Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WAVEGUIDES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Overview of Photonic Materials for Application in Space Environments

Future space systems will he based on components evolving from the development and refinement of new and existing photonic materials. Optically based sensors, inertial guidance, tracking systems, communications, diagnostics, imaging and high speed optical processing are but a few of the applications expected to widely utilize photonic materials. The response of these materials to space environment effects (SEE) such as spacecraft charging, orbital debris, atomic oxygen, ultraviolet irradiation, temperature and ionizing radiation will be paramount to ensuring successful space applications. The intent of this paper is to, address the latter two environments via a succinct comparison of the known sensitivities of selected photonic materials to the temperature and ionizing radiation conditions found in space and enhanced space environments Delineation of the known temperature and radiation induced responses in LiNbO3, AlGaN, AlGsAs,TeO2, Si:Ge, and several organic polymers are presented. Photonic materials are realizing rapid transition into applications for many proposed space components and systems including: optical interconnects, optical gyros, waveguide and spatial light modulators, light emitting diodes, lasers, optical fibers and fiber optic amplifiers. Changes to material parameters such as electrooptic coefficients, absorption coefficients, polarization, conductivity, coupling coefficients, diffraction efficiencies, and other pertinent material properties examined for thermo-optic and radiation induced effect. Conclusions and recommendations provide the reader with an understanding of the limitations or attributes of material choices for specific applications.

Taylor, E. W.↗

Microgravity Processing and Photonic Applications of Organic and Polymeric Materials

In recent years, a great deal of interest has been directed toward the use of organic materials in the development of high-efficiency optoelectronic and photonic devices. There is a myriad of possibilities among organic which allow flexibility in the design of unique structures with a variety of functional groups. The use of nonlinear optical (NLO) organic materials such as thin-film waveguides allows full exploitation of their desirable qualities by permitting long interaction lengths and large susceptibilities allowing modest power input. There are several methods in use to prepare thin films, such as Langmuir-Blodgett (LB) and self-assembly techniques, vapor deposition, growth from sheared solution or melt, and melt growth between glass plates. Organics have many features that make Abstract: them desirable for use in optical devices such as high second- and third-order nonlinearities, flexibility of molecular design, and damage resistance to optical radiation. However, their use in devices has been hindered by processing difficulties for crystals and thin films. In this chapter, we discuss photonic and optoelectronic applications of a few organic materials and the potential role of microgravity on processing these materials. It is of interest to note how materials with second- and third-order nonlinear optical behavior may be improved in a diffusion-limited environment and ways in which convection may be detrimental to these materials. We focus our discussion on third-order materials for all-optical switching, and second-order materials for all-optical switching, and second-order materials for frequency conversion and electrooptics.

Frazier, Donald 0↗

RF Transmission Lines on Silicon Substrates

A review of RF transmission lines on silicon substrates is presented. Through measurements and calculated results, it is shown that attenuation is dominated by conductor loss if silicon substrates with a resistivity greater than 2500 Ohm-cm are used. Si passivation layers affect the transmission line attenuation; however, measured results demonstrate that passivation layers do not necessarily increase attenuation. If standard, low resistivity Si wafers must be used, alternative transmission lines such as thin film microstrip and Co-Planar Waveguide (CPW) on thick polyimide layers must be used. Measured results presented here show that low loss per unit length is achievable with these transmission lines.

Ponchak, George E.↗

Endothelium Preserving Microwave Treatment for Atherosclerosis

Method and apparatus are provided to treat atherosclerosis wherein the artery is partially closed by dilating the artery while preserving the vital and sensitive endothelial layer thereof Microwave energy having a frequency from 3 GHz to 300 GHz is propagated into the arterial wall to produce a desired temperature profile therein at tissue depths sufficient for thermally necrosing connective tissue and softening fatty and waxy plaque while limiting heating of surrounding tissues including the endothelial laser and/or other healthy tissue, organs, and blood. The heating period for raising the temperature a potentially desired amount, about 20 C., within the atherosclerotic lesion may be less than about one second. In one embodiment of the invention, a radically beveled waveguide antenna is used to deliver microwave energy at frequencies from 25 GHz or 30 GHz to about 300 GHz and is focused towards a particular radial sector of the artery. Because the atherosclerotic lesions are often asymmetrically disposed, directable of focussed heating preserves healthy sectors of the artery and applies energy to the asymmetrically positioned lesion faster than a non-directed beam. A computer simulation predicts isothermic temperature profiles for the given conditions and man be used in selecting power, pulse duration, beam width, and frequency of operation to maximize energy deposition and control heat rise within the atherosclerotic lesion without harming healthy tissues or the sensitive endothelium cells.

