At least 145 records · Page 8

Investigation of a high-temperature combination heat pump for lower-cost electrification in multifamily buildings

The development of space and water heating combination heat pumps capable of generating water temperatures high enough for convective heat emitters will enable more cost-effective and equitable decarbonization solutions for electrifying multifamily buildings. Here, in this paper, multifamily building models and a charge-sensitive mechanistic cycle model of a combination heat pump are developed, and the system performance is predicted based on the models. Unlike other state-of-the-art residential heat pumping equipment, the modeled combination heat pump using an economized, fluid-injected variable-speed compressor can achieve higher temperature lifts of 40° - 85°C, with lower installation costs and complexity. The model predicted heating coefficient of performance (COP h ) is 2.1 at an ambient temperature of -15°C with a high-temperature lift of nearly 85°C, and a seasonal coefficient of performance in heating mode (SCOP h ) ranges from 2 - 4 for different locations. The system shows 30% - 90% lower CO 2 eq emissions over a condensing gas boiler and 9% - 13% lower projected installation costs than two separate space and water heat pumping appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Design of Vacuum Pumping Systems for the Material Plasma Exposure eXperiment

The Material Plasma Exposure eXperiment (MPEX) vacuum pumping system is responsible for creating prototypic conditions in the plasma material interaction chamber that mimic those in a fusion reactor divertor region. Additionally, the vacuum system needs to minimize the pressure in the plasma heating region to improve the coupling of the electron cyclotron heating and ion cyclotron heating to the plasma, minimizing waste heat exhausted to high heat flux components. Here, the final design of the system has been sized to comply with the vacuum pump operating environment and to reduce the number of unique pumps required while meeting performance requirements. Bounding cases with and without the plasma present have been developed in the pumping analysis, and an initial calculation has been performed based on the plasma pumping identified in Proto-MPEX operation though this result will remain unverified until MPEX operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact Analysis of Transitioning to Heat Pump Rooftop Units for the U.S. Commercial Building Stock: Preprint

20% of the U.S. commercial building sector's energy usage is from on-site combustion of fossil fuels for heating. Decarbonization will require electrification of these systems to meet climate goals, often by transitioning to heat pumps. Rooftop units (RTU) are the most prominent commercial building HVAC system type and should therefore be prioritized for decarbonization solutions. However, there is limited understanding of the impact on emissions that considers regional electricity generation methods, as well as the impact of other heat pump intricacies such as the effects of temperature on capacity/efficiency, defrost operation, realistic sizing methodologies, and supplementary heating. This study explores the effects of transitioning all conventional RTUs to high-performance heat pump RTUs for the U.S. commercial building stock. The analysis is performed using ComStock, DOE's calibrated model of the U.S. commercial building stock developed by NREL. Results show 9% and 17% reductions in stock aggregate energy consumption and GHG emissions, respectively. Furthermore, average heat pump operational details are presented by state. This analysis will help inform the transition to heat pump RTUs for the U.S. commercial building stock.

commercial building electrification↗

Superhydrophobic heat exchangers delay frost formation and enhance efficency of electric vehicle heat pumps

The number of electric vehicles has rapidly expanded as high-performance automotive lithium-ion batteries have become more affordable. However, the range of electric vehicles decreases in cold climates partly because of the additional thermal loads associated with cabin heating. One way to improve the efficiency of cabin heating is to replace resistive heating elements with an air-source heat pump system. However, to gain the full benefit of heat pumping, frost formation on the outdoor heat exchanger must be minimized. In this work, we modified the surface wettability of aluminum louvered-fin automotive heat pump evaporators and tested them under realistic operating conditions in a transcritical carbon dioxide (CO 2 ) heat pump. Each heat exchanger underwent several consecutive frosting and defrosting cycles to understand the cyclic performance of the system. The heat exchanger with a superhydrophobic outer surface was able to delay frost formation and maintain higher heat transfer rates when compared to heat exchangers with higher surface energies (hydrophilic). The delayed frost formation resulted in a system efficiency benefit in the first few frosting cycles but diminished in later cycles due to water retention and incomplete defrosting. However, for most automotive applications the superhydrophobic heat exchanger showed substantial benefits for normal driving trips. We report the scalable and optimized superhydrophobic heat exchangers developed here have the potential to increase the efficiency of automotive heat pumps and consequently increase the range and reduce energy consumption of electric vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced spin pumping in heterostructures of coupled ferrimagnetic garnets

