Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Verifying X-Radiographs With Computed Tomographs

Nondestructive technique gives added confidence in inspection. Ambiguous indications in radiographic inspections of metal castings checked by computed tomography. Fast and inexpensive conventional x-ray inspection used to make film image of overall casting, and slower, more costly computed tomography used to reinspect relatively few parts of casting presenting possible diffraction patterns or other difficult-to-interpret features. Method effective in resolving ambiguities in radiographs of turbine blades. Provides same information as metallurgical sectioning.

Roy, Jagatjit↗

Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction

This paper presents a new reconstruction algorithm for both single- and dual-energy computed tomography (CT) imaging. By incorporating the polychromatic characteristics of the X-ray beam into the reconstruction process, the algorithm is capable of eliminating beam hardening artifacts. The single energy version of the algorithm assumes that each voxel in the scan field can be expressed as a mixture of two known substances, for example, a mixture of trabecular bone and marrow, or a mixture of fat and flesh. These assumptions are easily satisfied in a quantitative computed tomography (QCT) setting. We have compared our algorithm to three commonly used single-energy correction techniques. Experimental results show that our algorithm is much more robust and accurate. We have also shown that QCT measurements obtained using our algorithm are five times more accurate than that from current QCT systems (using calibration). The dual-energy mode does not require any prior knowledge of the object in the scan field, and can be used to estimate the attenuation coefficient function of unknown materials. We have tested the dual-energy setup to obtain an accurate estimate for the attenuation coefficient function of K2 HPO4 solution.

NASA Center ARC↗

The Inside View

Bio-Imaging Research, Inc., has been included in Spinoff 1990 and 1993 with spinoffs from their ACTIS (Advanced Computed Tomography Inspection System) product developed under a Marshall Space Flight Center SBIR (Small Business Innovative Research) contract. The latest application is for noninvasive nuclear waste drum inspection. With the ACTIS CT (computed tomography, CATScan) scanner, radioactive waste is examined to prove that they do not contain one-half percent free liquid or that the drum wall has lost integrity before being moved across state lines or before being permanently disposed.

Source record↗

1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings

The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.

Source record↗

Non-Invasive Investigation of Bone Adaptation in Humans to Mechanical Loading

Experimental studies have identified peak cyclic forces, number of loading cycles, and loading rate as contributors to the regulation of bone metabolism. We have proposed a theoretical model that relates bone density to a mechanical stimulus derived from average daily cumulative peak cyclic 'effective' tissue stresses. In order to develop a non-invasive experimental model to test the theoretical model we need to: (1) monitor daily cumulative loading on a bone, (2) compute the internal stress state(s) resulting from the imposed loading, and (3) image volumetric bone density accurately, precisely, and reproducibly within small contiguous volumes throughout the bone. We have chosen the calcaneus (heel) as an experimental model bone site because it is loaded by ligament, tendon and joint contact forces in equilibrium with daily ground reaction forces that we can measure; it is a peripheral bone site and therefore more easily and accurately imaged with computed tomography; it is composed primarily of cancellous bone; and it is a relevant site for monitoring bone loss and adaptation in astronauts and the general population. This paper presents an overview of our recent advances in the areas of monitoring daily ground reaction forces, biomechanical modeling of the forces on the calcaneus during gait, mathematical modeling of calcaneal bone adaptation in response to cumulative daily activity, accurate and precise imaging of the calcaneus with quantitative computed tomography (QCT), and application to long duration space flight.

