An integrated-circuit direct-coupled amplifier for spacecraft use
Integrated circuit, direct coupled, differential amplifier for spacecraft signal conditioning
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Integrated circuit, direct coupled, differential amplifier for spacecraft signal conditioning
The advantages and disadvantages of different models of capacitive transducers and of various signal conditioning circuits are discussed with particular emphasis on the field of applications. A practical example of a design procedure is discussed.
Two rotating data systems for engine component testing which demonstrate the techniques of on-the-shaft microelectronic signal conditioning and rotary transformer power- and data-transfer are described. (1) A digital data system provides 69 channels of 1100 C maximum thermocouple data with less than 0.5 percent error from a turbine test rig rotating at speeds up to 9000 rpm. (2) An analog data system amplifies and transfers 72 channels of dynamic strain data with less than 5 percent error from a compressor rig at speeds above 14,000 rpm.
A modular instrument system is being developed to handle the many data channels encountered in turbojet engine testing. Each module contains a group of transducers and all the signal conditioning multiplexing, and digitizing electronics necessary for direct interface with a digital computer. The digital interface within each module is the same for all modules; in addition, each module provides a controlled environment for its contents. A minicomputer in the control room gathers the data, performs on-line calculation and display, and interfaces with a shared recording and computing system. The advantages of this system are: (1) reduced manpower for system installation, setup, and checkout; (2) standardized equipment interfaces; (3) increased reliability through automatic system testing and minimization of manual adjustments; and (4) reduced cost through minimization of wiring and simplification of control room display.
Low cost method is described for signal conditioning of pot-type transducers utilizing printed circuitry. Conditioner fits into standard rack, accommodates 56 channels, and can be operated by one attendant.
HAL accomplishes three significant objectives: (1) increased readability, through the use of a natural two-dimensional mathematical format; (2) increased reliability, by providing for selective recognition of common data and subroutines, and by incorporating specific data-protect features; (3) real-time control facility, by including a comprehensive set of real-time control commands and signal conditions. Although HAL is designed primarily for programming on-board computers, it is general enough to meet nearly all the needs in the production, verification and support of aerospace, and other real-time applications.
An eight-channel biomedical telemetry system provides four channels of blood flow measurements in addition to blood-pressure and EKG data. Emphasis is placed on the amplifiers and signal conditioning circuitry required for interfacing of the electromagnetic flow transducers with the transmission and modulation subsystems. The large number of data channels permits measurement of flow distribution as well as total cardiac output. The batteries and electronics for four channels (blood flow) weigh about 500 g and have a volume of 250 cu cm.
The basic information is presented, which is required for start-up and operation of two long-wavelength focal-plane and cooler assemblies, including the amplifiers and temperature control systems. The focal plane systems, referred to as the long wavelength spectrometer (LWS) were developed for direct replacement of Arrays 3 and 4 into the multispectral scanner presently being operated by the NASA Manned Spacecraft Center Facility, and Laboratory Support Branch. The equipment is comprised of two major sub-assemblies: Array 3 with three indium antimonide detector channels and Array 4 with seven mercury doped Germanium detector channels. Each array is mounted on a cryogenic cooler and includes the vacuum housings, mounting hardware (x, y, z translation and rotation stages) and detector signal conditioning, temperature control and monitoring electronics. The two arrays were designed to operate independently and do not share common equipment (viz power supplies, housings, mounts, etc.).
Two rotating data systems for engine component testing, which demonstrate the techniques of on-the-shaft microelectronic signal conditioning and rotary transformer power- and data-transfer, are described. These systems are a digital data system which provides 69 channels of 1100 C maximum thermocouple data with less than 0.5% error from a turbine test rig rotating at speeds up to 9000 rpm and an analog data system which amplifies and transfers 72 channels of dynamic strain data with less than 5% error from a compressor rig at speeds above 14,000 rpm.
A new modular instrument system is being developed to handle the many channels of data commonly encountered in turbojet engine testing. Each module contains a group of transducers and all the signal conditioning, multiplexing, and digitizing electronics necessary for direct interface with a digital computer. The digital interface within each module is the same for all modules. Each module provides a controlled environment for its contents. A minicomputer in the control room gathers the data, performs some on-line calculation and display, and interfaces with a shared recording and computing system. The advantages of this system are (1) reduced manpower for system installation, setup, and checkout; (2) standardized equipment interfaces; (3) increased reliability through automatic system testing and through minimization of manual adjustments; and (4) reduced cost through minimization of wiring and simplification of control room display.
