Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Project X”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

DARHT : Enduring Lessons from a Technical Project in a National Laboratory Context [Slides]

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility at Los Alamos National Laboratory (LANL) is the world’s first flash x-ray facility able to take multiple high-resolution radiographs of the interior features of fast-moving dense objects during a single experiment. DARHT’s radiography and complimentary diagnostics makes it an important diagnostic tool in support of the US Department of Energy’s (DOE)/National Nuclear Security Administration (NNSA)’s stewardship of the US nuclear deterrent. The project to construct DARHT ran from 1988 through 2003. Initial Operating Capability along a single axis began in 1999. A technical issue delayed Critical Decision 4 for the full dual-axis capability until 2008. DARHT was characterized by several directed changes resulting from an environmental impact study, changes to the global security context resulting from the end of underground nuclear testing, and rapid evolution of applicable technology. Conventional building and lab-space construction were part of the project, but the project was dominated by Special Facility Equipment that, together with the mission to support the nuclear weapons program, required the project to be completed by national laboratories. Although the project pre-dated implementation of DOE Order 413.3, several important lessons for national laboratory projects remain applicable today and will be discussed here, including projects appropriate for the national laboratory environment, scope stability, risk acceptance and mitigation, communication, and collaboration. Finally, considerations for DOE contractor project managers are offered based upon the DARHT experience.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Current Cold Cathode Employing Diamond and Related Materials

The essence of this project was for diamond films to be deposited on cold cathodes to improve their emission properties. Films with varying morphology, composition, and size of the crystals were deposited and the emission properties of the cathodes that utilize such films were studied. The prototype cathodes fabricated by the methods developed during Phase I were tested and evaluated in an actual high-power RF device during Phase II. These high-power tests used the novel active RF pulse compression system and the X-band magnicon test facility at US Naval Research Laboratory. In earlier tests, plasma switches were employed, while tests under this project utilized electron-beam switching. The intense electron beams required in the switches were supplied from cold cathodes embodying diamond films with varying morphology, including uncoated molybdenum cathodes in the preliminary tests. Tests with uncoated molybdenum cathodes produced compressed X-band RF pulses with a peak power of 91 MW, and a maximum power gain of 16.5:1. Tests were also carried out with switches employing diamond coated cathodes. The pulse compressor was based on use of switches employing electron beam triggering to effect mode conversion. In experimental tests, the compressor produced 165 MW in a ~ 20 ns pulse at ~18× power gain and ~ 140 MW at ~ 16× power gain in a 16 ns pulse with a ~ 7 ns flat-top. In these tests, molybdenum blade cathodes with thin diamond coatings demonstrated good reproducible emission uniformity with a 100 kV, 100 ns high voltage pulse. The new compressor does not have the limitations of earlier types of active pulse compressors and can operate at significantly higher electric fields without breakdown.

36 MATERIALS SCIENCE↗

TH-AB-209-11: Breast Microcalcification Classification Using Spectral X-Ray Coherent Scatter Computed Tomography

Purpose: To investigate the ability of Coherent Scatter Computed Tomography (CSCT) to distinguish non-invasively between type I calcifications, consisting of calcium oxalate dihydrate (CO) compounds which are more often associated with benign lesions, and type II calcifications containing hydroxyapatite (HA) which are predominantly associated with malignant tumors. Methods: The coherent scatter cross sections of HA and CO were measured using an energy dispersive x-ray diffractometer. The measured cross sections were introduced into MC-GPU Monte Carlo simulation code for studying the applicability of CSCT to discriminate between the two types of microcalcifications within the whole breast. Simulations were performed on a virtual phantom with inserted HA and CO spots of different sizes and placed in regions of interest having different background compositions. We considered a polychromatic x-ray source and an energy resolving photon counting detector. We applied an algorithm that estimates scatter components in projection space in order to obtain material-specific images of the breast. As material components adipose, glandular, HA and CO were used. The relative contrast of HA and CO components were used for type I and type II microcalcification discrimination. Results: The reconstructed CSCT images showed material-specific component-contrast values, with the highest CO or HA component contrast corresponding generally to the actual CO or HA feature, respectively. The discrimination performance varies with the x-ray intensity, calcification size, and background composition. The results were summarized using receiver operating characteristic (ROC) analysis with the area under the curve (AUC) taken as an overall indicator of discrimination performance and showing high AUC values up to unity. Conclusion: The simulation results obtained for a uniform breast imaging phantom indicate that CSCT has potential to be used as a non-invasive method for discrimination between type I and type II microcalcifications.

