Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dark radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Comprehensive study of radon progeny attachment to surfaces

Low energy, low rate experiments, such as searches for neutrinoless double β decay and dark matter, require unprecedentedly low levels of background in order to deliver their full science potential. 210 Po driven, neutron induced background, caused by nuclear (α, n) reactions on low-Z materials, direct background contributions of the 210 Po α radiation and desorption of the 210 Pb progeny 210 Bi from surfaces into the detector medium are of particular of concern. These backgrounds depend on details of the components’ exposure to radon-loaded laboratory air and, thus, their handling history. The attachment rates of airborne radon progeny to surfaces, needed for the estimation of these background rates, are poorly understood. This article reports the results of a campaign comprising of more than 1200 attachment measurements, performed for nine different materials. Correlations of the attachment with environmental parameters such as air exchange rate, electrical surface potential, temperature, atmospheric pressure, and relative humidity have been studied and found to be significant only in case of the first two. Attachment modeling, using the Jacobi model, is compared to data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Interference with gravitational instability: Hot and fuzzy dark matter

Wave or fuzzy dark matter produced with high momenta behaves in many ways like hot particle dark matter while also possessing seemingly different phenomenology due to wave interference. We develop wave perturbation theory to show that white noise density fluctuations generated by the interference of high-momenta waves are gravitationally unstable in the usual way during matter domination above the free-streaming scale and stabilize below the free-streaming scale, much like the analogous effects for massive neutrinos in hot dark matter. We verify and illustrate these effects in the density power spectra of Newtonian Schrödinger-Poisson simulations. In the cosmological context, this would cause a gradual suppression of the initial white noise isocurvature perturbations below the free-streaming scale at matter radiation equality, unlike cold dark matter isocurvature fluctuations, and virial stability of dark matter halos.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements and models of enhanced recombination following inner-shell vacancies in liquid xenon

Electron-capture decays of 125 Xe and 127 Xe , and double-electron-capture decays of 124 Xe , are backgrounds in searches for weakly interacting massive particles (WIMPs) conducted by dual-phase xenon time projection chambers such as LUX-ZEPLIN (LZ). These decays produce signals with more light and less charge than equivalent-energy 𝛽 decays and correspondingly overlap more with WIMP signals. We measure three electron-capture charge yields in LZ: the 1.1 keV M-shell, 5.2 keV L-shell, and 33.2 keV K-shell at drift fields of 193 and 96.5 V/cm. The LL double-electron-capture decay of 124 Xe exhibits even more pronounced shifts in charge and light. We provide a first model of double-electron-capture charge yields using the link between ionization density and electron-ion recombination, and identify a need for more accurate calculations. Finally, we discuss the implications of the reduced charge yield of these decays and other interactions creating inner-shell vacancies for future dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation damage in a Tektronix 512 CCD

A Tektronix CCD was subjected to a proton beam. Comparisons were made of the CCD characteristics before, during, and after radiation. Gain and readout noise were not affected and charge transfer efficiency, full well, and dark current were. Permanent CTE damage resulted immediately upon radiation, but full well damage developed two days after radiation, while the dark current showed signs of recovery before permanent damage occurred. Histogram analysis showed that the most spiky-type behavior resulted from damage to defects existing in the CCD before radiation.

Brown, Larry W.↗

Nonlocal effects from boosted dark matter in indirect detection

Here, indirect dark matter (DM) detection typically involves the observation of standard model (SM) particles emerging from DM annihilation/decay inside regions of high dark matter concentration. We consider an annihilation scenario in which this reaction has to be initiated by one of the DMs involved being boosted while the other is an ambient nonrelativistic particle. This “trigger” DM must be created, for example, in a previous annihilation or decay of a heavier component of DM. Remarkably, boosted DM annihilating into gamma rays at a specific point in a galaxy could actually have traveled from its source at another point in the same galaxy or even from another galaxy. Such a “nonlocal” behavior leads to a nontrivial dependence of the resulting photon signal on the galactic halo parameters, such as DM density and core size, encoded in the so-called “astrophysical” J-factor. These nonlocal J-factors are strikingly different than the usual scenario. A distinctive aspect of this model is that the signal from dwarf galaxies relative to the Milky Way tends to be suppressed from the typical value to various degrees depending on their characteristics. This feature can thus potentially alleviate the mild tension between the DM annihilation explanation of the observed excess of approximately GeV photons from the Milky Way’s Galactic Center vs the apparent nonobservation of the corresponding signal from dwarf galaxies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Large mass single electron resolution detector for dark matter and neutrino elastic interaction searches

