Micrometer-accuracy 2D displacement interferometer with plasmonic metasurface resonators

In this Letter, a high-accuracy, two-dimensional displacement sensor is proposed, designed, and demonstrated based on the concept of an extrinsic Fabry–Perot Interferometer. The sensor is composed of two bundled single-mode optic fibers in parallel and two plasmonic metasurface resonators inscribed on a gold substrate via a focused ion beam. The fiber end surface and the metasurface are in parallel with a small cavity between. The cavity change or Z -component displacement is determined from the pattern of interference fringes. The X -component displacement, perpendicular to the Z component, is identified from wavelength-selective metasurface resonators, which possess unique resonant wavelengths due to different nanostructure designs. The sensor was calibrated with six displacements applied through a three-axis precision linear stage. Test results indicated that the proposed interferometer can measure displacements with a maximum error of 5.4 µm or 2.2%.

Guo, Chuanrui (ORCID:0000000271412972)↗

A Laboratory Atom Interferometer Instrument

We have demonstrated a laboratory based, high bandwidth atom interferometer instrument and have performed an incipient gravity measurement with a fractional statistical uncertainty of ag/g = 4.4 x 10 -6 where g is the acceleration due to gravity. We have designed, constructed, and optimised numerous laser systems for this purpose, most notably a powerful Raman laser (12 W at 780 nm) which will allow large momentum transfer and large detuning interferometry to be carried out at high bandwidth for the first time. This experiment is a general purpose test bed for exploring the fundamental limitations of atom interferometer techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of Atom Interferometer Accelerometer

This report presents the theoretical effort to model and simulate the atom-interferometer accelerometer operating in a highly mobile environment. Multitudes of non-idealities may occur in such a rapidly-changing environment with a large acceleration whose amplitude and direction both change quickly. We studied the undesired effect of high mobility in the atom-interferometer accelerator in a detailed model and a simulator. The undesired effects include the atom cloud's movement during Raman pulses, the Doppler effect due to the relative movement between the atom-cloud and the supporting platform, the finite atom cloud temperature, and the lateral movement of the atom cloud. We present the relevant feed-forward mitigation strategies for each identified non-ideality to neutralize the impact and obtain accurate acceleration measurements.

43 PARTICLE ACCELERATORS↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The MAGIS-100 Experiment and a Future, Kilometer-scale Atom Interferometer

The dearth of signals unambiguously attributable to WIMP dark matter motivates exploring new parameter space, particularly the ultra-light dark matter (ULDM) regime, where the signal is not scattering events but wave phenomena. The proliferation of quantum technologies has enabled searches for ULDM at previously inaccessible sensitivity. One such technology is atom interferometry which can measure time-dependent fluctuations in the energy spacing of atoms as well as in the light-travel time across the apparatus, enabling searches for ULDM and gravitational waves, respectively. In this talk, I will review the science case for long baseline atom interferometers, such as MAGIS-100 at Fermilab, provide an update on the experiment’s status, and discuss the need for a future, kilometer-scale atom interferometer which would achieve unprecedented sensitivity to ULDM and gravitational waves in the “Mid-Band” region between LIGO and LISA.

Temples, Dylan J. [Fermilab] (ORCID:00000001601725↗

Measurements of Martin-Puplett Interferometer Limitations using Blackbody Source

Frequency domain measurements with Martin-Puplett interferometer is one of a few techniques capable of bunch length measurements at the level of ~ 100 fs. As the bunch length becomes shorter, it is important to know and be able to measure the limitations of the instrument in terms of shortest measurable bunch length. In this paper we describe an experiment using a blackbody source with the modified Martin-Puplett interferometer that is routine- ly used for bunch length measurements at the JLab FEL, as a way to estimate the shortest, measurable bunch length. The limitation comes from high frequency cut-off of the wire-grid polarizer currently used and is estimated to be 50 fs RMS. The measurements are made with the same Golay cell detector that is used for beam measure- ments. We demonstrate that, even though the blackbody source is many orders of magnitude less bright than the coherent transition or synchrotron radiation, it can be used for the measurements and gives a very good signal to noise ratio in combination with lock-in detection. We also compare the measurements made in air and in vacuum to characterize the very strong effect of the atmospheric absorption.

43 PARTICLE ACCELERATORS↗

39 GHz Interferometer System for Measuring Detonation Velocity

A new 39 GHz RF interferometer system is presented for use in velocity measurements of high explosives (HE) detonations. The frequency was chosen to compliment the currently available suite, and provide more spatial information. An RF signal is generated and coupled to a waveguide adapter serving as an antenna. The HE is initially transparent to the RF. When the HE detonates, the detonation front becomes reflective to the RF. This reflection is picked up by the waveguide adapter and mixed with an unperturbed RF signal to give a low frequency signal which can be digitized with an oscilloscope. By comparing the signal with a reference signal, velocity information can be obtained using Fourier Transforms and wavelet models. Bench test results using a “slapper” are shown. The 39 GHz microwave interferometer is used in Deflagration to Detonation shots. The signal is reflected off a moving surface, and the Doppler shift of the reflected signal is used to calculate the velocity.

