Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Combination of Measurements of the Top Quark Mass from Data Collected by the ATLAS and CMS Experiments at s = 7 and 8 TeV

A combination of fifteen top quark mass measurements performed by the ATLAS and CMS experiments at the LHC is presented. The datasets used correspond to an integrated luminosity of up to 5 and 20 fb − 1 of proton-proton collisions at center-of-mass energies of 7 and 8 TeV, respectively. The combination includes measurements in top quark pair events that exploit both the semileptonic and hadronic decays of the top quark, and a measurement using events enriched in single top quark production via the electroweak t channel. The combination accounts for the correlations between measurements and achieves an improvement in the total uncertainty of 31% relative to the most precise input measurement. The result is m t = 172.52 ± 0.14 ( stat ) ± 0.30 ( syst ) GeV , with a total uncertainty of 0.33 GeV. © 2024 CERN, for the CMS and ATLASs Collaboration 2024 CERN

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Combination of measurements of the top quark mass from data collected by the ATLAS and CMS experiments at $\sqrt{s}=7$ and $8~\mathrm{TeV}$

A combination of fifteen top quark mass measurements performed by the ATLAS and CMS experiments at the LHC is presented. The data sets used correspond to an integrated luminosity of up to 5 and $20~\mathrm{fb}^{-1}$ of proton-proton collisions at center-of-mass energies of 7 and $8~\mathrm{TeV}$, respectively. The combination includes measurements in top-quark pair events that exploit both the semi-leptonic and hadronic decays of the top quark, and a measurement using events enriched in single top quark production via the electroweak $t$-channel. The combination yields $m_{\mathrm{t}} = 172.52 \pm 0.14~(\mathrm{stat}) \pm 0.30~(\mathrm{syst}) ~\mathrm{GeV}$, with a total uncertainty of $0.33~\mathrm{GeV}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Twin Knudsen Cell Configuration for Activity Measurements by Mass Spectrometry

A twin Knudsen cell apparatus for alloy activity measurements by mass spectrometry is described. Two Knudsen cells - one containing an alloy and one containing a pure component - are mounted on a single flange and translated into the sampling region via a motorized x-y table. Mixing of the molecular beams from the cells is minimized by a novel system of shutters. Activity measurements were taken on two well-characterized alloys to verify the operation of the system. Silver activity measurements are reported for Ag-Cu alloys and aluminum activity measurements are reported for Fe-Al alloys. The temperature dependence of activity for a 0.474 mol fraction Al-Fe alloy gives a partial molar heat of aluminum. Measurements taken with the twin cell show good agreement with literature values for these alloys.

Jacobson, N. S.↗

Multiple-Point Mass Flux Measurement System Using Rayleigh Scattering

A multiple-point Rayleigh scattering diagnostic is being developed to provide mass flux measurements in gas flows. Spectroscopic Rayleigh scattering is an established flow diagnostic that has the ability to provide simultaneous density, temperature, and velocity measurements. Rayleigh scattered light from a focused 18 Watt continuous-wave laser beam is directly imaged through a solid Fabry-Perot etalon onto a CCD detector which permits spectral analysis of the light. The spatial resolution of the measurements is governed by the locations of interference fringes, which can be changed by altering the etalon characteristics. A prototype system has been used to acquire data in a Mach 0.56 flow to demonstrate feasibility of using this system to provide mass flux measurements. Estimates of measurement uncertainty and recommendations for system improvements are presented

Mielke, Amy F.↗

Progress on a Rayleigh Scattering Mass Flux Measurement Technique

A Rayleigh scattering diagnostic has been developed to provide mass flux measurements in wind tunnel flows. Spectroscopic molecular Rayleigh scattering is an established flow diagnostic tool that has the ability to provide simultaneous density and velocity measurements in gaseous flows. Rayleigh scattered light from a focused 10 Watt continuous-wave laser beam is collected and fiber-optically transmitted to a solid Fabry-Perot etalon for spectral analysis. The circular interference pattern that contains the spectral information that is needed to determine the flow properties is imaged onto a CCD detector. Baseline measurements of density and velocity in the test section of the 15 cm x 15 cm Supersonic Wind Tunnel at NASA Glenn Research Center are presented as well as velocity measurements within a supersonic combustion ramjet engine isolator model installed in the tunnel test section.

Mielke-Fagan, Amy F.↗

Continuous Measurement Of Mass Density Of Yarn

Prototype instrument provides measurement data from which one computes mass density of strand of yarn. Includes fixtures placing known length of yarn under known tension across fixed and movable support. Transverse vibrations induced in yarn by moving movable support up and down. Source of light illuminates photodetector at midlength of yarn, and photodetector senses repeated shadowing caused by vibration of yarn through light, thereby measuring vibrations. Also used for continuous real-time monitoring of such yarn-manufacturing processes as coating or impregnation.

