Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “waveform analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Uncertainty Estimates for Sonic-Boom Pressure Signatures and Loudness Carpets

A non-intrusive uncertainty quantification method is applied to computational analysis of supersonic, low-boom aircraft. The mean and standard deviation statistics of the pressure waveforms and loudness metrics are evaluated through use of numerical quadrature. The probability density function (p.d.f.) of these outputs is evaluated via kernel density estimation. The simulations use an inviscid, embedded-boundary Cartesian-mesh flow solver in the nearfield combined with an augmented Burgers’ equation solver for propagation in the farfield. The results show that the p.d.f. of the waveform is bimodal at shocks, which makes the mean and standard deviation statistics inappropriate. Despite this limitation, we show that the moment statistics can provide effective assessment of discrepancies when comparing with experimental data. This is demonstrated by presenting uncertainty analysis of a wind-tunnel test and showing that we significantly improve the predictions when we include the test uncertainties in the simulation. Normal distributions are obtained for the ground signature and loudness metrics, which is primarily due to the careful shaping of the low-boom waveform. Separation of variables and error control are used to reduce computational cost. We demonstrate that this is an efficient approach in the sense of balancing numerical errors in the statistics quadrature with discretization errors in the solvers.

ARMD↗

Influence of modulation frequency in rubidium cell frequency standards

The error signal which is used to control the frequency of the quartz crystal oscillator of a passive rubidium cell frequency standard is considered. The value of the slope of this signal, for an interrogation frequency close to the atomic transition frequency is calculated and measured for various phase (or frequency) modulation waveforms, and for several values of the modulation frequency. A theoretical analysis is made using a model which applies to a system in which the optical pumping rate, the relaxation rates and the RF field are homogeneous. Results are given for sine-wave phase modulation, square-wave frequency modulation and square-wave phase modulation. The influence of the modulation frequency on the slope of the error signal is specified. It is shown that the modulation frequency can be chosen as large as twice the non-saturated full-width at half-maximum without a drastic loss of the sensitivity to an offset of the interrogation frequency from center line, provided that the power saturation factor and the amplitude of modulation are properly adjusted.

Audoin, C.↗

Advanced Electrocardiography Can Identify Occult Cardiomyopathy in Doberman Pinschers

Recently, multiple advanced resting electrocardiographic (A-ECG) techniques have improved the diagnostic value of short-duration ECG in detection of dilated cardiomyopathy (DCM) in humans. This study investigated whether 12-lead A-ECG recordings could accurately identify the occult phase of DCM in dogs. Short-duration (3-5 min) high-fidelity 12-lead ECG recordings were obtained from 31 privately-owned, clinically healthy Doberman Pinschers (5.4 +/- 1.7 years, 11/20 males/females). Dogs were divided into 2 groups: 1) 19 healthy dogs with normal echocardiographic M-mode measurements: left ventricular internal diameter in diastole (LVIDd . 47mm) and in systole (LVIDs . 38mm) and normal 24-hour ECG recordings (<50 ventricular premature complexes, VPCs); and 2) 12 dogs with occult DCM: 11/12 dogs had increased M-mode measurements (LVIDd . 49mm and/or LVIDs . 40mm) and 5/11 dogs had also >100 VPCs/24h; 1/12 dogs had only abnormal 24-hour ECG recordings (>100 VPCs/24h). ECG recordings were evaluated via custom software programs to calculate multiple parameters of high-frequency (HF) QRS ECG, heart rate variability, QT variability, waveform complexity and 3-D ECG. Student's t-tests determined 19 ECG parameters that were significantly different (P < 0.05) between groups. Principal component factor analysis identified a 5-factor model with 81.4% explained variance. QRS dipolar and non-dipolar voltages, Cornell voltage criteria and QRS waveform residuum were increased significantly (P < 0.05), whereas mean HF QRS amplitude was decreased significantly (P < 0.05) in dogs with occult DCM. For the 5 selected parameters the prediction of occult DCM was performed using a binary logistic regression model with Chi-square tested significance (P < 0.01). ROC analyses showed that the five selected ECG parameters could identify occult ECG with sensitivity 89% and specificity 83%. Results suggest that 12-lead A-ECG might improve diagnostic value of short-duration ECG in earlier detection of canine DCM as five selected ECG parameters can with reasonable accuracy identify occult DCM in Doberman Pinschers. Future extensive clinical studies need to clarify if 12-lead A-ECG could be useful as an additional screening test for canine DCM.