60 APPLIED LIFE SCIENCES↗

Data Analysis And Polarization Measurements With GEMS

The Gravity and Extreme Magnetism SMEX (GEMS) mission was selected by NASA for flight in 2014. GEMS will make the first sensitive survey of X-ray polarization across a wide range of source classes including black hole and neutron star binaries, AGN of different types, rotation and accretion-powered pulsars, magnetars, shell supernova remnants and pulsar wind nebulae. GEMS employs grazing-incidence foil mirrors and novel time-projection chamber (TPC) polarimeters leveraging the photoelectric effect. The GEMS detectors image the charge tracks of photoelectrons produced by 2 - 10 keV X-rays. The initial direction of the photoelectron is determined by the linear polarization of the photon. We present an overview of the data analysis challenges and methods for GEMS, including procedures for producing optimally filtered images of the charge tracks and estimating their initial directions. We illustrate our methods using laboratory measurements of polarized and unpolarized X-rays with flight-like detectors as well as from simulated tracks. We also present detailed simulations exploring the statistics of polarization measurements appropriate for GEMS, and make comparisons with previous work.

Stohmayer, Tod↗

Microcalorimeter measurement of x-ray spectra from a high-temperature magnetically confined plasma

A NASA-built x-ray microcalorimeter spectrometer has been installed on the MST facility at the Wisconsin Plasma Physics Laboratory and has recorded x-ray photons emitted by impurity ions of aluminum in a majority deuterium plasma. Much of the x-ray microcalorimeter development has been driven by the needs of astrophysics missions, where imaging arrays with few-eV spectral resolution are required. The goal of our project is to adapt these single-photon-counting microcalorimeters for magnetic fusion energy research and demonstrate the value of such measurements for fusion science. Microcalorimeter spectrometers combine the best characteristics of the x-ray instrumentation currently available on fusion devices: high spectral resolution similar to an x-ray crystal spectrometer and the broadband coverage of an x-ray pulse height analysis system. Fusion experiments are increasingly employing high-Z plasma-facing components and require measurement of the concentration of all impurity ion species in the plasma. This diagnostic has the capability to satisfy this need for multi-species impurity ion data and will also contribute to measurements of impurity ion temperature and flow velocity, Zeff, and electron density. Here, we introduce x-ray microcalorimeter detectors and discuss the diagnostic capability for magnetic fusion energy experiments. We describe our experimental setup and spectrometer operation approach at MST, and we present the results from an initial measurement campaign.

Eckart, M. E. (ORCID:0000000338945889)↗

Real-time High-resolution X-Ray Computed Tomography

Computed Tomography (CT) serves as a key imaging technology that relies on computationally intensive filtering and back-projection algorithms for 3D image reconstruction. While conventional high-resolution image reconstruction (> 2K3) solutions provide quick results, they typically treat reconstruction as an offline workload to be performed remotely on large-scale HPC systems. The growing demand for post-construction AI-driven analytics and the need for real-time adjustments call for high-resolution reconstruction solutions that are feasible on local computing resources, i.e. a multi-GPU server at most. In this paper, we propose a novel approach that utilizes Tensor Cores to optimize image reconstruction without sacrificing precision. We also introduce a framework designed to enable real-time execution of end-to-end distributed image reconstruction in a multi-GPU environment. Evaluations conducted on a single Nvidia A100 and H100 GPU show performance improvements of 1.91 × and 2.15 × compared to highly optimized production libraries. Furthermore, our framework, when deployed on 8-card Nvidia A100 GPU system, demonstrates the ability to reconstruct real-world datasets into 20483 volumes (32 GB) in slightly more than one minute and 40963 volumes (256 GB) in 7 minutes.