Whalen, R.↗

Petrology, Geochemistry, and Pairing of Lunar Meteorites from the Dominion Range

Introduction: During the 2018-2019 Antarctic Search for Meteorites (ANSMET) field season in the Dominion Range (DOM), 7 lunar meteorite stones were collected: DOM 18242 (15.1 g), DOM 18244 (25.1 g), DOM 18262 (6.8 g), DOM 18509 (16.5 g), DOM 18543 (13.6 g), DOM 18666 (45.9 g), and DOM 18678 (11.6 g). Here we present the initial results of electron microprobe and X-ray computed tomography (XCT) studies of these stones and look at the details of their petrography and mineral chemistry, as well as investigate possible pairing relationships, both with each other and with previously described lunar meteorites. Most of the work presented here is on the DOM 18509, 18543, and 18678 stones; subsamples of the other stones are in hand and similar measurements will be made on them by the time of the meeting. Methods: Textures in DOM 18509, DOM 18543, and DOM 18678 were characterized in 2D by optical microscopy, backscattered electron (BSE) imaging and elemental X-ray images on thin sections, as well as in 3D by X-ray computed tomography (XCT) on sample chips. Mineral compositions were assessed through a combination of wavelength dispersive spectroscopy EPMA (electron probe microanalysis) and x-ray mapping on the JEOL 8530 at NASA JSC. The bulk composition of all three meteorites was determined based on analyses of the fusion crust glass. XCT analyses were done on the Nikon XTH 320 at NASA JSC. ICP-MS data on bulk rock subsamples for each meteorite will be carried out in the near future. Results: The stones are all similar in macroscopic appearance with a dark aphanitic matrix hosting a variety of small- to medium-sized angular mineral and lithic fragments (often light colored in nature) [1,2]. Based on EPMA and XCT results, the three meteorites are polymict regolith breccias comprised of mineral, glass, and lithic clasts ranging up to several mm in length. Melt veins run through all three meteorite samples. Mineral clasts in all 3 stones are dominated by pyroxene and plagioclase (An82-96), with minor amounts of SiO2, olivine (Fo1-52), and FeTi-oxides. Pyroxene grains are mostly Fe-rich pigeonite and augite, and larger clasts are normally zoned and have fine exsolution lamellae. The lithic clasts in all stones consists of: (1) basalt clasts that contain zoned pyroxene, plagioclase laths, and ilmenite, with minor silica and Fe-rich olivine; (2) granulitic clasts; (3) anorthosite clasts; (4) Si-rich clasts that also contain ilmenite, troilite, high-Ca pyroxene, fayalite, and K-feldspar likely mesostasis from late stage basalts). All three meteorites contain glassy fusion crust that is highly vesicular, high in FeO and Al2O3 (15-17 wt% each), ferroan (Mg# of 23-24), and moderately rich in TiO2 (1.4-1.8 wt%). The composition of the fusion crust can serve as a proxy for the bulk meteorite composition and is identical within error for all three meteorites. Implications: The lithic and mineral clasts in all three stones are similar in clast population and assemblages as well as mineral chemistry. In addition, the fusion crust composition, a proxy for bulk composition, is within error of each other for all three stones. Thus DOM 18509, DOM 18543, and DOM 18678 are almost certainly paired. Based on similarities in macroscopic description as well as preliminary classification data [1,2], all 7 lunar stones from DOM are likely paired, though additional quantitative analyses are needed to confirm this. The presence of spherules and vesicular fusion crusts indicates that the DOM pairing group is a regolith breccia. The presence of basaltic and gabbroic clasts as well as more feldspathic materials, suggest that the regolith from which these meteorites formed contained a mixture of feldspathic highland material and mare material, suggesting a possible provenance near a marehighlands boundary. No evidence of KREEPy lithologies have been observed so far in these meteorites, however, future ICP-MS data on bulk rock chips for the stones will reveal any KREEP component if present. The DOM pairing group has many similarities to previously described lunar breccia meteorite MET 01210, however more detailed compositional data will be needed to make a definitive comparison.

R.A. Zeigler↗

Assessment of Internal Fabric of Particulate Materials

Particle arrangement and distribution within a soil matrix has long been recognized as having significant influence on the mechanical behavior of cohesionless soils. It is well known that two soil specimens having the same grain type (e.g., quartz, feldspar, etc.), same grain size distribution and relative density (or void ratio) can display completely different mechanical behavior. Because of the different fabric configurations in the otherwise similar specimens, they are likely to have different mechanical properties such as stress-strain response, anisotropy, dilatancy, etc. Soil Fabric is defined as the arrangement of particles, particle groups and associated pore space. In the literature, fabric analysis techniques are mainly classified as destructive (e.g., specimen stabilization, thin-sectioning, and microscopy), and nondestructive techniques (e.g., magnetic resonance imaging, ultrasonic testing, x-ray radiography, and computed tomography). Quantifying the void ratio and its distribution is the main parameter used to describe the fabric of particulate materials. This paper presents a comprehensive literature review of fabric analysis techniques applied to particulate materials. In addition, the results of a comprehensive investigation to quantify void ratio of sand specimens will be presented and discussed. The sand used in the experiments in a natural, uniform rounded to sub-rounded silica sand known as F-75 banding sand with mean particle size of 0.22 mm. Uniform specimens and specimens subjected to different axial-strain levels tested under triaxial and biaxial conditions are examined to evaluate void ratio evolution and its distribution using destructive thin-sectioning and nondestructive Computed Tomography (CT) techniques. Details of a new innovative polygon generation technique called Voronoi tessellation used to quantify void ratio of microscopic images of sand grains will be presented and compared to classical Oda's method. Finally, frequency distribution of void ratio calculated using CT analysis will be presented and discussed.

