Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high voltage converter modulator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

132 records · Page 8

Commissioning of the large-scale lead tungstate scintillating calorimeter

Here, we report on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises 1596 high-granularity, high-resolution scintillating crystals optimized for electromagnetic-shower detection over a wide energy range. Scintillation light from each crystal is read out by Hamamatsu R4125 photomultiplier tubes equipped with a custom voltage divider and front-end amplifier to ensure stable gain at high rates. All calorimeter modules were fabricated and characterized using a light-emitting diode–based optical test system prior to installation to verify uniformity and photodetector performance. After installation, the electromagnetic calorimeter was fully integrated into the experiment data acquisition and energy-based trigger systems. The optical response of the modules was equalized using the light-monitoring system, cosmic-ray muons, and photons from Compton-scattering events. Commissioning results demonstrate a reliably calibrated optical response and stable detector performance during the first run. These results validate the calorimeter design and commissioning methodology for large-scale scintillator-based photonic instrumentation.

Analog to digital converters↗

Electron Density Measurements Using USPR (Final Scientific/Technical Report)

UC Davis has fabricated an ultrashort pulse reflectometer (USPR) diagnostic instrument for electron density profile measurements on compact, short duration, magnetically-confined fusion-energy concept devices such as spheromaks and FRCs. The USPR system transmits extremely short duration (~few nsec) chirped waveforms that together span 29 to 75 GHz. These chirped waveforms illuminate and reflect from the target plasma, with each frequency component reflecting from a different density layer (higher frequencies probe deeper into the plasma before reflecting). The reflected waveforms are split into roughly 42 different frequencies; time-of-flight (TOF) measurements made at each frequency with high resolution (~25 psec measurement resolution which corresponds to ~5 mm). These TOF data may then be inverted via software to generate electron density profiles with high time resolution (~10 μsec). At the heart of the system is a field programmable gate array (FPGA) based controller which collects and processes all of the USPR data in addition to generating all of the control signals required for maximum flexibility. The FPGA controller has the software flexibility to be easily reconfigured for different plasma devices, and the entire system sufficiently compact to be easily and quickly transported between devices. A high speed impulse generator was transformed into a set of three ultrashort pulse transmitter chirps using a combination of dispersive waveguide, frequency doublers and high-pass filters. A mm-wave controller was fabricated to sequentially switch between the three chirps, directing the chirps one-by-one to three different mm-wave assemblies spanning 29-75 GHz. Each mm-wave assembly consists of a high power active multiplier chain which converts the transmitter chirp to higher frequencies, and a broadband mixer which downconverts the reflected waveform to the 2-18 GHz range of the UPSR receiver. The 16-channel receiver (shared by all 3 mm-wave assemblies) was fabricated employing custom TOF modules capable of operating at a high 1 MHz sampling rate. Laboratory testing of the full system revealed the presence of unwanted harmonics from the multiplication process, with interference observed in the downconverted reflections at selected frequency channels that could not be completely filtered out. Additional interference effects arising from internal reflections within the mm-wave assemblies were minimized using a high-speed switch which served to “gate out” much of these reflections. The USPR diagnostic was transported and installed onto the HIT-SIU plasma device, becoming operational on 11/08/2022. Although designed to span 3 distinct mm-wave bands, the HIT-SIU plasmas at this time were sufficiently low density such that only the lowest of the three bands was likely to have strong plasma reflections. The system was then set to operate on only the lowest band (assembly #1), with data collected every 1 μsec rather than 3 μsec which would have been the case when cycling through all three bands. Connected to HIT-SIU, time-varying plasma reflections were observed on 9 of 16 possible frequency channels. Close examination of the data collected revealed issues previously unobserved in laboratory testing, associated with (a) reflections from the small aperture horns required for operation within the HIT-SIU device, and (b) a dependence of the recorded TOF with the threshold voltage of a given channel. Plans were made to address each of these issues before undertaking any future campaigns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nondestructive Evaluation (NDE) of Cable Anomalies using Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR)

