Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Multiplicity Counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Experimental Evaluation of the Fast-Neutron Passive Collar (FNPC) Performance and Comparison with Scintillation Based Collars

This report describes a new method for the verification of fresh low enrichment uranium (LEU) fuel assemblies that can reduce International Atomic Energy Agency (IAEA) inspection time in the field and be completely independent of operator declared burnable poison content. The passive measurement makes unattended mode operation practical, and thus provides the potential for reducing inspector time in the field for future applications. The new simplified passive neutron measurement uses the 238 U spontaneous fission in LEU fresh fuel rods to self-interrogate the 235 U mass in the neighboring rods. The measured response increases linearly with the increase in the linear density (LD) of 235 U. The relatively high efficiency of the passive neutron detector (24%) provides good statistical precision (~ 2%) for the singles, doubles, and triples counting rates in the thermal-neutron mode. The three observables makes possible multiplicity analysis so that both the 235 U LD and the effective burnable poison content can be determined independent of the operator declarations. This closes the potential diversion path of miss-declaration the burnable poison content. This report presents the detector design, the as-built system, the detector parameter measurements, the calibration, and the assay uncertainty estimates. The calibration measurements were performed using the Los Alamos Laboratory mockup PWR fuel assembly. The measurements were made in both the fastneutron mode (with Cd/Gd metal liners) and the thermal-neutron mode (no Cd/Gd liners).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Estimation of Confidence Intervals for Multiplication and Efficiency

Helium-3 tubes are used to detect thermal neutrons by charge collection using the {sup 3}He(n,p) reaction. By analyzing the time sequence of neutrons detected by these tubes, one can determine important features about the constitution of a measured object: Some materials such as Cf-252 emit several neutrons simultaneously, while others such as uranium and plutonium isotopes multiply the number of neutrons to form bursts. This translates into unmistakable signatures. To determine the type of materials measured, one compares the measured count distribution with the one generated by a theoretical fission chain model. When the neutron background is negligible, the theoretical count distributions can be completely characterized by a pair of parameters, the multiplication M and the detection efficiency {var_epsilon}. While the optimal pair of M and {var_epsilon} can be determined by existing codes such as BigFit, the uncertainty on these parameters has not yet been fully studied. The purpose of this work is to precisely compute the uncertainties on the parameters M and {var_epsilon}, given the uncertainties in the count distribution. By considering different lengths of time tagged data, we will determine how the uncertainties on M and {var_epsilon} vary with the different count distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Am–Li neutron spectra data for active well type neutron multiplicity measurements of uranium

Safeguarding nuclear material is an important and challenging task for the international community. One particular safeguards technique commonly used for uranium assay is active neutron correlation counting. This technique involves irradiating unused uranium with ( α,n) neutrons from an Am-Li source and recording the resultant neutron pulse signal which includes induced fission neutrons. Although this non-destructive technique is widely employed in safeguards applications, the neutron energy spectra from an Am-Li sources is not well known. Several measurements over the past few decades have been made to characterize this spectrum; however, little work has been done comparing the measured spectra of various Am-Li sources to each other. This paper examines fourteen different Am-Li spectra, focusing on how these spectra affect simulated neutron multiplicity results using the code Monte Carlo N-Particle eXtended (MCNPX). Two measurement and simulation campaigns were completed using Active Well Coincidence Counter (AWCC) detectors and uranium standards of varying enrichment. The results of this work indicate that for standard AWCC measurements, the fourteen Am-Li spectra produce similar doubles and triples count rates. Finally, the singles count rates varied by as much as 20% between the different spectra, although they are usually not used in quantitative analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determining plutonium in spent fuel with nondestructive assay techniques

There are a variety of motivations for quantifying plutonium in used (spent) fuel assemblies by means of nondestructive assay including the following: shipper/receiver difference, input accountability at reprocessing facilities and burnup credit at repositories or fuel storage facilities. Twelve NDA techniques were identified that provide information about the composition of an assembly. Unfortunately, none of these techniques is capable of determining the Pu mass in an assembly on its own. However, it is expected that the Pu mass can be quantified by combining a few of the techniques. Determining which techniques to combine and estimating the expected performance of such a system is the purpose of the research effort recently begun. The research presented here is a complimentarily experimental effort. This paper will focus on experimental results of one of the twelve non-destructive assay techniques - passive neutron albedo reactivity. The passive neutron albedo reactivity techniques work by changing the multiplication the pin experiences between two separate measurements. Since a single spent fuel pin has very little multiplication, this is a challenging measurement situation for the technique. Singles and Doubles neutron count rate were measured at Oak Ridge National Laboratory for three different burnup pins to test the capability of the passive neutron albedo reactivity technique.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ANNIE Phase I: Neutron Background Measurements

