DOE OSTI · 3002363
Comparative performance assessment of air-source and ground-source heat pumps using CO₂ and R-410A with water well integration: A simulation study
Abstract
This study investigates the performance and feasibility of heat pump systems for residential space heating in cold climates, with a particular focus on ground source heat pumps (GSHPs) with water wells. Four configurations are modeled and compared, a CO 2 air-source heat pump (ASHP), an R-410A ASHP, a CO 2 GSHP with water well integration, and an R-410A ground-source heat pump with water well integration. System simulations are conducted at both equipment and whole-building levels, followed by a nationwide analysis across ten representative cities using EnergyPlus. Results show that water-well-coupled GSHPs maintain approximately 87 % of their efficiency and 85.5 % of heating capacity as ambient temperature drops from 47 °F/8.3 °C to −15 °F/-26.1 °C, whereas ASHPs retain only 55 % efficiency and 44.5 % capacity. R-410A systems achieve higher efficiency, while CO 2 systems provide significant environmental advantages, including reduced risks of groundwater contamination from refrigerant leakage. On average, the CO 2 GSHPs deliver 35–45 % heating energy savings relative to ASHPs and demonstrate strong potential as a replacement for gas furnaces in cold climates. This work represents a systematic comparative assessment of CO 2 and R-410A air-source and ground-source heat pumps with water well integration. In conclusion, the findings highlight the technical viability, environmental benefits and deployment potential of CO 2 GSHPs, offering a pathway toward efficient and sustainable residential heating solutions in diverse U.S. climates.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Sun, Jian [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)] (ORCID:0000000302874302), Li, Yanfei [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)], Kashif, Nawaz [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)] (ORCID:0000000251612491), Liu, Xiaobing [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)] (ORCID:000000028457249X), Lian, Jamie [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)], Pagnotti, Anthony [Dalrada Corporation, Escondido, CA (United States)], Neill, Emily [Dalrada Corporation, Escondido, CA (United States)], Donald, Peter [Dalrada Corporation, Escondido, CA (United States)]. 2025-10-22. Comparative performance assessment of air-source and ground-source heat pumps using CO₂ and R-410A with water well integration: A simulation study. https://doi.org/10.1016/j.jobe.2025.114453
Cite the original work for its findings. Save a collection to share your selection of sources.