Seamless Transition of Critical Infrastructures using Droop Controlled Grid-forming Inverters

Seamless recovery of power to critical infrastructures, after grid failure, is a crucial need arising in scenarios that are increasingly becoming more frequent. Here, this article proposes a seamless transition strategy using a single and unified mode-dependent droop controlled grid-forming inverters. The control strategy achieves the following objectives: 1) regulates the output active and reactive power by the droop-controlled inverters to a desired value while operating in on-grid mode; 2) seamless transition and recovery of power injections into the load after grid failure by inverters that operates in grid-forming mode all the time; 3) requires only a single bit of information on the grid/network status for the mode transition. A framework for assessing the stability of the system and to guide the choice of parameters for controllers is developed using control-oriented modeling. A controller hardware-in-the-loop-based real-time simulation study on a test system based on the realistic electrical network of a commercial-scale medical center is conducted for initial prototyping of the control strategy. A hardware experiment is conducted with two 3 - $\phi$, 480 -V, 125 -kVA grid-forming inverters, a 3 - $\phi$, 480 -V, 270 -kVA grid simulator, a physical grid switch, and a physical load bank. The experimental data establishes the effectiveness of the always grid-forming operation and control of inverters in meeting power delivery objectives when on-grid and off-grid under various kinds of loads and scenarios while minimizing transients during transitions. Furthermore, performance comparison with existing strategies showcases the advantage of the proposed strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Current Observer Based Predictive Decoupled Power Control Grid-Interactive Inverter

This paper presents a sensor-less current model predictive control (MPC) scheme via a full state observer based current estimator. The grid interactive inverters’ control schemes require current and voltage sensors. Elimination of current sensor enhances the inverter reliability. This paper leverages the inherent characteristics of MPC towards robust current sensor-less grid interactive inverter with LC filter. The observer for inductor current is developed based on the existing capacitor voltage measurement. The estimator dynamic state-space matrices are then obtained through reconstruction of the inverter model with the capacitor voltage and inductor current being the state variables. The controller objectives are to regulate active and reactive power in a decoupled manner. The theoretical expectation, controller performance, and accuracy of the current estimation are verified by conducting a real-time simulation via Typhoon HIL.

Zhang, Zhen↗

Detection of visible-wavelength aurora on Mars

Mars hosts various auroral processes despite the planet’s tenuous atmosphere and lack of a global magnetic field. To date, all aurora observations have been at ultraviolet wavelengths from orbit. We describe the discovery of green visible-wavelength aurora, originating from the atomic oxygen line at 557.7 nanometers, detected with the SuperCam and Mastcam-Z instruments on the Mars 2020 Perseverance rover. Near–real-time simulations of a Mars-directed coronal mass ejection (CME) provided sufficient lead-time to schedule an observation with the rover. The emission was observed 3 days after the CME eruption, suggesting that the aurora was induced by particles accelerated by the moving shock front. To our knowledge, detection of aurora from a planetary surface other than Earth has never been reported, nor has visible aurora been observed at Mars. This detection demonstrates that auroral forecasting at Mars is possible, and that during events with higher particle precipitation, or under less dusty atmospheric conditions, aurorae will be visible to future astronauts.

Science & Technology - Other Topics↗

Bulb-style Kaplan Turbine - Run-of-the-river (ror) Hydro Governor And Turbine Model

This software package includes hydro governor and turbine models developed in Simulink (Mathworks Inc.) and RSCAD (RTDS Technologies) for low-head bulb-style Kaplan turbine hydropower plants. The model developed in Simulink has been designed and tuned to match the governor-turbine response for a real-world hydropower unit owned by Idaho Falls Power (IFP). The Simulink and RSCAD models enable real-time testing in a hardware-in-the-loop (HIL) implementation using OPAL-RT and RTDS digital real-time simulators, respectively. An automatic initialization for dynamic simulation has also been integrated to each model in both Simulink and RSCAD. The RSCAD initialization involves a novel python-based interfacing for automatic modification of the initial conditions in the model. The parameters of these models can be tuned to match other hydropower plants in this class.