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton Gd-doped water Cherenkov detector installed in the Booster Neutrino Beam (BNB) at Fermilab. The primary physics goal of ANNIE is to study the multiplicity of final state neutrons from neutrino-nucleus interactions in water. Identifying and counting final state neutrons provides a new experimental handle to study systematic uncertainties related to the neutrino energy reconstruction in oscillation experiments. To achieve that goal ANNIE will make the first use of the novel Large Area Picosecond PhotoDetectors (LAPPDs). In Phase I, ANNIE characterised the beam-correlated neutron backgrounds in the detector and confirmed that they are sufficiently low for the Phase II physics measurements, anticipated to begin in 2019. In these proceesings the methodology and the results of Phase I will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Progress in development of neutron energy spectrometer for deuterium plasma operation in KSTAR

Two types of DD neutron energy spectrometer (NES) are under development for deuterium plasma operation in KSTAR to understand behavior of beam ions in the plasma. One is based on the state-of-the-art nuclear emulsion technique. The other is based on a coincidence detection of a recoiled proton and a scattered neutron caused by an elastic scattering of an incident DD neutron, which is called an associated particle coincidence counting-NES. The prototype NES systems were installed at J-port in KSTAR in 2012. During the 2012 and 2013 experimental campaigns, multiple shots-integrated neutron spectra were preliminarily obtained by the nuclear emulsion-based NES system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Approach-to-Critical Results in Current and Pulse Mode for Systems with High Starter Neutron Rates

Reactors and critical assemblies use a variety of detection systems to monitor the neutron population. The count rate is proportional to the neutron flux present at the location of the detector. When such systems are placed external to an assembly, it is often assumed that the relative leakage multiplication will be proportional to the detector count rate (assuming that the source term, system geometry, and detector placement have not changed). Such systems are often used in an approach-to-critical during reactor startup to ensure that the critical configuration is well predicted. Various types of detectors have been used during an approach-to-critical. These include 3 He, BF 3 , ion chambers, fission chambers, and fission foils. Any of these types of systems (or others) should work well when adequate counting statistics are available. These detector systems can be operated in either pulse or current mode. The National Criticality Experiments Research Center (NCERC) has two detection systems that are commonly used in critical assembly operations. The start-up (referred to as "SU" in this work) system is made up of 3 He proportional counters in pulse mode and the linear counter system (referred to as "LC" in this work) consists of compensated ion-chambers in current mode. Typically the SU system is used for approach-to-critical operations and the LC system is only used at/above delayed critical ( k eff = 1). This work investigates the use of the LC system for an approach-to-critical. It has been long hypothesized that such an approach would be feasible for systems with high starter neutron rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active neutron and gamma-ray imaging of highly enriched uranium for treaty verification

The detection and characterization of highly enriched uranium (HEU) presents a large challenge in the non-proliferation field. HEU has a low neutron emission rate and most gamma rays are low energy and easily shielded. To address this challenge, an instrument known as the dual-particle imager (DPI) was used with a portable deuterium-tritium (DT) neutron generator to detect neutrons and gamma rays from induced fission in HEU. We evaluated system response using a 13.7-kg HEU sphere in several configurations with no moderation, high-density polyethylene (HDPE) moderation, and tungsten moderation. A hollow tungsten sphere was interrogated to evaluate the response to a possible hoax item. First, localization capabilities were demonstrated by reconstructing neutron and gamma-ray images. Once localized, additional properties such as fast neutron energy spectra and time-dependent neutron count rates were attributed to the items. For the interrogated configurations containing HEU, the reconstructed neutron spectra resembled Watt spectra, which gave confidence that the interrogated items were undergoing induced fission. The time-dependent neutron count rate was also compared for each configuration and shown to be dependent on the neutron multiplication of the item. This result showed that the DPI is a viable tool for localizing and confirming fissile mass and multiplication.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiple-Coincidence Active Neutron Interrogation of Fissionable Materials