Carl, James R.↗

An Evanescent Microwave Probe for Super-Resolution Nondestructive Imaging of Metals, Semiconductors, Dielectrics, Composites and Biological Specimens

Using evanescent microwaves with decay lengths determined by a combination of microwave wavelength (lambda) and waveguide termination geometry, we have imaged and mapped material non-uniformities and defects with a resolving capability of lambda/3800=79 microns at 1 GHz. In our method a microstrip quarter wavelength resonator was used to generate evanescent microwaves. We imaged materials with a wide range of conductivities. Carbon composites, dielectrics (Duroid, polymers), semiconductors (3C-SiC, polysilicon, natural diamond), metals (tungsten alloys, copper, zinc, steel), high-temperature superconductors, and botanical samples were scanned for defects, residual stresses, integrity of brazed junctions, subsurface features, areas of different film thickness and moisture content. The evanescent microwave probe is a versatile tool and it can be used to perform very fast, large scale mapping of a wide range of materials. This method of characterization compares favorably with ultrasound testing, which has a resolution of about 0.1 mm and suffers from high absorption in composite materials and poor transmission across boundaries. Eddy current methods which can have a resolution on the order of 50 microns are restricted to evaluating conducting materials. Evanescent microwave imaging, with careful choice of operating frequency and probe geometry, can have a resolution of up to 1 micron. In this method we can scan hot and moving objects, sample preparation is not required, testing is non-destructive, non-invasive and non-contact, and can be done in air, in liquid or in vacuum.

Pathak, P. S.↗

Effects of Geometric Azimuthal Asymmetries of the PPM Stack on Electron Beam Characteristics

The effects of geometric azimuthally asymmetric properties of a periodic permanent magnet (PPM) focusing stack on electron beam characteristics obtained using a fully three dimensional (3D) particle-in-cell (PIC) code will be presented. The simulation model, using MAFIA (Solution of MAxwell's equations by the Finite-Integration-Algorithm), incorporates 3D behavior of the beam immersed in static fields calculated directly from the exact geometry and material properties of the 3D magnetic focusing structure. The Hughes 8916H, 18-40 GHz helical TWT for the millimeter-wave power module (MMPM) was used as a prototype. Firstly, the effects of C-magnets used at the input and output of the TWT to allow for coupling of the RF signal into and out of the tube are considered. The 8916H input and output C-magnets differ because coaxial couplers are used at the input and waveguide couplers are used at the output The repositioning of the beam from its central axis due to the inclusion of the output C-magnet was found to be most significant. The modeled output C-magnet and its orientation in the Cartesian coordinate system is shown, and a two-dimensional beam profile including the output C-magnet is also shown. A table presents the shift of the beam center off the central axis relative to the average radius of the beam at the longitudinal points A, B and C designated on an enclosed figure. Secondly, the addition of shunts, or rectangular iron pieces applied manually by a skilled technician in order to improve beam transmission, is considered. The shunts are applied to the top of the tube; thus, azimuthal symmetry of the focusing stack is interrupted. Although shunts are typically added during RF focusing, they are also typically added at the input section of the tube where RF forces are minimal, making an electron optics analysis meaningful. Because several shunts are usually applied to one pole piece, the simulations have been simplified by modeling a half washer with the same radius and longitudinal length as a shunt over the entire x, positive-y half of the transverse plane. A modeled pole piece and shunt as described are shown. Lastly, in order to study the effects of magnet misalignments, a magnet in the PPM stack was arbitrarily chosen and adjusted so that its central axis was shifted both 0.7 percent and 1.0 percent of the magnet outer diameter in the positive-y direction. In practice, positioning the magnets so that their central axis is accurately aligned with the central axis of the tube is challenging. Thus, it is a strong possibility that one or more magnets will be misaligned relative to the tube central axis.

