Engineering PapersSearch

SEARCH · Engineering Papers

Results for “SPENT FUEL STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

334 records · Page 8

Correlating Impacts of Injected Fuels on Carbon Emissions in Blast Furnace with Computational Fluid Dynamics Modeling

A major challenge for steelmaking is the reduction of CO 2 emissions. In this regard, the blast furnace (BF) is critical due to the high associated CO 2 levels. This investigation assesses the impact of tuyere‐injected fuels on BF CO 2 emissions. Specifically, computational fluid dynamics results obtained previously at Purdue University Northwest are analyzed to obtain CO 2 emissions when natural gas (NG), syngas, hydrogen, or hydrogen/NG are injected. CO 2 emissions are compared with those produced when 95 kg of NG/thm is injected. Among these scenarios, the largest CO 2 reduction occurs when 102 kg of syngas/thm (COG feedstock #1) is injected at 973 K, reducing CO 2 by 190.6 kg thm −1 . The largest CO 2 reduction obtained with NG occurs when 130 kg thm −1 is injected at 600 K, reducing emissions by 65 kg thm −1 . H 2 injection also reduces CO 2 , but requires careful adjusting to reach stable operation. For instance, injecting 35 kg of H 2 /thm reduces CO 2 by 52 kg thm −1 . Increasing gaseous injection rates can significantly reduce CO 2 emissions, with fuel preheating providing an addendum, but high injection rates can lead to unstable operation. Furthermore, results show a correlation between CO 2 emissions and average temperature of shaft region for multiple fuels and injection conditions.

Metallurgy & Metallurgical Engineering

Cost-effective valorization of 2,3-butanediol to high-value chemicals and jet fuel

Here, this work outlines an optimized process for converting 2,3-butanediol (BDO) into sustainable aviation fuel (SAF) and C4 chemicals. BDO is reactively separated from fermentation broth by forming dioxolanes, which are converted to isobutyraldehyde, methyl ethyl ketone (MEK), and 1,3-butadiene. These intermediates are reduced and dehydrated over Cu/ZSM-5 to form alkenes, which can be oligomerized and hydrotreated to jet-range alkanes. Previous BDO-dioxolane-alkene processes are limited by the requirement for a continuous aldehyde source for dioxolane formation. Brønsted acidic zeolites catalyze dioxolane deacetalization to form isobutyraldehyde and MEK in a >2:1 molar ratio, providing an internal, recyclable aldehyde source. Dioxolane formation optimization was performed to achieve >95% dioxolane yields over Amberlyst-15 and minimize isobutyraldehyde recycle. The overall BDO-dioxolane-fuel process yields an alkane mixture that enables at least a 50% v/v blend with Jet-A. Techno-economic analyses and life cycle assessments for this BDO-dioxolane-fuel process yield scenarios with <$2.50 per gallon gas equivalent and >58% reduction in CO2 emissions.

2,3-butanediol

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer

Dynamic sparse x-ray nanotomography reveals ionomer hydration mechanism in polymer electrolyte fuel-cell catalyst

Tomographic imaging of time-evolving samples is a challenging yet important task for various research fields. At the nanoscale, current approaches face limitations of measurement speed or resolution due to lengthy acquisitions. We developed a dynamic nanotomography technique based on sparse dynamic imaging and 4D tomography modeling. We demonstrated the technique, using ptychographic x-ray computed tomography as its imaging modality, on resolving the in situ hydration process of polymer electrolyte fuel cell (PEFC) catalyst. The technique provides a 40-time increase in temporal resolution compared to conventional approaches, yielding 28 nm half-period spatial and 12 min temporal resolution. The results allow a quantitative characterization of the water intake process inside PEFC catalysts with nanoscale resolution, which is crucial for understanding their electrochemical mechanisms and optimizing their performance. Our technique enables high-speed operando nanotomography studies and paves the way for wider application of dynamic tomography at the nanoscale.