In an extension of the Associated Particle Imaging technique that is used for the detection and imaging of hidden explosives, the present measurements use a beam of tagged 14.1 MeV neutrons in coincidence with two or more gammas to probe for the presence of fissionable materials. We have measured neutron-gamma-gamma coincidences with targets of depleted uranium, tungsten, lead, iron, and carbon and will present results that show the multiple-coincidence counting rate for the depleted uranium is substantially higher than any of the non-fissionable materials. In addition, the presence of coincidences involving delayed particle spectra provides a signature for fissionable materials that is distinct from that for non-fissionable ones. Information from the tagged neutron involved in the coincidence event is used to compute the position of the fissionable material in all three dimensions. The result is an imaging probe for fissionable materials that is compact and portable, and produces relatively low levels of background radiation. Simultaneous measurements on packages of interest for both explosives and fissionable materials are now feasible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Neutron Measurement Capabilities; Expanding the Limits of Correlated Neutron Counting

A number of technical and practical limitations exist within the neutron correlated counting techniques used in safeguards, especially within the algorithms that are used to process and analyze the detected neutron signals. A multi-laboratory effort is underway to develop new and improved analysis and data processing algorithms based on fundamental physics principles to extract additional or more accurate information about nuclear material bearing items.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maximum Likelihood Source Localization Using Elpasolite as a Dual Gamma Neutron Directional Detector

The problem of accurately detecting extremely low levels of nuclear radiation is rapidly increasing in importance in nuclear counter-proliferation, verification, and environmental and waste management. Because the 239Pu gamma signature may be weak, for instance, even when compared to the natural terrestrial background, coincidence counting with the 239Pu neutron signature may improve overall 239Pu detection sensitivity. However, systems with sufficient multiple-particle detectors require demonstration that the increased sensitivity be sufficiently high to overcome added cost and weight. We report the results of measurements and calculations to determine sensitivity that can be gained in detecting low levels of nuclear radiation from use of a relatively new detector technology based on elpasolite crystals. We have performed investigations exploring cerium (Ce3+)-doped elpasolites Cs2LiYCl6:Ce3+0.5% (CLYC) and Cs2LiLa(Br6)90%(Cl6)10%:Ce3+0.5% (CLLBC:Ce). These materials can provide energy resolution (r(E) = 2.35σ(E)/E) as good as 2.9% at 662 keV (FWHM). The crystals show an excellent neutron and gamma radiation response. The goals of the investigation were to set up the neutron/gamma pulse shape discrimination electronics for elpasolite detectors; perform limited static source benchmarking, testing, and evaluation to validate system performance; and explore application of a maximum likelihood algorithm for source location. Data were measured and processed through a maximum likelihood estimation algorithm, providing a direction to the radioactive source for each individual position. The estimated directions were good representations for the actual directions to the radioactive source. This paper summarizes the maximum likelihood results for our elpasolite system.

maximum likelihood, radiation detectors, neutron d↗

Equipment for subcriticality monitoring by pulse method - 240

At the present time methods and means of determining, evaluating, and monitoring the effective neutron multiplication factor or the subcriticality are becoming very important for validating and monitoring nuclear safety in connection with the accumulation of a large number of spent fuel assemblies and the transition to a more tight mode of their storage arrangement in the spent-fuel pools of NPP. Pulse method is an effective subcriticality monitoring tool for subcritical reactors and spent nuclear fuel storages. This method is based on the use neutron generator, fission chambers and instrumentation for data acquisition and processing. The measurement and control equipment was designed. It allows: neutron pulses generation with specified parameters; neutron flux response monitoring by measuring the count rate at predetermined set of sequential time intervals; data transmitting to the personal computer; data processing and subcriticality calculation; self diagnostics and health monitoring; data recording, archiving and storage. The special device is proposed to check the electronic equipment. This device simulates a signal of a neutron detector counting rate after neutron generator pulses appear. The paper presents hardware structure and composition, specification and software of the control unit, which provides neutron generator operation, data acquisition and processing. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Determining plutonium mass in spent fuel using Cf-252 interrogation with prompt neutron detection