Wu, Du↗

Semiconductor Grade, Solar Silicon Purification Project

A low cost by-product, SiF4, is reacted with mg silicon to form SiF2 gas which is polymerized. The (SiF2)x polymer is heated forming volatile SixFy homologues which disproportionate on a silicon particle bed forming silicon and SiF4. The silicon analysis procedure relied heavily on mass spectroscopic and emission spectroscopic analysis. These analyses demonstrated that major purification had occured and some samples were indistinguishable from semiconductor grade silicon (except possibly for phosphorus). However, electrical analysis via crystal growth reveal that the product contains compensated phosphorus and boron.

Ingle, W. M.↗

James Webb Space Telescope Ka-Band Trade

In August 2003 James Webb Space Telescope (JWST) had its Initial Review Confirmation Assessment Briefing with NASA HQ management. This is a major milestone as the project was approved to proceed from Phase A to B, and NASA will commit funds for the project towards meeting its science goals from the Earth-Sun s Lagrange 2 (L2) environment. At this briefing, the Project was asked, "to take another look" into using, the JPL s Deep Space Network (DSN) as the provider of ground stations and evaluate other ground station options. The current operations concept assumes S-band and X-band communications with a daily &hour contact using the DSN with the goal of transmitting over 250 Gigabit (Gb) of data to the ground. The Project has initiated a trade study to look at this activity, and we would like to share the result of the trade in the conference. Early concept trades tends to focus on the "normal" operation mode of supporting telemetry (science and engineering), command and radio metrics. Entering the design phase, we find that we have the unique ranging requirement for our L2 orbit using alternating ground stations located in different hemispheres. The trade must also address emergency operations (which are covered when using the DSN). This paper describes the issues confronting this Project and how the DSN and the JWST Project are working together to find an optimized approach for meeting these issues. We believe this trade is of major interest for future Code S and other L2 missions in that JWST will set the standard.

Gal-Edd, Jonathan↗

Upgrades and redesign of the National Ignition Facility’s soft x-ray opacity spectrometer (OpSpec)

The soft x-ray Opacity Spectrometer (OpSpec) used on the National Ignition Facility (NIF) has recently incorporated an elliptically shaped crystal. The original OpSpec used two convex cylindrical crystals for time-integrated measurements of point-projection spectra from 540 to 2100 eV. However, with the convex geometry, the low-energy portion of the spectrum suffered from high backgrounds due to scattered x-rays as well as reflections from alternate crystal planes. An elliptically shaped crystal allows an acceptance aperture at the crossover focus between the crystal and the detector, which reduces background and eliminates nearly all reflections from alternate crystal planes. The current elliptical design is an improvement from the convex cylindrical design but has a usable energy range from 900 to 2100 eV. In addition, OpSpec is currently used on 18 NIF shots/year, in which both crystals are typically damaged beyond reuse, so efficient production of 36 crystals/year is required. Design efforts to improve the existing system focus on mounting reliability, reducing crystal strain to increase survivability between mounting and shot time, and extending the energy range of the instrument down to 520 eV. The elliptical design, results, and future options are presented.