Ross, Patrick W.↗

The Laser Interferometer Space Antenna: Unveiling the Millihertz Gravitational Wave Sky

The first terrestrial gravitational wave interferometers have dramatically underscored the scientific value of observing the Universe through an entirely different window, and of folding this new channel of information with traditional astronomical data for a multimessenger view. The Laser Interferometer Space Antenna (LISA) will broaden the reach of gravitational wave astronomy by conducting the first survey of the millihertz gravitational wave sky, detecting tens of thousands of individual astrophysical sources ranging from white-dwarf binaries in our own galaxy to mergers of massive black holes at redshifts extending beyond the epoch of reionization. These observations will inform - and transform - our understanding of the end state of stellar evolution, massive black hole birth, and the co-evolution of galaxies and black holes through cosmic time. LISA also has the potential to detect gravitational wave emission from elusive astrophysical sources such as intermediate-mass black holes as well as exotic cosmological sources such as inflationary fields and cosmic string cusps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-dimensional second harmonic dispersion interferometer

An interferometer having a fundamental beam generator, a first second harmonic generator, a waveplate, a second second harmonic generator, a harmonic separator, and a polarizing beam splitter, mounted uniaxially, (i.e., the components are aligned along one optical axis), wherein the interferometer is adapted to change a diameter of a beam to match a diameter of a sample, and to change the diameter of the beam back to its original diameter.

Wessel, Frank Joseph↗

Multi-axis Accelerometry and Rotation Sensing using a Point Source Atom Interferometer

A point source atom interferometer (PSI) is a device where atoms are split and recombined by applying a temporal sequence of Raman pulses during the expansion of a cloud of cold atoms behaving approximately as a point source. Unlike a conventional light pulse atom interferometer, the PSI can produce a signal that corresponds to multi-axis rotation only, independent of acceleration. In addition, it can be used to measure acceleration along one direction, independent of rotation. Here, we describe a modified PSI that can be used to measure multi-axis rotation and multi-axis acceleration. Specifically, this type of PSI can be used to measure two-axes rotation around the directions perpendicular to the light pulses, as well as the acceleration in all three directions, with only one pair of Raman beams. Using two pairs of Raman beams in orthogonal directions sequentially, such a scheme would enable the realization of a complete atom interferometric inertial measurement unit.

Li, Jinyang↗

Polarisation non-reciprocity cancelling in Sagnac fibre ring interferometer: an attempt of realistic study

Polarisation non-reciprocity (PNR) of Sagnac fibre ring interferometer (FRI) is one the fundamental limits of its long term bias stability. PNR value, being huge initially, then was reduced strongly, but after that PNR problem was left far from PNR cancelling. The latter may be defined as PNR reducing up to 10{sup −10} deg/h when it does not prevent detecting the general relativistic Lense–Thirring effect. Clearly, such PNR cancelling may be treated only theoretically at this point. In this case, one has to model all practical defects of FRI. Present paper describes such kind of study for FRI of commercial fibre optic gyro implementing medium quality components. It is shown that for PNR cancelling, several meters fibre polariser is enough, despite of the stringent limitations of its standard polarisation extinction ratio. Also, a complete FRI configuration is treated for the first time in available literature, including an imperfect fibre coupler. This yields one more PNR component which is non-zero even for completely unpolarised light and which can be effectively suppressed by the fibre polariser too.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiwavelength erbium-doped fiber laser based on a polarization-dependent in-line Mach–Zehnder interferometer

A multiwavelength erbium-doped fiber laser based on a polarization-dependent in-line Mach–Zehnder Interferometer (in-line MZI) is proposed and experimental demonstrated. The polarization-dependent in-line MZI demonstrated is constructed by sandwiching a length of polarization maintaining fiber (PMF) between two abrupt fiber tapers fabricated in SMF. The proposed in-line MZI can work as a cost-effective all-fiber-based polarizer. In combination with the nonlinear polarization rotation technique, stable multiwavelength laser comb with uniform wavelength spacing is achieved at room temperature. The wavelength spacing is 0.8 nm. By properly tuning the PCs, the output laser combs with double and triple channel spacing can be also obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Waveform modelling for the Laser Interferometer Space Antenna