Alam, SMShafiul↗

On the novel 3-D neutron transport kinetic tRAPID algorithm and its validation

The Real-time Analysis for Particle-transport and In-situ Detection (RAPID) Code System, based on the Multi-stage Response-function Transport (MRT) methodology, allows for real-time simulation of nuclear systems based on 3-D continuous-energy particle transport. RAPID's steady-state (criticality) neutron transport algorithm is based on the Fission Matrix (FM) method, and has been extensively verified and validated against computational benchmarks and experiments. This paper introduces the novel 3-D time-dependent transport algorithm that has been implemented into the code, tRAPID, and its validation using the JSI TRIGA Mark-II reactor. tRAPID accurately and efficiently calculates neutron kinetics parameters (such as β{sub eff}, l{sub eff} , Λ, α{sub Rossi}) and 3-D time-dependent neutron fission source distribution and neutron importances for both prompt and delayed neutrons. tRAPID is used to simulate a rod insertion experiment performed at the JSI TRIGA Mark-II reactor, during which signals from four fission chambers at four different locations in the core were collected. The results demonstrate how tRAPID is capable of calculating detailed and accurate results with only a minimal use computational resources and time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cooperative Research and Development Agreement among National Energy Technology Laboratory, The Board of Regents of the University System of Georgia by and on behalf of Georgia Institute of Technology, and University of Texas at El Paso [Abstract]

Georgia Institute of Technology (GIT), University of Texas at El Paso (UTEP), and the National Energy Technology Laboratory (NETL) will collaborate and develop cyber-physical systems for advanced power systems. GIT will test virtual models on hybrid power system hardware and cyber physical components. UTEP will test novel actuators on hybrid power system hardware. NETL will access GIT’s expertise in the engineering and real time simulation of power system processes for cyber-physical systems and simulations to control hardware. NETL will establish a relationship to promote UTEP’s capabilities in additive manufacturing and high-temperature piezo-electric devices with the potential for controlling high-temperature flows with a light and inexpensive device at high response rates. This project is the result of an EERE Advanced Manufacturing Office open Multi-Topic awarded proposal led by GIT titled, “Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration”.

42 ENGINEERING↗

Hardware-in-the-loop Testing of Network Protectors for Low-Voltage Networks with Distributed Energy Resources

In this report, we developed and validated a network protector relay digital twin model and interfaced a commonly used network protector relay hardware with our real-time simulation system. Hardware-in-the-loop protection studies are performed to assess the impact of distributed energy resources (DER) and benchmark a rate-of-change-based mitigation strategy. Simulation results suggest that the network protector reverse trip and auto-reclose functions are negatively impacted by the high distributed energy resource penetration. To accommodate DER backfeed while remaining secure and reliable for faults on primary feeders, we recommend options for a rate-of-change-based blocking scheme and a protection setting change. Finally, future mitigation ideas and standard revisions are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital Grid Twin–Direct Communication Scheme Test Bed for Assessing Relay-to-Relay Radio Antenna and Optical Fiber Performance and Misoperations

This study introduces a novel “Digital Grid Twin–Direct Communication Scheme” test bed. This advanced platform evaluates point-to-point communication between transmitter and receiver relays with optical fiber and radio omnidirectional antenna systems, implemented at the Advanced Protection lab in the Grid Research Innovation and Development Center at Oak Ridge National Laboratory. The increased diversity of energy sources has led to more protective relay misoperations. In North America, microgrid protection schemes now use point-to-point communication along distribution lines between relays to implement advanced logic in nonradial grids that include both high- and low-inertia generators. This trend challenges utilities to minimize misoperations while ensuring rapid fault clearance and accurate selectivity coordination between primary and backup relays. This study assesses relay-to-relay communication schemes by introducing an advanced testing platform based on a digital grid twin protection test bed using a synchronized time source system. The platform evaluates the communication system using radio antennas or optical fiber links by integrating protective relays that operate breakers within the digital twin and record relay events and communication signals. In the experiments, transmitter and receiver relays were configured with inverse time overcurrent and breaker trip detection logic to assess the total time of the communication protection schemes based on the sum of the relay protection element operating time, radio latency, propagation delay, baud rate delay, and relay processing time. These delays were derived from recorded relay events and communication signals from the interface of a real-time simulator set as a digital grid twin. The test bed successfully simulated various electrical faults along a distribution line while ensuring effective and reliable point-to-point communication between transmitter and receiver relays. The radio antenna communication system exhibited latency because of the radio. This latency depends on the baud rate setting and type of radio application; in general, the higher the baud rate, the lower the radio latency. The measured radio latency (for Mirrored Bits with an encryption card at 9,600 bps) was about 9–10 ms. Additionally, calculated propagation delay per mile for radio antennas and optical fiber was 5.36 µs/mi and 8.04 µs/mi, respectively. Optical fiber communication did not demonstrate radio latency. Instead, the protection element operating time depends mainly on the protection logic function set in the relay, and the relay processing time depends on the processing rate of the relay in samples per power system cycle.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparative and Cost Analysis of a Novel Predictive Power Ramp Rate Control Method: A Case Study in a PV Power Plant in Puerto Rico

