At least 145 records · Page 8

Highlights of the Zeno Results from the USMP-2 Mission

The Zeno instrument, a High-precision, light-scattering spectrometer, was built to measure the decay rates of density fluctuations in xenon near its liquid-vapor critical point in the low-gravity environment of the U.S. Space Shuttle. Eliminating the severe density gradients created in a critical fluid by Earth's gravity, we were able to make measurements to within 100 microKelvin of the critical point. The instrument flew for fourteen days in March, 1994 on the Space Shuttle Columbia, STS-62 flight, as part of the very successful USMP-2 payload. We describe the instrument and document its performance on orbit, showing that it comfortably reached the desired 3 microKelvin temperature control of the sample. Locating the critical temperature of the sample on orbit was a scientific challenge; we discuss the advantages and short-comings of the two techniques we used. Finally we discuss problems encountered with making measurements of the turbidity of the sample, and close with the results of the measurement of the decay rates of the critical-point fluctuations.

Gammon, Robert W.↗

Viscoelasticity of Xenon near the Critical Point

Using a novel, overdamped, oscillator flown aboard the Space Shuttle, we measured the viscosity of xenon near the liquid-vapor critical point in the frequency range 2 Hz less than or equal to f less than or equal to 12 Hz. The measured viscosity divergence is characterized by the exponent z(sub eta) = 0.0690 +/- 0.0006, in agreement with the value z(sub eta) = 0.067 +/- 0.002 calculated from a two-loop perturbation expansion. Viscoelastic behavior was evident when t = (T - T(sub c))/T(sub c) less than 10(exp -5) and dominant when t less than 10(exp -6), further from T(sub c) than predicted. Viscoelastic behavior scales as Af(tau) where tau is the fluctuation decay time. The measured value of A is 2.0 +/- 0.3 times the result of a one-loop calculation. (Uncertainties stated are one standard uncertainty.)

Berg, Robert F.↗

Improvements to a Flow Sensor for Liquid Bismuth-Fed Hall Thrusters

Recently, there has been significant interest in using bismuth metal as a propellant in Hall Thrusters [1, 2]. Bismuth offers some considerable cost, weight, and space savings over the traditional propellant--xenon. Quantifying the performance of liquid metal-fed Hall thrusters requires a very precise measure of the low propellant flow rates [1, 2]. The low flow rates (~10 mg/sec) and the temperature at which free flowing liquid bismuth exists (above 300 C) preclude the use of off-the-shelf flow sensing equipment [3]. Therefore a new type of sensor is required. The hotspot bismuth flow sensor, described in Refs. [1-5] is designed to perform a flow rate measurement by measuring the velocity at which a thermal feature moves through a flow chamber. The mass flow rate can be determined from the time of flight of the thermal peak, [4, 5]. Previous research and testing has been concerned mainly with the generation of the thermal peak and it's subsequent detection. In this paper, we present design improvements to the sensor concept; and the results of testing conducted to verify the functionality of these improvements. A ceramic material is required for the sensor body (see Fig. 1), which must allow for active heating of the bismuth flow channel to keep the propellant in a liquid state. The material must be compatible with bismuth and must be bonded to conductive elements to allow for conduction of current into the liquid metal and measurement of the temperature in the flow. The new sensor requires fabrication techniques that will allow for a very small diameter flow chamber, which is required to produce useful measurements. Testing of various materials has revealed several that are potentially compatible with liquid bismuth. Of primary concern in the fabrication and testing of a robust, working prototype, is the compatibility of the selected materials with one another. Specifically, the thermal expansion rates of the materials relative to the ceramic body cannot expand so much as to cause cracks in the body or cause the bond between parts to delaminate. Those parts that will carry the current pulse must be electrically conductive while the sensor body must be an electrical insulator. Generally, the material choices as well as the sensor design must aid to preserve the integrity of the thermal feature to obtain accurate measurements. The present aim is to also incorporate, into the sensor body, an active heating arrangement based on ceramic heater technology similar to that used in semiconductor manufacturing.

Bonds, Kevin↗

Critical fluid light scattering

Thermal fluctuations give rise to a host of thermodynamic anomalies near critical points. The background for these phenomena is presented, and an experimental design on STS flight experiment called Zeno is described. The objective is to measure the decay rates of critical density fluctuations in a simple fluid (xenon) very near its liquid-vapor critical point using laser light scattering and photon correlation spectroscopy. Such experiments have been limited on Earth by the presence of gravity, which causes large density gradients in the sample. Fluctuation decay rates in xenon will be measured at least 100 times closer to the critical point than is possible on Earth. This will require taking data as close as 145 micro K to the critical temperature, after locating it to + or - 10 micro K. The minimum mission time of 100 hours will allow a complete range of temperature points to be covered, limited by the thermal response of the sample. An essential part of the apparatus is the thermostat. Its design principles and key features are given together with some observed performance characteristics of a prototype: + or - 20 micro K stability for 18 hours, and one minute programmed step response for steps less than 10 mK.