Spin pumping has significant implications for spintronics, providing a mechanism to manipulate and transport spins for information processing. Understanding and harnessing spin currents through spin pumping is critical for the development of efficient spintronic devices. The use of a magnetic insulator with low damping enhances the signal-to-noise ratio in crucial experiments such as spin-torque ferromagnetic resonance (FMR) and spin pumping. A magnetic insulator coupled with a heavy metal or quantum material offers a more straightforward model system, especially when investigating spin-charge interconversion processes to greater accuracy. This simplicity arises from the absence of unwanted effects caused by conduction electrons unlike in ferromagnetic metals. Here, we investigate the spin pumping in coupled ferrimagnetic (FiM) Y 3 Fe 5 O 12 (YIG)/Tm 3 Fe 5 O 12 (TmIG) bilayers combined with heavy-metal (Pt) using the inverse spin Hall effect. It is observed that magnon transmission occurs at both of the FiMs FMR positions. The enhancement of spin pumping voltage (V sp ) in the FiM garnet heterostructures is observed. The plausible reason might be the interfacial exchange coupling between FiMs. The modulation of V sp is achieved by tuning the bilayer structure. Further, the spin mixing conductance for these coupled systems is found to be ≈ 10 18 m –2 . Furthermore, our findings describe a coupled FiM system for the investigation of magnon coupling providing opportunities for magnonic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Compression in Palladium Alloy Metal Foil Pumps

Metal foil pumps (MFPs) are key components in the direct internal recycling inner fuel cycle loop for the recovery of hydrogen isotopes from deuterium-tritium fusion exhaust. Operating under vacuum conditions, they utilize superthermal hydrogen as the feed gas in a process called superpermeation. A notable feature of MFPs is their ability to pump against a pressure gradient. This study examines the compression capabilities of PdAg and PdCu MFPs at low temperatures with a constant feed pressure of 10 Pa. At 75°C, compression ratios exceeding 200 were readily achieved, with downstream pressures exceeding 4500 Pa using PdCu. For both alloys, net fluxes decreased by only ~15% at downstream pressures of 1000 Pa, which offers potential simplifications for the downstream pump train. Performance declined markedly when the temperature was elevated to 200°C. Pump curves were constructed and advocated as the most appropriate manner to assess MFP performance. Separate pressure-driven-permeation experiments at relevant conditions were conducted, providing a direct measurement of the hydrogen dissociation constant $k$ d , which was found to be in good agreement with the previous literature. Further, these measurements were used to predict pump curves and maximum compression ratios by balancing superpermeation with pressure-driven permeation, achieving excellent agreement with experiment. Last, experiments using asymmetric MFPs revealed the detrimental impact that surface impurities have on performance in this system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance Evaluation and Costs of a Combined Ground Source Heat Pump and Solar Photovoltaic Storage System in an Extreme Cold Climate

This report outlines the effectiveness and economics of a ground source heat pump system installed together with solar photovoltaic panels and a battery storage system in a local community building situated in a cold climate. The community building is a tribal building located in Ruby, Alaska. Power from solar photovoltaic panels is supplemented by electricity purchased from the local community microgrid. A ground source heat pump was commissioned three years after the building was occupied, and supplements the heat generated by a boiler for both heat and domestic hot water. Data collected over the 2021-2022 heating season shows that the heat pump is providing heat to the building about 19% of the time with an average coefficient of performance of 2.68, ranging from below 2.5 in winter to above 3.0 in summer. The solar photovoltaic panels provided 4,700 kWh of power used within the building and an additional 2,900 kWh exported to the microgrid. The solar-produced power used within the building nearly offsets the estimated annual electrical draw of the heat pump of 5,700 kWh. Due to the very high costs for shipping and installation to remote locations, projects such as this, while not economically feasible if self-funded, can save the community an estimated $76,051 over a period of 20-years. Fuel prices increasing by more than 25%, or subsidized electricity prices decreasing by more than 25%, make the ground source heat pump a more viable option economically. Unsubsidized electricity prices increasing by 25% or more make a solar photovoltaic system with battery storage nearly economically viable after a 20-year period for commercial or school buildings that are not eligible for Alaska's Power Cost Equalization program.