Spiljak, M.↗

Induced shock pulse testing by transient waveform control

A method of synthesizing an arbitrarily shaped transient time pulse on vibration exciters is described. The transient waveform control technique is based on recent developments in digital time series analysis, the real-time FFT processor. A brief description of the theory, error estimates and hardware/software implementation to the JPL Dynamic Environmental Testing Laboratory is presented.

Kim, B. K.↗

Parameter Estimation for Compact Binary Coalescence Signals with the First Generation Gravitational-Wave Detector Network

Compact binary systems with neutron stars or black holes are one of the most promising sources for ground-based gravitational-wave detectors. Gravitational radiation encodes rich information about source physics; thus parameter estimation and model selection are crucial analysis steps for any detection candidate events. Detailed models of the anticipated waveforms enable inference on several parameters, such as component masses, spins, sky location and distance, that are essential for new astrophysical studies of these sources. However, accurate measurements of these parameters and discrimination of models describing the underlying physics are complicated by artifacts in the data, uncertainties in the waveform models and in the calibration of the detectors. Here we report such measurements on a selection of simulated signals added either in hardware or software to the data collected by the two LIGO instruments and the Virgo detector during their most recent joint science run, including a blind injection where the signal was not initially revealed to the collaboration. We exemplify the ability to extract information about the source physics on signals that cover the neutron-star and black-hole binary parameter space over the component mass range 1M25M and the full range of spin parameters. The cases reported in this study provide a snapshot of the status of parameter estimation in preparation for the operation of advanced detectors.

Aasi, J.↗

Analysis of GEOS-3 altimeter data and extraction of ocean wave height and dominant wavelength

When the amplitude and timing biases are removed from the GEOS-3 Sample and Hold (S&H) gates, the mean return waveforms can be excellently fitted with a theoretical template which represents the convolution of: (1) the radar point target response; (2) the range noise (jitter) in the altimeter tracking loop; (3) the sea surface height distribution; and (4) the antenna pattern as a function of the range to mean sea level. Several techniques of varying complexity to remove the effect of the tracking loop jitter in computing the wave height are considered. They include: (1) realigning the S&H gates to their actual positions with respect to mean sea level before averaging; (2) using the observed standard deviation on the altitude measurement to remove the integrated effect of the tracking loop jitter, and (3) using a look-up table to correct for the expected value of range noise. Analysis of skewness in the GEOS return waveform demonstrates the potential of a satellite radar altimeter to determine the dominant wavelength of ocean waves.

Walsh, E. J.↗

The effect of transponder imperfections on the error probability performance of a satellite communication system

The bit error rate (BER) performance analysis of a data communication system is generally based on the assumption that signal waveforms are ideal and hardware-induced distortion is absent. In a satellite communication system such distortion arises in the satellite transponder, as well as in the transmitter and receiver portions. NASA, which is in the process of developing its Tracking and Data Relay Satellite System (TDRSS), is very much interested in understanding the impact of numerous forms of hardware distortion that have been identified on BER performance. The present paper examines the cumulative impact of nine forms of distortion induced by the transponder on BPSK and QPSK signals. For the present analysis, the transmitter and receiver are assumed to operate in essentially ideal fashions. Computed results indicate that BPSK and QPSK performances are affected in substantially different manners, with QPSK generally more sensitive to a given form of distortion. Cumulative distortion effects are illustrated via computed performance curves.

Weinberg, A.↗

High Resolution ECG for Evaluation of Heart Function During Exposure to Subacute Hypobaric Hypoxia