One of the most important aspects that need to be addressed to increase solar energy penetration is the power ramp-rate control. In weak grids such as the one found in Puerto Rico, it is important to smooth power fluctuations caused by the intermittence of passing clouds. In this work, a novel power ramp-rate control strategy is proposed. Additionally, a comparison with some of the most common power ramp-rate control methods is performed using a proposed model and real solar radiation data from the Coto Laurel photovoltaic power plant located in Ponce, Puerto Rico. The proposed model was validated using one-year real data from Coto Laurel. The power ramp-rate control methods were compared in real-time simulations using the OP5700 from Opal-RT Technologies considering power ramp rate fluctuations, power ramp-rate violations, fluctuations in the state-of-charge, among other indicators. Moreover, the proposed power ramp-rate control strategy, called predictive dynamic smoothing was explained and compared. Results indicate that the predictive dynamic smoothing produced a considerably reduced Levelized Cost of Storage compared to other power ramp-rate control methods and provided a higher lifetime expectancy for lithium batteries.

36 MATERIALS SCIENCE↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Advanced Synchronized Time Digital Grid Twin Testbed for Relay Misoperation Analysis of Electrical Fault Type Detection Algorithms

Distributed energy resources and the number of relays are expected to rise in modern electrical grids; consequently, relay misoperations are also expected to grow. Relays can detect electrical fault types using an internal algorithm and can display the result using light indicators on the front of the relay. However, some relays’ internal algorithms for predicting types of electrical faults could be improved. This study assesses a relay’s external and internal algorithms with an Advanced Synchronized Time Digital Grid Twin (ASTDGT) testbed with paired relays. A misoperation relay analysis focused on measuring the accuracy of using the boundary admittance (the external algorithm) versus the set-default (the internal algorithm) relay method to determine the electrical fault types was performed. In this study, the internal and external relay algorithms were assessed with a synchronized time digital grid twin testbed using a real-time simulator. This testbed evaluated two sets of logic at the same time with the digital grid twin and paired relays in the loop. Different types of electrical faults were simulated, and the relays’ recorded events and electrical fault light indicator states were collected from the human–machine interfaces. This ASTDGT testbed with paired relays successfully evaluated the relay algorithm misoperations. The boundary admittance method had an accuracy of 100% for line-to-line, line-to-ground, and line-to-line ground faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Grid-Forming Inverter Controls for Grid-Connected and Islanded Microgrid Integration

Autonomous grid-forming (GFM) inverter testbeds with scalable platforms have attracted interest recently. In this study, a self-synchronized universal droop controller (SUDC) was adopted, tested, and scaled in a small network and a test feeder using a real-time simulation tool to operate microgrids without synchronous generators. We presented a novel GFM inverter control adoption to better understand the dynamic behavior of the inverters and their scalability, which can impact the distribution system (DS). This paper provides a steady-state and transient analysis of the GFM power inverter controller via simulation to better understand voltage and frequency stabilization and ensure that the critical electric loads are not affected during a prolonged power outage. The controllers of the GFM inverter are simulated in HYPERSIM to examine voltage and frequency fluctuations. This analysis includes assessing the black start capability for photovoltaic microgrids, both grid-connected and islanded, during transient fault conditions. The high photovoltaic PV penetration levels open exciting opportunities and challenges for the DS. The GFM inverter control demonstrated appropriate response times for synchronization, connection, and disconnection to the grid. The DS has become more resilient and independent of fossil fuels by increasing the penetration of inverter-based distributed energy resources (DERs).