14 SOLAR ENERGY↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units with Original Fuel Backup

This documentation focuses on a single end-use savings shape measure—heat pump rooftop units with supplemental heat that matches the original fuel type of the replaced system; if the existing system used electric resistance heating, the supplemental heating source is electric resistance. If it was a natural gas furnace, the supplemental system is modeled as natural gas. This is a modification to the heat pump rooftop unit with electric supplemental heat measure from the Commercial EUSS 2023 Release 1 dataset. This document will primarily discuss the supplemental heating change for the heat pump RTU measure. For a comprehensive overview of the fundamental modeling methodology and background of the heat pump RTU measure, including performance curves and other key assumptions, please review the documentation for the original heat pump rooftop unit with electric supplemental heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pumped Thermal Energy Storage Using Low-Cost Particles and a Fluid Bed Heat Exchanger for Maximum Power Efficiency

Robust, efficient, cost-effective long-duration electricity storage (LDES) solutions can enhance grid resiliency, support existing transmission and distribution infrastructure, and enable a greater share of low-cost, variable alternative energy sources to penetrate the market. To meet this need, the project team at the National Renewable Energy Laboratory developed a transformative LDES system based on pumped thermal energy storage (TES) using low-cost particles and a fluid bed heat exchanger for maximum power efficiency (PUMP). The PUMP system is composed of high-temperature, low-cost particle TES coupled with an advanced pressurized fluid bed heat exchanger (PFB HX) that supports a high-efficiency pumped thermal energy storage (PTES) system integrated with concentrating solar thermal power (CSP). The PUMP project developed and de-risked a PFB HX and particle CSP system intended to be integrated with reversible turbomachinery and a modeling tool to assess PTES cost and performance.

14 SOLAR ENERGY↗

Fan and Pump Efficiency in Modelica based on the Euler Number

Simulation programs often assume constant hydraulic efficiency for fan or pump models when performance curves are unavailable. This is inaccurate because the hydraulic efficiency varies with the operation condition. It therefore consistently underestimates the power draw at off-design conditions at which the hydraulic efficiency drops. Use of a modified Euler number allows computing the hydraulic efficiency and shaft power with limited data. Others showed the validity of the modified Euler number for fan efficiency calculations. We show that it is also applicable for pumps, and present its implementation in Modelica for a fan or pump model. Here, the only input required from the user is one data point at which the hydraulic efficiency is at its maximum. The reported method is applicable regardless of the type, size, or operational region of the fan or pump. Across a sample of eighteen sets of pump data and seven sets of fan data, the errors of the computed power from interpolated data were within 15% for the range of 20% - 70% of maximum flow rate and 40% - 90% of maximum pressure rise, excluding outliers.

component model↗

Bacterial Resistance Toward Antimicrobial Ionic Liquids Mediated by Multidrug Efflux Pumps

The effective elimination of foodborne pathogens through cleaning and disinfection measures is of great importance to the food processing industry. As food producers rely heavily on disinfectants to control pathogenic bacteria in their facilities, the increasing spread of tolerant, often even multidrug resistant, strains is of particular concern. In addition to efforts to prevent or at least reduce development and spread of strains resistant to disinfectants and sanitizers, there is an urgent need for new and effective antimicrobials. One new class of promising antimicrobials is ionic liquids (ILs), which have been reported to be effective against resistant strains as they interact with bacterial cells in multiple ways, but investigations of their effectivity against MDR bacteria or specific defense mechanisms are still limited. This study investigates the role of multidrug efflux pumps of the Resistance Nodulation-Division family (RND) on the resistance of bacterial pathogens Escherichia coli and Salmonella enterica serovar Typhimurium toward 10 antimicrobial active ILs. Results reveal that, while known structure–activity relationships (SARs), such as the side-chain effect, were found for all strains, antimicrobial ILs with one elongated alkyl side chain were significantly affected by the RND efflux pump, highlighting the importance of efflux pumps for future IL toxicity studies. In case of antimicrobial ILs with multiple side chains and different cationic head groups, two ILs were identified that were highly active against all investigated strains with little to no effect of the efflux pump. The results obtained in this study for RND efflux pumps can serve as a starting point for identifying and designing antimicrobial ILs as effective biocides against MDR bacteria.