Large mass single electron resolution solid state detectors are desirable to search for low mass dark matter candidates and to measure coherent elastic neutrino nucleus scattering (CEvNS). In this paper we present results from a novel 100 g phonon-mediated Si detector with a new interface architecture. This detector gives a baseline resolution of ~ 1e - /h + pair and a leakage current on the order of 10 -16 A. This was achieved by removing the direct electrical contact between the Si crystal and the metallic electrode, and by increasing the phonon absorption efficiency of the sensors. The phonon signal amplification in the detector shows a linear increase while the signal to noise ratio improves with bias voltage, up to 240 V. This feature enables the detector to operate at a low energy threshold which is beneficial for dark matter and CEvNS like searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton irradiation damage and annealing effects in ON Semiconductor J-series silicon photomultipliers

Silicon photomultipliers (SiPMs) have become popular light conversion devices in recent years due to their low bias voltage and sensitivity to wavelengths emitted from common scintillating materials. These properties make them particularly attractive for resource-constrained missions such as space-based detector applications. However, the space radiation environment is known to be particularly harsh on semiconductor devices, where high particle fluences can degrade performance over time. The radiation hardness of a particular SiPM, manufactured by ON Semiconductor (formally SensL), has yet to be studied with high energy protons, which are native to the space radiation environment. As such, to study these effects we have irradiated groups of two SiPMs to four different fluences of 800 MeV protons delivered by the accelerator at the Los Alamos Neutron Science Center. Fluences of 1.68 × 10 9 , 1.73 × 10 10 , 6.91 × 10 10 , and 1.73 × 10 11 protons cm –2 , and their corresponding estimated doses of 0.15, 1.55, 6.19, and 15.5 kRad, were chosen based on estimates of the potential exposure a SiPM might receive during an interplanetary space mission lasting 10 years. We report the effects these doses have on dark current and the self-annealing time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extremely Low Energy Nuclear Recoil Calibrations for Dark Matter Direct Detection (Final Technical Report)

This project developed and demonstrated a new calibration approach for low-energy nuclear recoils in solid-state detectors based on neutron capture. Precise calibration in the sub-keV regime is a critical challenge across the HEP portfolio. Existing measurements show deviations and inconsistencies across methods. Neutron capture provides a complementary approach producing discrete recoils via γ cascades.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reionization of the Universe and the Photoevaporation of Cosmological Minihalos

The first sources of ionizing radiation to condense out of the dark and neutral Intergalactic Medium (IGM) sent ionization fronts sweeping outward through their surroundings, overtaking other condensed objects and photoevaporating them. This feedback effect of universal reionization on cosmic structure formation is demonstrated here for the case of a cosmological minihalo of dark matter and baryons exposed to an external source of ionizing radiation with a quasar-like spectrum, just after the passage of the global ionization front created by the source. We model the pre-ionization minihalo as a truncated, nonsingular isothermal sphere in hydrostatic equilibrium following its collapse out of the expanding background universe and virialization. Results are presented of the first, gas dynamical simulations of this process, including radiative transfer. A sample of observational diagnostics is also presented, including the spatially-varying ionization levels of C, N, and O in the flow if a trace of heavy elements is present and the integrated column densities of H I, He I and He II, and C IV through the photoevaporating gas at different velocities, which would be measured in absorption against a background source like that responsible for the ionization.

