Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Topics on Test Methods for Space Systems and Operations Safety: Applicability of Experimental Data

This viewgraph presentation reviews topics on test methods for space systems and operations safety through experimentation and analysis. The contents include: 1) Perception of reality through experimentation and analysis; 2) Measurements, methods, and correlations with real life; and 3) Correlating laboratory aerospace materials flammability data with data in spacecraft environments.

Hirsch, David B.↗

Nondestructive spot test method for magnesium and magnesium alloys

A method for spot test identification of magnesium and various magnesium alloys commonly used in aerospace applications is described. The spot test identification involves color codes obtained when several drops of 3 M hydrochloric acid are placed on the surface to be tested. After approximately thirty seconds, two drops of this reacted acid is transferred to each of two depressions in a spot plate for additions of other chemicals with subsequent color changes indicating magnesium or its alloy.

Wilson, M. L.↗

Development of test methods for textile composites

NASA's Advanced Composite Technology (ACT) Program was initiated in 1990 with the purpose of developing less costly composite aircraft structures. A number of innovative materials and processes were evaluated as a part of this effort. Chief among them are composite materials reinforced with textile preforms. These new forms of composite materials bring with them potential testing problems. Methods currently in practice were developed over the years for composite materials made from prepreg tape or simple 2-D woven fabrics. A wide variety of 2-D and 3-D braided, woven, stitched, and knit preforms were suggested for application in the ACT program. The applicability of existing test methods to the wide range of emerging materials bears investigation. The overriding concern is that the values measured are accurate representations of the true material response. The ultimate objective of this work is to establish a set of test methods to evaluate the textile composites developed for the ACT Program.

Masters, John E.↗

Irradiation with molecular hydrogen as an accelerated total dose hardness assurance test method for bipolar linear circuits

High dose rate irradiation with hydrogen stress is proposed as an accelerated total dose test method for bipolar linear circuits. The method is validated across process and circuit technologies with five parts that are commonly used in space: a comparator (LM193 from National Semi-conductor), a voltage regulator (HSYE-117 RH from Intersil), a voltage reference (LT1019 from Linear Technology), a JFET input op amp (OP42 from Analog Devices) and a temperature transducer (AD590 from Analog Devices). The testing technique could rapidly establish an upper bound to the low dose rate response of parts in space and help with the part selection process in the design phase of a mission. The technology dependence and the viability of this technique are qualitatively explored using a physical model describing the dose rate response and the effect of hydrogen in bipolar technologies. The model uses four core processes: 1) space charge effects, 2) free electron/hole pair recombination, hole-hydrogen defect reactions in the oxides and 4) proton depassivation of dangling bonds at the Si/SiO2 interface. Radiation hardness assurance implications are discussed.

Pease, Ron↗

A comparison of three shear test methods for composite materials

A graphite-epoxy composite material system is used to evaluate the performance of three popular shear tests - the 10-deg off-axis, the +/-45-deg tension, and the Iosipescu specimen tested in the modified Wyoming fixture. A comparison of the shear stress-strain response for each test method is made using a conventional strain gage instrument and moire interferometry. The uniformity and purity of the strain fields in the test sections of the specimens are discussed, and the shear responses obtained from each test are presented and compared. It is shown that the shear stress-strain responses obtained by instrumenting only one face of the 90-deg Iosipescu specimen could give erroneous results. The +/-45-deg tensile and 0-deg Iosipescu specimens were not affected by front-to-back face shear strain variations. Correction factors could be applied to bring all responses together, within the limits of the material uniformity, which was itself documented in the moire fringe patterns.

Ho, H.↗

Development of Simplified Model Test Methods for Creep-Fatigue Evaluation

The Simplified Model Test (SMT) approach is an alternative creep-fatigue evaluation method that no longer requires the use of the damage interaction diagram, or D-diagram. The reason is that the combined effects of creep and fatigue are accounted for in the test data by means of a SMT specimen that is designed to replicate or bound the stress and strain redistribution that occurs in actual components when loaded in the creep regime. However, creep-fatigue experiments on SMT key feature articles are specialized and difficult to perform by the general research community. In this paper, two innovative SMT based creep-fatigue experimental methods are developed and implemented. These newly-developed SMT test methods have resolved all the critical challenges in the SMT key feature article testing and enable the potential of further development of the SMT based creep-fatigue evaluation method into a standard testing method. Scoping test results on Alloy 617 and SS 316H using the newly developed SMT methods are summarized and discussed. The concepts of the SMT methodology for creep-fatigue evaluation are explained.