Science & Technology - Other Topics

Cation-Diffusive Carbon Interlayers Stabilize Na Metal and Double the Current in Na-S Redox-Flow Batteries for Grid-Scale Energy Storage

The sodium-sulfur nonaqueous redox-flow batteries (Na-S NARFBs) using earth-abundant elements are highly attractive due to the low material cost and improved energy density for grid-scale energy storage. However, the low current performance, poor Na0/Na+ redox kinetics, and Na dendrite growth pose severe challenges. We introduce cation-diffusive layers (CDLs): thin and Na+ affinitive interlayers at the Na anode that direct Na+ transport and stabilize Na deposition. Benchmarking three archetypal materials—carbon paper (CP), glass microfiber paper (GF), and foam—across Na-Na and Na-Cu, and Na-S cells identifies CP as the optimum. CP reduces symmetric cell overpotential by more than 70%, achieves 98% Na plating-stripping efficiency, and doubles the Na-S cell current density from 0.5 to 1.0 mA cm−2 without sacrificing capacity or efficiency. Ex situ electrochemical and SEM/XPS analysis, combined with molecular dynamics (MD) studies, reveal that electron-rich carbon fibers disperse supporting salt aggregates, enrich near-surface Na+ density, and create ion transport pathways for fast Na0/Na+ exchange while mitigating membrane degradation. Because of the ion-centric mechanism, CDLs can be generalized to other metal-anode designs. Further, this work establishes CDL design rules—cationic affinity and appropriate micro/nanostructure—as a simple, scalable route to high-current, durable metal-anode flow batteries.

Wu, Wenda [ORNL] (ORCID:000900033307687X)

Effect of Oxidizing Impurities on the Corrosion Behavior of Structural Alloys Exposed to MgCl 2 Molten Salt Vapor

The corrosion behavior of structural alloys SS304 and IN617 when exposed to vapors of MgCl 2 molten salt at 764 °C for 100 h in an argon atmosphere was investigated as a function of the level of oxidizing impurities (e.g., NaOH) present in the salt. Increasing the concentration of oxidizing impurities in the salt caused an increase in corrosion in both structural alloys, as measured by Cr depletion layers. A poorly adhered oxide scale layer containing Mg, Al, and Cr was observed on the surface of the metals, and local attack was observed as well. The Ni-based IN617 showed lower Cr depletion and less scale formation than the Fe-based SS304. These results demonstrate that oxidizing impurities in the molten salt will impact the vapor phase corrosion for structural members exposed to the molten salt headspace. This finding is highly relevant for understanding the effects of the vapor phase in molten salt applications, including molten salt thermal energy storage, molten salt nuclear reactors, and molten salt electrochemistry.

25 ENERGY STORAGE

Advanced-Research-on-Integrated-Energy-Systems-Based Analysis to Support Resilient System Upgrades: Energy to Communities Energyshed In-Depth Partnership with Molokai, Hawaii

The Molokai, Hawaii, Energy to Communities (E2C) Energyshed project represents a collaborative effort between the National Laboratory of the Rockies, Shake Energy Collaborative, the Molokai Clean Energy Hui, Sustainable Molokai, and Ho'ahu Energy Cooperative Molokai to advance Molokai's Community Energy Resilience Action Plan (CERAP). Supported by Hawaiian Electric Company and the Hawaii State Energy Office, the initiative aims to develop a community-defined portfolio of renewable energy solutions that enhance energy resilience while aligning with the Hawaiian Electric Integrated Grid Plan (IGP) and Molokai's energy goals. Phase 1 focused on technical analyses and community engagement to co-design feasible energy scenarios. Challenges such as grid upgrades, storage sizing, and inverter ride-through standards were addressed to align technical and operational requirements with community preferences. The project equips Molokai with actionable data and insights to implement energy initiatives while ensuring resilient and culturally informed solutions. Future efforts aim to finalize project designs, secure interconnection agreements, and deploy energy projects that reflect community priorities and technical feasibility.

24 POWER TRANSMISSION AND DISTRIBUTION

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]