Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “soft”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Cost-Effectiveness Analysis of Preoperative Versus Postoperative Radiation Therapy in Extremity Soft Tissue Sarcoma

Purpose: Surgery combined with radiation therapy (RT) is the cornerstone of multidisciplinary management of extremity soft tissue sarcoma (STS). Although RT can be given in either the preoperative or the postoperative setting with similar local recurrence and survival outcomes, the side effect profiles, costs, and long-term functional outcomes are different. The aim of this study was to use decision analysis to determine optimal sequencing of RT with surgery in patients with extremity STS. Methods and Materials: A cost-effectiveness analysis was conducted using a state transition Markov model, with quality-adjusted life years (QALYs) as the primary outcome. A time horizon of 5 years, a cycle length of 3 months, and a willingness-to-pay threshold of $50,000/QALY was used. One-way deterministic sensitivity analyses were performed to determine the thresholds at which each strategy would be preferred. The robustness of the model was assessed by probabilistic sensitivity analysis. Results: Preoperative RT is a more cost-effective strategy ($26,633/3.00 QALYs) than postoperative RT ($28,028/2.86 QALYs) in our base case scenario. Preoperative RT is the superior strategy with either 3-dimensional conformal RT or intensity-modulated RT. One-way sensitivity analyses identified the relative risk of chronic adverse events as having the greatest influence on the preferred timing of RT. The likelihood of preoperative RT being the preferred strategy was 82% on probabilistic sensitivity analysis. Conclusions: Preoperative RT is more cost effective than postoperative RT in the management of resectable extremity STS, primarily because of the higher incidence of chronic adverse events with RT in the postoperative setting.

61 RADIATION PROTECTION AND DOSIMETRY↗

Particle Therapy Using Protons or Carbon Ions for Unresectable or Incompletely Resected Bone and Soft Tissue Sarcomas of the Pelvis

Purpose: To retrospectively analyze the treatment outcomes of particle therapy using protons or carbon ions for unresectable or incompletely resected bone and soft tissue sarcomas (BSTSs) of the pelvis. Methods and Materials: From May 2005 to December 2014, 91 patients with nonmetastatic histologically proven unresectable or incompletely resected pelvic BSTSs underwent particle therapy with curative intent. The particle therapy used protons (52 patients) or carbon ions (39 patients). All patients received a dose of 70.4 Gy (relative biologic effectiveness) in 32 fractions (55 patients) or 16 fractions (36 patients). Results: The median patient age was 67 years (range 18-87). The median planning target volume (PTV) was 455 cm{sup 3} (range 108-1984). The histologic type was chordoma in 53 patients, chondrosarcoma in 14, osteosarcoma in 10, malignant fibrous histiocytoma/undifferentiated pleomorphic sarcoma in 5, and other in 9 patients. Of the 91 patients, 82 had a primary tumor and 9 a recurrent tumor. The median follow-up period was 32 months (range 3-112). The 3-year rate of overall survival (OS), progression-free survival (PFS), and local control was 83%, 72%, and 92%, respectively. A Cox proportional hazards model revealed that chordoma histologic features and a PTV of ≤500 cm{sup 3} were significantly associated with better OS, and a primary tumor and PTV of ≤500 cm{sup 3} were significantly associated with better PFS. Ion type and number of fractions were not significantly associated with OS, PFS, or local control. Late grade ≥3 toxicities were observed in 23 patients. Compared with the 32-fraction protocol, the 16-fraction protocol was associated with significantly more frequent late grade ≥3 toxicities (18 of 36 vs 5 of 55; P<.001). Conclusions: Particle therapy using protons or carbon ions was effective for unresectable or incompletely resected pelvic BSTS, and the 32-fraction protocol was effective and relatively less toxic. Nevertheless, a longer follow-up period is needed to confirm these results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Control For High-Grade Nonrhabdomyosarcoma Soft Tissue Sarcoma Assigned to Radiation Therapy on ARST0332: A Report From the Childrens Oncology Group

The ARST0332 trial for pediatric and young adults with nonrhabdomyosarcoma soft tissue sarcoma (NRSTS) used risk-based treatment including primary resection with lower-than-standard radiation doses to optimize local control (LC) while minimizing long-term toxicity in those requiring radiation therapy (RT). RT for high-grade NRSTS was based on extent of resection (R0: negative margins, R1: microscopic margins, R2/U: gross disease/unresectable); those with >5 cm tumors received chemotherapy (CT; ifosfamide/doxorubicin). This analysis evaluates LC for patients assigned to RT and prognostic factors associated with local recurrence (LR).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Preoperative Hypofractionated Radiotherapy With Doxorubicin-Ifosfamide Chemotherapy in Marginally Resectable Soft Tissue Sarcomas: Results of a Phase 2 Clinical Trial