{sup 252}Cf Interrogation with Prompt Neutron (CIPN) detection is proposed as one of 14 NDA techniques to determine Pu mass in spent fuel assemblies (FAs). CIPN is a low-cost and portable instrument, and it looks like a modified fork detector combined with an active interrogation source. Fission chamber (FC) is chosen as neutron detector because of its insensitivity to {gamma} radiation. The CIPN assay is comprised of two measurements, a background count and an active count, without and with the {sup 252}Cf source next to the fuel respectively. The net signal above background is primarily due to the multiplication of Cf source neutrons caused by the fissile content. The capability of CIPN to detect diversion and to determine fissile content was quantified using MCNPX simulations. New schemes were proposed (such as burnup and cooling time correction, etc.) and the results show that the fissile content of a target spent fuel assembly can be determined using CIPN signal.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Feynman-Y Statistic in Relation to Shift-Register Neutron Coincidence Counting: Precision and Dead Time

The Feynman-Y statistic is a type of autocorrelation analysis. It is defined as the excess variance-to-mean ratio, Y = VMR - 1, of the number count distribution formed by sampling a pulse train using a series of non-overlapping gates. It is a measure of the degree of correlation present on the pulse train with Y = 0 for Poisson data. In the context of neutron coincidence counting we show that the same information can be obtained from the accidentals histogram acquired using the multiplicity shift-register method, which is currently the common autocorrelation technique applied in nuclear safeguards. In the case of multiplicity shift register analysis however, overlapping gates, either triggered by the incoming pulse stream or by a periodic clock, are used. The overlap introduces additional covariance but does not alter the expectation values. In this paper we discuss, for a particular data set, the relative merit of the Feynman and shift-register methods in terms of both precision and dead time correction. Traditionally the Feynman approach is applied with a relatively long gate width compared to the dieaway time. The main reason for this is so that the gate utilization factor can be taken as unity rather than being treated as a system parameter to be determined at characterization/calibration. But because the random trigger interval gate utilization factor is slow to saturate this procedure requires a gate width many times the effective 1/e dieaway time. In the traditional approach this limits the number of gates that can be fitted into a given assay duration. We empirically show that much shorter gates, similar in width to those used in traditional shift register analysis can be used. Because the way in which the correlated information present on the pulse train is extracted is different for the moments based method of Feynman and the various shift register based approaches, the dead time losses are manifested differently for these two approaches. The resulting estimates for the dead time corrected first and second order reduced factorial moments should be independent of the method however and this allows the respective dead time formalism to be checked. We discuss how to make dead time corrections in both the shift register and the Feynman approaches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of temporally- and spatially-resolved neutron production in a sheared-flow stabilized Z-pinch

A novel approach using multiple scintillator detectors is applied to measure temporally- and spatially-resolved neutron production in the Fusion Z-pinch Experiment (FuZE) device, a Sheared-Flow Stabilized (SFS) Z-pinch. Diagnosing neutron production from FuZE is important for determining if fusion is thermonuclear and whether the FuZE device can be scaled toward reactor conditions. Absolute yields of up to 2 × 10 5 neutrons per discharge are measured with calibrated plastic scintillator detectors operating in pulse-counting mode. Neutron emission durations of up to ~8 μs are inferred by recording the time difference between the first and last pulses for each discharge. Multiple scintillator detectors located at different positions with respect to the fusing plasma are used to demonstrate that the axial extent of the neutron producing region is comparable to the device volume. Scintillator detectors are well-suited as neutron diagnostics for FuZE and other plasma devices with similar yields and emission durations. Increasing the neutron yield, duration, and volume of the neutron emitting region within the plasma column are significant experimental objectives for FuZE.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging of dynamic magnetic fields with spin-polarized neutron beams

Precession of neutron spin in a magnetic field can be used for mapping of a magnetic field distribution, as demonstrated previously for static magnetic fields at neutron beamline facilities. The fringing in the observed neutron images depends on both the magnetic field strength and the neutron energy. In this paper we demonstrate the feasibility of imaging periodic dynamic magnetic fields using a spin-polarized cold neutron beam. Our position-sensitive neutron counting detector, providing with high precision both the arrival time and position for each detected neutron, enables simultaneous imaging of multiple phases of a periodic dynamic process with microsecond timing resolution. The magnetic fields produced by 5- and 15-loop solenoid coils of 1 cm diameter, are imaged in our experiments with ~100 μm resolution for both dc and 3 kHz ac currents. Our measurements agree well with theoretical predictions of fringe patterns formed by neutron spin precession. We also discuss the wavelength dependence and magnetic field quantification options using a pulsed neutron beamline. Furthermore, the ability to remotely map dynamic magnetic fields combined with the unique capability of neutrons to penetrate various materials (e.g., metals), enables studies of fast periodically changing magnetic processes, such as formation of magnetic domains within metals due to the presence of ac magnetic fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ADVANTG Results for a Proposed NDA System for Detecting Pin Diversion from SNF - Paper 120

