Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC FIELD COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,459 records · Page 81

Development and Test of a Large-aperture Nb3Sn Cos-theta Dipole Coil with Stress Management

The design concept of the Electron Ion Collider (EIC), which is under construction at BNL, considers adding a 2nd Interaction Region (IR) and detector to the machine after completion of the present EIC project. Recent progress with development and fabrication of large-aperture high-field magnets based on the Nb3Sn technology for the HL-LHC makes this technology interesting for the 2nd EIC IR. This paper summarizes the results of feasibility studies of large-aperture high-field Nb3Sn dipoles and quadrupoles for the 2nd EIC IR.

43 PARTICLE ACCELERATORS↗

Printed Circuit Board Based Rotating Coils for Measuring Sextupole Magnets

Here, the use of Printed Circuit Boards (PCBs) for the inductive pick-up windings of rotating coil probes has made the construction of these precision magnetic measurement devices much more accessible. This paper discusses the design details for PCBs which on each layer of the board provide for simultaneous analog bucking (suppression) of dipole, quadrupole, and sextupole field components so as to more accurately measure the higher order harmonic fields in sextupole magnets. Techniques to generate designs are discussed, as well as trade-offs to optimize sensitivity. Examples of recent sextupole PCBs and their performance are given.

43 PARTICLE ACCELERATORS↗

Ferrofluidic solenoid

An electromechanical actuator for producing mechanical force and/or motion in response to electrical signals is disclosed. The actuator includes a ferromagnetic fluid and a coil which are contained within an elastomeric capsule. Energization of the coil by application of current to a pair of coil electrodes extending through the walls of the elastomeric capsule produces distortion of the capsule, i.e., radial expansion and axial contraction. This distortion is caused by the redistribution of the ferromagnetic fluid within the capsule under the influence of the magnetic field. Variation of the current input will produce corresponding variations in the degree of capsule distortion.

Sabelman, E. E.↗

The ingestible thermal monitoring system

A thermal monitoring system for measuring body core temperatures was developed that contains an ingestible pill which is both commandable and rechargeable, and which uses magnetic induction for command and telemetry as well as for recharging. The pill electronics consist of a battery power source, a crystal-controlled oscillator that drives a small air coil, and a command detection circuit. The resulting 262-kHz magnetilc field can be easily detected from a distance of 1 m. The pill oscillator functions at voltages less than 1 V, supplied by a single Ni-Cd battery, which must be recharged after 72 h of continuous transmission. The pill can be recalibrated periodically to compensate for long-term drift.

Cutchis, Protagoras N.↗

Parameterization of asymmetry in magnetoacoustic emission by numerical processes

Two methods for processing the digitized waveform data obtained from magnetoacoustic emission measurements on a high-strength steel are investigated. Two different techniques to obtain an asymmetry parameter are presented. It is shown that the variation in this asymmetry parameter from five embrittled samples and one unembrittled steel sample can be related to the impact toughness and is not dependent on the magnetic field strength. This technique is nondestructive and is shown to determine the normalized impact toughness of a high-strength steel to better than 14 percent in the decade of interest. A comparison of a magnetoacoustic emission burst and pickup coil output from an unembrittled steel sample and an embrittled sample is illustrated.

Birt, E. A.↗

Fluid Model Analysis of the Distribution of the Negative Ion Density before the Extraction from a Tandem Type of a Plasma Source

Unified description of the expansion (through a magnetic filter) and extraction regions, including also the driver, of volume-production based sources of negative hydrogen ions is presented in the study. The model is one-dimensional, developed within the fluid plasma theory. It covers description of both the second chamber of the tandem sources and a single inductively-driven (with a planar coil) discharge of a matrix source. Four parameters have been varied in the analysis of the results: type, position and magnitude of the filter field and rf power applied for the discharge maintenance. The obtained results for the spatial distribution of the plasma parameters as well as for the electronegativity, for the negative ion beam current and its ratio to the electron current at the position of the extraction are discussed regarding optimum conditions for the source operation. The conclusion is that a magnetic field extended over a large region till the extraction favors locality in the discharge behavior and, respectively, the local production of the negative ions. This leads to high density of the extracted negative ion beam current at reasonable values of its ratio to the electron current density.