Gammon, Robert W.↗

Critical fluid light scattering

Thermal fluctuations give rise to a host of thermodynamic anomalies near critical points. The background for these phenomena is presented, and an experiment design on STS flight experiment called 'Zeno' described. The objective is to measure the decay rates of critical density fluctuations in a simple fluid (xenon) very near its liquid-vapor critical point using laser light-scattering and photon-correlation spectroscopy. Such experiments have been limited on earth by the presence of gravity, which causes large density gradients in the sample. Fluctuation decay rates in xenon will be measured at least 100 times closer to the critical point than is possible on earth. This will require taking data as close as 145 microK to the critical temperature (Tc = 289.72 K), after locating it to + or - 10 microK. The minimum mission time of 100 hours will allow a complete range of temperature points to be covered, limited by the thermal response of the sample. An essential part of the apparatus is the thermostat. Its design principles and key features are given together with some observed performance characteristics of a prototype: + or - 20 microK stability for 18 hours, and one minute programmed step response for steps less than 10 mK.

Gammon, Robert W.↗

TinyTPC: A TEST STAND FOR LAr DOPING

TinyTPC is a small scale liquid-argon time projection chamber (LArTPC) that studies how photosensitive dopants can improve the energy resolution of low energy events in LArTPCs. Bench tests to resolve high voltage breakdown issues and to improve the low voltage system readout are described. Experimental data with a radioactive source of Th-228 for the calibration of the pixelated readout and the characterization of TinyTPC's energy resolution is explained. Provisional results from the addition of isobutylene (photosensitive dopant) and xenon (wavelength shifter) to liquid-argon (LAr) are also presented. Further steps to improve voltage system and enhance the data collection are discussed.

Rodriguez Thorne, Paloma↗

Shear Thinning in Xenon

We measured shear thinning, a viscosity decrease ordinarily associated with complex liquids such as molten plastics or ketchup, near the critical point of xenon. The data span a wide range of dimensionless shear rate: the product of the shear rate and the relaxation time of critical fluctuations was greater than 0.001 and was less than 700. As predicted by theory, shear thinning occurred when this product was greater than 1. The measurements were conducted aboard the Space Shuttle Columbia to avoid the density stratification caused by Earth's gravity.

Bergm Robert F.↗

Light Scattering Tests of Fundamental Theories of Transport Properties in the Critical Region

The objective of this program is to measure the decay rates of critical density fluctuations in a simple fluid (xenon) very near its liquid-vapor critical point using laser light scattering and photon correlation spectroscopy. Such experiments have been severely limited on Earth by the presence of gravity which causes large density gradients in the sample when the compressibility diverges approaching the critical point. The goal is to measure decay rates deep in the critical region where the scaled wavevector is the order of 1000. This will require loading the sample to 0.01% of the critical density and taking data as close as 3 microKelvin to the critical temperature (Tc = 289.72 K). Other technical problems have to be addressed such as multiple scattering and the effect of wetting layers. The ability to avoid multiple scattering by using a thin sample (100 microns) was demonstrated, as well as a temperature history which can avoid wetting layers satisfactory temperature control and measurement, and accurate sample loading. Thus the questions of experimental art are solved leaving the important engineering tasks of mounting the experiment to maintain alignment during flight and automating the state-of-the-art temperature bridges for microcomputer control of the experiment.

Gammon, R. W.↗

Critical fluid light scattering

The objective is to measure the decay rates of critical density fluctuations in a simple fluid (xenon) very near its liquid-vapor critical point using laser light scattering and photon correlation spectroscopy. Such experiments were severely limited on Earth by the presence of gravity which causes large density gradients in the sample when the compressibility diverges approaching the critical point. The goal is to measure fluctuation decay rates at least two decades closer to the critical point than is possible on earth, with a resolution of 3 microK. This will require loading the sample to 0.1 percent of the critical density and taking data as close as 100 microK to the critical temperature. The minimum mission time of 100 hours will allow a complete range of temperature points to be covered, limited by the thermal response of the sample. Other technical problems have to be addressed such as multiple scattering and the effect of wetting layers. The experiment entails measurement of the scattering intensity fluctuation decay rate at two angles for each temperature and simultaneously recording the scattering intensities and sample turbidity (from the transmission). The analyzed intensity and turbidity data gives the correlation length at each temperature and locates the critical temperature. The fluctuation decay rate data from these measurements will provide a severe test of the generalized hydrodynamic theories of transport coefficients in the critical regions. When compared to equivalent data from binary liquid critical mixtures they will test the universality of critical dynamics.