High altitude climbing presents a wide spectrum of health risks, including exposure to hypobaric hypoxia. Risks are also typically exacerbated by the difficulty in appropriately monitoring for early signs of organ dysfunction in remote areas. We investigated whether high resolution advanced ECG analysis might be helpful as a non-invasive and easy-to-use tool (e.g., instead of Doppler echocardiography) for evaluating early signs of heart overload in hypobaric hypoxia. Nine non-acclimatized healthy trained alpine rescuers (age 43.7 plus or minus 7.3 years) climbed in four days to the altitude of 4,200 m on Mount Ararat. Five-minute high-resolution 12-lead electrocardiograms (ECGs) were recorded (Cardiosoft) in each subject at rest in the supine position on different days but at the same time of day at four different altitudes: 400 m (reference altitude), 1,700 m, 3,200 m and 4,200 m. Changes in conventional and advanced resting ECG parameters, including in beat-to-beat QT and RR variability, waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG was estimated by calculation of the regression coefficients in independent linear regression models. A p-value of less than 0.05 was adopted as statistically significant. As expected, the RR interval and its variability both decreased with increasing altitude, with trends k = -96 ms/1000 m with p = 0.000 and k = -9 ms/1000 m with p = 0.001, respectively. Significant changes were found in P-wave amplitude, which nearly doubled from the lowest to the highest altitude (k = 41.6 microvolt/1000 m with p = 0.000), and nearly significant changes in P-wave duration (k = 2.9 ms/1000 m with p = 0.059). Changes were less significant or non-significant in other studied parameters including those of waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG. High resolution ECG analysis, particularly of the P wave, shows promise as a tool for monitoring early changes in heart function due to exposure to high altitude.

Zupet, Petra↗

Analysis of satellite altimeter signal characteristics and investigation of sea-truth data requirements

Results are presented of analysis of satellite signal characteristics as influenced by ocean surface roughness and an investigation of sea truth data requirements. The first subject treated is that of postflight waveform reconstruction for the Skylab S-193 radar altimeter. Sea state estimation accuracies are derived based on analytical and hybrid computer simulation techniques. An analysis of near-normal incidence, microwave backscattering from the ocean's surface is accomplished in order to obtain the minimum sea truth data necessary for good agreement between theoretical and experimental scattering results. Sea state bias is examined from the point of view of designing an experiment which will lead to a resolution of the problem. A discussion is given of some deficiencies which were found in the theory underlying the Stilwell technique for spectral measurements.

Source record↗

General purpose algorithms for characterization of slow and fast phase nystagmus

In the overall aim for a better understanding of the vestibular and optokinetic systems and their roles in space motion sickness, the eye movement responses to various dynamic stimuli are measured. The vestibulo-ocular reflex (VOR) and the optokinetic response, as the eye movement responses are known, consist of slow phase and fast phase nystagmus. The specific objective is to develop software programs necessary to characterize the vestibulo-ocular and optokinetic responses by distinguishing between the two phases of nystagmus. The overall program is to handle large volumes of highly variable data with minimum operator interaction. The programs include digital filters, differentiation, identification of fast phases, and reconstruction of the slow phase with a least squares fit such that sinusoidal or psuedorandom data may be processed with accurate results. The resultant waveform, slow phase velocity eye movements, serves as input data to the spectral analysis programs previously developed for NASA to analyze nystagmus responses to pseudorandom angular velocity inputs.

Lessard, Charles S.↗

Ranging performance of satellite laser altimeters

Topographic mapping of the earth, moon and planets can be accomplished with high resolution and accuracy using satellite laser altimeters. These systems employ nanosecond laser pulses and microradian beam divergences to achieve submeter vertical range resolution from orbital altitudes of several hundred kilometers. Here, we develop detailed expressions for the range and pulse width measurement accuracies and use the results to evaluate the ranging performances of several satellite laser altimeters currently under development by NASA for launch during the next decade. Our analysis includes the effects of the target surface characteristics, spacecraft pointing jitter and waveform digitizer characteristics. The results show that ranging accuracy is critically dependent on the pointing accuracy and stability of the altimeter especially over high relief terrain where surface slopes are large. At typical orbital altitudes of several hundred kilometers, single-shot accuracies of a few centimeters can be achieved only when the pointing jitter is on the order of 10 mu rad or less.

Gardner, Chester S.↗

Ranging performance of satellite laser altimeters

Detailed expressions for the range and pulse width measurement accuracies are developed and used to evaluate the ranging performances of several satellite laser altimeters currently under development by NASA for launch during the next decade. The analysis includes the effects of the target surface characteristics, spacecraft pointing jitter, and waveform digitizer characteristics. The results show that ranging accuracy is critically dependent on the pointing accuracy and stability of the altimeter especially over high relief terrain where surface slopes are large. At typical orbital altitudes of several hundred kilometers, single-shot accuracies of a few centimeters can be achieved only when the pointing jitter is on the order of 10 microrad or less.