This summary describes the results of applying the ADVANTG variance reduction parameter generator to accelerate continuous-energy Monte Carlo simulations of the {sup 252}Cf Interrogation with Prompt Neutron (CIPN) detection system proposed by Hu et al. for detecting the diversion of fuel elements from spent nuclear fuel (SNF) assemblies. In previous work, ADVANTG was applied to a suite of nine radiation detection, special nuclear material (SNM) movement detection, and safeguards test cases. That effort demonstrated that ADVANTG was able to provide large increases in tally figures of merit (FOMs) in nearly all of the cases without introducing bias into the Monte Carlo results. The objective of the work described here is to further evaluate ADVANTG, and also to identify gaps in capability with regard to nuclear safeguards applications, by applying the code to a challenging problem that is of a different nature from the ones previously studied. The CIPN nondestructive assay (NDA) system consists of three fission chambers embedded in a C-shaped block of polyethylene and a polyethylene-moderated {sup 252}Cf source that are placed on opposite sides of a subject SNF assembly. The idea of the detection system is to measure the difference between the background neutron count rate, due to spontaneous fission in the fuel material, and the count rate observed once the source is introduced, which is dominated by multiplication within the assembly. Based on the difference between these count rates, the fissile content of the assembly can be inferred, and this information can be used to determine if some fraction of the original fuel pins have been replaced with depleted uranium substitutes. The authors report that the system can detect the replacement of at least eight pins (3% of total mass). The ADVANTG code generates space- and energy-dependent weight-window bounds and biased source distributions based on approximate transport solutions that are efficiently generated by the Denovo 3-D discrete ordinates package. ADVANTG implements the Consistent Adjoint Driven Importance Sampling (CADIS) method for accelerating individual tallies and the Forward-Weighted CADIS (FW-CADIS) method for obtaining relatively uniform uncertainties across tallies over multiple regions and/or energy bins. The variance reduction parameters are generated in a format directly usable by standard versions of MCNP5 and MCNPX. In this work, the ADVANTG variance reduction parameter generator was applied to accelerate continuous energy MCNPX simulations of the {sup 252}Cf Interrogation with Prompt Neutron detection system for detecting the diversion of fuel elements from SNF assemblies. Variance reduction parameters generated with the existing version of ADVANTG actually slowed down tally convergence in all cases. The cause of the poor performance was found to be the lack of an induced fission source treatment in the fixed-source discrete ordinates calculations employed by ADVANTG. Because fission was treated as capture and not as a source, the importance maps generated by ADVANTG significantly underestimated the importance of thermal neutrons in and around the fuel elements. In order to obtain improved results, we developed an experimental implementation of a fission source outer iteration for the adjoint calculations. We used this prototype capability to generate new variance reduction parameters and found that the mean fission rates agreed well with those predicted by the conventional MCNPX simulations, as was expected. With these new parameters, speedup factors of 59 to 80 were obtained for the case with the background source, and factors of 17 to 24 were obtained for the cases with the interrogating source. These results demonstrate that a fission source treatment is needed to improve the effectiveness of ADVANTG in problems where the effects of induced fission are important. This includes many types of NDA problems that are relevant to safeguards applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AWCC Simulations

Neutron well counters provide a means to measure fissile mass by detecting coincident neutrons, which is a unique signature to fission. For coincidence counting, mass is determined using a calibration curve established with items that have the same material characteristics. Multiplicity analysis solves the point model equations for mass using known detector parameters. In both cases, mass measurements may exhibit a bias due to item characteristics and should be corrected for. Experiments can be done to estimate bias and material effects, but they require having both the well counter and the material well defined. In pursuit of estimating measurement bias and uncertainty in a High Efficiency Neutron Counter (HENC), an MCNP simulation was matched to measurements performed with an Active Well Coincidence Counter (AWCC) to de ne a neutron source term. The neutron source term will be used to predict measurement performance of similar material types in a HENC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