrate similar energy impacts, while advanced HVAC control measures, such as static pressure reset, exhibit a more substantial difference that cannot be overlooked.

Xie, Jiarong↗

Introducing the 9500 Node Distribution Test System to Support Advanced Power Applications: An Operations-Focused Approach

The 9500 Node Test System is a representative section of distribution power system model developed as a part of the GridAPPS-D™ project, an effort funded by DOE as a part of the Grid Modernization Lab Consortium (GMLC) program. The test system was developed to fulfill a growing need to represent the rapidly evolving state of electric distribution systems by combining elements of legacy infrastructure systems, modern feeder topologies, and an anticipated future with smart grid technologies. It also provides a network model capable of supporting the simulation of operational scenarios such as the ones in a utility distribution control center. This test system allows the evaluation of the performance of advanced power applications in real-time, such as one that simulates the operations of an Advanced Distribution Management Systems (ADMS), Distributed Energy Resource Management Systems (DERMS), etc. in a Distribution control center. This model is an extension of the widely used IEEE 8500 Node Test Feeder and is currently being validated to become an IEEE test case to help increase adoption and widespread usage among both academia and industry. It is a full-size model representative of a section of a utility’s distribution system with multiple feeders fed from different substations. The model includes multiple distribution circuits, a sub-transmission system, multiple substations, behind the meter customer rooftop photovoltaics (PV), and multiple utility-scale distributed energy resources. To enable accurate simulations of operational scenarios, the 9500 Node Test System is designed to support procedure-based operations, with the ability to realistically demonstrate switching operations, feeder reconfiguration, adjustment of volt-var control equipment, dispatch of distributed generation, and response to planned and unplanned outages. The 9500 Node Test System includes three radial distribution feeders with 12.3 MVA of average load, consisting of both medium voltage and low voltage equipment each supplied by a different distribution substation. The three distribution feeders are connected to each other through Normally-Open switches which can be closed when needed to simulate restoration scenarios due to a fault. One feeder represents today’s grid with low penetration of customer-side renewables. The second represents a potential future grid with microgrids and 100% renewable penetration. The third has no customer generation resources, a district steam plant, and a utility-scale solar farm. The three diverse circuits were created to allow the simulation of both today’s situation as well as potential future scenarios. All three feeders have customers connected by low-voltage secondary triplex lines. This test system meets all requirements outlined in the report for creating a simulation environment that would enable discussion between key technical stakeholders as well as having the potential to accelerate operational application development and their subsequent testing and integration. The new model is a possible representation of what we believe the distribution grid may look like in the future: a high penetration of renewables, reconfigurable radial and mesh topology, numerous DERs, islanded microgrids, and significantly increased data and measurement density. The system supports both the solution of existing and newer algorithms but also enables the evaluation of applications in a realistic operational environment defined by task oriented procedural steps that represent the interaction between the control center operator and field personnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DC-Link Current Minimization Control for Current Source Converter-Based Solid-State Transformer

This article proposes a fast predictive control method and a small DC-link inductor to minimize the DC-link current in current-source converter (CSC)-based solid-state transformer. The DC-link current minimization can significantly reduce power loss and improve efficiency. The challenge of this problem is on improving both steady-state and dynamic performance. PI control methods and large DC-link inductors are conventionally used in the CSC but have limited dynamic performance. A model predictive control (MPC) method is proposed to achieve switching-cycle-level settling time, and the DC-link inductor is sized for 40% ripple to enable fast current change. Importantly, this article also proposes to minimize the DC-link current by varying the current even within a line cycle under single-phase load to improve the steady-state performance, in contrast with the reduction to a constant value in the literature. The proposed MPC features a constant switching frequency without weighting factors. The MPC does not have a high computational burden and is implemented in a regular digital controller for a prototype of soft-switching solid-state transformer (S4T) with reduced conduction loss. The effectiveness of the proposed method has been experimentally verified on the SiC S4T prototype during steady-state and dynamics under different multiport power flow conditions up to 2 kV peak. Here, the DC-link current in the experiments is close to the minimum current with a short zero-vector duration, which further verifies the performance of the proposed method.