Alshibi, Khalid A.↗

Structural Anomalies Detected in Ceramic Matrix Composites Using Combined Nondestructive Evaluation and Finite Element Analysis (NDE and FEA)

Most reverse engineering approaches involve imaging or digitizing an object and then creating a computerized reconstruction that can be integrated, in three dimensions, into a particular design environment. The rapid prototyping technique builds high-quality physical prototypes directly from computer-aided design files. This fundamental technique for interpreting and interacting with large data sets is being used here via Velocity2 (an integrated image-processing software, ref. 1) using computed tomography (CT) data to produce a prototype three-dimensional test specimen model for analyses. A study at the NASA Glenn Research Center proposes to use these capabilities to conduct a combined nondestructive evaluation (NDE) and finite element analysis (FEA) to screen pretest and posttest structural anomalies in structural components. A tensile specimen made of silicon nitrite (Si3N4) ceramic matrix composite was considered to evaluate structural durability and deformity. Ceramic matrix composites are being sought as candidate materials to replace nickel-base superalloys for turbine engine applications. They have the unique characteristics of being able to withstand higher operating temperatures and harsh combustion environments. In addition, their low densities relative to metals help reduce component mass (ref. 2). Detailed three-dimensional volume rendering of the tensile test specimen was successfully carried out with Velocity2 (ref. 1) using two-dimensional images that were generated via computed tomography. Subsequent, three-dimensional finite element analyses were performed, and the results obtained were compared with those predicted by NDE-based calculations and experimental tests. It was shown that Velocity2 software can be used to render a three-dimensional object from a series of CT scan images with a minimum level of complexity. The analytical results (ref. 3) show that the high-stress regions correlated well with the damage sites identified by the CT scans and the experimental data. Furthermore, modeling of the voids collected via NDE offered an analytical advantage that resulted in more accurate assessments of the material s structural strength. The top figure shows a CT scan image of the specimen test section illustrating various hidden structural entities in the material and an optical image of the test specimen considered in this study. The bottom figure represents the stress response predicted from the finite element analyses (ref .3 ) for a selected CT slice where it clearly illustrates the correspondence of the high stress risers due to voids in the material with those predicted by the NDE. This study is continuing, and efforts are concentrated on improving the modeling capabilities to imitate the structural anomalies as detected.

Abdul-Aziz, Ali↗

Mineralogical, Elemental and Tomographic Reconnaissance Investigation for CLPS (“METRIC”)

METRIC comprises a suite of two instruments in a Lunar lander that perform X-ray diffraction (XRD) for mineral structure, X-ray fluorescence (XRF) for elemental composition, and X-ray Micro Computed Tomography (XCT) for 3D internal micromorphology. The instruments are accompanied by optical-near IR cameras to provide local geologic context. The Honeybee Robotics PlanetVac pneumatic sampling and transfer system [1],positioned on a lander footpad, will deliver sieved regolith to the X-ray instruments for analysis. The instrument suite is intended for delivery to the lunar surface on a Commercial Lunar Payload Services (CLPS) lander. The METRICXRD/F instrument draws on heritage from the Mars Science Laboratory CheMin instrument [2] and improves upon the design in multiple ways [3]. Like CheMin, Rietveld refinement and full-pattern fitting of METRIC XRD data can identify minerals at a detection limit of ~1 wt.%, quantify their abundances when present at >3 wt.%, and determine mineral composition (e.g., Fo#in olivine) from lattice parameters for minerals present at >5 wt.%[4,5]. An optimized XRF geometry provides for improved detection and quantification of major, minor and trace elements. The METRIC XCT instrument is a miniaturized X-ray Computed Tomography scanner[6]. Lunar regolith is delivered to a 3 mm diameter, 10 mm long graphite tube inside the instrument. The tube is rotated through 360°in 0.9deg.incrementsand a divergent point source X-ray beam is directed through the material. A Charge Coupled Device (CCD)records attenuation images whose brightness and contrast area function of average atomic number and density. Quantitative data, including particle and void sizes, 3D particle shape parameters, modal volumes and pore geometry can be derived from the resulting 3D reconstructions(voxel resolution: 30 μm). Crystal morphologies derived from METRIC XCT data complement the bulk mineralogy determined by the METRIC XRD/F and provide a measure of grain size distribution for the different phases. Taken together, the METRIC instrument suite determines crystal structure, elemental composition and morphology, three principal characteristics of geological materials that are highly useful in determining the origin and subsequent processing of lunar regolith.