Wallace, M. S. (ORCID:0000000310871216)↗

X-ray radiography of cavitation in a beryllium alloy nozzle

In this study, making quantitative measurements of the vapor distribution in a cavitating nozzle is difficult, owing to the strong scattering of visible light at gas–liquid boundaries and wall boundaries, and the small lengths and time scales involved. The transparent models required for optical experiments are also limited in terms of maximum pressure and operating life. Over the past few years, x-ray radiography experiments at Argonne’s Advanced Photon Source have demonstrated the ability to perform quantitative measurements of the line of sight projected vapor fraction in submerged, cavitating plastic nozzles. In this paper, we present the results of new radiography experiments performed on a submerged beryllium nozzle which is 520 μm in diameter, with a length/diameter ratio of 6. Beryllium is a light, hard metal that is very transparent to x-rays due to its low atomic number. We present quantitative measurements of cavitation vapor distribution conducted over a range of non-dimensional cavitation and Reynolds numbers, up to values typical of gasoline and diesel fuel injectors. A novel aspect of this work is the ability to quantitatively measure the area contraction along the nozzle with high spatial resolution. Analysis of the vapor distribution, area contraction and discharge coefficients are made between the beryllium nozzle and plastic nozzles of the same nominal geometry. When gas is dissolved in the fuel, the vapor distribution can be quite different from that found in plastic nozzles of the same dimensions, although the discharge coefficients are unaffected. In the beryllium nozzle, there were substantially fewer machining defects to act as nucleation sites for the precipitation of bubbles from dissolved gases in the fuel, and as such the effect on the vapor distribution was greatly reduced.

36 MATERIALS SCIENCE↗

WE-AB-BRA-11: Improved Imaging of Permanent Prostate Brachytherapy Seed Implants by Combining an Endorectal X-Ray Sensor with a CT Scanner

Purpose: To test feasibility of the use of a digital endorectal x-ray sensor for improved image resolution of permanent brachytherapy seed implants compared to conventional CT. Methods: Two phantoms simulating the male pelvic region were used to test the capabilities of a digital endorectal x-ray sensor for imaging permanent brachytherapy seed implants. Phantom 1 was constructed from acrylic plastic with cavities milled in the locations of the prostate and the rectum. The prostate cavity was filled a Styrofoam plug implanted with 10 training seeds. Phantom 2 was constructed from tissue-equivalent gelatins and contained a prostate phantom implanted with 18 strands of training seeds. For both phantoms, an intraoral digital dental x-ray sensor was placed in the rectum within 2 cm of the seed implants. Scout scans were taken of the phantoms over a limited arc angle using a CT scanner (80 kV, 120–200 mA). The dental sensor was removed from the phantoms and normal helical CT and scout (0 degree) scans using typical parameters for pelvic CT (120 kV, auto-mA) were collected. A shift-and add tomosynthesis algorithm was developed to localize seed plane location normal to detector face. Results: The endorectal sensor produced images with improved resolution compared to CT scans. Seed clusters and individual seed geometry were more discernable using the endorectal sensor. Seed 3D locations, including seeds that were not located in every projection image, were discernable using the shift and add algorithm. Conclusion: This work shows that digital endorectal x-ray sensors are a feasible method for improving imaging of permanent brachytherapy seed implants. Future work will consist of optimizing the tomosynthesis technique to produce higher resolution, lower dose images of 1) permanent brachytherapy seed implants for post-implant dosimetry and 2) fine anatomic details for imaging and managing prostatic disease compared to CT images. Funding: LSU Faculty Start-up Funding. Disclosure: XDR Radiography has loaned our research group the digital x-ray detector used in this work. CoI: None.

60 APPLIED LIFE SCIENCES↗

Development of X-Ray Optics for the International X-Ray Observatory (IXO)

The International X-ray Observatory requires mirror assemblies with unprecedented characteristics that cannot be provided by existing optical technologies. In the past several years, the project has supported a vigorous mirror technology development program. This program includes the fabrication of lightweight mirror segments by slumping commercially available thin glass sheets, the support and mounting of these thin mirror segments for accurate metrology, the mounting and attachment of these mirror segments for the purpose of X-ray tests, and development of methods for aligning and integrating these mirror segments into mirror assemblies. This paper describes our efforts and developments in these areas.

