A compact rotary vane attenuator

Rotary vane attenuator, when used as a front end attenuator, introduces an insertion loss that is proportional to the angle of rotation. New technique allows the construction of a shortened compact unit suitable for most installations.

Nixon, D. L.↗

Rotary antenna attenuator

Radio frequency attenuator, having negligible insertion loss at minimum attenuation, can be used for making precise antenna gain measurements. It is small in size compared to a rotary-vane attenuator.

Dickinson, R. M.↗

High-power microstrip RF switch

A microstrip-type single-pole double-throw (SPDT) switch whose RF and bias portions contain only a metallized alumina substrate and two PIN diodes has been developed. A technique developed to eliminate the dc blocking capacitors needed for biasing the diodes is described. These capacitors are extra components and could lower the reliability significantly. An SPDT switch fabricated on a 5.08 x 5.08 x 0.127-cm (2 x 2 x 0.050-in.) substrate has demonstrated an RF power-handling capability greater than 50 W at S-band. The insertion loss is less than 0.25 db and the input-to-off port isolation is greater than 36 db over a bandwidth larger than 30 MHz. The input voltage standing-wave ratio is lower than 1.07 over the same bandwidth. Theoretical development of the switch characteristics and experimental results, which are in good agreement with theory, are presented.

Choi, S. D.↗

Investigation of the tone-burst tube for duct lining attenuation measurement

The tone burst technique makes practical the laboratory evaluation of potential inlet and discharge duct treatments. Tone burst apparatus requires only simple machined parts and standard components. Small, simply made, lining samples are quickly and easily installed in the system. Two small electromagnetric loudspeaker drivers produce peak sound pressure level of over 166 db in the 3-square-inch sample duct. Air pump available in most laboratories can produce air flows of over plus and minus Mach 0.3 in the sample duct. The technique uses short shaped pulses of sound propagated down a progressive wave tube containing the sample duct. The peak pressure level output of the treated duct is compared with the peak pressure level output of a substituted reference duct. The difference between the levels is the attenuation or insertion loss of the treated duct. Evaluations of resonant absorber linings by the tone burst technique check attenuation values predicted by empirical formulas based on full scale ducts.

Soffel, A. R.↗

Gain calibration of a horn antenna using pattern integration

Gain measurement of a horn antenna using three different techniques is discussed. The methods include a two-antenna insertion loss measurement, a pattern integration method, and a near-field measurement method. The application of the pattern integration method is considered, as well as the evaluation of the near-field gain correction factors for the horn, which are determined by a method based directly on measured data. This method involves a spherical wave expansion of the experimental radiation pattern of the specific antenna being tested, rather than evaluation of an assumed analytical model. The spherical wave expansion is also compared to experimental near-field pattern data.

Ludwig, A. C.↗

High power microstrip RF switches.

Description of a microstrip-type single-pole double-throw switch, which uses only two PIN diodes, eliminates usual dc blocking capacitors, and has demonstrated an RF power handling capacity greater than 100 W CW at S-band. The insertion loss is less than 0.25 dB, and the input-to-off port isolation is greater than 36 dB over a bandwidth larger than 30 MHz.

Choi, S. D.↗

Error analysis for Mariner Venus/Mercury 1973 conducted at the JPL Mesa west antenna range

Theoretical analysis and experimental data are combined to yield the errors to be used with antenna gain, antenna patterns, and RF cable insertion loss measurements for the Mariner Venus-Mercury 1973 Flight Project. These errors apply to measurements conducted at the JPL Mesa, West Antenna Range, on the high gain antenna, low gain antenna, and RF coaxial cables.

Vincent, N. L.↗

Antennas for spaceborne microwave radiometers

Principles and applications of microwave radiometry to remote sensing of the earth from satellites are reviewed. Examples of some spaceborne radiometer systems currently in use or under consideration are given. The requirements on performance characteristics of microwave antennas for such spaceborne earth sensing radiometers, such as coverage, scanning, spatial resolution, insertion loss, beam efficiency, polarization purity, etc., and their effects on the overall radiometer system performance are discussed.