14 SOLAR ENERGY↗

Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

Model Predictive Control (MPC) for building Heating Ventilation and Air Conditioning (HVAC) systems is beginning to gain traction in the market, with a few controls companies incorporating it into their product offerings. However, it remains difficult to assess whether the energy cost savings are enough to justify the cost of MPC implementation for a particular building, given the limited number of reported demonstrations. For small commercial and residential buildings with relatively uniform systems, standardized approaches can help lower implementation costs. In contrast, for large buildings or district systems, the potential magnitude of cost savings could justify more customized solutions. Estimating the cost-effectiveness of MPC becomes more challenging for medium and large commercial buildings, where a one-size-fits-all solution may not be suitable, and the potential energy cost savings may be insufficient to justify a customized solution. To make MPC technology more appealing, incorporating additional value streams beyond energy efficiency alone can significantly increase its attractiveness. One such revenue stream is demand flexibility, in response to dynamic electricity prices, where MPC can leverage the thermal mass of the building to shift the load and support the grid. Building on an extensive literature review of MPC field studies focused on cost savings and demand flexibility, this paper presents the results of implementing MPC control in a large office building HVAC system in Berkeley, CA. Four different dynamic electricity price profiles were integrated into the MPC objective function to shift building demand while maintaining comfort, and field testing was performed with each price profile across four seasons. The results show potential for 40–65 % demand decrease percentage and up to 61 % annual cost savings compared to the existing rule-based control strategy, under the tested dynamic price scenarios. This paper also presents a sensitivity analysis on the cost savings with respect to the price profile variability, discusses the implementation effort for the price-responsive MPC, and compares the cost savings found in this study to those found in literature on the basis of dynamic price variability, or so-called Electricity Price Relative Standard Deviation.

Zanetti, Ettore↗

Wide-Bandgap Semiconductor Amplifiers for Fusion Plasma Heating and Control

This paper discusses power electronics developed under the ARPA-E GAMOW program to support nuclear fusion power production. The goal of this project was to develop and assess the potential for wide-bandgap (WBG) semiconductor devices in power electronics to enable high-efficiency and high-voltage solid-state systems for fusion plasma generation, heating, and control. The power electronics use an architecture in which multiple high-power boards can be combined to produce megawatt-level power, where using multiple boards provides high reliability. Two main areas of power electronics boards are developed in this project for fusion plasma heating and control applications: (1) pulse generation and control and (2) radiofrequency generation. The first area is for boards capable of driving high-voltage millisecond pulses at high duty cycles. The envisioned application of these pulses is in plasma control of magnetohydrodynamic instabilities, plasma position, and edge-localized modes. Pulse-width modulation allows for the implementation of a wide variety of linear and nonlinear control systems. The boards developed for this project could actuate control coils based on digital input signals and can be parallelized to provide megawatts of output power. The design of the pulse generator is a low-side load switch. A load switch was designed and constructed that utilized 2-kV-rated field-effect transistor (FET)-based cascodes developed by Qorvo under this project to perform initial testing of these cascodes. The second area is being implemented using class E amplifiers with WBG devices and a reactance steering network to handle inductive or capacitive plasma loads. Applications include ion cyclotron resonance heating (ICRH) and high-harmonic fast-wave (HHFW) heating. A class E reactance steering network is demonstrated in modeling and experiment with a resistive-inductive load that models an inductively-coupled plasma. Power combining of boards with class E reactance steering networks is also simulated and demonstrated experimentally, to enable scaling up to high power. Modeling of high-power-density cooling and remaining useful life is conducted to enable reliable, effectively cooled high-power electronics for fusion applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DINGO: Digital assistant to grid operators for resilience management of power distribution system

With increasing adverse weather events and disasters, enabling resiliency of the power distribution system (PDS) is becoming increasingly important. Here in this work, resiliency is defined as the systems ability to keep supplying critical loads even with multiple contingencies. Resiliency may depend on: (a) advanced tools to assist operators in situational awareness and decision making with the increasing volume of data generated by the PDS, (b) visualization and ease of interaction with system resources and information, especially during extreme events and resulting human operator stress, and (c) flexible resources and autonomous control. Operators and support engineers need to interact with the system for key information and take action under stress, given the requirement for decisions in a short time. Integrated technological solutions are prevailing steps to support the most appropriate decision during critical times to serve essential loads. In order to meet the required goals, a Real-time Resiliency Monitoring and Operational Decision Support (RT-RMOD) tool have been developed. It supports various functionalities, including real-time monitoring, resilience assessment, and proactive decision support. However, this work makes advanced feature additions to the tool by developing data-enabled resilience management algorithms for (i) outage detection and localization, (ii) Resiliency-metric driven restoration and reconfiguration, and (iii) NLP based digital assistant for operators called DINGO (DIgital assistaNt to Grid Operators) to interact with Advanced Distribution Management System (ADMS) and RT-RMOD. The developed algorithm was validated for multiple cases of weather events using a real-world, off-grid microgrid system modeled in a real-time simulator, sensor data, and software tools.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-performance and high-fidelity Monte Carlo solutions to the BEAVRS benchmark