Ward, Laura (ORCID:0000000345501581)↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY↗

Electrical Fault and Power Quality Detection Algorithms and Customer-Owned DERs Monitoring with a Cyber Grid Guard System and DLT

In this study, the electrical fault and power quality detection algorithms and customer-owned DERs monitoring use cases were implemented, with a Cyber Grid Guard system and DLT. Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substations, and are associated with customer-owned distributed energy resources (DERs). Data from these IEDs, such as power meters and protection relays, must be kept confidential and of high integrity. Blockchain technology has the potential to increase microgrid resilience by enhancing data sharing security. The growing use of IEDs and customer-owned renewable energy sources (DERs) may make it necessary to connect Distributed Ledger Technology (DLT) with power system applications. We implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in the loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results showed the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, power system applications for the ESGT with DERs and the CGG system will be based on executing smart contracts between electrical utilities and customer-owned DERs.

Piesciorovsky, Emilio↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation: Preprint

Utilities have been installing microgrids due to the advancements in the distributed energy resources technologies. Microgrids also improve the resiliency of the system due to their capability to isolate themselves from the grid and run in islanded mode of operation. Microgrid controllers are management systems that can run the microgrids under varied operating condition and enable the smooth operation of microgrids under various system conditions. It is of high value to de-risk the installation of such controllers. Hardware-in-the-loop evaluation is used by controller developers and utilities to evaluate the controllers under stressful conditions to understand the performance and to understand the necessary improvements to the microgrid controller. In this research work, the team has leveraged the existing infrastructure of real-time simulation at the Energy Systems Integration Facility (ESIF) and the capability of the microgrid controller to control assets over the Internet Protocol (IP) to evaluate a university developed microgrid controller in an efficient and cost-effective manner. The full paper will provide the complete setup, the experimental use cases and the results. In this abstract, one use case will be expalined, and the results from the use case is provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large-Scale Adoption of Self-Synchronized Universal Droop Controller-Based Inverters to Enable Ancillary Services for Different Modes of Distribution System Operations

This work proposes the large-scale adoption of self-synchronized universal droop controller (SUDC)-based inverters to enable ancillary services for different modes of distribution system operations. The IEEE 123 bus system was modeled on a real-time simulator to study the performance of large-scale adoption of SUDC inverters in a distribution system. The resulting data collected shows that the voltage and the frequency were regulated within ranges, such as less than 5% for voltage and less than 0.5% for frequency, under different load variations and grid operations. Also, the black start was achieved within 0.4 s without any voltage overshoot. Through the simulation and validation on a small microgrid and the IEEE 123 bus distribution system, it can be concluded that the SUDC was successfully adopted to regulate the voltage and the frequency within the given ranges, and black start achieved within 1 s without voltage overshoot for different modes of distribution system operations.

14 SOLAR ENERGY↗

Impact of Blockchain Delay on Grid-Tied Solar Inverter Performance: Preprint

This paper investigates the impact of the delay resulting from a blockchain, a promising security measure, for a hierarchical control system of inverters connected to the grid. The blockchain communication network is designed at the secondary control layer for resilience against cyberattacks. To represent the latency in the communication channel, a model is developed based on the complexity of the blockchain framework. Taking this model into account, this work evaluates the plant’s performance subject to communication delays, introduced by the blockchain, among the hierarchical control agents. In addition, this article considers an optimal model-based control strategy that performs the system’s internal control loop. The work shows that the blockchain’s delay size influences the convergence of the power supplied by the inverter to the reference at the point of common coupling. In the results section, real-time simulations on OPAL-RT are performed to test the resilience of two parallel inverters with increasing blockchain complexity.

41 EE - Solar Energy Technologies Office (EE-4S)↗