43 PARTICLE ACCELERATORS↗

SU-E-T-661: Quantitative MRI Assessment of a Novel Direction-Modulated Brachytherapy Tandem Applicator for Cervical Cancer

Purpose: To quantitatively evaluate the MR image quality of a novel direction modulated brachytherapy (DMBT) tandem applicator for cervical cancer, using the clinical MRI scanning protocol for image guided brachytherapy. Methods: The tungsten alloy-based applicator was placed in a water phantom and clinical imaging protocol was performed. Axial images were acquired using 2D turbo-spin echo (TSE) T2-weighted sequence on a 1.5T GE 450w MR scanner and an 8-channel body coil. As multi-channel receiver coil was used, inhomogeneities in the B1 receive field must be considered before performing the quantification process. Therefore the applicator was removed from the phantom and the whole imaging session was performed again for the water phantom with the same parameters. Images from the two scans were then subtracted, resulting in a difference image that only shows the applicator with its surrounding magnetic susceptibility dipole artifact. Line profiles were drawn and plotted on the difference image at various angles and locations along the tandem. Full width at half maximum (FWHM) was measured at all the line profiles to quantify the extent of the artifact. Additionally, the extent of the artifact along the diameter of the tandem was measured at various angles and locations. Results: After removing the background inhomogeneities of the receiver coil, FWHM of the tandem measured 5.75 ± 0.35 mm (the physical tandem diameter is 5.4 mm). The average extent of the artifacts along the diameter of the tandem measured is 2.14 ± 0.56 mm. In contrast to CT imaging of the same applicator (not shown here), the tandem can be easily identified without additional correction algorithms. Conclusion: This work demonstrated that the novel DMBT tandem applicator has minimal susceptibility artifact in T2-weighted images employed in clinical practice for MRI-guided brachytherapy of cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Access and limits of RMP ELM suppression with n = 1 fields in DIII-D

This work reports on DIII-D experiments aimed at extending resonant magnetic perturbation (RMP) suppression of edge localized modes (ELMs) to n = 1 fields, where n is the toroidal mode number. Modeling of the 3D ideal MHD plasma response to the RMPs using the GPEC code is used to quantify edge and core resonant fluxes, guiding experimental strategies to increase plasma resilience against core error field penetration, optimize multicoil phasing, and explore higher q 95 operation. In DIII-D, ELM mitigation is regularly observed across a wide range of n = 1 RMP scenarios. A ∼100 ms phase of complete ELM suppression was achieved at q 95 ∼ 3.9 using an odd-parity coil configuration. The suppressed phase exhibited clear signatures of RMP ELM suppression, including the elimination of Dα spikes, increased pedestal rotation, enhanced magnetic response, and elevated broadband density turbulence. An optimized coil configuration for edge-to-core resonant flux did show increased edge resonance indicated by increased density pumpout, but did not yield RMP ELM suppression. At q 95 ∼ 5.1, a bifurcation to a grassy-like ELM regime occurred, while large type-I ELMs persisted. These results demonstrate progress in experimental access to n = 1 RMP ELM suppression in DIII-D, motivating further study for robust access. This work also highlights the potential role of 3D edge stability as well as rational surface alignment in RMP ELM suppression access, which has important implications for the use of low-n RMPs in future reactor-scale devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calculation of electromagnetic force in electromagnetic forming process of metal sheet

Electromagnetic forming (EMF) is a forming process that relies on the inductive electromagnetic force to deform metallic workpiece at high speed. Calculation of the electromagnetic force is essential to understand the EMF process. However, accurate calculation requires complex numerical solution, in which the coupling between the electromagnetic process and the deformation of workpiece needs be considered. In this paper, an appropriate formula has been developed to calculate the electromagnetic force in metal work-piece in the sheet EMF process. The effects of the geometric size of coil, the material properties, and the parameters of discharge circuit on electromagnetic force are taken into consideration. Through the formula, the electromagnetic force at different time and in different positions of the workpiece can be predicted. The calculated electromagnetic force and magnetic field are in good agreement with the numerical and experimental results. The accurate prediction of the electromagnetic force provides an insight into the physical process of the EMF and a powerful tool to design optimum EMF systems.