LISA, the Laser Interferometer Space Antenna, will usher in a new era in gravitational-wave astronomy. As the first anticipated space-based gravitational-wave detector, it will expand our view to the millihertz gravitational-wave sky, where a spectacular variety of interesting new sources abound: from millions of ultra-compact binaries in our Galaxy, to mergers of massive black holes at cosmological distances; from the early inspirals of stellar-mass black holes that will ultimately venture into the ground-based detectors’ view to the death spiral of compact objects into massive black holes, and many sources in between. Central to realising LISA’s discovery potential are waveform models, the theoretical and phenomenological predictions of the pattern of gravitational waves that these sources emit. This White Paper is presented on behalf of the Waveform Working Group for the LISA Consortium. It provides a review of the current state of waveform models for LISA sources, and describes the significant challenges that must yet be overcome.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photon wave function formalism for analysis of Mach–Zehnder interferometer and sum-frequency generation

Biakynicki-Birula introduced a photon wave function similar to the matter wave function that satisfies the Schrödinger equation. Its second quantization form can be applied to investigate nonlinear optics at nearly full quantum level. In this paper, we applied the photon wave function formalism to analyze both linear optical processes in the well-known Mach–Zehnder interferometer and nonlinear optical processes for sum-frequency generation in dispersive and lossless medium. Results by photon wave function formalism agree with the well-established Maxwell treatments and existing experimental verifications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adiabatic Mach–Zehnder interferometer in a dipolar spin-1 condensate

We propose and analyze a realizable scheme for performing a Heisenberg-limited Mach–Zehnder interferometry with a dipolar spin-1 condensate. Based upon adiabatic processes of sweeping the transverse magnetic field, we demonstrate a perfect phase transition, which accomplishes the beam splitter, phase shifter and recombiner as for a Mach–Zehnder interferometer. The attractive dipolar interaction ensures the existence of a path-entangled state which enhances the phase measurement precision to the Heisenberg limit. We also study the spin squeezing of the state generated in the beam splitter and show that the spin squeezing exhibits an extremum near the critical point of phase transition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A metal-ceramic coaxial cable with multipoint Fabry-Pérot interferometers for monitoring distributed high temperature

A metal ceramic coaxial cable (MCCC) sensor containing multiple Fabry-Pérot interferometers (FPIs) has been designed, fabricated, and evaluated for measuring distributed high temperatures. The MCCC sensor demonstrated here consists of stainless steel tube and wire conductors, alumina tube insulator, and three pairs of air gap reflectors distributed along the cable. The multipoint sensor operation is realized by the joint time-frequency domain technique, which combines the functions of time-domain reflectometry and frequency division multiplexing to enable the measurement of spatially distributed temperature. The 3-point MCCC-FPI sensor has been demonstrated for distributed temperature measurements between 250 and 550 °C and operability up to 1000 °C. The sensor offers high sensitivity of >0.18 MHz/°C with a measurement resolution of 1 Hz and reasonably small high temperature measurement error range of ±3 °C.

42 ENGINEERING↗

A metal-ceramic coaxial cable Fabry-Pérot microwave interferometer for monitoring fluid dielectric constant

We report a metal-ceramic coaxial cable Fabry-Pérot interferometer (MCCC-FPI) has been developed as a new microwave sensor and demonstrated for fast and reliably measuring and continuously monitoring dielectric constants for pure and mixed liquids. The sensor only requires a simple reference scan of the interferogram for the FPI with its sensing chamber filled with air or under vacuum to determine the actual inter-reflector length. The sensor is validated by measuring room temperature dielectric constant (εr) at high frequencies around 1.4–4.7 GHz for three vegetable oils (corn, sesame, and olive), the synthetic Mobil ® -1 engine oil, and mixtures containing sesame oil and water. The sensor has been also successfully demonstrated for determining εr values for the Mobil-1 oil at various temperatures and for the well-dispersed sesame oil-water mixtures of different compositions. The Bottcher’s model of effective medium theory is shown to be better suited for predicting the ε r of the sesame oil-water mixture than the Maxwell-Garnett and Bruggeman equations of spherical solutions.

47 OTHER INSTRUMENTATION↗

Multiplexable intrinsic Fabry-Pérot interferometers inscribed by femtosecond laser for vibration measurement in high temperature environments

This article reports fabrication technique and demodulation algorithm developments to use multiplexable intrinsic Fabry-Pérot interferometer (IFPI) fiber sensor array for distributed vibration measurements at high temperatures. Using femtosecond laser direct writing scheme, IFPI array were fabricated through laser-induced Type II scattering points in single mode fiber cores. Reflection spectra of IFPI array were demodulated in real-time using modified Bunemen frequency analysis. The demodulation algorithm, which was implemented using a photodetector-array spectrometer, achieves 64-nε dynamic strain resolution at 1-kHz spectral acquisition rate and 2-kHz maximum vibration bandwidth. Performance and stabilities of IFPI sensor array were characterized from room temperatures to 800 °C. The static strain resolution was 0.6 με and the minimum detectable dynamic strain amplitude was 23 nε/√Hz at 800 °C. The multiplex performance was also tested by measuring dynamic strain in time domain through six IFPI sensor array fabricated in one fiber. This paper presents an integrated and low-cost sensing solution to perform distributed vibration measurements in harsh environments.