This report presents a comparative assessment of the performance of frequency domain reflectometry (FDR) and spread spectrum time domain reflectometry (SSTDR) in detecting a wide range of electrical cable anomalies. All tests and results reported herein were performed at the PNNL Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed. The primary objective of this work was to evaluate the effectiveness of SSTDR, a fledgling cable monitoring technique that shows promise for application in online monitoring of energized cable systems, against FDR, an offline technique widely employed in the nuclear power plant (NPP) industry. FDR tests are becoming more widely used in nuclear power plant cable aging management and test programs – particularly for low voltage cables. FDR capabilities for these kinds of tests have been reported by PNNL and others. The FDR test is performed on de-energized cables by connecting the FDR instrument to two of the cable conductors, or one conductor and the shield. A broad band low voltage (< 5 V) chirp is introduced in the cable, and any reflected response is captured in the frequency domain. The captured reflection is then processed by performing an inverse Fourier transform to a time domain response which can then be converted to a distance response based on the cable velocity of propagation (VoP). SSTDR measurements are functionally similar to FDR measurements in that a broad-band voltage signal composed of a square or sine wave modulated pseudo-random sequence of chips (< 5 volts), is injected onto one of the cable conductors. The injected signal will experience partial energy reflection and transmission at each impedance discontinuity along the transmission line. Any reflected response is detected by computing a cross-correlation between the reflected signals and a delayed copy of the incident SSTDR signal. the time delay for the reflected signal to experience the best matched correlation with the incident signal, indicates the travel time for the signal to reach a change in impedance. By knowing this time delay and velocity of propagation (VoP) of the signal, one can compute the physical distance. A big advantage that SSTDR measurements have over other methods is the ability to be connected to energized or live wires (currently up to 1kV) thereby enabling online monitoring of cables. SSTDR has been used successfully in several applications, e.g., aircraft, rail, and photovoltaic systems. In this work FDR and SSTDR cable assessment techniques were used to characterize a variety of cable anomalies and faults including: (1) Presence or absence of a motor; (2) Ground faults and short circuit faults; (3) Moist environments and water ingress faults; (4) Accelerated thermal aging. Both shielded and non-shielded cables were evaluated in this report. Offline measurements were made using FDR and online measurements were made by SSTDR for a range of test scenarios. Based on the results across all cable anomalies evaluated in this study, FDR displayed high sensitivity towards cable condition assessment, while SSTDR showed promise for future application in monitoring NPP cable systems. However, further developments are suggested to improve the resolution and sensitivity of SSTDR towards faults and anomalies in low voltage cables.rt presents a comparative

42 ENGINEERING↗

Upgrading Biogas through in situ Conversion of Carbon Dioxide to Biomethane in Anaerobic Digesters

Organic waste streams generated by wastewater treatment plants, agricultural operations, and food processing industries represent an important yet underutilized opportunity for renewable energy production in the United States. Through anaerobic digestion, these waste streams can produce biogas, a mixture primarily composed of methane (CH4) and carbon dioxide (CO2), that can be upgraded to pipeline-quality natural gas. However, most existing upgrading technologies remove CO2 from biogas rather than utilizing it, leaving a significant portion of the potential energy unused. This project investigates a novel biological upgrading approach that converts CO2 into additional CH4 by supplying hydrogen (H2) to specialized microorganisms capable of performing hydrogenotrophic methanation. The main challenges associated with biological biogas upgrading are related to hydrogen supply, gas-liquid mass transfer, and process stability. First, due to the high cost of hydrogen gas, it is preferable that H2 be produced on-site using renewable energy sources such as wind or solar power. Second, hydrogen has low solubility in liquids, which limits its availability to microorganisms and requires strategies to improve gas dissolution and transfer within the reactor. Third, process inhibition may occur as a result of increased pH caused by CO2 consumption or elevated H2 partial pressure, both of which can negatively affect methanogenic activity. Although research in these areas has advanced during the course of this project, these challenges have not yet been fully resolved. To date, the biological systems that have achieved the highest methane concentrations are typically ex-situ reactors, where operational conditions can be more easily controlled. For this reason, the findings of the present project remain highly relevant. The project goal was to develop an innovative system that can accomplish biogas upgrading via biological conversion of CO2 to CH4, in a novel hybrid approach that combines the advantages of both in-situ and ex-situ systems. The proposed system employs a three-phase upflow anaerobic bioreactor with H2 delivery through a gas-permeable membrane, enabling efficient hydrogen transfer and microbial conversion. Under optimized operating conditions, the system achieved 99% H2 consumption and 90% CO2 conversion. A subsequent gas cleaning stage was implemented to further improve gas quality and meet target purity standards. The upgraded gas composition reached 97.7% CH4, 2.2% CO2, and 0.97% O2, while H2S concentrations remained below detection limits. In addition, a flue gas-driven inorganic thermoelectric generator (TEG) system was designed and experimentally validated as a potential source of electricity for H2 production. The system consisted of six TEG modules connected in series and achieved an open-circuit voltage of 4.5 V and a maximum power output of 224 mW at a temperature difference of approximately 53.5 °C, demonstrating effective conversion of waste heat into electrical power under simulated flue gas conditions. Finally, a comprehensive techno-economic analysis was completed to evaluate the capital and operating costs associated with the proposed system. The results provide important insights to guide future scale-up, optimization, and potential deployment of integrated biological biogas upgrading technologies.