30 DIRECT ENERGY CONVERSION↗

Magnetic quench antenna for MQXF quadrupoles

High-field MQXF-series quadrupoles are presently under development by LARP and CERN for the upcoming LHC luminosity upgrade. Quench training and protection studies on MQXF prototypes require a capability to accurately localize quenches and measure their propagation velocity in the magnet coils. The voltage tap technique commonly used for such purposes is not a convenient option for the 4.2-m-long MQXF-A prototype, nor can it be implemented in the production model. We have developed and tested a modular inductive magnetic antenna for quench localization. The base element of our quench antenna is a round-shaped printed circuit board containing two orthogonal pairs of flat coils integrated with low-noise preamplifiers. The elements are aligned axially and spaced equidistantly in 8-element sections using a supporting rod structure. The sections are installed in the warm bore of the magnet, and can be stacked together to adapt for the magnet length. We discuss the design, operational characteristics and preliminary qualification of the antenna. Lastly, axial quench localization capability with an accuracy of better than 2 cm has been validated during training test campaign of the MQXF-S1 quadrupole.

43 PARTICLE ACCELERATORS↗

Cylindrical Hall Thrusters with Permanent Magnets

The use of permanent magnets instead of electromagnet coils for low power Hall thrusters can offer a significant reduction of both the total electric power consumption and the thruster mass. Two permanent magnet versions of the miniaturized cylindrical Hall thruster (CHT) of different overall dimensions were operated in the power range of 50W-300 W. The discharge and plasma plume measurements revealed that the CHT thrusters with permanent magnets and electromagnet coils operate rather differently. In particular, the angular ion current density distribution from the permanent magnet thrusters has an unusual halo shape, with a majority of high energy ions flowing at large angles with respect to the thruster centerline. Differences in the magnetic field topology outside the thruster channel and in the vicinity of the channel exit are likely responsible for the differences in the plume characteristics measured for the CHTs with electromagnets and permanent magnets. It is shown that the presence of the reversing-direction or cusp-type magnetic field configuration inside the thruster channel without a strong axial magnetic field outside the thruster channel does not lead to the halo plasma plume from the CHT. __________________________________________________

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design study of steady-state 30-tesla liquid-neon-cooled magnet

A design for a 30-tesla, liquid-neon-cooled magnet was reported which is capable of continuous operation. Cooled by nonboiling, forced-convection heat transfer to liquid neon flowing at 2.8 cu m/min in a closed, pressurized heat-transfer loop and structurally supported by a tapered structural ribbon, the tape-wound coils with a high-purity-aluminum conductor will produce over 30 teslas for 1 minute at 850 kilowatts. The magnet will have an inside diameter of 7.5 centimeters and an outside diameter of 54 centimeters. The minimum current density at design field will be 15.7 kA/sq cm.

Prok, G. M.↗

Levitated Duct Fan (LDF) Aircraft Auxiliary Generator

This generator concept includes a novel stator and rotor architecture made from composite material with blades attached to the outer rotating shell of a ducted fan drum rotor, a non-contact support system between the stator and rotor using magnetic fields to provide levitation, and an integrated electromagnetic generation system. The magnetic suspension between the rotor and the stator suspends and supports the rotor within the stator housing using permanent magnets attached to the outer circumference of the drum rotor and passive levitation coils in the stator shell. The magnets are arranged in a Halbach array configuration.

Eichenberg, Dennis J.↗

Compact magnetic quadrupole triplet for a low-energy high-current ion beam transport

It is a difficult task to design a conventional quadrupole triplet as compact and simple as solenoids for high-current ion beam transport. In the design of a quadrupole triplet presented here, we installed three poles with the same orientation on a yoke and these were excited using two coils located between poles. This new design allows the easier fabrication of a compact quadrupole triplet compared to the conventional design. Simple equations for the preliminary design were obtained. A prototype with an aperture radius of 55 mm and a focusing power of 3.3 m{sup -1} for 50 keV proton beams was designed, fabricated, and tested. The measured field profile agreed well with the calculated profile. The length of the compact magnetic quadrupole triplet was comparable with a solenoid, and its electrical power consumption was about 40% that of a solenoid.