Zhang, William W.↗

Ultraviolet and X-ray properties of Coma’s ultra-diffuse galaxies

Many ultra-diffuse galaxies (UDGs) have been discovered in the Coma cluster, and there is evidence that some, notably Dragonfly 44, have Milky Way-like dynamical masses despite dwarf-like stellar masses. We used X-ray, ultraviolet (UV), and optical data to investigate the star formation and nuclear activity in the Coma UDGs, and we obtained deep UV and X-ray data (Swift and XMM–Newton) for Dragonfly 44 to search for low-level star formation, hot circumgalactic gas, and the integrated emission from X-ray binaries. Among the Coma UDGs, we find UV luminosities consistent with quiescence but NUV−r colours indicating star formation in the past Gyr. This indicates that the UDGs were recently quenched. The r-band luminosity declines with projected distance from the Coma core. The Dragonfly 44 UV luminosity is also consistent with quiescence, with SFR<6×10^−4M(ʘ)/yr,and no X-rays are detected down to a sensitivity of 10^38erg/s. This rules out a hot corona with a M>10^8M(ʘ) within the virial radius, which would normally be expected for a dynamically massive galaxy. The absence of bright, low-mass X-ray binaries is consistent with the expectation from the Galaxy total stellar mass, but it is unlikely if most low-mass X-ray binaries form in globular clusters, as Dragonfly 44 has a very large population. Based on the UV and X-ray analysis, the Coma UDGs are consistent with quenched dwarf galaxies, although we cannot rule out a dynamically massive population.

Chris H. Lee↗

X-ray calibration of a virtual phase 1024 x 1024 CCD

Results are presented on a calibration with X-rays of a front-illuminated virtual phase CCD with a 1024 x 1024 pixel array, performed as a part of the Solar-A preparation, which is a joint Japanese-U.S.-UK space project scheduled for a launch in August 1991. In the experiment, absolute quantum efficiency (QE) of a virtual CCD was measured at 14 wavelengths between 5.4 and 67.7 A, and its flat field responses to the illumination by C-K and Al-K X-rays were investigated together with its imaging properties in visible light. Higher than expected QE measurements were obtained at soft X-ray and EUV wavelengths; these are considered to be caused by fluorescence occurring in the absorbing layers on the CCD-entrance aperture.

Catura, R. C.↗

OC6 Phase III: Validation of Wind Turbine Aerodynamic Loading During Surge/Pitch Motion

The objective of Phase III of the Offshore Code Comparison Collaboration, Continued, with Correlation and unCertainty (OC6) project was to validate the accuracy of aerodynamic load predictions by offshore wind modeling tools for a floating offshore wind turbine as it experiences large surge-translational and pitch-rotational motion, as would occur during normal operation. The test data considered were generated at Politecnico di Milano – a wind tunnel with a robotic excitation system to emulate wave loading on the wind turbine. Testing was performed using a scaled version of the DTU 10-MW reference model, and motion was prescribed as harmonic oscillations in the surge and pitch directions, independently. A variety of models were examined in the project, performing a three-way validation between engineering-level tools, higher-fidelity tools, and measurement data from two wind tunnel experimental campaigns. The Load Cases (LC) considered in this testing are as follows: LC 1.X - Steady Wind LC 2.X - Unsteady Wind - Surge Motion LC 3.X - Unsteady Wind - Pitch Motion Details on the results of the OC6 Phase III campaign can be found in the following reference: Bergua R., et al. OC6 project Phase III: validation of the aerodynamic loading on a wind turbine rotor undergoing large motion caused by a floating support structure, Wind Energ. Sci., 8, 465–485, https://doi.org/10.5194/wes-8-465-2023, 2023.