Shapiro, Paul R.↗

Cosmogenic activation of silicon

In the production of 3 H, 7 Be, and 22 Na by interactions of cosmic-ray particles with silicon can produce radioactive backgrounds in detectors used to search for rare events. Through controlled irradiation of silicon CCDs and wafers with a neutron beam that mimics the cosmic-ray neutron spectrum, followed by direct counting, we determined that the production rate from cosmic-ray neutrons at sea level is (112 ± 24) atoms/( kg day ) for 3 H, (8.1 ± 1.9) atoms/( kg day ) for 7 Be, and (43.0 ± 7.2) atoms/( kg day ) for 22 Na . Complementing these results with the current best estimates of activation cross sections for cosmic-ray particles other than neutrons, we obtain a total sea-level cosmic-ray production rate of (124 ± 25) atoms/(kg day) for 3 H, (9.4 ± 2.0) atoms/( kg day ) for 7 Be, and (49.6 ± 7.4) atoms/( kg day ) for 22 Na. These measurements will help constrain background estimates and determine the maximum time that silicon-based detectors can remain unshielded during detector fabrication before cosmogenic backgrounds impact the sensitivity of next-generation rare-event searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Massive, Position-Resolving, High-Energy-Resolution Detector for Non-Accelerator Cosmic and Intensity Frontier Particle Physics

We proposed to take the first steps in the development of a detector that promises energy resolution of tens of eV FWHM combined with robust nuclear-recoil discrimination and high fidelity, mm-precision position reconstruction for applications in non-accelerator particle physics at the Cosmic and Intensity Frontiers. The detector would obtain these excellent resolutions by sensing athermal phonons produced by particle interactions in crystalline, dielectric targets using a sensitive, highly multiplexable superconducting phonon sensor, the kinetic inductance detector (KID). This detector would be applicable to: the search for low-mass particle dark matter candidates with masses below 5~GeV via direct detection of scattering of dark matter particles with terrestrial nuclei; detection of coherent elastic neutrino-nucleus scattering to test for new physics such as a non-standard value of the weak nuclear charge, non-standard neutrino interactions (perhaps driven by a neutrino magnetic moment), or the existence of sterile neutrinos; and, searches for neutrinoless double-beta decay. During the funding period, we demonstrated scaling up of the detector concept from a 22-mm by 22-mm by 1-mm, 1-g prototype with 0.9~keV FWHM energy resolution to a 75-mm diameter by 1-mm, 9-g prototype while improving the inferred energy resolution to 0.7~keV~FWHM. In the process, we solved many problems associated with scaling device fabrication to large wafers and vastly reduced the fraction of the surface occupied by inactive but energy-absorbing metal. We also demonstrated a new technique that substantially simplifies the process of characterizing a new detector. These results provide a good foundation for future work scaling up the design to 4-mm thickness substrates and improving the resolution to reach 0.035~keV~FWHM, yielding a detector with compelling potential for the above applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C 3 F 8 dark matter detectors

The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. Here, the PICO collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C 3 F 8 from calibration data taken with five distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov chain Monte Carlo routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be ≥ 50% for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be ≥ 50% for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated datasets are used to calculate a p value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nucleus capture by macroscopic dark matter

For a class of macroscopic dark matter with a large interaction strength with Standard Model particles, a nucleus could be captured by the dense, heavy dark matter as it traverses ordinary material. The radiated photon carries most of the binding energy and is a characteristic signature for dark matter detection. We develop analytic formulas and present numerical results for this radiative capture process in the low energy, non-dipole limit. Large-volume neutrino detectors like NOνA, JUNO, DUNE and Super(Hyper)-K may detect multi-hit or single-hit radiative capture events and can search for dark matter up to one gram in mass.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensitivity of the NEXT experiment to Xe-124 double electron capture

Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture (2$\nu$EC EC) has been predicted for a number of isotopes, but only observed in 78 Kr, 130 Ba and, recently, 124 Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process, 0$\nu$EC EC. Here we report on the current sensitivity of the NEXT-White detector to 124 Xe 2$\nu$EC EC and on the extrapolation to NEXT-100. Using simulated data for the 2$\nu$EC EC signal and real data from NEXT-White operated with 124 Xe-depleted gas as background, we define an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of 124 Xe and for a 5-year run, a sensitivity to the 2$\nu$EC EC half-life of 6 × 10 22 y (at 90% confidence level) or better can be reached.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boosting background suppression in the NEXT experiment through Richardson-Lucy deconvolution

Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~ 10 27 yr, requiring suppressing backgrounds to < 1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy resolution and the use of extremely radiopure materials, is of utmost importance. The NEXT experiment exploits differences in the spatial ionization patterns of double beta decay and single-electron events to discriminate signal from background. While the former display two Bragg peak dense ionization regions at the opposite ends of the track, the latter typically have only one such feature. Thus, comparing the energies at the track extremes provides an additional rejection tool. The unique combination of the topology-based background discrimination and excellent energy resolution (1% FWHM at the Q-value of the decay) is the distinguishing feature of NEXT. Previous studies demonstrated a topological background rejection factor of ~ 5 when reconstructing electron-positron pairs in the 208Tl 1.6 MeV double escape peak (with Compton events as background), recorded in the NEXT-White demonstrator at the Laboratorio Subterráneo de Canfranc, with 72% signal efficiency. This was recently improved through the use of a deep convolutional neural network to yield a background rejection factor of ~ 10 with 65% signal efficiency. Here, we present a new reconstruction method, based on the Richardson-Lucy deconvolution algorithm, which allows reversing the blurring induced by electron diffusion and electroluminescence light production in the NEXT TPC. The new method yields highly refined 3D images of reconstructed events, and, as a result, significantly improves the topological background discrimination. When applied to real-data 1.6 MeV e - e + pairs, it leads to a background rejection factor of 27 at 57% signal efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of a tonne-scale NEXT detector for neutrinoless double-beta decay searches

The Neutrino Experiment with a Xenon TPC (NEXT) searches for the neutrinoless double-beta (0νββ) decay of 136 Xe using high-pressure xenon gas TPCs with electroluminescent amplification. A scaled-up version of this technology with about 1 tonne of enriched xenon could reach in less than 5 years of operation a sensitivity to the half-life of 0νββ decay better than 10 27 years, improving the current limits by at least one order of magnitude. This prediction is based on a well-understood background model dominated by radiogenic sources. The detector concept presented here represents a first step on a compelling path towards sensitivity to the parameter space defined by the inverted ordering of neutrino masses, and beyond.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of neutrinoless double beta decay searches in gaseous xenon with NEXT

The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in 136 Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterráneo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means of the topology of the reconstructed tracks, NEXT-White has been exploited beyond its original goals in order to perform a neu- trinoless double beta decay search. The analysis considers the combination of 271.6 days of 136 Xe-enriched data and 208.9 days of 136Xe-depleted data. A detailed background modeling and measurement has been developed, ensuring the time stability of the radiogenic and cosmogenic contributions across both data samples. Limits to the neutrinoless mode are obtained in two alternative analyses: a background-model-dependent approach and a novel direct background-subtraction technique, offering results with small dependence on the background model assumptions. With a fiducial mass of only 3.50 ± 0.01 kg of 136 Xe-enriched xenon, 90% C.L. lower limits to the neutrinoless double beta decay are found in the $T^{0v}_{1/2} > 5.5 \times 10^{23} - 1.3 \times 10^{24}$ yr range, depending on the method. The presented techniques stand as a proof-of-concept for the searches to be implemented with larger NEXT detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Removal of 210 Pb by etch of crystalline detector sidewalls

A potential source of dominant backgrounds for many rare-event searches or screening detectors is from radon daughters, specifically 210 Pb, deposited on detector surfaces, often during detector fabrication. Performing a late-stage etch is challenging because it may damage the detector. Here, this paper describes a late-stage etching technique that reduces surface 210 Pb and 210 Po by > 99x at 90% C.L.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