59 BASIC BIOLOGICAL SCIENCES↗

Cold-Climate Packaged Heat Pumps - Resistance is Futile

The U.S. currently has a large market for room/zonal space conditioning equipment focused primarily on cooling, namely packaged terminal air conditioners (PTACs), packaged terminal heat pumps (PTHPs), and room air conditioners. This equipment largely relies on electric resistance for heating, particularly when outdoor temperatures fall to 40°F or below, presenting a compelling opportunity for energy savings and carbon reductions from reverse cycle heating. This paper provides an overview of cold climate packaged heat pump technologies in the market capable of high output down to outdoor temperatures of 5°F and identifies the technological and market barriers to adoption. For state-of-the-art cold climate packaged heat pumps sold in the retrofit market, defrost meltwater management is the principal barrier to implementation. An energy use analysis is conducted on state-of-the-art cold climate packaged heat pumps for heating and cooling loads by building vintage and climate zone. Potential solutions to defrost meltwater are proposed and modeled for their impact on heating energy efficiency. A national impact assessment estimates the aggregate energy savings and carbon reductions if cold climate packaged heat pumps were to replace existing PTACs and PTHPs in the U.S. building stock. A national, two-track approach is proposed for increasing market adoption in the replacement and new construction markets.

ACEEE Summer Study, cold climate, heat pumps, ccph↗

Numerical Investigation of High Delta T Sensible Storage Integrated CO2 Heat Pump: Preprint

To assist building heating electrification, this paper numerically investigates a load flexible heat pump system for commercial buildings. The system consists of a CO2 vapor compression cycle, a sensible thermal storage tank, and an air handling unit. The thermal storage medium is inexpensive, non-toxic and stable anti-freeze solution (30% potassium acetate). The air handing unit has an indoor coil and a ventilation coil. The system can be used to manage building electric load. During peak hours, the heat pump is off and the hot solution water is discharged from the tank to heat up the indoor air and ventilation air. During the hour of charge, the heat pump delivers hot solution water to the tank and to the air. The tank can also stand by while the heat pump provides space heating directly. We selected a medium sized office building located in Minnesota as the representative building and used EnergyPlus to obtain its 24 hour load data. We designed three storage tank volumes assuming 50 degrees C, 65 degrees C and 80 degrees C tank temperatures to independently provide the building load for 4 hours in the morning. The higher the tank temperature, the smaller the required volume, and thus higher energy density. The effective energy density is 78 with an 80 degrees C tank, and 40 kWhth/m3 with 50 degrees C. We simulated the tank integrated heat pump performance subjected to the 24-hour building load profile and ambient data. The baseline is the same system without storage tank. There was a trade-off between the storage energy density and the charging COP. The charge hour COP was 2.77 to charge the tank to 80 degrees C, and 3.01 to 50 degrees C. The proposed system could shift building load from the peak hours (8:00 - 12:00) to off-business hour (23:00 - 7:00+1). It eliminated 100% compressor electricity use during the peak hours, and avoided a peak electric power of 34 kW. The 65 degrees C tank saved 9.5 kWhe (4%) considering all day operation, which was the best balance between energy density and the system operation efficiency among the three options.

CO2 heat pump↗

Model-based predictive control of multi-stage air-source heat pumps integrated with phase change material-embedded ceilings

This paper presents a model-based predictive control strategy to optimize the operations of phase change material (PCM) ceiling panels coupled with a multi-stage air-source heat pump. A three-stage prototype heat pump unit has been built and tested in the laboratory, with the low and medium stages designed for space heating/cooling and the high compression stage dedicated to charging of the PCM energy storage. To facilitate optimal control of the integrated heat pump system, a mixed-integer linear programming formulation is derived through linearization of the heat pump model and a mixed-integer reformulation of the PCM dynamic governing equations. A predictive control strategy is synthesized based on the resultant control formulation and implemented in a receding horizon scheme that optimizes the PCM charging and the zone temperature schedules simultaneously to leverage both the passive (associated with building construction materials) and active (PCM) storage capacities of a building. The control strategy has been tested along with three benchmarking control scenarios using a co-simulation platform for a prototypical detached house in Atlanta, GA. In this study, test results showed that application of the proposed control strategy to the PCM-integrated heat pump could provide 27.1% electricity cost savings while a fine tuned rule-based control strategy could achieve cost savings of 20.4%, compared to a baseline case without PCM storage, under a time-of-use rate tariff.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou↗