Gardner, Chester S.↗

Waveform Freezing of Sonic Booms Revisited

Nonlinear distortion of sonic booms propagating in the atmosphere is strongly affected by stratification and geometrical spreading. For a downward propagating sonic boom in a standard atmosphere, stratification and spreading cause a slowing down of nonlinear distortion. In certain cases a stage is reached where no further distortion takes place. When this happens, the waveform is said to be frozen. In previous work the authors argued that for most HSCT designs and flight conditions being considered, the sonic boom is not frozen when it reaches the ground. The criterion used was the value of the distortion distance x bar is a measure of the nonlinear distortion suffered by the wave (and is closely related to Hayes's E variable). The aircraft must be at an altitude greater than 27 km (80,000 ft) for x bar at the groun be within 95% of its asymptotic value. However, work reported here demonstrates that the ground waveform is much closer to the frozen state than indicated by the previous analysis. In the new analysis, duration of the sonic boom is used as the criterion for judging closeness of approach tz frozen state. In order for the duration of the sonic boom at the ground to be within 95% of its frozen value, the flight altitude of the aircraft needs to be only 15 km (45,000 ft).

Cleveland, Robin O.↗

The making of an Alfvenic fluctuation: The resolution of a second-order analysis

Ulysses observations of the high speed polar streams show that they are largely occupied by very large amplitude Alfvenic fluctuations accompanied by many rotational discontinuities. These fluctuations have a nearly constant magnetic intensity or amplitude, and the magnetic field direction per wave cycle sweeps only through a limited arc, much as a car wiperblade would do. Barnes and Hollweg (JGR, 79, 2302, 1974) suggested that this unusual waveform could arise from an obliquely propagating and linearly polarized Alfven wave of finite amplitude. From a second-order analysis, they showed that the existence of a particular solution with a constant amplitude but could not resolve the outcome of the homogeneous solution which consisted of fast waves. They suggested that Landau damping of these fast waves may be needed to get the observed waveform. We present a 1 1/2 D hybrid simulation which is fully nonlinear and correctly describes the ion kinetics for an initially monochromatic and linearly polarized Alfven wave propagating obliquely to the background magnetic field. The wave has a large amplitude and a wavelength so long that it can be considered dispersionless for simulation times. At early times, the second harmonic in density and in magnetic field transverse to the initial wave magnetic field are generated and have more power than other harmonics. Steepening is observed with a weak fast shock emerging, but no rotational discontinuity is left behind, and instead a constant amplitude and an arc-shaped waveform is made. The compressional component which develops after the shocks have dissipated is to zeroth order better described as a pure acoustic wave than as a fast wave. This might be explained by the relaxing of the Alfven wave to a state where its ponderomotive force vanishes so that the compressional component can travel almost independently of it.

Vasquez, Bernard J.↗

Interpretation of Vector Electric Field Measurements of Bursty Langmuir Waves in the Cusp

An analysis of auroral Langmuir waves in the cusp observed by two high-frequency electric field instruments on the TRICE high-flyer sounding rocket shows many examples of Langmuir wave bursts modulated at approximately 10 kHz. Previous studies have explained these and similar observations as the result of beating between waves with very close frequencies near the Langmuir cutoff, resulting from either wave-wave interactions or independent linear excitations. The unique three-dimensional (3-D) data set provided by the NASA Goddard Space Flight Center TAEFWD instrument shows that up to 25% of waveforms selected from the most intense bursts exhibit anisotropic modulations, i.e., the beat nulls and peaks are not aligned in time across the three perpendicular electric field components. Modulations of this type arise when superposed wave normal modes possess differing polarizations, and simulations using wave modes calculated with the J-WHAMP numerical dispersion code show (1) that waves with differing polarizations can exist in conditions like those observed by TRICE-High and (2) that superpositions of such waves can produce anisotropic modulation. Fourier analysis of the 3-D waveform data suggests that both linear and elliptically polarized waves are present near the Langmuir cutoff at these times. These observations illustrate how 3-D measurements can give valuable insight into the nature of wave interactions in the auroral plasma environment.

Dombrowski, M. P.↗

Gravitational Waves from Black Hole Mergers

The final merger of two black holes is expected to be the strongest gravitational wave source for ground-based interferometers such as LIGO, VIRGO, and GEO600, as well as the space-based interferometer LISA. Observing these sources with gravitational wave detectors requires that we know the radiation waveforms they emit. Since these mergers take place in regions of extreme gravity, we need to solve Einstein's equations of general relativity on a computer in order to calculate these waveforms. For more than 30 years, scientists have tried to compute black hole mergers using the methods of numerical relativity. The resulting computer codes have been plagued by instabilities, causing them to crash well before the black holes in the binary could complete even a single orbit. Within the past few years, however, this situation has changed dramatically, with a series of remarkable breakthroughs. This talk will focus on new simulations that are revealing the dynamics and waveforms of binary black hole mergers, and their applications in gravitational wave detection, data analysis, and astrophysics.