Moon↗

Modeling the Effective Elasticity of Anisotropic Porous Materials

The development and optimization of composite materials designed for thermal protection of NASA’s spacecraft require understanding their physical response to high-enthalpy environments. To predict their macro-scale properties and behavior, high-fidelity 3D simulations are performed at the microscale on realistic representations of these composites. The digital microstructures are generated either synthetically or through X-ray micro-computed tomography reconstructions. One of the main challenges in the prediction of the structural response of heatshield materials is the computation of the effective elasticity of the fibrous composite, as well as the understanding of the deformation and stresses generated at the microscale. These are driven by the fiber layout within the microstructure and the distribution of the infused matrix. In this effort, the micro-mechanical linear elastic behavior of fibrous ablators is modeled using a numerical method based on the Multi-Point Stress Approximation (MPSA) finite volume scheme, a generalization of the more commonly used Multi-Point Flux Approximation (MPFA) that was presented at the 10th Ablation Workshop. To predict the behavior of fibrous and woven architectures, algorithms that compute the local fiber orientation are used. The implementation of the MPSA was verified using analytical solutions, engineering test cases, and compared against legacy Finite Element Analysis (FEA) software. The stress analysis models were then applied to real geometries used by NASA in thermal protection systems such as fibrous preforms and woven materials and the results were compared to experimental data.

Elasticity↗

Predicting Bone Mechanical State During Recovery After Long-Duration Skeletal Unloading Using QCT and Finite Element Modeling

During long-duration missions at the International Space Station, astronauts experience weightlessness leading to skeletal unloading. Unloading causes a lack of a mechanical stimulus that triggers bone cellular units to remove mass from the skeleton. A mathematical system of the cellular dynamics predicts theoretical changes to volume fractions and ash fraction in response to temporal variations in skeletal loading. No current model uses image technology to gather information about a skeletal site s initial properties to calculate bone remodeling changes and then to compare predicted bone strengths with the initial strength. The goal of this study is to use quantitative computed tomography (QCT) in conjunction with a computational model of the bone remodeling process to establish initial bone properties to predict changes in bone mechanics during bone loss and recovery with finite element (FE) modeling. Input parameters for the remodeling model include bone volume fraction and ash fraction, which are both computed from the QCT images. A non-destructive approach to measure ash fraction is also derived. Voxel-based finite element models (FEM) created from QCTs provide initial evaluation of bone strength. Bone volume fraction and ash fraction outputs from the computational model predict changes to the elastic modulus of bone via a two-parameter equation. The modulus captures the effect of bone remodeling and functions as the key to evaluate of changes in strength. Application of this time-dependent modulus to FEMs and composite beam theory enables an assessment of bone mechanics during recovery. Prediction of bone strength is not only important for astronauts, but is also pertinent to millions of patients with osteoporosis and low bone density.