Comparative performance assessment of air-source and ground-source heat pumps using CO₂ and R-410A with water well integration: A simulation study

This study investigates the performance and feasibility of heat pump systems for residential space heating in cold climates, with a particular focus on ground source heat pumps (GSHPs) with water wells. Four configurations are modeled and compared, a CO 2 air-source heat pump (ASHP), an R-410A ASHP, a CO 2 GSHP with water well integration, and an R-410A ground-source heat pump with water well integration. System simulations are conducted at both equipment and whole-building levels, followed by a nationwide analysis across ten representative cities using EnergyPlus. Results show that water-well-coupled GSHPs maintain approximately 87 % of their efficiency and 85.5 % of heating capacity as ambient temperature drops from 47 °F/8.3 °C to −15 °F/-26.1 °C, whereas ASHPs retain only 55 % efficiency and 44.5 % capacity. R-410A systems achieve higher efficiency, while CO 2 systems provide significant environmental advantages, including reduced risks of groundwater contamination from refrigerant leakage. On average, the CO 2 GSHPs deliver 35–45 % heating energy savings relative to ASHPs and demonstrate strong potential as a replacement for gas furnaces in cold climates. This work represents a systematic comparative assessment of CO 2 and R-410A air-source and ground-source heat pumps with water well integration. In conclusion, the findings highlight the technical viability, environmental benefits and deployment potential of CO 2 GSHPs, offering a pathway toward efficient and sustainable residential heating solutions in diverse U.S. climates.

CO 2 GSHP↗

Unifying Advective and Diffusive Descriptions of Bedform Pumping in the Benthic Biolayer of Streams

Abstract Many water quality and ecosystem functions performed by streams occur in the benthic biolayer, the biologically active upper (~5 cm) layer of the streambed. Solute transport through the benthic biolayer is facilitated by bedform pumping, a physical process in which dynamic and static pressure variations over the surface of stationary bedforms (e.g., ripples and dunes) drive flow across the sediment‐water interface. In this paper we derive two predictive modeling frameworks, one advective and the other diffusive, for solute transport through the benthic biolayer by bedform pumping. Both frameworks closely reproduce patterns and rates of bedform pumping previously measured in the laboratory, provided that the diffusion model's dispersion coefficient declines exponentially with depth. They are also functionally equivalent, such that parameter sets inferred from the 2D advective model can be applied to the 1D diffusive model, and vice versa. The functional equivalence and complementary strengths of these two models expand the range of questions that can be answered, for example, by adopting the 2D advective model to study the effects of geomorphic processes (such as bedform adjustments to land use change) on flow‐dependent processes and the 1D diffusive model to study problems where multiple transport mechanisms combine (such as bedform pumping and turbulent diffusion). By unifying 2D advective and 1D diffusive descriptions of bedform pumping, our analytical results provide a straightforward and computationally efficient approach for predicting, and better understanding, solute transport in the benthic biolayer of streams and coastal sediments.

Grant, Stanley B.↗

A path to scaling helium-3 spin-exchange optical pumping

Polarized 3 He has contributed to breakthroughs in particle physics, neutron scattering, and lung imaging, mostly by optical pumping of liter quantities in valved cells or in sealed cells pumped in situ. Only metastability exchange optical pumping currently meets the demand for delivering large quantities of highly polarized 3 He to external volumes. Our development program is under way to achieve medium to large-scale spin-exchange optical pumping of 3 He. Thin-walled aluminosilicate cells placed in contact with thermal reservoirs inside a pressure vessel were optically pumped with kilowatt-scale lasers spectrally narrowed to match pressure-broadened absorption linewidths. We report here the key elements of this program and significant milestones: multi-liter volume valved cells that provide long longitudinal lifetimes that reached polarization as high as 85% inside a thermally stable and pressurized environment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