Centrella, Joan↗

Binary Black Holes, Gravitational Waves, and Numerical Relativity

The final merger of two black holes is expected to be the strongest gravitational wave source for ground-based interferometers such as LIGO, VIRGO, and GE0600, as well as the space-based interferometer LISA. Observing these sources with gravitational wave detectors requires that we know the radiation waveforms they emit. Since these mergers take place in regions of extreme gravity, we need to solve Einstein's equations of general relativity on a computer in order to calculate these waveforms. For more than 30 years, scientists have tried to compute black hole mergers using the methods of numerical relativity. The resulting computer codes have been plagued by instabilities, causing them to crash well before the black holes in the binary could complete even a single orbit. Within the past few years, however, this situation has changed dramatically, with a series of remarkable breakthroughs. This talk will focus on new simulations that are revealing the dynamics and waveforms of binary black hole mergers, and their applications in gravitational wave detection, data analysis, and astrophysics.

Centrella, John↗

The Resource Prospector Neutron Spectrometer System: RP's Bloodhound

The primary goal of the Resource Prospector Neutron Spectrometer System (NSS) is to locate and characterize hydrogen-bearing volatile deposits, especially subsurface ice, that may exist at the lunar poles. A key objective is to detect water-equivalent hydrogen concentrations of 0.5 wt% or greater while on a moving rover. A second objective is to determine approximate burial depth of enhanced hydrogen-bearing materials up to 1 meter below otherwise dry regolith. The instrument will be carried aboard a landed mobility system at the lunar poles. The instrument operates by measuring the changes in the leakage flux of low energy neutrons out of the regolith. These neutrons are produced by galactic cosmic rays, which are so energetic that they shatter the nuclei in surface materials. The neutrons interact with other nuclei and lose energy, becoming thermalized in the process. Hydrogen is most efficient at thermalizing neutrons owing to protons' similar mass - statistically, neutrons lose half their energy per collision with protons. With hydrogen in the soil, leakage fluxes of neutrons in the 0.5 eV to 500 keV energy range are reduced. A concentration of only1-2 wt% water-equivalent hydrogen results in a decrease in epithermal leakage flux of a factor of two. The leakage flux of thermal neutrons, from 0 to 0.5 eV in energy, can either increase or decrease depending on the hydrogen abundance and stratigraphy. As with the highly successful Lunar Prospector Neutron Spectrometer, the RP NSS detects both thermal and epithermal neutrons by using two helium-3 gas proportional counters, one covered by cadmium and the other uncovered. The former detects only epithermal neutrons with energies above approximately 0.5 eV, the latter detects both thermal (less than 0.5 eV) and epithermal energies (greater than 0.5 eV). When a neutron enters the detector tube and interacts with a helium-3 nucleus, the resulting reaction produces an energetic proton and triton that ionize the gas. The resulting electrons are accelerated toward a high-voltage anode and cascade, amplifying the net charge, which is collected at the anode. The number of electrons produced is proportional to the energy that the triton and proton deposit in the gas. A charge sensitive pre-amplifier converts the total charge to a step voltage output. A shaper amplifier then shapes this step into a uni-polar waveform with peaking time appropriate for the detection depending on the event rate. The integrated shaped waveform, representing the deposited triton/proton energy, is then measured. A histogram, or pulse height analysis, is performed to record the main capture peak and wall effect pulses. A threshold for detection is also required to limit the low amplitude counting rate such as noise floor. The system electronics consists of 2 modules - the Sensor Module (SM) front-end and the Data Processing Module (DPM) back-end circuits. SM is designed as a light-weight and low power front-end housing the two helium-3 proportional counter detectors, preamp and HVPS. It is mounted external to the rover body to detect the thermalized neutron flux with a minimum of host background. The DPM is located inside the rover; it digitizes the SM signals, performs pulse height analysis and accumulates the count rate for each spectral channel. The DPM controls high voltage and thresholding, and sends the science data to the host craft via an RS422 serial asynchronous protocol. The payload host provides all thermal management and control for the SM and DPM.

hydrogen-bearing volatile deposits↗