There is no standard treatment for marginally resectable soft tissue sarcomas (STSs) of the extremities and trunk wall, and current approaches produce unsatisfactory results. We hypothesized that the combination of doxorubicin-ifosfamide (AI) chemotherapy and 5 × 5 Gy hypofractionated radiotherapy can generate a higher ratio of limb-sparing or conservative surgeries with negative microscopic margins (R0) and acceptable treatment toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated 3D cytoplasm segmentation in soft X-ray tomography

Cells’ structure is key to understanding cellular function, diagnostics, and therapy development. Soft X-ray tomography (SXT) is a unique tool to image cellular structure without fixation or labeling at high spatial resolution and throughput. Fast acquisition times increase demand for accelerated image analysis, like segmentation. Currently, segmenting cellular structures is done manually and is a major bottleneck in the SXT data analysis. This paper introduces ACSeg, an automated 3D cytoplasm segmentation model. ACSeg is generated using semi-automated labels and 3D U-Net and is trained on 43 SXT tomograms of immune T cells, rapidly converging to high-accuracy segmentation, therefore reducing time and labor. Furthermore, adding only 6 SXT tomograms of other cell types diversifies the model, showing potential for optimal experimental design. ACSeg successfully segmented unseen tomograms and is published on Biomedisa, enabling high-throughput analysis of cell volume and structure of cytoplasm in diverse cell types.

59 BASIC BIOLOGICAL SCIENCES↗

Crystalline mesoporous tungsten oxide nanoplate monoliths synthesized by directed soft template method for highly sensitive NO{sub 2} gas sensor applications

Graphical abstract: Display Omitted Highlights: ► Mesoporous WO{sub 3} nanoplate monoliths were obtained by direct templating synthesis. ► Enable effective accession of the analytic molecules for the sensor applications. ► The WO{sub 3} sensor exhibited a high performance to NO{sub 2} gas at low temperature. -- Abstract: Controllable synthesis of nanostructured metal oxide semiconductors with nanocrystalline size, porous structure, and large specific surface area is one of the key issues for effective gas sensor applications. In this study, crystalline mesoporous tungsten oxide nanoplate-like monoliths with high specific surface areas were obtained through instant direct-templating synthesis for highly sensitive nitrogen dioxide (NO{sub 2}) sensor applications. The copolymer soft template was converted into a solid carbon framework by heat treatment in an inert gas prior to calcinations in air to sustain the mesoporous structure of tungsten oxide. The multidirectional mesoporous structures of tungsten oxide with small crystalline size, large specific surface area, and superior physical characteristics enabled the rapid and effective accession of analytic gas molecules. As a result, the sensor response was enhanced and the response and recovery times were reduced, in which the mesoporous tungsten oxide based gas sensor exhibited a superior response of 21,155% to 5 ppm NO{sub 2}. In addition, the developed sensor exhibited selective detection of low NO{sub 2} concentration in ammonia and ethanol at a low temperature of approximately 150 °C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of nanocrystalline zinc chromite obtained by two soft chemical routes

Graphical abstract: - Highlights: • Two soft chemical routes to synthesize zinc chromites are described. • Glycine is used as chelating agent (precursor method) and fuel (solution combustion method). • The synthesized chromites have crystallite size in the range of 18–27 nm. • An antiferromagnetic (AFM) transition is observed at about T{sub N} ∼ 18 K. - Abstract: Zinc chromite (ZnCr{sub 2}O{sub 4}) nanocrystalline powders were obtained by two different chemical routes: the precursor method and the solution combustion method involving glycine-nitrates. The complex compound precursors, [ZnCr{sub 2}(NH{sub 2}CH{sub 2}COO){sub 8}]·9H{sub 2}O and [ZnCr{sub 2}(NH{sub 2}CH{sub 2}COOH){sub 4.5}]·(NO{sub 3}){sub 8}·6H{sub 2}O, were characterized by chemical analysis, infrared spectroscopy (IR), ultraviolet–visible spectroscopy (UV–vis) and thermal analysis. The structure, morphology, surface chemistry and magnetic properties of ZnCr{sub 2}O{sub 4} powders were investigated by X-ray diffraction (XRD), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), infrared and Raman spectroscopy (RS), ultraviolet–visible spectroscopy (UV–vis) and magnetic measurements. X-ray diffraction patterns indicated the chromite spinel phase with good crystallinity and an average crystallite size of approximately 18–27 nm. The band gap values ranged between 3.31 and 3.33 eV. The magnetic measurements indicated an antiferromagnetic transition at T{sub N} ∼ 17.5/18 K.