Shiue, J. C.-C.↗

Electro-optically-indexed microwave switch

Mechanical parts used in conventional switches to index stepper motor that drives switch elements are replaced by optoelectronic indexing device that controls magnetic-detent motor. Unit eliminates major source of wear and maintains detent accuracy longer. Design of device achieves reduction of insertion loss, crosstalk, and wave guide reflections when receiving and transmitting.

Neff, D. E.↗

Visible optical isolator using ZnSe

A compact Faraday effect optical isolator was constructed for visible wavelengths and tested at 5145 A. The nonreciprocal element of the isolator was polycrystalline zinc selenide placed in the magnetic field of a permanent magnet. For 5145 A the isolator had a 2.06-dB insertion loss and a 25.5-dB isolation. Indices of refraction and Verdet constants were measured for zinc selenide in the wavelength region from 4700 to 6300 A.

Wunderlich, J. A.↗

High frequency sound attenuation in short flow ducts

A geometrical acoustics approach is proposed as a practical design tool for absorbent liners in such short flow ducts as may be found in turbofan engine nacelles. As an example, a detailed methodology is presented for three different types of sources in a parallel plate duct containing uniform ambient flow. A plane wave whose wavefronts are not normal to the duct walls, an arbitrarily located point source, and a spatially harmonic line source are each considered. Optimal wall admittance distributions are found, and it is shown how to estimate the insertion loss for any admittance distribution. The extension of the methodology to realistic source distributions in variable area cylindrical or annular ducts containing arbitrary flow is shown to be conceptually straightforward and computationally practical on a vector-hardware digital computer.

Posey, J. W.↗

A directional filter diplexer using optical techniques for millimeter to submillimeter wavelengths

An optical diplexer for injection of a local oscillator into a mixer, useful in the submillimeter and short millimeter range, is described. It has very low insertion loss for both the signal and local oscillator (LO) and high rejection of LO noise. The measured performance of a unit tested at 337 GHz indicates a loss of about 0.2 dB for both inputs and 20-dB noise rejection.

Erickson, N. R.↗

Wind-tunnel fan noise reduction including effects of turning vanes on noise propagation

Fan silencers with low-pressure drop have been designed and installed in the NASA Ames 7- by 10-Foot Wind Tunnel No. 1. The silencers are composed of an absorbent lining flush with the wind-tunnel walls upstream of the fan and an absorbent splitter in the duct downstream of the fan. An acoustical insertion loss of 4 to 12 dB was measured between 100 and 1000 Hz. High-frequency performance of the silencers was reduced by test-section noise and by corner vanes which turned the sound waves so they followed the duct axis. Sound below 1.2 kHz diffracted around the 305-mm-long vanes and impinged on acoustically absorbent corner walls. Wind-tunnel flow losses are discussed.

Soderman, P. T.↗

Fiber optic level sensor for cryogens

Sensor is useful in cryogenic environments where liquids of very low index of refraction are encountered. It is "yes/no" indication of whether liquid is in contact with sensor. Sharp bends in fiber alter distribution of light among propagation modes. This amplifies change in light output observed when sensor contacts liquid, without requiring long fiber that would increse insertion loss.

Sharma, M.↗

Integrated optic waveguide devices

Integrated optic waveguide circuits with a phase bias and modulator on the same chip were designed, fabricated, and tested for use in a fiber-optic rotation sensor (gyro) under development. Single mode fiber-optic pigtails were permanently coupled to the four ports of the chip. The switch format was based on coherent coupling between waveguides formed in Z-cut LiNbO3. The control of the coupling was achieved by electro-optically varying the phase propagation constants of each guide. Fiber-to-chip interfacing required the development of appropriate fixturing and manipulation techniques to achieve the close tolerance needed for high coupling efficiency between a fiber with an approximately 5 micron m core and a channel guide with a roughly 2 micron m by 5 micron m cross section. Switch and chip performance at 0.85 micron m is discussed as well as potential improvements related to insertion loss reduction, switching voltages, and suppression of Li2O out-diffusion.

Ramer, O. G.↗