Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “additional protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

California GAMA Special Study: Excess Nitrogen and Methane in Noble Gas Samples

The most prominent constituent causing concern for drinking water resources in California is nitrate. Denitrification in the unsaturated zone and in groundwater naturally reduces nitrate concentrations, controls the fate of groundwater nitrate and determines the time scale over which changes in management practice will result in improvements in water quality. Quantifying denitrification is also important in estimating nutrient loading to groundwater through time. Measurements of dissolved nitrogen gas can detect and quantify saturated zone denitrification; and LLNL with GAMA funding has developed benchtop instrumentation to measure dissolved nitrogen in groundwater. This technique, membrane-inlet mass spectrometry (MIMS) requires the collection of an additional sample and is not routinely included in current GAMA water quality monitoring surveys. Incorporating dissolved nitrogen analysis into current water quality monitoring protocols without requiring an additional sample or separate analysis is the most cost-effective way to expand the database of dissolved nitrogen concentrations and document the prevalence of saturated-zone denitrification in California groundwater. The GAMA Priority Basin, Shallow Aquifer Assessment, and Special Study water quality monitoring programs routinely use dissolved noble gas and tritium analyses to constrain groundwater travel times and recharge. Noble gases are collected as a 10-mL water sample in a crimped copper tube and are analyzed by noble gas mass spectrometry (NGMS). Nitrogen, methane and carbon dioxide, can now also be measured in copper tubes and analyzed by the same LLNL NGMS system, which has been upgraded to allow such analyses. In the case of the GAMA Shallow Aquifer Assessment project, this will automatically provide dissolved nitrogen analyses at little or no incremental cost. A significant advantage of this technique is that archival copper tube noble gas samples can be analyzed using the technique. The dissolved nitrogen analyses – combined with nitrate analyses and the NGMS age information – will provide unique insight into nitrate sources, inputs, transport, and reaction rates.

54 ENVIRONMENTAL SCIENCES↗

Multiqubit entanglement generation with squeezed modes

We present a hybrid continuous variable–discrete variable entanglement generation protocol using linear optics and homodyne measurements, capable of producing multiple high-fidelity Bell pairs per protocol iteration, with an approximate 0.5 success probability. The effectiveness of the protocol is determined by the squeezing strength. To increase the number of Bell pairs, approximately 3 dB of extra squeezing is needed for each additional Bell pair. The protocol also generates single Bell pairs with an approximate 0.75 probability for squeezing strengths ⪅ 15 dB , achievable with current technology.

Macridin, Alexandru [Fermilab] (ORCID:000000022228↗

Loss-tolerant quantum secure positioning with weak laser sources

Quantum position verification (QPV) is the art of verifying the geographical location of an untrusted party. It has recently been shown that the widely studied Bennett & Brassard 1984 (BB84) QPV protocol is insecure after the 3 dB loss point assuming local operations and classical communication (LOCC) adversaries. Here in this paper, we propose a time-reversed entanglement swapping QPV protocol (based on measurement-device-independent quantum cryptography) that is highly robust against quantum channel loss. First, assuming ideal qubit sources, we show that the protocol is secure against LOCC adversaries for any quantum channel loss, thereby overcoming the 3 dB loss limit. Then, we analyze the security of the protocol in a more practical setting involving weak laser sources and linear optics. Lastly, in this setting, we find that the security only degrades by an additive constant and the protocol is able to verify positions up to 47 dB channel loss.

47 OTHER INSTRUMENTATION↗

Delay Tolerant Networking - Bundle Protocol Simulation

In this paper, we report on the addition of MACHETE models needed to support DTN, namely: the Bundle Protocol (BP) model. To illustrate the useof MACHETE with the additional DTN model, we provide an example simulation to benchmark its performance. We demonstrate the use of the DTN protocol and discuss statistics gathered concerning the total time needed to simulate numerous bundle transmissions.

licklider protocol↗

Nutritional Status Assessment (SMO 016E)