36 MATERIALS SCIENCE↗

Nanostructure refinement and phase formation of flash annealed FeNi-based soft magnetic alloys

In this work, the resulting nanocomposite microstructures of FeNi nanocrystallites under different heating and cooling rates (5 °C/min vs 400-500 °C/s) is investigated. Conventional furnace annealing under low heating rates and slow cooling resulted in both BCC α-FeNi and FCC γ-FeNi nanocrystallites with an average grain size on the order of 25-27 nm whereas high heating rates achieved via flash annealing techniques have enabled a dramatically refined microstructure consisting of 5-7 nm grains with FCC γ-FeNi phase and found to be the dominant phase following primary crystallization. Grain size refinement and phase identity optimization yielded low values of coercivities-17 A/m and high permeability similar to 11 x 10 3 measured at 400 Hz/1 kA/m in flash annealed samples at 450 °C for 5 s. The magnetic behavior and the underlying mechanism of optimal soft magnetic properties are discussed in terms of the critical role of the grain size in domain wall pinning and coercivity.

36 MATERIALS SCIENCE↗

A Device and Procedure for Immobilization of Patients Receiving Limb-Preserving Radiotherapy for Soft Tissue Sarcoma

The purpose of this study was to determine the accuracy and efficiency of a custom-designed immobilization device for patients with extremity soft-tissue sarcoma. The custom device consisted of a thermoplastic shell, vacuum pillow, and adaptable baseplate. The study included patients treated from January 2005 to March 2007, with 92 patients immobilized with the custom device and 98 with an established standard. Setup times for these cohorts were analyzed retrospectively for conformal and intensity modulated radiotherapy techniques (IMRT). Thigh tumor setup times were analyzed independently. A subset of patients treated with IMRT was analyzed for setup error using the radiographically verified isocenter position measured daily with electronic portal imaging and cone-beam computed tomography. Mean setup time was reduced by 2.2 minutes when using the custom device for conformal treatment (p = 0.03) and by 5.8 min for IMRT of thigh tumors (p = 0.009). All other setup time comparisons were not significant. A significant systematic error reduction was seen in all directions using the custom device. Random error standard deviations favored the custom device. The custom device offers immobilization advantages. Patient setup time was reduced for conformal techniques and IMRT of thigh tumors. Positioning uncertainty was improved, permitting a reduction of the planning target volume margin by 2 to 4 mm.

61 RADIATION PROTECTION AND DOSIMETRY↗

Immobilization and image-guidance methods for radiation therapy of limb extremity soft tissue sarcomas: Results of a multi-institutional survey

Radiation therapy for limb-extremity soft tissue sarcoma (STS) requires accurate, reproducible dose delivery. However, patient positioning is challenging and there is a lack of existing guidelines to assist institutional standardization. Therefore, we conducted a multi-institutional international survey of STS immobilization, image guidance methods, and treatment protocols to investigate current practice. Seventy-three UK radiotherapy centers and 15 hospitals in 7 other countries completed a questionnaire on STS immobilization and image-guidance procedures. Specifically, the survey collated information on the current usage of immobilization equipment, including custom devices, patient setup tolerances, the use of written protocols, the modality and frequency of image guidance, the method of treatment, allocated treatment times, and the application of surgical clips. Multiple combinations of immobilization devices were reported. In the UK, 12%, 40%, 30%, 12%, and 5% use 1, 2, 3, 4, and 5 types of device for lower limb STS. Vacuum bag plus either foot or ankle support was most common (66%). Of 15 international centers, 27%, 60%, 7%, 0%, 7% use 1, 2, 3, 4, 5 devices, with vacuum bags (73%) and thermoplastic (47%) predominant, similar to UK values of 77% and 52%. For image guidance, in the UK, 37% use kV planar, 34% use MV planar, and 16% use cone-beam CT for the first 3 fractions and then weekly. Internationally, daily imaging was more prevalent with 33% using kV planar, 7% MV planar, and 40% cone-beam CT daily. Custom devices plus combinations of devices, along with 5- and 10-mm set-up tolerances, were most commonly reported. Less than half of centers have written treatment protocols. Conventional treatment is most common in the UK, with only 42% using conformal techniques. Treatment is allocated between 10 and 30 minutes. Twenty-six percent of UK centers and 53% of international centers use surgical clips. Across treatment centers, there is no consistent approach to STS immobilization, image-guidance methods, or treatment protocols assessed by this survey. A wide variety of immobilization devices and configurations are utilized, and the frequency and modality of imaging are similarly diverse. In the absence of guidelines, the creation of an online repository of example immobilization techniques could enable centers to compare a diversity of cases. The availability of a forum for viewing and discussing a range of cases could potentially lead to improved patient setup and reduce the time taken to devise an individual immobilization strategy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Additive manufacturing of soft and hard magnetic materials used in electrical machines