Wang, Yanli↗

A new experimental testing method for investigation of creep-dominant creep-fatigue interaction in Alloy 617 at 950 °C

An experimental testing procedure is proposed for generating creep-dominant creep-fatigue interaction in Alloy 617 at 950 °C. Most experimental studies on Alloy 617 at elevated temperatures employ a purely strain-controlled loading waveform with a tensile hold period. Strain-controlled loading can only generate interaction in the fatigue-dominant regime of the damage interaction diagram, due to the saturation effect of increasing hold time on cycle life. This saturation is caused by the rapid stress relaxation of Alloy 617 at high temperatures. Design codes for components undergoing creep-fatigue interaction at high temperatures require creep-fatigue testing data in the creep-dominant regime. Here this study investigates multiple creep-fatigue loading waveforms with the objective of producing creep-dominant interaction. The custom loading waveforms are implemented on a servo-hydraulic load frame with a furnace. A hybrid-control scheme with strain-controlled ramps and load-controlled hold periods is proposed due to its flexibility in generating varying proportions of creep and fatigue damage. Experimental data is presented and different loading schemes are compared. Special emphasis is on the creep and fatigue damage contributions by the newly proposed testing method. Several conclusions are discussed and an extension of this current work is suggested to improve the damage interaction diagram for design purposes.

36 MATERIALS SCIENCE↗

A new test method for the assessment of the arc tracking properties of wire insulation in air, oxygen enriched atmospheres and vacuum

Development of a new test method suitable for the assessment of the resistance of aerospace cables to arc tracking for different specific environmental and network conditions of spacecraft is given in view-graph format. The equipment can be easily adapted for tests at different realistic electrical network conditions incorporating circuit protection and the test system works equally well whatever the test atmosphere. Test results confirm that pure Kapton insulated wire has bad arcing characteristics and ETFE insulated wire is considerably better in air. For certain wires, arc tracking effects are increased at higher oxygen concentrations and significantly increased under vacuum. All tests on different cable insulation materials and in different environments, including enriched oxygen atmospheres, resulted in a more or less rapid extinguishing of all high temperature effects at the beginning of the post-test phase. In no case was a self-maintained fire initiated by the arc.

Koenig, Dieter↗

ComPort: Rigorous Testing Methods to Safeguard Software Porting (Final UW Report)

This report summarizes the University of Washington’s contributions to the ComPort project, Rigorous Testing Methods to Safeguard Software Porting, funded under the U.S. Department of Energy, Office of Science, Office of Advanced Scientific Computing Research (ASCR), award number DE-SC0022081. UW’s work addressed numerics-driven correctness challenges arising in heterogeneous and rapidly evolving computing environments. Our efforts focused on developing interactive analysis tools, correctness-preserving rewriting systems, semantic-aware code-transformation infrastructure, and multi-language support for reproducible numerical experiments.

97 MATHEMATICS AND COMPUTING↗

Development of a standard capture efficiency test method for residential kitchen ventilation

Cooking activities are a major source of indoor air pollutants. To control pollutants generated from cooking activities, a range hood is commonly used in residential kitchens. Several building codes require that a range hood be installed in new homes to control pollutants from cooking, and the required airflow rates for range hoods are specified by indoor air quality standards. However, airflow alone does not show how much of the cooking pollutants are exhausted by the range hood. A better metric to evaluate range hood indoor air quality performance is capture efficiency -- the fraction of contaminants emitted during cooking that are exhausted directly to the outside via the range hood. The current article summarizes the development of a range hood capture efficiency test method for use in laboratory testing and equipment rating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stress corrosion evaluation of powder metallurgy aluminum alloy 7091 with the breaking load test method

The stress corrosion behavior of the P/M aluminum alloy 7091 is evaluated in two overaged heat treatment conditions, T7E69 and T7E70, using an accelerated test technique known as the breaking load test method. The breaking load data obtained in this study indicate that P/M 7091 alloy is highly resistant to stress corrosion in both longitudinal and transverse orientations at stress levels up to 90 percent of the material yield strength. The reduction in mean breaking stress as a result of corrosive attack is smallest for the more overaged T7E70 condition. Details of the test procedure are included.

Domack, Marcia S.↗

Flammability Test Method for Materials Intended for Use as Fire Barriers in Crewed Habitats

In some crewed-spacecraft applications, onboard materials are intentionally selected to function as hazard control barriers to prevent powered hardware and/or ignited flammable items from igniting nearby flammable materials by acting as non-breaching, non-flammable containment (e.g., cargo transfer bags, zero gravity stowage racks, and jettison stowage bags on the International Space Station). Historically, flammability self-extinguishment testing of broad acreage or outermost layer materials alone was believed to be sufficient to verify overall flammability compliance. Though required, testing on design features such as threaded seams and zippers was not performed due to the incorrect assumption that flammability performance would not be impacted. However, recent coupon level testing of layups and configurations consisting of multiple materials have revealed that these features may be more susceptible to ignition and fire propagation than the bulk material. Additionally, configurational coupon ignition and propagation testing does not explicitly determine a material’s ability to provide protection to vulnerable flammable hardware. The need to evaluate this gap in assessing material or layup effectiveness as fire barriers between ignition sources and flammable materials led to the development of a new configuration-based fire barrier test. Test setup, relevant configurations, and test validation are discussed. The new barrier test method establishes a configuration for the test apparatus, identifies a conservative ignitor configuration, and defines pass/fail criteria. Test setup, relevant configurations, and test validation are discussed.