The BEAVRS (Benchmark for Evaluation and Validation of Reactor Simulation) benchmark is solved by PRAGMA, the GPU-based continuous energy Monte Carlo code. The resulting solutions are comprised of the detailed simulation results of two cycles, each of which consists of the zero power physics test (ZPPT) and the core depletion calculations. The ZPPT consists of characteristic parameters, such as critical boron concentration (CBC), control rod bank worth, isothermal temperature coefficients, and assembly-wise detector signal, which are compared with measured data provided by the benchmark administration. The core depletion calculations were performed for both the hot full power and the load follow modes, and the comparison was made with the measured or deduced CBCs and assembly-wise detector signals. In the load follow calculations, the operating power history was approximately applied to simulate the real operation as closely as possible. PRAGMA performed the various calculations with a tremendous number of histories ranging up to hundreds of millions per cycle, exploiting GPUs' massively parallel performance. The load follow run time was shorter than 16 hours on a single rack of computing nodes mounded with 24 gaming GPUs with a remarkable agreement with the measurements for most comparisons. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Virtual Cable Impedance based Load Sharing in a Microgrid for Parallel Connected Grid Forming Converters

This paper presents a novel approach to power sharing between direct connected grid-forming converters, utilizing virtual cable impedance and droop-based outer loop control. To enhance stability, resistive droop is implemented, while virtual cable impedance with non-zero resistive and inductive components ensures improved power sharing. The inner loop controller employs a Lyapunov energy function to achieve superior dynamic performance. The proposed control architecture is validated through comprehensive modeling and real-time processor-in-the-loop simulations, demonstrating its robustness and efficiency under various operating conditions. The results highlight the potential of this control strategy to improve the reliability and efficiency of renewable energy systems. Additionally, a comparative analysis with traditional methods underscores the advantages of the proposed approach in terms of stability and performance. The proposed control architecture offers a scalable and flexible solution for grid-forming converters, enabling seamless integration of renewable energy sources. Its robustness and adaptability make it an attractive solution for real-world applications. Furthermore, the approach can be extended to other power electronic systems, enhancing overall system performance and efficiency. By providing a reliable and efficient control strategy, this paper contributes to the advancement of renewable energy systems and their adoption in the energy sector. The proposed control strategy has far-reaching implications for the widespread adoption of renewable energy sources, enabling a more sustainable and efficient energy future. The overall system is modeled in MATLAB/Simulink and PLECS software domain.

grid forming converters (GFM)↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A phase-field model for non-isothermal phase transformation and plasticity in polycrystalline yttria-stabilized tetragonal zirconia

Here we propose an elastoplastic phase-field (PF) model to investigate the mechanics of tetragonal-to-monoclinic phase transformation (TMPT) and elastoplastic deformation of polycrystalline yttria-stabilized tetragonal zirconia (YSTZ). A Landau polynomial with non-vanishing chemical energy at the equilibrium temperature is introduced to account for the actual formation energies of the phases. The effects of different grain orientations, latent heat, and temperature on TMPT and deformation mechanisms are considered. The suppressive transformation effects of the grain boundaries (GBs) is modeled using an inhomogeneous kinetic coefficient in the bulk and GBs. The simulation results for single crystals demonstrate the capability of the model to reproduce the orientation-dependent compressive deformation of YSTZ similar to atomistic simulations and micropillar experiments. The single crystal with [100] crystallographic orientation along the loading direction (SC[100]) displays both TMPT and plasticity, SC[101] experiences only phase transformation, while SC[001] undergoes only plastic yielding. The TMPT induced by compressive loading exhibits shape memory effect (SME) below the equilibrium transformation temperature and pseudoelasticity above it, while the critical transformation stress increases with increasing loading temperature. The irrecoverable plastic strain is found to trap a part of the monoclinic phase, which prevents a complete reverse transformation. The polycrystalline cases also display SME and PE at low and high temperatures, respectively. Due to the orientation differences between grains and the stress concentrations at geometric nonlinearities, plastic deformation occurs in polycrystalline YSTZ for an applied load less than the yield stress. The results suggest a possible limitation of plasticity and an improvement of the shape recovery of YSTZ if one can control the orientation of the grains and/or increase the density of stacking faults at the GBs during material processing.

36 MATERIALS SCIENCE↗

Atomistic modeling of surface and grain boundary dislocation nucleation in FCC metals

Dislocation nucleation plays a critical role in the plastic deformation of crystalline materials. However, it is challenging to predict the active mode and associated rate of dislocation nucleation under typical experimental loading conditions through molecular dynamics simulation due to timescale limitations. In this report we use the free-end nudged elastic band method to determine the activation energies and activation volumes of dislocation nucleation in four typical face-centered cubic metals of Au, Al, Cu and Ni. We focus on the representative processes of surface and grain boundary dislocation nucleation. The atomistically determined activation volumes of these dislocation nucleation processes are larger than 10b3 (with b being the Burgers vector length) under typical experimental loading conditions. These results are compared with experimentally measured activation volumes in ultrafine-grained and nanocrystalline metals, thereby providing mechanistic insight into their rate-controlling deformation mechanisms.

36 MATERIALS SCIENCE↗