Until 2006, it was not been possible to assess nutritional status of crewmembers on the ISS during flight because blood and urine could not be collected during ISS missions. Postflight observations of alterations in status of several nutrients are troubling, and we require the ability to monitor the status of these nutrients during flight to determine if there is a specific impetus or timeframe for these changes. In addition to the monitoring of crew nutritional status during flight, in-flight sample collection would allow better assessment of countermeasure effectiveness. Collecting samples during flight is one of the objectives of SMO 016E, and it is also designed to expand the current medical requirement for nutritional assessment (MR016L) to include additional normative markers for assessing crew health and countermeasure effectiveness. Additional markers of bone metabolism will be measured to better monitor bone health and the effectiveness of countermeasures to prevent bone resorption. New markers of oxidative damage will be measured to better assess the type of oxidative insults that occur during space flight. The array of nutritional assessment variables will be expanded to include ones that will allow us to better understand changes in folate, vitamin K, and vitamin B6 status, as well as risk factors for cardiovascular and oxidative damage during and after flight. Stress hormones and hormones that affect bone and muscle metabolism will also be measured. Measuring these additional variables will allow us to better monitor the health of crewmembers and make more accurate recommendations for their rehabilitation. Several nutritional assessment variables are altered at landing, but it is not known how long these changes persist. We extended the original protocol to include an additional postflight blood and urine sample collection 30 days after landing. Data are being collected before, during, and after flight. These data will provide a complete survey of how nutritional status and related systems are affected by space flight. Analyzing the data will help us to define nutritional requirements for long-duration missions. This expanded set of measurements will also aid in the identification of nutritional countermeasures to counteract, for example, the deleterious effects of microgravity on bone and muscle and the effects of space radiation.

Smith, S. M.↗

Nutritional Status Assessment (SMO 016E)

It has not been possible to assess nutritional status of crew members on the ISS during flight because blood and urine could not be collected during ISS missions. Postflight observations of alterations in nutritional status for several nutrients are troubling, and we require the ability to monitor the status of these nutrients during flight to determine if there is a specific impetus or timeframe for these changes. In addition to the monitoring of crew nutritional status during flight, in-flight sample collection would allow better assessment of countermeasure effectiveness. SMO 016E is also designed to expand the current medical requirement for nutritional assessment (MR016L) to include additional normative markers for assessing crew health and countermeasure effectiveness. Additional markers of bone metabolism will be measured to better monitor bone health and the effectiveness of countermeasures to prevent bone resorption. New markers of oxidative damage will be measured to better assess the type of oxidative insults that occur during space flight. The array of nutritional assessment parameters will be expanded to include parameters that will allow us to better understand changes in folate and vitamin B6 status, and related cardiovascular risk factors during and after flight. Additionally, stress hormones and hormones that affect bone and muscle metabolism will also be measured. This additional assessment will allow us to better monitor the health of crew members and make more accurate recommendations for their rehabilitation. Several nutritional assessment parameters are altered at landing, but it is not known how long these changes persist. We extended the current protocol to include an additional postflight blood and urine sample collection 30 days after landing. Data are being collected before, during, and after flight. These data will provide a complete survey of how nutritional status and related systems are affected by space flight. Analyzing the data will help us to define nutritional requirements for long-duration missions. This expanded set of measurements will also aid in the identification of nutritional countermeasures to counteract, for example, the deleterious effects of microgravity on bone and muscle and the effects of space radiation.

Smith, S. M.↗

Exponential Backoff and Its Security Implications for Safety-Critical OT Protocols over TCP/IP Networks

The convergence of Operational Technology (OT) and Information Technology (IT) networks has become increasingly prevalent with the growth of Industrial Internet of Things (IIoT) applications. This shift, while enabling enhanced automation, remote monitoring, and data sharing, also introduces new challenges related to communication latency and cybersecurity. Oftentimes, legacy OT protocols were adapted to the TCP/IP stack without an extensive review of the ramifications to their robustness, performance, or safety objectives. To further accommodate the IT/OT convergence, protocol gateways were introduced to facilitate the migration from serial protocols to TCP/IP protocol stacks within modern IT/OT infrastructure. However, they often introduce additional vulnerabilities by exposing traditionally isolated protocols to external threats. This study investigates the security and reliability implications of migrating serial protocols to TCP/IP stacks and the impact of protocol gateways, utilizing two widely used OT protocols: Modbus TCP and DNP3. Our protocol analysis finds a significant safety-critical vulnerability resulting from this migration, and our subsequent tests clearly demonstrate its presence and impact. A multi-tiered testbed, consisting of both physical and emulated components, is used to evaluate protocol performance and the effects of device-specific implementation flaws. Through this analysis of specifications and behaviors during communication interruptions, we identify critical differences in fault handling and the impact on time-sensitive data delivery. The findings highlight how reliance on lower-level IT protocols can undermine OT system resilience, and they inform the development of mitigation strategies to enhance the robustness of industrial communication networks.