Chang, Katarina L.↗

Development of Computational Materials Workflows for Additively Manufactured Metallic Materials to Enable Accelerated Prediction of Fatigue Performance

The maturation of computational materials approaches for fatigue performance prediction in a qualification and certification process is stifled by the ability to validate complex, microstructure-based simulations. Such a validation strategy bears immediate challenges including generating accurate virtual microstructures, efficiently solving physics-based mechanical simulations over relevant spatial and temporal scales, and acquiring high-fidelity calibration and validation data at the appropriate length scale. This presentation will overview these common challenges and present a case study to demonstrate a computational materials workflow for additively manufactured metallic materials. In this study, process-specific defects are characterized using segmented X-Ray micro-computed tomography measurements and overlaid on virtual microstructures. Accelerated crystal plasticity-based fatigue simulations are performed to demonstrate cyclic evolution and localization of mechanical fields in the vicinity of defects in response to their precise spatial configuration. An example of how this computational materials workflow may support next-generation qualification is discussed.

computational materials↗

Thermal Inspection for the Assessment of Adhesively Bonded Metal Adherends

Certification of adhesively bonded structures is currently a challenge for aircraft manufacturers. The ability to certify bonds in primary structure can reduce dependence on fasteners and this will enable more efficient manufacturing. For example, drilling holes and installing fasteners in bonded joints can be a potentially significant bottleneck in airframe manufacturing. In addition, fasteners increase the airframe weight and can add stress concentration areas. Reducing fastener count can accelerate manufacturing and improve aircraft performance. NASA is currently investigating nondestructive evaluation (NDE) techniques to assess bond integrity. For example, bond thickness influences bond strength and therefore NDE techniques are being investigated to determine bond thickness. For bonded metal structures, there is a large difference in the thermal diffusivity between the 7075 aluminum alloy metal adherends and aircraft grade adhesive. Multi-layered thermal models show a large variation in the thermal response for bondline adhesive thicknesses that vary from 100 to 300 microns for adherend thicknesses of 0.163 cm. Experimental through-transmission thermal measurements reveal promise to quantitatively characterize the bondline thickness. Results were validated with X-ray computed tomography and optical microscopy measurements, and influence of porosity on the thermal model and measurements are investigated.

X-ray computed tomography↗

Baroreflex regulation of blood pressure during dynamic exercise

From the work of Potts et al. Papelier et al. and Shi et al. it is readily apparent that the arterial (aortic and carotid) baroreflexes are reset to function at the prevailing ABP of exercise. The blood pressure of exercise is the result of the hemodynamic (cardiac output and TPR) responses, which appear to be regulated by two redundant neural control systems, "Central Command" and the "exercise pressor reflex". Central Command is a feed-forward neural control system that operates in parallel with the neural regulation of the locomotor system and appears to establish the hemodynamic response to exercise. Within the central nervous system it appears that the HLR may be the operational site for Central Command. Specific neural sites within the HLR have been demonstrated in animals to be active during exercise. With the advent of positron emission tomography (PET) and single-photon emission computed tomography (SPECT), the anatomical areas of the human brain related to Central Command are being mapped. It also appears that the Nucleus Tractus Solitarius and the ventrolateral medulla may serve as an integrating site as they receive neural information from the working muscles via the group III/IV muscle afferents as well as from higher brain centers. This anatomical site within the CNS is now the focus of many investigations in which arterial baroreflex function, Central Command and the "exercise pressor reflex" appear to demonstrate inhibitory or facilitatory interaction. The concept of whether Central Command is the prime mover in the resetting of the arterial baroreceptors to function at the exercising ABP or whether the resetting is an integration of the "exercise pressor reflex" information with that of Central Command is now under intense investigation. However, it would be justified to conclude, from the data of Bevegard and Shepherd, Dicarlo and Bishop, Potts et al., and Papelier et al. that the act of exercise results in the resetting of the arterial baroreflex. In addition, if, as we have proposed, the cardiopulmonary baroreceptors primarily monitors and reflexly regulates cardiac filling volume, it would seem from the data of Mack et al. and Potts et al. that the cardiopulmonary baroreceptor is also reset at the beginning of exercise. Therefore, investigations of the neural mechanisms of regulation involving Central Command and cardiopulmonary afferents, similar to those being undertaken for the arterial baroreflex, need to be established.