09 BIOMASS FUELS↗

Improved Performance of Cu(InGa)(SeS) 2 PV Modules Using the Reaction of Metal Precursors. Final Report

This project “Improved Performance of Cu(InGa)(SeS) 2 PV Modules using the Reaction of Metal Precursors” was a partnership led by the Institute of Energy Conversion (IEC) at the University of Delaware with Columbia University and the Molecular Foundry at the Lawrence Berkeley National Laboratory. The aim was to develop pathways to improve Cu(InGa)(SeS) 2 (CIGSS) thin film photovoltaic modules using processes compatible with low manufacturing cost. The CIGSS approach investigated was a two-step process including deposition of metal precursor films following by reaction in hydride gases utilizing IEC’s novel reactor. The process was similar to that under commercial development by the project’s industry partner Stion. When Stion went out of business mid-project the focus changed to a rapid thermal process considered more commercially viable. Approaches to improve the performance of solar cells using the reacted films focused on two material innovations. First, the overall Ga content was increased to increase the operating voltage, which is desirable for scale-up to commercial modules. Second, the processing and performance advantages arising from Ag alloying were investigated. Advanced characterization guided process and material development including control of relative composition gradients. Research on the formation of Cu-Ga-In metal precursors utilized sputtering deposition which is normally used in commercial applications. The work resulted in processes for deposition of precursor stacks with increased relative Ga content and effects of deposition parameters on morphology and phase composition were established. It was shown that the metal precursor films have comparable phase composition and morphology so subsequent reaction follows from the same starting point. The addition of Ag to the metal precursors gave more uniform morphology and improved adhesion of reacted films which enable higher reaction temperature for faster processing. A novel outcome was the discovery of a previously undocumented material phase in sputter-deposited and evaporated Ag-Cu-In-Ga thin films. Hydride gas reaction processes including time-temperature-concentration profiles were developed for different precursor compositions. This enables control of composition profiles to engineer through-film gradients for solar cell optimization with characterization and simulations used to correlate measured film composition profiles to measurements of devices. In particular, the gradient of sulfur at the front of the CIGSS film was found to be critical. The simulations guided process development leading to improved reproducibility of devices improved performance with higher Ga content and higher voltage. With Ag-alloyed precursors, the reaction pathways leading were determined. A significant finding was that Ag-alloying increases the reaction rate to completely convert precursor films to the final chalcopyrite which could enable reduced reaction time to benefit manufacturability. To maintain potential commercial viability, the process under investigation was refocused to a rapid thermal process that could potentially be incorporated into an in-line process for manufacturing. Precursors with different composition were capped with an extra selenium layer and reacted in hydrogen sulfide 5-15 minutes, compared to typically 2 hours in the previous multi-step batch process. Critical RTP parameters were identified to control the reaction. Further optimization would be needed for high efficiency solar cells but pathways to high quality devices with further optimization and improved heating uniformity were developed. The project also developed new optoelectronic characterization approaches with a focus on development and application of spatial- and time-resolved photoluminescence and a custom mapping photoluminescence microscope built. It was shown how critical electronic transport properties strongly depend on the chemical composition of the material and that a wide range of samples show inhomogeneity on a length scale larger than the grains in the films. Additionally, two-photon excitation capability was developed to distinguish bulk vs surface losses. The project advances the state-of-the -art for precursor reaction processes in several ways that could impact manufacturing. This includes validation of approaches to increase voltage and establishment of model-guided control to form optimal composition profiles. The application of process control approaches with knowledge of phase formation and reaction pathways can be critically valuable in designing a large-scale process.