DNP3↗

SU-G-TeP2-01: Can EPID Based Measurement Replace Traditional Daily Output QA On Megavoltage Linac?

Purpose: To investigate the long term stability and viability of using EPID-based daily output QA via in-house and vendor driven protocol, to replace conventional QA tools and improve QA efficiency. Methods: Two Varian TrueBeam machines (TB1&TB2) equipped with electronic portal imaging devices (EPID) were employed in this study. Both machines were calibrated per TG-51 and used clinically since Oct 2014. Daily output measurement for 6/15 MV beams were obtained using SunNuclear DailyQA3 device as part of morning QA. In addition, in-house protocol was implemented for EPID output measurement (10×10 cm fields, 100 MU, 100cm SID, output defined over an ROI of 2×2 cm around central axis). Moreover, the Varian Machine Performance Check (MPC) was used on both machines to measure machine output. The EPID and DailyQA3 based measurements of the relative machine output were compared and cross-correlated with monthly machine output as measured by an A12 Exradin 0.65cc Ion Chamber (IC) serving as ground truth. The results were correlated using Pearson test. Results: The correlations among DailyQA3, in-house EPID and Varian MPC output measurements, with the IC for 6/15 MV were similar for TB1 (0.83–0.95) and TB2 (0.55–0.67). The machine output for the 6/15MV beams on both machines showed a similar trend, namely an increase over time as indicated by all measurements, requiring a machine recalibration after 6 months. This drift is due to a known issue with pressurized monitor chamber which tends to leak over time. MPC failed occasionally but passed when repeated. Conclusion: The results indicate that the use of EPID for daily output measurements has the potential to become a viable and efficient tool for daily routine LINAC QA, thus eliminating weather (T,P) and human setup variability and increasing efficiency of the QA process.

60 APPLIED LIFE SCIENCES↗

NetSim Steer: A Runtime Steering Framework for Network Simulators

This paper presents NetSim-Steer, a runtime steering framework for network simulators. With this framework, users can specify execution constraints for the network protocols and network models. In addition to this, users can implement steering rules to be executed when a constraint is violated. These rules allows users to alter the parameters of the protocols/models during the simulation so that they stay within the boundaries of the constraints.

Network simulation↗

An open-access simulated earthquake ground-motion database for an M7 Hayward Fault earthquake in the San Francisco Bay Region

Comprehensive understanding of earthquake ground motions, particularly in the near-fault region of large-magnitude events, is limited by gaps in strong-motion data. This challenge is prominent in areas with high seismic hazard but infrequent large earthquakes where data is sparse and difficult to interpret. These data limitations lead to uncertainties in the development of site-specific ground motions, which are crucial for engineering risk assessments. To address these challenges, physics-based regional-scale ground-motion simulations have been developed. With the emergence of exaflop-scale computing ecosystems, it is now possible to simulate regional earthquake processes at unprecedented fidelity and generate the large number of fault rupture realizations necessary to characterize both intra- and inter-event ground-motion variability. This article introduces a new database of simulated earthquake ground motions, created for applications in earthquake engineering, earthquake planning, and emergency response. The inaugural version of the database features simulated ground motions for a magnitude 7 Hayward Fault earthquake in the San Francisco Bay Region (SFBR), using the EarthQuake SIMulation (EQSIM) simulation framework and the Graves–Pitarka kinematic rupture model. The aim is to provide high-fidelity, spatially dense, three-component motions generated on the Department of Energy’s (DOE) newest generation of graphics processing unit (GPU)-accelerated supercomputers. These motions are being made openly available to the engineering, scientific, and disaster planning communities. In addition, this work develops protocols for the efficient dissemination of these large data sets and emphasizes community engagement to build confidence in their application. This article discusses the methodology behind the data, underlying software verification and validation, scalable data management, and a user interface for data access. The goal is to facilitate widespread use and elicit expert feedback to maximize the utility and exploitation of simulated motions. While the initial focus is on the San Francisco Region, simulations for additional regions will be added as the DOE program progresses.