Kory, Carol L.↗

High Frequency Interconnects on Silicon Substrates

The measured propagation constant of coplanar waveguide (CPW) on silicon wafers as a function of the line dimensions and the resistivity of the Si wafer; CPW on GaAs wafers as a function of the line dimensions, and thin film microstrip (TFMS) polyimide fabricated with polyimide on the surface of a silicon wafer is presented. It is shown that the attenuation of CPW on 2500 Omega-cm Si wafers and-of TFMS with a polyimide thickness of 4 micrometer or greater is comparable to the attenuation of similar lines on GaAs.

Ponchak, George E.↗

Coupling Light from a High-Q Microsphere Resonator Using a UV-induced Surface Grating

High-Q microspheres with whispering-gallery modes have very narrow resonances that can be used for fiber-optic filters, ultra-compact narrow-linewidth lasers and optical/microwave oscillators. Whispering-gallery modes were previously excited in microspheres using evanescent optical fields. The necessary phase synchronism was obtained by adjusting the incident angle of input light beam (prism coupler) or adjustment of the waveguide propagation constant (fiber taper coupler). For many applications, however, bulky near-field couplers are undesirable. They compromise the symmetry and generate stray fields. Also, the control of coupling is crucial for the performance of microsphere resonators: in analogy with radio frequency circuits, the loading Q-factor should be less than the intrinsic Q-factor, Q(sub L) less than or equal to Q(sub O). Ideally one should combine a stable coupling element and a resonator into a single microsphere component.

Ilchenko, V. S.↗

On-Wafer Testing of Circuits Through 220 GHz

We have jointly developed the capability to perform on-wafer s-parameter and noise figure measurements through 220 GHz. S-parameter test sets have been developed covering full waveguide bands of 90-140 GHz (WR-08) and 140-220 GHz (WR-05). The test sets have been integrated with coplanar probes to allow accurate measurements on-wafer. We present the design and performance of the test sets and wafer probes. We also present calibration data as well as measurements of active circuits at frequencies as high as 215 GHz.

Gaier, Todd↗

A Hot-Electron Far-Infrared Direct Detector

A new approach is proposed to improve the sensitivity of direct-detection bolometers at millimeter, submillimeter and far-infrared wavelengths. The idea is to adjust a speed of the thermal relaxation of hot-electrons in a nanometer size normal metal or super-conductive transition edge bolometer by controlling the elastic electron mean free path. If the bolometer contacts are made of a superconductor with high critical temperature (Nb, Pb etc.) then the thermal diffusion into the contacts is absent because of the Andreev's reflection and the electron-phonon relaxation is the only mechanism for heat removal. The relaxation rate should behave as T(sup 4)l at subkelvin temperatures (l is the electron elastic mean free path) and can be reduced by factor of 10-100 by decreasing l. Then an antenna- or waveguide-coupled bolometer with a time constant about 10(exp -3) to 10(exp -5) s at T approximately equals 0.1-0.3 K will exhibit photon-noise limited performance in millimeter and submillimeter range. The choice of the bolometer material is a tradeoff between a low electron heat capacity and fabrication. A state-of-the-art bolometer currently offers NEP = 10(exp -17) W(Square root of (Hz)) at 100 mK along with a approximately equals 2 msec time constant. The bolometer we propose will have a figure-of-merit, NEP(square root (r)), which is 10(exp 3) times smaller. This will allow for a tremendous increase in speed which will have a significant impact for observational mapping applications. Alternatively, the bolometer could operate at higher temperature with still superior sensitivity. This device can significantly increase a science return and reduce the cost for future observational missions. This research was performed by the Center for Space Microelectronics Technology, Jet Propulsion Laboratory, California Institute of Technology, and was sponsored by NASA, Office of Space Science.