14 SOLAR ENERGY↗

Hardware in the Loop Testing of an Iodine-Fed Hall Thruster

CUBESATS are relatively new spacecraft platforms that are typically deployed from a launch vehicle as a secondary payload,1 providing low-cost access to space for a wide range of end-users. These satellites are comprised of building blocks having dimensions of 10x10x10 cm cu and a mass of 1.33 kg (a 1-U size). While providing low-cost access to space, a major operational limitation is the lack of a propulsion system that can fit within a CubeSat and is capable of executing high delta v maneuvers. This makes it difficult to use CubeSats on missions requiring certain types of maneuvers (i.e. formation flying, spacecraft rendezvous). Recently, work has been performed investigating the use of iodine as a propellant for Hall-effect thrusters (HETs) 2 that could subsequently be used to provide a high specific impulse path to CubeSat propulsion. Iodine stores as a dense solid at very low pressures, making it acceptable as a propellant on a secondary payload. It has exceptionally high ρIsp (density times specific impulse), making it an enabling technology for small satellite near-term applications and providing the potential for systems-level advantages over mid-term high power electric propulsion options. Iodine flow can also be thermally regulated, subliming at relatively low temperature ( less than100 C) to yield I2 vapor at or below 50 torr. At low power, the measured performance of an iodine-fed HET is very similar to that of a state-of-the-art xenon-fed thruster. Just as importantly, the current-voltage discharge characteristics of low power iodine-fed and xenon-fed thrusters are remarkably similar, potentially reducing development and qualifications costs by making it possible to use an already-qualified xenon-HET PPU in an iodine-fed system. Finally, a cold surface can be installed in a vacuum test chamber on which expended iodine propellant can deposit. In addition, the temperature doesn't have to be extremely cold to maintain a low vapor pressure in the vacuum chamber (it is under 10(exp -6) torr at -75 C), making it possible to 'cryopump' the propellant with lower-cost recirculating refrigerant-based systems as opposed to using liquid nitrogen or low temperature gaseous helium cryopanels. In the present paper, we describe testing performed using an iodine-fed 200 W Hall thruster mounted to a thrust stand and operated in conjunction with MSFCs Small Projects Rapid Integration and Test Environment (SPRITE) Portable Hardware In the Loop (PHIL) hardware. This work is performed in support of the iodine satellite (iSAT) project, which aims to fly a 200-W iodine-fed thruster on a 12-U CubeSat. The SPRITE PHIL hardware allows a given vehicle to do a checkout of its avionics algorithm by allowing it to monitor and feed data to simulated sensors and effectors in a digital environment. These data are then used to determine the attitude of the vehicle and a separate computer is used to interpret the data set and visualize it using a 3D graphical interface. The PHIL hardware allows the testing of the vehicles bus by providing 'real' hardware interfaces (in the case of this test a real RS422 bus) and specific components can be modeled to show their interactions with the avionics algorithm (e.g. a thruster model). For the iSAT project the PHIL is used to visualize the operating cycle of the thruster and the subsequent effect this thrusting has on the attitude of the satellite over a given period of time. The test is controlled using software running on an Andrews Space Cortex 160 flight computer. This computer is the current baseline for a full iSAT mission. While the test could be conducted with a lab computer and software, the team chose to exercise the propulsion system with a representative CubeSat-class computer. For purposes of this test, the "flight" software monitored the propulsion and PPU systems, controlled operation of the thruster, and provided thruster state data to the PHIL simulation. Commands to operate the thruster were initiated from an operator's workstation outside the vacuum chamber and passed through the Cortex 160 to exercise portions of the flight avionics. Two custom-designed pieces of electronics hardware have been designed to operate the propellant feed system. One piece of hardware is an auxiliary board that controls a latch valve, proportional flow control valves (PFCVs) and valve heaters as well as measuring pressures, temperatures and PFCV feedback voltage. An onboard FPGA provides a serial link for issuing commands and manages all lower level input-output functions. The other piece of hardware is a power distribution board, which accepts a standard bus voltage input and converts this voltage into all the different current-voltage types required to operate the auxiliary board. These electronics boards are located in the vacuum chamber near the thruster, exposing this hardware to both the vacuum and plasma environments they would encounter during a mission, with these components communicating to the flight computer through an RS-422 interface. The auxiliary board FPGA provides a 28V MOSFET switch circuit with a 20ms pulse to open or close the iodine propellant feed system latch valve. The FPGA provides a pulse width modulation (PWM) signal to a DC/DC boost converter to produce the 12-120V needed for control of the proportional flow control valve. There are eight MOSFET-switched heating circuits in the system. Heaters are 28V and located in the latch valve, PFCV, propellant tank and propellant feed lines. Both the latch valve and PFCV have thermistors built into them for temperature monitoring. There are also seven resistance temperature device (RTD) circuits on the auxiliary board that can be used to measure the propellant tank and feedline temperatures. The signals are conditioned and sent to an analog to digital converter (ADC), which is directly commanded and controlled by the FPGA.

Polzin, Kurt A.↗