Simulated ground-motion database↗

Nanoscale Consequences of Irradiation Investigated by RAD-AFM (Final Report)

To assess the feasibility of measuring material property changes induced by ion irradiation one pristine and three legacy HT-9 samples were sectioned and polished. The polish protocol was first optimized using a pristine unirradiated HT-9 sample before polishing the ion irradiated samples as the spot size was small and repeated polishing could remove the ion irradiated region entirely. AFM tapping mode was used to assess the surface quality after each polish. AFM based hardness mapping was optimized for new diamond tips specifically for use with the HT-9 samples to compensate for differences in grain size, precipitates, and heterogeneity of hardness relative to past samples. In addition, a hardness calibration protocol was developed using NIST copper, nickel, and steel reference materials. Co-located SEM-EDS and AFM analysis was used to verify the ion irradiated edge using the silver/tungsten coating as a fiducial mark. Once benchmarked, the hardness across the ion irradiated cross section, a comparison of bulk hardness according to neutron irradiation, and the hardness of the ion irradiated surface edge was measured.

36 MATERIALS SCIENCE↗

Kilovoltage cone-beam CT: Comparative dose and image quality evaluations in partial and full-angle scan protocols

Purpose: To assess imaging dose of partial and full-angle kilovoltage CBCT scan protocols and to evaluate image quality for each protocol. Methods: The authors obtained the CT dose index (CTDI) of the kilovoltage CBCT protocols in an on-board imager by ion chamber (IC) measurements and Monte Carlo (MC) simulations. A total of six new CBCT scan protocols were evaluated: Standard-dose head (100 kVp, 151 mA s, partial-angle), low-dose head (100 kVp, 75 mA s, partial-angle), high-quality head (100 kVp, 754 mA s, partial-angle), pelvis (125 kVp, 706 mA s, full-angle), pelvis spotlight (125 kVp, 752 mA s, partial-angle), and low-dose thorax (110 kVp, 271 mA s, full-angle). Using the point dose method, various CTDI values were calculated by (1) the conventional weighted CTDI (CTDI{sub w}) calculation and (2) Bakalyar's method (CTDI{sub wb}). The MC simulations were performed to obtain the CTDI{sub w} and CTDI{sub wb}, as well as from (3) central slice averaging (CTDI{sub 2D}) and (4) volume averaging (CTDI{sub 3D}) techniques. The CTDI values of the new protocols were compared to those of the old protocols (full-angle CBCT protocols). Image quality of the new protocols was evaluated following the CBCT image quality assurance (QA) protocol [S. Yoo et al., ''A quality assurance program for the on-board imager registered ,'' Med. Phys. 33(11), 4431-4447 (2006)] testing Hounsfield unit (HU) linearity, spatial linearity/resolution, contrast resolution, and HU uniformity. Results: The CTDI{sub w} were found as 6.0, 3.2, 29.0, 25.4, 23.8, and 7.7 mGy for the new protocols, respectively. The CTDI{sub w} and CTDI{sub wb} differed within +3% between IC measurements and MC simulations. Method (2) results were within {+-}12% of method (1). In MC simulations, the CTDI{sub w} and CTDI{sub wb} were comparable to the CTDI{sub 2D} and CTDI{sub 3D} with the differences ranging from -4.3% to 20.6%. The CTDI{sub 3D} were smallest among all the CTDI values. CTDI{sub w} of the new protocols were found as {approx}14 times lower for standard head scan and 1.8 times lower for standard body scan than the old protocols, respectively. In the image quality QA tests, all the protocols except low-dose head and low-dose thorax protocols were within the tolerance in the HU verification test. The HU value for the two protocols was always higher than the nominal value. All the protocols passed the spatial linearity/resolution and HU uniformity tests. In the contrast resolution test, only high-quality head and pelvis scan protocols were within the tolerance. In addition, crescent effect was found in the partial-angle scan protocols. Conclusions: The authors found that CTDI{sub w} of the new CBCT protocols has been significantly reduced compared to the old protocols with acceptable image quality. The CTDI{sub w} values in the point dose method were close to the volume averaging method within 9%-21% for all the CBCT scan protocols. The Bakalyar's method produced more accurate dose estimation within 14%. The HU inaccuracy from low-dose head and low-dose thorax protocols can render incorrect dose results in the treatment planning system. When high soft-tissue contrast data are desired, high-quality head or pelvis scan protocol is recommended depending on the imaging area. The point dose method can be applicable to estimate CBCT dose with reasonable accuracy in the clinical environment.