43 PARTICLE ACCELERATORS↗

Study of runaway electrons using the conditional average sampling method in the Damavand tokamak

Some experiments for studying the runaway electron (RE) effects have been performed using the poloidal magnetic probes system installed around the plasma column in the Damavand tokamak. In these experiments, the so-called runaway-dominated discharges were considered in which the main part of the plasma current is carried by REs. The induced magnetic effects on the poloidal pickup coils signals are observed simultaneously with the Parail–Pogutse instability moments for REs and hard X-ray bursts. The output signals of all diagnostic systems enter the data acquisition system with 2 Msample/(s channel) sampling rate. The temporal evolution of the diagnostic signals is analyzed by the conditional average sampling (CAS) technique. The CASed profiles indicate RE collisions with the high-field-side plasma facing components at the instability moments. The investigation has been carried out for two discharge modes—low-toroidal-field (LTF) and high-toroidal-field (HTF) ones—related to both up and down limits of the toroidal magnetic field in the Damavand tokamak and their comparison has shown that the RE confinement is better in HTF discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A viable dipole magnet concept with REBCO CORC ® wires and further development needs for high-field magnet applications

REBCO coated conductors maintain a high engineering current density above 16 T at 4.2 K. That fact will significantly impact markets of various magnet applications including high-field magnets for high-energy physics and fusion reactors. One of the main challenges for the high-field accelerator magnet is the use of multi-tape REBCO cables with high engineering current density in magnet development. Several approaches developing high-field accelerator magnets using REBCO cables are demonstrated. In this paper, we introduce an alternative concept based on the canted cos θ (CCT) magnet design using conductor on round core (CORC®) wires that are wound from multiple REBCO tapes with a Cu core. We report the development and test of double-layer three-turn CCT dipole magnets using CORC ® wires at 77 and 4.2 K. The scalability of the CCT design allowed us to effectively develop and demonstrate important magnet technology features such as coil design, winding, joints and testing with minimum conductor lengths. The test results showed that the CCT dipole magnet using CORC ® wires was a viable option in developing a REBCO accelerator magnet. One of the critical development needs is to increase the engineering current density of the 3.7 mm diameter CORC® wire to 540 A mm -2 at 21 T, 4.2 K and to reduce the bending radius to 15 mm. Furthermore, this would enable a compact REBCO dipole insert magnet to generate a 5 T field in a background field of 16 T at 4.2 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Generation of Intense Radiofrequency Fields in uCoils

Large amplitude radiofrequency (rf) fields hold great promise in wide line NMR where it becomes possible to excite the full breadth of the line in a quantitative fashion. Applications in quadrupole NMR and in NMR of paramagnetic systems benefit greatly from intense fields. Spin manipulations in multiple quantum NMR experiments, specifically, the generation of multiple quantum coherence in MQ NMR, are more efficiently produced using intense rf fields. In this work we describe a coil probe that produces an rf field of 25 MHz, more than five times larger than the greatest rf field reported in the literature. We accomplish this in a robust, 127 {micro}m diameter solenoid coil using 1 kW of rf power.

47 OTHER INSTRUMENTATION↗

Some aspects of achieving an ultimate accuracy during insertion device magnetic measurements by a Hall probe

An extensive test of a new Senis 2-axis Hall probe was done at the Advanced Photon Source using the Undulator A device and calibration system. This new probe has clear advantages compared with previously used Bell and Sentron Hall probes: very stable zero offset (less than the noise of 0.026 G) and compensated planar Hall effect. It can be used with proper calibration even for first and second field integral measurements. A comparison with reference measurements by long stretched coil shows that the difference in the first field integral measurement results for a 2.4-m-long Undulator A device is between 17 G cm for the best of four Hall probes used for the test and 51 G cm for the worst of them for all gap ranges from 10.5 mm to 150 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