Karasik, B. S.↗

A Low Noise NbTiN-Based 850 GHz SIS Receiver for the Caltech Submillimeter Observatory

We have developed a niobium titanium nitride (NbTiN) based superconductor- insulator-superconductor (SIS) receiver to cover the 350 micron atmospheric window. This frequency band lies entirely above the energy gap of niobium (700 GHz), a commonly used SIS superconductor. The instrument uses an open structure twin-slot SIS mixer that consists of two Nb/AlN/NbTiN tunnel junctions, NbTiN thin-film microstrip tuning elements, and a NbTiN ground plane. The optical configuration is very similar to the 850 GHz waveguide receiver that was installed at the Caltech Submillimeter Observatory (CSO) in 1997. To minimize front-end loss, we employed reflecting optics and a cooled beamsplitter at 4 K. The instrument has an uncorrected receiver noise temperature of 205K DSB at 800 GHz and 410K DSB at 900 GHz. The degradation in receiver sensitivity with frequency is primarily due to an increase in the mixer conversion loss, which is attributed to the mismatch between the SIS junction and the twin-slot antenna impedance. The overall system performance has been confirmed through its use at the telescope to detect a wealth of new spectroscopic lines.

Kooi, J. W.↗

Hydrostatic Adjustment in Vertically Stratified Atmospheres

Hydrostatic adjustment due to diabatic heat in two nonisothermal atmospheres is examined. In the first case the temperature stratification is continuous; in the second case the atmosphere is composed of a warm, isothermal troposphere and a colder, isothermal semi-infinitely deep stratosphere.In both cases hydrostatic adjustment, to a good approximation, follows the pattern found in the Lamb problem (semi-infinitely deep. isothermal atmosphere): Initially we have acoustic waves with the kinetic energy increasing or decreasing at the expense of available elastic energy. After this initial period the acoustic waves evolve into acoustic-gravity waves with the kinetic, available potential and available elastic energies interacting with each other. Relaxation to hydrostatic balance occurs within a few oscillations. Stratification in an atmosphere with a continuous temperature profile affects primarily the shape and amplitude of the disturbances. In the two-layer atmosphere, a certain amount of energy is trapped in the tropospheric waveguide as disturbances reflect off the tropopause and back into the troposphere. With each internal reflection a portion of this trapped energy escapes and radiates to infinity.

Duffy, Dean G.↗

Measurements of Beam Coupling in the Marshall Magnetic Mirror Device

Experimental investigations of the coupling of an electron beam into a magnetically confined plasma have been undertaken at the Marshall Space Flight Center using the Marshall Magnetic Mirror (M3) system. The M3 system is composed of the following: two magnet coils; a cylindrical vacuum vessel; microwave source; and electron beam source. The magnet coils, which form the magnetic mirror, have an inner diameter of 25.4 cm and an outer diameter of 50.8 cm. The coils are composed of 9 coil segments with 33 turns in each segment. Each coil segment is connected in series. To create the target plasma, a 2 kW microwave source (2.45 gHz) is coupled into the vacuum chamber via waveguide. The electron beam source is a hollow cathode device created by the EPL Corporation. The hollow cathode is capable of producing a 50 amp beam with a pulse length of 1 second. It is also capable of continuous operation at 5 amps. The hollow cathode is mounted on one end of the cylindrical vacuum vessel 24 cm outside of a magnet coil. A current sensor is placed in the hollow cathode keeper bias circuit to measure emission current.