Gammon, Robert W.↗

Calibration of the Oscillating Screen Viscometer

We have devised a calibration procedure for the oscillating screen viscometer which can provide the accuracy needed for the flight measurement of viscosity near the liquid-vapor critical point of xenon. The procedure, which makes use of the viscometer's wide bandwidth and hydrodynamic similarity, allows the viscometer to be self-calibrating. To demonstrate the validity of this procedure we measured the oscillator's transfer function under a wide variety of conditions. We obtained data using CO2 at temperatures spanning a temperature range of 35 K and densities varying by a factor of 165, thereby encountering viscosity variations as great as 50%. In contrast the flight experiment will be performed over a temperature range of 29 K and at only a single density, and the viscosity is expected to change by less than 40%. The measurements show that, after excluding data above 10 Hz (where frequency-dependent corrections are poorly modeled) and making a plausible adjustment to the viscosity value used at high density, the viscometer's behavior is fully consistent with the use of hydrodynamic similarity for calibration. Achieving this agreement required understanding a 1% anelastic effect present in the oscillator's torsion fiber.

Berg, Robert F.↗

Performance of black silicon photodiodes for VUV detection in noble liquids

Black silicon (b-Si) photodiodes are an emerging technology that employs silicon nanostructures to enhance the efficiency of photon detection. Recently, we demonstrated nearly 100% quantum efficiency at <200 nm vacuum ultraviolet (VUV) wavelengths at ambient and in noble liquids, making such devices particularly useful for direct detection of scintillation light in noble liquid detectors. This is important in nuclear science experiments like DarkSide, LUX, XENON, and nEXO, where detection of weak VUV scintillation photons in noble liquids are used to identify rare physics radiation events. Here, we measured the response of b-Si photodiode to the scintillation light generated by alpha particles, all immersed in a LAr and LXe test cell. We established a guideline for future development of b-Si photodetectors with internal gain to reach single-photon sensitivity.

47 OTHER INSTRUMENTATION↗

Progress on Acoustic Measurements of the Bulk Viscosity of Near-Critical Xenon (BVX)

We plan to determine the bulk viscosity of xenon 10 times closer [in reduced temperature tau = (T-Tc)/Tc] to its liquid-vapor critical point than ever before. (Tc is the critical temperature.) To do so, we must measure the dispersion and attenuation of sound at frequencies 1/100 of those used previously. In general, sound attenuation has contributions from the bulk viscosity acting throughout the volume of the xenon as well as contributions from the thermal conductivity and the shear viscosity acting within thin thermoacoustic boundary layers at the interface between the xenon and the solid walls of the resonator. Thus, we can determine the bulk viscosity only when the boundary layer attenuation is small and well understood. We present a comparison of calculations and measurements of sound attenuation in the acoustic boundary layer of xenon near its liquid-vapor critical point.

Gillis, Keith A.↗

Densitometer system for liquid hydrogen has high accuracy, fast response

Developmental densitometer system for cryogenic liquids uses two balanced ionization chambers containing xenon gas, with X rays as the radiation source. The X rays are heavily filtered with a lead shield to make the energy spectrum much less dependent on the voltage applied to the X ray tube.

Source record↗

Characterization of spurious-electron signals in the double-phase argon TPC of the DarkSide-50 experiment

Spurious-electron signals in dual-phase noble-liquid time projection chambers have been observed in both xenon and argon Time Projection Chambers (TPCs). This paper presents the first comprehensive study of spurious electrons in argon, using data collected by the DarkSide-50 experiment at the INFN Laboratori Nazionali del Gran Sasso (LNGS). Understanding these events is a key factor in improving the sensitivity of low-mass dark matter searches exploiting ionization signals in dual-phase noble liquid TPCs. We find that a significant fraction of spurious-electron events, ranging from 30 to 70% across the experiment's lifetime, are caused by electrons captured from impurities and later released with delays of order 5-50 ms. The rate of spurious-electron events is found to correlate with the operational condition of the purification system and the total event rate in the detector. Finally, we present evidence that multi-electron spurious electron events may originate from photo-ionization of the steel grid used to define the electric fields. These observations indicate the possibility of reduction of the background in future experiments and hint at possible spurious electron production mechanisms.