Capacitive strain gage and signal conditioning system measures stress-induced strain and cancels thermal expansion strain at temperatures to 1,500 F (815 C). Gage does not significantly restrain or reinforce specimen.
System serves as central station which can monitor voltage variations through transmission lines connnected to equipment scattered in different locations. Voltage-controlled oscillator is optional. It is used in some systems to condition signal to make it compatible with certain types of oscillographs.
A computer-controlled data acquisition system has been developed for the 40x80-foot wind tunnel at Ames Research Center. The system, consisting of several small onboard units installed in the model and a data-managing, data-displaying ground station, is capable of sampling up to 256 channels of raw data at a total sample rate of 128,000 samples/sec. Complete signal conditioning is contained within the on-board units. The sampling sequence and channel gain selection is completely random and under total control of the ground station. Outputs include a bar-graph display, digital-to-analog converters, and digital interface to the tunnel's central computer, an SEL 840MP. The system can be run stand-alone or under the control of the SEL 840MP.
An integrated PCM data system is being developed at Ames Research Center to gather test data on advanced STOL propulsive lift, VTOL, rotary wing, and V/STOL control systems concepts as they pass through wind-tunnel, test-stand, flight-simulator and flight-test phases. Identical airborne signal conditioning and PCM encoding is used on test aircraft and wind tunnel models. An 80,000 word/second PCM installation will be the first all PCM-instrumented rotary wing development project. The system uses both dedicated and time-shared computers for fast data analysis with maximum use of resources. This system development shows one way to bring separate data user groups together over a common data base, while sharing computing resources for minimum cost.-
A power processing system (PPS) for a communication satellite, high power (200W RF) multi-stage depressed collector, 12 GHz, traveling wave tube, is described. The PPS converts spacecraft bus power at a nominal voltage of 76 Vdc to the levels necessary for operating a ten-collector coupled cavity TWT requiring approximately 500 watts of input power. Regulated voltages of up to -11.3K Vdc are provided along with command, protection and telemetry signal conditioning circuits. Power processor interface requirements are set forth and a block diagram illustrating the basic approach utilized is presented. Overall performance, design characteristics and unique features are discussed. Thermal and mechanical interface requirements impacting on PPS design are described as well as the thermal control technique utilized for the overall PPS/TWT assembly.
Remote multiplexer/demultiplexer digital instrumentation system, which is suitable to both airborne and ground-based data acquisition/process control applications, can be employed in a variety of research and flight test applications where great flexibility to accommodate changes in number of parameters, data sampling rates, and signal conditioning is required.
An animal exposure test system has been designed and fabricated for the purpose of collecting physiological and environmental (temperature) data from animal subjects exposed to combustion gases in large scale fire tests. The AETS consists of an open wire mesh, two-compartment cage, one containing an exercise wheel for small rodents, and the other containing one rat instrumented externally for electrocardiogram and respiration. The ECG and respiration sensors are located in a belt placed around the torso of the subject, electrode wires forming an umbilical to a connector in the top of the compartment. A cable extends from the connector to the power supply and signal conditioning electronics. These are connected to a dual-beam oscilloscope for real time monitoring and a magnetic tape recorder having three or more channels. Endpoints observed are bradycardia, cardiac arrhythmias, changes in respiratory pattern, respiratory arrest and cardiac arrest. The ECG record also appears to be a good method of monitoring animal activity as indicated by an increase in EMG noise superimposed on the record during increased activity of the torso musculature. Examples of the recordings are presented and discussed as to their significance regarding toxicity of fire gases.
The possibility of standard low temperature detector(s) for use in upcoming cryogenically cooled satellite and Space Shuttle Payloads was investigated. These payloads operate from .3 Kelvin to 300 Kelvin. Standard detectors were selected and matching signal conditioning equipment were specified. This equipment will operate in a spacecraft environment and be compatible with the selected detector, typical spacecraft voltages, typical spacecraft telemetry systems, and the radiation encountered by a typical earth orbiting spacecraft. Work statements to better define and advance detector performance are presented.