Schneider, T. A.↗

Dependence of the Element Patterns of HYDROSTAR on Mutual Coupling

HYDROSTAR is a hybrid synthesis radiometer, intended for spaceborne applications, which employs a real aperture (waveguide stick antenna) for resolution along track and employs aperture synthesis to obtain resolution across track. This L-band system is an extension of the successful aircraft prototype, the Electronically Steered Thinned Array Radiometer (ESTAR). A proof-of-concept, full size system was constructed (45 wavelength in the synthesis direction) and subjected to extensive antenna pattern and associated microwave component measurements in an outdoor antenna test facility. HYDROSTAR employs a thinned array of 16 elements each 5.8 inches long in the along track dimension and spanning 9.5 inches across track. Each element is a narrow-wall shunt slot array with 36 slots. The polarization is linear (along-track). In the across track dimension, the antennas are deployed in a minimum redundancy array which has 90 independent baselines spaced in integer multiples of half a wavelength. The closest spacings used are for the first three elements at each end, which are spaced by only one-half wavelength. This study was intended to assess how closely each of 16 stick element patterns compare with their nominal values (as an individual, isolated radiator), when installed in their intended composite thinned array configuration. Extensive pattern measurements of the 16 elements that constitute the HYDROSTAR antenna subsystem were conducted to observe their relative features along the synthesis plane. Data was also collected for the mutual coupling between pairs of selected antennas. All antenna patterns had features different from that of an isolated element indicating some level of interaction among neighboring radiators. Those elements which had nearest neighbors at least five wavelengths away were located near the middle of the array. Their radiation patterns displayed sonic small, symmetric ripple across their full azimuth range. The patterns of elements that lie within 2.5 wavelengths of their neighbors showed stronger and asymmetric features. These are believed to be caused by mutual coupling among these structures. Evidence for this was seen when an antenna position was displaced by 0.05 wavelengths, Its pattern and those of its near neighbors were seen to change. Displacement within the plane of the array were observed to have different effects than displacements out-of-plane. A program of data analysis and theoretical development is in progress to provide a physical interpretation of the properties of these antenna patterns and to develop methods which can optimize the performance of this synthetic aperture imaging system. This includes compensation for pattern asymmetries and element position perturbation.

Weissman, David E.↗

A Hot-electron Direct Detector for Radioastronomy

A new approach is proposed to improve the sensitivity of direct-detection bolometers. The idea is to adjust a speed of the thermal relaxation of hot-electrons in a nanometer size normal metal or superconductive transition edge bolometer by controlling the elastic electron mean free path. If the bolometer contacts are made of a superconductor with high critical temperature then the thermal diffusion into the contacts is absent because of the Andreev's reflection and the electron-phonon relaxation is the only mechanism for heat removal. The relaxation rate should behave as 7(exp 4)l at subkelvin temperatures (l is the electron elastic mean free path) and can be reduced by factor of 10 - 100 by decreasing l. Then an antenna- or waveguide-coupled bolometer with a time constant approx. 10(exp -3) to 10(exp -5) S at T approx. = 0.1 - 0.3 K will exhibit photon-noise limited performance in millimeter and subn-millimeter range. The bolometer will have a figure-of-merit NEk square root of tau approx. = 10(exp -22) 10(exp -21) W/Hz at 100 mK which is 10(exp 3) times smaller than that of a state-of-the-art bolometer. This will allow for a tremendous increase in speed which will have a significant impact for observational mapping applications. Alternatively, the bolometer could operate at higher temperature with still superior sensitivity This research was performed by the Center for Space Microelectronics Technology, JPL, California Institute of Technology, under the contract for NASA.