Susana Harper↗

Development of a Standard Test Method for Reducing the Uncertainties in Measuring the Capture Efficiency of Range Hoods

Cooking activities are a major source of indoor air pollutants. To control pollutants generated from cooking activities, a range hood is commonly used in residential kitchens. Several building codes require that a range hood be installed in new homes to control pollutants from cooking, and the required airflow rates for range hoods are specified by indoor air quality (IAQ) standards. However, air flow alone does not tell us how much of the cooking pollutants are exhausted by the range hood. A better metric to evaluate range hood IAQ performance is capture efficiency (CE)—the fraction of contaminants emitted during cooking that are exhausted directly to the outside via the range hood. This paper summarizes the development of a range hood CE test method for use in laboratory testing and equipment rating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Solid Polymers, Ceramic Gap Filler, and Closed-Cell Polymer Foam Using Low-Load Test Methods

Various solid polymers, polymer-based composites, and closed-cell polymer foam are being characterized to determine their mechanical properties, using low-load test methods. The residual mechanical properties of these materials after environmental exposure or extreme usage conditions determines their value in aerospace structural applications. In this experimental study, four separate polymers were evaluated to measure their individual mechanical responses after thermal aging and moisture exposure by dynamic mechanical analysis. A ceramic gap filler, used in the gaps between the tiles on the Space Shuttle, was also tested, using dynamic mechanical analysis to determine material property limits during flight. Closed-cell polymer foam, used for the Space Shuttle External Tank insulation, was tested under low load levels to evaluate how the foam's mechanical properties are affected by various loading and unloading scenarios.

Herring, Helen M.↗

The stress-corrosion behavior of Al-Li-Cu alloys: A comparison of test methods

Two powder metallurgy processed (Al-Li-Cu) alloys with and without Mg addition were studied in aqueous 3.5% NaCl solution during the alternate immersion testing of tuning fork specimens, slow crack growth tests using fracture mechanics specimens, and the slow strain rate testing of straining electrode specimens. Scanning electron microscopy and optical metallography were used to demonstrate the character of the interaction between the Al-Li-Cu alloys and the selected environment. Both alloys are susceptible to SC in an aqueous 3.5% NaCl solution under the right electrochemical and microstructural conditions. Each test method yields important information on the character of the SC behavior. Under all conditions investigated, second phase particles strung out in rows along the extrusion direction in the alloys were rapidly attacked, and played principal role in the SC process. With time, larger pits developed from these rows of smaller pits and under certain electrochemical conditions surface cracks initiated from the larger pits and contributed directly to the fracture process. Evidence to support slow crack growth was observed in both the slow strain rate tests and the sustained immersion tests of precracked fracture mechanics specimens. The possible role of H2 in the stress corrosion cracking process is suggested.

Rizzo, P. P.↗

An experimental and analytical investigation of the rail shear-test method as applied to composite materials

This report presents the results from an experimental and analytical investigation of the stress distributions occurring in a rail shear test. The effects of non-uniform stresses induced by differential thermal expansion, rail flexibility and specimen aspect ratio on measured shear modulus and ultimate strength of composite laminates are shown. A two-dimensional linearly elastic finite element model was used to analytically determine how various geometric parameters influenced the magnitude and distribution of inplane normal and shear stresses in a tensile rail shear specimen. Rail shear tests were conducted at room temperature and 589 K (600 F) on selected graphite-polyimide composite laminates using two titanium rail configurations. The analysis and test methods are discussed, and the results of the effects of the various parameters on shear modulus and ultimate strength are presented.

Garcia, R.↗

Mechanical behavior of AISI 304SS determined by miniature test methods after neutron irradiation to 28 dpa

The mechanical properties of AISI 304 stainless steel irradiated for over a decade in the Experimental Breeder Reactor (EBR-II) were measured using miniature mechanical testing methods. The shear punch method was used to evaluate the shear strengths of the neutron-irradiated steel and a correlation factor was empirically determined to predict its tensile strength. The strength of the stainless steel slightly decreased with increasing irradiation temperature, and significantly increased with increasing dose until it saturated above approximately 5 dpa. Ferromagnetic measurements were used to observe and deduce the effects of the stress-induced austenite to martensite transformation as a result of shear punch testing.

304 stainless steel↗

Establishing Standardized Test Methods for Evaluating Space Suit Gloves

The Artemis space suit glove environmental protection garment (EPG) will be the first line of protection used to shield the crewmember’s hands from the environments encountered during extravehicular activity (EVA). As the Artemis missions will include more extreme environments than those experienced on the International Space Station, development, verification, and validation of gloves poses three key challenges. First, there are no standardized tests defined to evaluate the durability of space suit gloves for the extreme lunar environments, particularly the permanently shadowed regions. Second, there is insufficient data on state-of-the-art glove performance in a lunar environment from which to compare new designs. Third, current ISS glove Thermal Micrometeoroid Garment (TMG) fabrics are unlikely to be sufficient to meet Lunar requirements. It is therefore necessary to define tests to evaluate if gloves can meet new, challenging requirements. This paper focuses on the development of a test procedure to characterize lunar EVA glove fabrics using ASTM standardized test methods and the design and validation of a new standardized test procedure for comparing abrasion resistance between fabrics in lunar-like conditions. The results of testing on twelve candidate EVA glove fabrics are presented.

Robert J. Jones↗