60 APPLIED LIFE SCIENCES↗

Impact of Cyber Threat Awareness on Driver Response to an Unexpected Vehicle Cyberattack

Here, the integration of advanced cyber-physical systems in heavy vehicles introduces new vulnerabilities by expanding the possibility of cyberattacks. The objective of this study is to evaluate (1) how threat awareness influences driver response to an unexpected cyberattack, (2) how the provision of a basic cyberattack response protocol influences driver performance, and (3) how professionally trained versus standard drivers compare in their responses to a cyberattack. An on-road driving study (N = 50) was conducted using a medium heavy-duty vehicle. Participants were divided into three groups: Control, which remained unaware of any potential cyberattack; Aware, which was informed about the potential cyberattack; and Aware + Protocol, which received the same warning as the Aware group with the addition of a basic cyberattack response protocol. An instrument cluster cyberattack was executed at the same location for all participants. The findings highlight the essential role of awareness and response protocol in enhancing driver response to an unexpected vehicle cyberattack. The Aware + Protocol group had the highest stop rate (100%) and the shortest stopping distances (224 m for standard drivers and 254 m for professionals), compared to the Control group (828 and 520 m, respectively). Aware + Protocol also had the fastest reaction time, averaging 7.53 s, versus 16.12 s (Aware) and 30.29 s (Control). These results emphasize that awareness alone is insufficient. Providing drivers with clear, actionable protocols significantly improves their ability to react quickly and safely to cyberattacks, enhancing overall road safety.

Cybersecurity↗

Quantitative Assessment of Workload and Stressors in Clinical Radiation Oncology

Purpose: Workload level and sources of stressors have been implicated as sources of error in multiple settings. We assessed workload levels and sources of stressors among radiation oncology professionals. Furthermore, we explored the potential association between workload and the frequency of reported radiotherapy incidents by the World Health Organization (WHO). Methods and Materials: Data collection was aimed at various tasks performed by 21 study participants from different radiation oncology professional subgroups (simulation therapists, radiation therapists, physicists, dosimetrists, and physicians). Workload was assessed using National Aeronautics and Space Administration Task-Load Index (NASA TLX). Sources of stressors were quantified using observational methods and segregated using a standard taxonomy. Comparisons between professional subgroups and tasks were made using analysis of variance ANOVA, multivariate ANOVA, and Duncan test. An association between workload levels (NASA TLX) and the frequency of radiotherapy incidents (WHO incidents) was explored (Pearson correlation test). Results: A total of 173 workload assessments were obtained. Overall, simulation therapists had relatively low workloads (NASA TLX range, 30-36), and physicists had relatively high workloads (NASA TLX range, 51-63). NASA TLX scores for physicians, radiation therapists, and dosimetrists ranged from 40-52. There was marked intertask/professional subgroup variation (P<.0001). Mental demand (P<.001), physical demand (P=.001), and effort (P=.006) significantly differed among professional subgroups. Typically, there were 3-5 stressors per cycle of analyzed tasks with the following distribution: interruptions (41.4%), time factors (17%), technical factors (13.6%), teamwork issues (11.6%), patient factors (9.0%), and environmental factors (7.4%). A positive association between workload and frequency of reported radiotherapy incidents by the WHO was found (r = 0.87, P value=.045). Conclusions: Workload level and sources of stressors vary among professional subgroups. Understanding the factors that influence these findings can guide adjustments to the workflow procedures, physical layout, and/or communication protocols to enhance safety. Additional evaluations are needed in order to better understand if these findings are systemic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ToF-SIMS in material research: A view from nanoscale hydrogen detection