Soft and hard magnetic materials were fabricated using additive manufacturing (AM) for use in 3D electrical machines. The effect of the characteristics and the nature of the magnetic feedstock powders was evaluated for both the cold spray (CS) and the fused filament fabrication (FFF) processes. 3D finite element analysis (FEA) was used to develop new motor topologies based on the advantages offered by AM. FEA optimization also allowed the identification of the most critical material properties and is thus a powerful tool to facilitate material development.

Bernier, Fabrice↗

Anti-contamination device for cryogenic soft X-ray diffraction microscopy

Cryogenic microscopy allows one to view frozen hydrated biological and soft matter specimens with good structural preservation and a high degree of stability against radiation damage. We describe a liquid nitrogen-cooled anti-contamination device for cryogenic X-ray diffraction microscopy. The anti-contaminator greatly reduces the buildup of ice layers on the specimen due to condensation of residual water vapor in the experimental vacuum chamber. We show by coherent X-ray diffraction measurements that this leads to fivefold reduction of background scattering, which is important for far-field X-ray diffraction microscopy of biological specimens.

36 MATERIALS SCIENCE↗

Superlattice-enhanced silicon soft X-ray and charged particle detectors with nanosecond time response

Here, silicon detectors are an essential measurement tool for Inertial Confinement Fusion and High-Energy-Density Physics Applications, where temporal response of the order of nanoseconds is essential. Soft X-rays (<1 keV), Ultraviolet light, and low-energy electrons (<10 keV) can provide essential information in diagnosing rapidly changing plasma conditions, but reducing the detector dead layer is essential to improving detector response for these shallowly absorbed particles. This paper details a study of silicon detector surface preparation methods such as ion implant parameters, and the addition of a quantum 2D superlattice, to produce fast detectors that are highly sensitive to shallowly absorbed radiation. Measurements of visible light quantum efficiency, electron responsivity, and pulsed x-ray response indicate that detectors with a 2-layer superlattice enjoy a significant benefit over equivalent detectors using an ion implant at the illuminated surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for soft unclustered energy patterns produced in association with a W or Z boson in proton-proton collisions at $\sqrt{s}$ = 13 TeV

A search for a Higgs boson produced in association with a W or Z boson and decaying via a soft unclustered energy pattern (SUEP) is presented. The analysis is based on proton-proton collision data corresponding to an integrated luminosity of 138 fb −1 collected between 2016 and 2018 at the LHC. Final states with a leptonic W or Z boson decay associated with a high multiplicity of low-momentum charged particles are explored for the first time. The results show no significant excess over the standard model background expectation. Limits are set on the production cross section of a Higgs boson that decays to a SUEP, for a range of parameters of the SUEP model. Material is provided to facilitate further interpretation of the results.

CMS↗

Computer-Aided Treatment Design of a Distal Upper Extremity Soft Tissue Tumor with Electron Beam Radiotherapy

We present here a novel approach for the planning and treatment of a distal upper extremity soft tissue tumor. Utilizing computed tomography (CT) based electron dose calculations, a customized compensating wax bolus was designed in order to deliver sufficient dose coverage to the tumor volume while sparing the draining lymphatics of the patient’s hand and digits. A clinical case is presented as well as the design and construction of the compensator. Outcome and clinical implications are discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sulfate Speciation Analysis Using Soft X-ray Emission Spectroscopy

It is reported that the chemical and electronic structures of 15 different sulfates are studied using S L 2,3 soft X-ray emission spectroscopy (XES). Sulfur L 2,3 XES spectra of sulfates are distinctively different from those of other sulfur compounds, which makes XES a powerful technique for sulfate detection. Furthermore, subtle but distinct differences between the spectra of sulfates with different cations are observed, which allow a further differentiation of the specific compound. Most prominently, the position and width of the emission from "S 3s" derived bands systematically vary for different compounds, which can be understood with electronic structure and spectral calculations based on density functional theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