Agnes, P. [GSSI, Aquila; Gran Sasso]↗

Transport of Highly Volatile Gases Related to Noble Gases and Tritium in the MSRE

This study aims to comprehend mass transfer in the closed-loop circulation of highly volatile gases, including noble gases and tritium. We explore the impact of steady-state xenon-135 and tritium on the MSRE and reveal their isotopic distributions using online noble gas stripping of fuel salts. The MSRE was engineered to extract fission product gases from fuel salts and efficiently eliminate inert gases with the help of helium bubbles within a circulating fuel pump. These reactors introduce significant theoretical challenges in estimating interfacial area and mass transfer coefficients, crucial for modeling mass transfer processes. An essential component of our analysis is the mass transfer coefficient. These coefficients are important for understanding how radionuclides move during various phase transitions within a nuclear reactor. Xenon-135 and tritium are found in both liquid and gas phases within the reactor system. In the liquid phase, they dissolve in molten salts, while in the gas phase, they manifest as bubbles. These elements have significant adverse effects on reactor operation due to their strong neutron absorption properties, influencing both safety and performance. The Mole code, which predicts the behavior of chemical species under steady-state conditions, facilitates multiphysics coupling with Griffin to update species distributions and address inherent MSR safety.

Lee, Kyoung↗

Measurement of the Muon Flux at the Sanford Underground Research Facility with the LUX-ZEPLIN Dark Matter Detector

High-energy cosmic-ray muons reaching deep underground laboratories can cause events in detectors that mimic signals expected from dark matter particles, neutrinos, or rare decays. Knowledge of the muon flux and energy spectrum is important for evaluating the background rate caused by muons and their secondaries. In this paper, we report the measurement of the cosmic-ray muon flux in the Davis Campus of the Sanford Underground Research Facility with the LUX-ZEPLIN detector. Using 366.4~days of exposure, the muon rate through the detector was measured as $10.94\pm0.17_\textrm{stat.}~\textrm{day}^{-1}$ with energy thresholds of 20~MeV in the inner xenon detector and 8 MeV in the outer liquid scintillator detector. This rate corresponds to a muon flux of $(5.09\pm0.08_\textrm{stat.}\pm0.10_\textrm{sys.})\times10^{-9}~\textrm{cm}^{-2}\textrm{s}^{-1}$ in the Davis Cavern.

Akerib, D. S. [SLAC; Stanford U., Phys. Dept.; KIP↗

Enabling Load Following Capability in the Transatomic Power MSR

This project is dedicated towards designing a fuel processing system that enables liquid-fueled molten salt reactors (MSR) to load follow by removing the dissolved xenon in the fuel salt. As one of the Gen-IV nuclear reactor concepts, the molten salt reactor receives increasing development interests in the recent years. One distinguishing feature of the liquid-fueled molten salt reactor is its improved ability to operate in a load-following mode by including the unique online fission product removal system. Load-following means that the reactor changes its power output based on the demand on the grid. Most of the current operating nuclear reactors have limited load-following ability and operate as the base load on the grid. Due to the rapid increase of solar energy, the requirement on load-following capacity is significantly increased because of the varying power output of the solar panels, yet the traditional load-following capacity is expected to decrease as the decarbonization of the grid continues. Therefore, the ability to perform load-following operation for the nuclear reactors will greatly enhance the resilience of the grid and make nuclear energy more economically competitive. This load-following feature is included in many commercial molten salt reactor designs, such as the designs by Transatomic Power, Terrestrial Energy, and Flibe Energy. Unfortunately, detailed analysis of the fuel processing system for commercial scale MSRs is still lacking, as well as how the fuel processing quantitively impacts the load-following operation. Moreover, experimental data for many of the underlying physics of fuel processing is limited. This project aims to pave the way for the fuel processing technology to advance to the commercial stage by performing combined experimental and simulation research. During the project period, four interconnected aspects of the development of the fuel processing system in liquid-fueled molten salt reactors are investigated. These aspects are the simulation and analysis of the fission product removal system, the fuel cycle simulation, the coupled reactor neutronics and thermal hydraulics transient simulation, and the gaseous fission product removal experiment. Multiphase CFD simulations are performed for components of the processing systems, and simplified air-water experiments are carried out to provide validation data. It is concluded that the CFD simulation can satisfactorily predict the system level performance of the components, and engineering models are constructed based on this success. Fuel cycle analysis is performed for two representative MSR design, the MSBR and the Transatomic Power MSR. Open-source code SaltProc is developed to incorporate the unique fuel processing system of the MSRs. It is concluded that the removal of xenon is essential for load-following operation in thermal spectrum MSR and Molten Salt Breeder Reactor. For the Transatomic Power MSR, the xenon poisoning effect is negligible due to its relatively fast neutron spectrum, though the overall fuel cycle economics still benefits from the removal of xenon. Coupled reactor neutronics and thermal hydraulics transient simulation is performed specifically for the Transatomic Power MSR. It is concluded that the reactor core design could perform power ramping fast enough to satisfy load-following operation. Combining the findings from each aspect, it is concluded that the load-following operation of a thermal neutron MSR is dependent upon the removal of xenon, which could be achieved for a commercial sized reactor using continuous inert gas sparging in a separate system with reasonable dimensions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