Hydrogen in materials has attracted tremendous interest as its incorporation leads to significant alterations in nanoscale structure, composition, and chemistry, impacting functional properties. It has also been integral to nuclear fusion reactors and is considered a future clean energy source. However, nanoscale characterization and manipulation of hydrogen in materials are challenging as only a selected few analytical techniques can readily detect hydrogen, among which time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a unique and powerful one due to its excellent detection limit along with decent depth and lateral resolutions. Here, in this review, we discuss, using selected examples, how to detect and quantify hydrogen in materials by ToF-SIMS and its impact on revealing the hydrogenation/protonation-induced novel functional states in different classes of materials. In addition, we present our protocols on sample preparation and experimental conditions optimization, allowing us to achieve the best possible results. Finally, we highlight future research directions that can lead to the discovery of novel functional states and ultimately provide a deeper understanding of scientific questions in materials science.

36 MATERIALS SCIENCE↗

An application of different dioids in public key cryptography

Dioids provide a natural framework for analyzing a broad class of discrete event dynamical systems such as the design and analysis of bus and railway timetables, scheduling of high-throughput industrial processes, solution of combinatorial optimization problems, the analysis and improvement of flow systems in communication networks. They have appeared in several branches of mathematics such as functional analysis, optimization, stochastic systems and dynamic programming, tropical geometry, fuzzy logic. In this paper we show how to involve dioids in public key cryptography. The main goal is to create key – exchange protocols based on dioids. Additionally the digital signature scheme is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-A-17A-09: Exploiting Electromagnetic Technologies for Real-Time Seed Drop Position Validation in Permanent Implant Brachytherapy

Purpose: To report on preliminary results validating the performance of a specially designed LDR brachytherapy needle prototype possessing both electromagnetic (EM) tracking and seed drop detection abilities. Methods: An EM hollow needle prototype has been designed and constructed in collaboration with research partner Philips Healthcare. The needle possesses conventional 3D tracking capabilities, along with a novel seed drop detection mechanism exploiting local changes of electromagnetic properties generated by the passage of seeds in the needle's embedded sensor coils. These two capabilities are exploited by proprietary engineering and signal processing techniques to generate seed drop position estimates in real-time treatment delivery. The electromagnetic tracking system (EMTS) used for the experiment is the NDI Aurora Planar Field Generator. The experiment consisted of dropping a total of 35 seeds in a prismatic agarose phantom, and comparing the 3D seed drop positions of the EMTS to those obtained by an image analysis of subsequent micro-CT scans. Drop position error computations and statistical analysis were performed after a 3D registration of the two seed distributions. Results: Of the 35 seeds dropped in the phantom, 32 were properly detected by the needle prototype. Absolute drop position errors among the detected seeds ranged from 0.5 to 4.8 mm with mean and standard deviation values of 1.6 and 0.9 mm, respectively. Error measurements also include undesirable and uncontrollable effects such as seed motion upon deposition. The true accuracy performance of the needle prototype is therefore underestimated. Conclusion: This preliminary study demonstrates the potential benefits of EM technologies in detecting the passage of seeds in a hollow needle as a means of generating drop position estimates in real-time treatment delivery. Such tools could therefore represent a potentially interesting addition to existing brachytherapy protocols for rapid dosimetry validation. Equipments and fundings for this project were provided by Philips Medical.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gold nanocrystal labels provide a sequence–to–3D structure map in SAXS reconstructions

Small-angle x-ray scattering (SAXS) is a powerful technique to probe the structure of biological macromolecules and their complexes under virtually arbitrary solution conditions, without the need for crystallization. While it is possible to reconstruct molecular shapes from SAXS data ab initio, the resulting electron density maps have a resolution of ~1 nm and are often insufficient to reliably assign secondary structure elements or domains. We show that SAXS data of gold-labeled samples significantly enhance the information content of SAXS measurements, allowing the unambiguous assignment of macromolecular sequence motifs to specific locations within a SAXS structure. We first demonstrate our approach for site-specifically internally and end-labeled DNA and an RNA motif. In addition, we present a protocol for highly uniform and site-specific labeling of proteins with small (~1.4 nm diameter) gold particles and apply our method to the signaling protein calmodulin. In all cases, the position of the small gold probes can be reliably identified in low-resolution electron density maps. Enhancing low-resolution measurements by site-selective gold labeling provides an attractive approach to aid modeling of a large range of macromolecular systems.

Science & Technology - Other Topics↗