NASA Discipline Cardiopulmonary↗

Thermal Inspection for the Assessment of Adhesively Bonded Metal Adherents

Certification of adhesively bonded structures is currently a challenge for aircraft manufacturers. The ability to certify bonds in primary structure can reduce dependence on fasteners and this will enable more efficient manufacturing. For example, drilling holes and installing fasteners in bonded joints can be a potentially significant bottleneck in airframe manufacturing. In addition, fasteners increase the airframe weight and can add stress concentration areas. Reducing fastener count can accelerate manufacturing and improve aircraft performance. NASA is currently investigating nondestructive evaluation (NDE) techniques to assess bond integrity. For example, bond thickness influences bond strength and therefore NDE techniques are being investigated to determine bond thickness. For bonded metal structures, there is a large difference in the thermal diffusivity between the 7075 aluminum alloy metal adherends and aircraft grade adhesive. Multi-layered thermal models show a large variation in the thermal response for bondline adhesive thicknesses that vary from 100 to 300 microns for adherend thicknesses of 0.163 cm. Experimental through-transmission thermal measurements reveal promise to quantitatively characterize the bondline thickness. Results were validated with X-ray computed tomography and optical microscopy measurements, and influence of porosity on the thermal model and measurements are investigated.

bondline thickness↗

In-Space Inspection Needs: Opportunities for advanced NDE tools such as x-ray CT for additively manufactured parts, in-situ resource utilization, geological applications, and more

It is now 50 years since the first human presence on the surface of the Moon and as we strive to return with women and men in the next few years, we embrace new technical challenges, goals, and innovative solutions to address 21st century objectives. These new ambitions carry fresh challenges and risks, with the field of NDE playing an increasingly more relevant role towards meeting these essential goals. In recent years, more advanced NDE tools have triggered a rapid expansion of applications for the space industry. In particular, x-ray Computed Tomography (CT) has proven to be a trusted and powerful asset for spaceflight hardware inspection, as well as applied geotechnical analysis for natural materials (e.g., rocks, soils) for NASA and across industry. However, such methods have yet to be extended to “deep space” applications such as those that are now part of the US National Space Policy Directive (SPD-1) and the accelerated push to return humans to the Moon (i.e., Artemis). For this reason, advancing these powerful Earth-based laboratory methods via new technologies, integrated computational solutions, and creative engineering approaches is directly aligned with national space policies, as well as with multiple NASA Strategic Plan priorities. The use of x-ray CT at scales as fine as a few microns or smaller can identify spacecraft part failure modes relevant to quality assurance for flight hardware and AM parts such as those recently developed for ISS. This technology could also identify valuable metallic phases within geological materials (i.e., rocks or drill cores), enabling resource-relevant triage of samples for In-Situ Resource Utilization (ISRU) and high science value sample return to Earth laboratories. There is also significant application for 3D imaging tools for medical use such as inspecting protective gear as well as bone density degradation studies which are critical in establishing a sustained presence in space. Timing for development of these tools for space use is advantageous as we prepare for new opportunities in the next few years and recognize recent commercial technology advancements which make it feasible. Moreover, as NASA strives to take full advantage of developments in AM technologies, including In-Space Manufacturing (ISM), it is widely recognized that NDE tools such as CT will play an essential role in acceptance of these parts for widespread use. New in-space 3D inspection tools with complimentary technology such as AI-based automated feature recognition (accelerated by machine learning), rapid compositional analysis, and advanced sample manipulation, would be a game-changing step toward a new class of crew-based laboratory sensors once human outposts on the Moon are established.

In-Space Non-Destructive Evaluation↗

Flash Thermal Diffusivity Measurements and Inspection of Additively Manufactured Ti-6Al-4V Specimens with Varying Process Parameters

Flash thermal diffusivity measurements were obtained on additively manufactured Ti-6Al-4V disk shaped specimens with various process parameters. For additively manufactured metal parts, processing parameters such as laser power and scanning speed are critical to ensure the desired microstructure. For this study, the laser powder bed fusion process parameters were changed at various angular sections on a 21 mm diameter and 3.0 mm thick disk. The measurement of thermal diffusivity was performed by fitting a 1-dimensional thermal model to the data pixel by pixel to produce an inspection image. The image revealed the detection of defects such as lack of fusion porosity and areas of aggregated porosity. The thermal diffusivity imagery was compared to immersion scan ultrasonic and X-ray computed tomography (CT) measurements for validation. Based on these results, additional samples were investigated using a single side thermal inspection technique to detect lack of fusion porosity and near surface voids.

thermal nondestructive evaluation↗