Karasik, B. S.↗

Advanced Shipboard Communications Demonstrations with ACTS

For ships at sea. satellites provide the only option for high data rate (HDR), long haul communications. Furthermore the demand for HDR satellite communications (SATCOM) for military and commercial ships. and other offshore platforms is increasing. Presently the bulk of this maritime HDR SATCOM connectivity is provided via C-band and X-band. However, the shipboard antenna sizes required to achieve a data rate of, say T 1 (1.544 Mbps) with present C-/X-band SATCOM systems range from seven to ten feet in diameter. This limits the classes of ships to which HDR services can be provided to those which are large enough to accommodate the massive antennas. With its high powered K/Ka-band spot beams, the National Aeronautics and Space Administration's (NASA) Advanced Communications Technology Satellite (ACTS) was able to provide T I and higher rate services to ships at sea using much smaller shipboard antennas. This paper discusses three shipboard HDR SATCOM demonstrations that were conducted with ACTS between 1996 and 1998. The first demonstration involved a 2 Mbps link provided to the seismic survey ship MN Geco Diamond equipped with a 16-inch wide, 4.5-inch tall, mechanically steered slotted waveguide array antenna developed by the Jet Propulsion Laboratory. In this February 1996 demonstration ACTS allowed supercomputers ashore to process Geco Diamond's voluminous oceanographic seismic data in near real time. This capability allowed the ship to adjust its search parameters on a daily basis based on feedback from the processed data, thereby greatly increasing survey efficiency. The second demonstration was conducted on the US Navy cruiser USS Princeton (CG 59) with the same antenna used on Geco Diamond. Princeton conducted a six-month (January-July 1997) Western Hemisphere solo deployment during which time T1 connectivity via ACTS provided the ship with a range of valuable tools for operational, administrative and quality-of-life tasks. In one instance, video teleconferencing (VTC) via ACTS allowed the ship to provide life-saving emergency medical aid, assisted by specialists ashore. to a fellow mariner - the Master of a Greek cargo ship. The third demonstration set what is believed to be the all-time SATCOM data rate record to a ship at sea, 45 Mbps in October 1998. This Lake Michigan (Chicago area) demonstration employed one of ACTS' fixed beams and involved the smallest of the three vessels, the 45-foot Bayliner M/V Entropy equipped with a modified commercial-off-the-shelf one-meter antenna. A variety of multi-media services were provided to Entropy through a stressing range of sea states. These three demonstrations provided a preview of the capabilities that could be provided to future mariners on a more routine basis when K/Ka-band SATCOM systems are widely deployed.

Axford, Roy A.↗

Endothelium Preserving Microwave Treatment for Atherosclerois

Method and apparatus are provided to treat atherosclerosis wherein the artery is partially closed by dilating the artery while preserving the vital and sensitive endothelial layer thereof. Microwave energy having a frequency from 3 GHz to 300 GHz is propagated into the arterial wall to produce a desired temperature profile therein at tissue depths sufficient for thermally necrosing connective tissue and softening fatty and waxy plaque while limiting heating of surrounding tissues including the endothelial layer and/or other healthy tissue, organs, and blood. The heating period for raising the temperature a potentially desired amount about 20 C, with the atherosclerotic lesion may be less than about one second. In one embodiment of the invention, a radically beveled waveguide antenna is used to deliver microwave energy at frequencies from 25 GHz or 30 GHz to about 300 GHz and is focused towards a particular radical sector of the artery. Because the atherosclerotic lesions are often asymmetrically disposed, directable or focussed heating preserves healthy sectors of the artery and applies energy to the asymmetrically positioned lesion faster than a non-directed beam. A computer simulation predicts isothermic temperature profiles for the given conditions and may be used in selecting power, pulse duration, beam width, and frequency of operation to maximize energy deposition and control heat rise within the atherosclerotic lesion without harming healthy tissues or the sensitive endothelium cells.

Carl, James R.↗

Endothelium Preserving Microwave Treatment for Atherosclerosis

Method and apparatus are provided to treat atherosclerosis wherein the artery is partially closed by dilating the artery while preserving the vital and sensitive endothelial layer thereof. Microwave energy having a frequency from 3 GHz to 300 GHz is propagated into the arterial wall to produce a desired temperature profile therein at tissue depths sufficient for thermally necrosing connective tissue and softening fatty and waxy plaque while limiting heating of surrounding tissues including the endothelial layer and/or other healthy tissue, organs, and blood. The heating period for raising the temperature a potentially desired amount, about 20 C. within the atherosclerotic lesion may be less than about one second. In one embodiment of the invention, a radically beveled waveguide antenna is used to deliver microwave energy at frequencies from 25 GHz or 30 GHz to about 300 GHz and is focused towards a particular radial sector of the artery. Because the atherosclerotic lesions are often asymmetrically disposed directable or focussed heating preserves healthy sectors of the artery and applies energy to the asymmetrically positioned lesion faster than a non-directed beam. A computer simulation predicts isothermic temperature profiles for the given conditions and may be used in selecting power, pulse duration, beam width, and frequency of operation to maximize energy deposition and control heat rise within the atherosclerotic lesion without harming healthy tissues or the sensitive endothelium cells.

Carl, James R.↗