17 WIND ENERGY↗

Neutron and X-Ray Scattering Studies of New Green Cement, and Nanoconfined Water

This is the Final report on DE-FG02-90ER45429 for the time period from September 1, 1990 to May 31, 2017. The Principal Investigator is Sow-Hsin Chen, Department of Nuclear Science and Engineering, Massachusetts Institute of Technology (MIT), Cambridge, MA 02139 (email: sowhsin@mit.edu). The Administrative Point of Contact at MIT is Sarah Svenson, Senior Contract Administrator, Office of Sponsored Programs, Tel: 617-253-2495, ssvenson@mit.edu. The DOE Program is the Office of Basic Energy Sciences (BES); Program manager is Dr. P. Thiyagarajan, Neutron Scattering SC-22.2/, Germantown Bldg., Germantown, MD 20874 . During these 27 years, the scientific activities has had a number developing emphases, as reflected from the change of Project Title in 1990 as “Construction of a Small Angle Neutron Scattering Spectrometer for Investigation of Microemulsions and Micellar Solutions in Bulk, in Porous Materials...” to “Neutron and X-Ray Scattering Studies of New Green Cement, and Nanoconfined Water” in the last renewal period, 2015-2017, with many title changes in between. Progress Report for each sub-project period was reported to DOE with detailed activity and budgetary reports. It is fair to summary that the chief activity has been in the use neutron, x-ray and laser spectroscopy to investigate materials properties of complex fluids and soft condensed matter. It started with conducting neutron and X-ray scattering experiments to study the structure and dynamics of glass-forming liquids in general first, then more specifically in the case of supercooled water in confined geometry, and culminating in the final study of new green cement. Experiments were conducted at various DOE supported national neutron facilities including ORNL, ANL, BNL and Los Alamos, as well as at NIST/NCNR. Whenever possible, experiments were also performed at numerous world-class facilities, such as those at Saclay and the Institut Laue Langevin (ILL) in Grenoble, France, and at National Synchrotron Radiation Research Center (NSRRC) in recent years in Taiwan, etc. Leveraging on the large number of international collaborate activities, a substantial percentage of activities were supported with collaborators’ own funding sources. These have help to carry out DOE’s mission and produce impressive research products far beyond what was possible with only DOE funding supports. The chief product during this period, 1990-2017, includes (1) Three hundred and eight scientific articles published in peer-reviewed and high-impacted scientific journals during 1990-2017, and a dozen monographs including four books for scientists and graduate students, (2) Twenty-four scientific conferences organized and 209 papers presented at many national and international conferences, (3) educate and train 9 post-doctoral fellows and 28 students including 22 Ph.D. students, 3 M.S. students, and 3 in other categories by providing a research experience in neutron and X-Ray scattering techniques, most of them were supported wholly or in part in the scientific topic of this award during the funding period and (4) numerous high-visibility awards and honors. This final report summarizes and details these research activities and products. At the close of this funding period, the fund from DOE has been totally spent.

07 ISOTOPE AND RADIATION SOURCES↗

Probing Ultrafast Electron (De)localization Dynamics in Mixed Valence Complexes Using Femtosecond X-ray Spectroscopy (Final Report)

The overall goal of this research program was to understand valence electron and vibrational motion following metal-to-metal charge transfer (MMCT) excitation in the mixed valence complexes dissolved in aqueous solution. The project objectives were (i) to observe the time-dependent re-arrangement of d electrons across two transition metal sites and the bridging ligand following photoinduced MMCT excitation on a sub-50 femtosecond timescale using femtosecond X-ray pulses generated at LCLS (ii) to simulate femtosecond X-ray absorption and emission spectra of solvated, photo-excited, transition metal mixed valence complexes using a realistic treatment of multi-electron correlations/transitions, spin-orbit coupling and final state lifetime effects and to propose and study the feasibility of nonlinear X-ray experiments on solvated transition metal mixed valence systems using future X-FEL light sources and (iii) to determine the role of coupled electronic and vibrational motions during ultrafast photoinduced charge transfer. The final report highlights the scientific results obtained during this funding period.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray simulation algorithms used in ISP

ISP is a simulation code which is sometimes used in the USNDS program. ISP is maintained by Sandia National Lab. However, the X-ray simulation algorithm used by ISP was written by scientists at LANL – mainly by Ed Fenimore with some contributions from John Sullivan and George Neuschaefer and probably others. In email to John Sullivan on July 25, 2016, Jill Rivera, ISP project lead, said “ISP uses the function xdosemeters_sim from the xgen library.” The is a fortran subroutine which is also used to simulate the X-ray response in consim (a descendant of xgen). Therefore, no separate documentation of the X-ray simulation algorithms in ISP have been written – the documentation for the consim simulation can be used.

97 MATHEMATICS AND COMPUTING↗