Hinkley, Jeffrey A.↗

AWCC Simulations

Neutron well counters provide a means to measure fissile mass by detecting coincident neutrons, which is a unique signature to fission. For coincidence counting, mass is determined using a calibration curve established with items that have the same material characteristics. Multiplicity analysis solves the point model equations for mass using known detector parameters. In both cases, mass measurements may exhibit a bias due to item characteristics and should be corrected for. Experiments can be done to estimate bias and material effects, but they require having both the well counter and the material well defined. In pursuit of estimating measurement bias and uncertainty in a High Efficiency Neutron Counter (HENC), an MCNP simulation was matched to measurements performed with an Active Well Coincidence Counter (AWCC) to de ne a neutron source term. The neutron source term will be used to predict measurement performance of similar material types in a HENC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mass spectrometric measurements of the neutral gas composition of the thermosphere and exosphere of Venus

The neutral gas composition and density in the thermosphere of Venus is being measured with a quadrupole mass spectrometer on the Pioneer Venus orbiter. Data are obtained near periapsis once per day approximately 150-250 km above the surface. The principal gases in the thermosphere are CO2, CO, N2, O, N, and He. Atomic oxygen is the major constituent above 155 km on the dayside and also on the nightside up to 180 km when helium becomes the major constituent. The average values of CO2, CO, N2, O, and N remain nearly constant during day and night, but an abrupt change occurs across the terminator from a high dayside value to a low nightside value. The helium density varies in the opposite way, and a distinct bulge was observed at night near the morning terminator. The data have been used as the basis of an empirical model. Large orbit to orbit variations in densities were also observed on the nightside, suggesting perhaps strong turbulent motion in the atmosphere below. Kinetic temperatures inferred from scale heights are approximately 285 K on the dayside and 110 K at night. The average global temperature obtained from the model is 199 K.

Niemann, H. B.↗

An assessment of the meteoritic contribution to the Martian soil

The flux of meteoritic material at Mars was assessed and the perturbations to the indigenous soil produced by the addition of meteoritic material to the Martian soil was determined. Using the measured mass influx at earth and the estimates of the Mars/earth flux ratio, the planet-wide mateoritic mass influx on Mars was found to be between 2700 and 59,000 t/yr. Assuming a uniform distribution into a soil with a mean planetary production rate of 1 m/b.y., it is estimated that this mass influx would produce a meteoritic concentration in the Mars soil ranging from 2 to 29 percent by mass. Experimental measurements which a Mars lander spacecraft could make to determine the fraction of meteoritic material in the soils are suggested.

Flynn, George J.↗

Innovative mechanism for measuring the mass properties of an object

The Kennedy Space Center Robotics Group recently completed development and testing on a novel approach to measure the mass properties of a rigid body. This unique design can measure the payload's weight, mass center location, and moments of inertia about three orthogonal axes. Furthermore, these measurements only require a single torque sensor and a single angular position sensor.

Wolcott, Kedron R.↗

Mapping the frontiers of the nuclear mass surface

Nuclear masses play a central role in nuclear astrophysics, significantly impacting the origin of the elements and observables used to constrain ultradense matter. A variety of techniques are available to meet this need, varying in their emphasis on precision and reach from stability. Here I briefly summarize the status of and near-future for the time-of-flight magnetic-rigidity (TOF-Bρ) mass measurement technique, emphasizing the complementary and interconnectedness with higher-precision mass measurement methods. This includes of recent examples from TOF-Bρ mass measurements that map the evolution of nuclear structure across the nuclear landscape and significantly impact the results and interpretation of astrophysical model calculations. I also forecast expected expansion in the known nuclear mass surface from future measurement at the Facility for Rare Isotope Beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring the mass of the black widow PSR J1555-2908

ABSTRACT Accurate measurements of the masses of neutron stars are necessary to test binary evolution models, and to constrain the neutron star equation of state. In pulsar binaries with no measurable post-Keplerian parameters, this requires an accurate estimate of the binary system’s inclination and the radial velocity of the companion star by other means than pulsar timing. In this paper, we present the results of a new method for measuring this radial velocity using the binary synthesis code Icarus. This method relies on constructing a model spectrum of a tidally distorted, irradiated star as viewed for a given binary configuration. This method is applied to optical spectra of the newly discovered black widow PSR J1555–2908. By modeling the optical spectroscopy alongside optical photometry, we find that the radial velocity of the companion star is 397 ± 4 km s−1 (errors quoted at 95 per cent confidence interval), as well as a binary inclination of >75°. Combined with γ-ray pulsation timing information, this gives a neutron star mass of 1.67$^{+0.15}_{-0.09}$ M⊙ and a companion mass of 0.060$^{+0.005}_{-0.003}$ M⊙, placing PSR J1555–2908 at the observed upper limit of what is considered a black widow system.

Kennedy, M. R.↗

Giotto Ion Mass Spectrometer Measurements at Comet P/Grigg-Skjellerup

The Giotto Ion Mass Spectrometer High Intensity Spectrometer (IMS-HIS) measured fluxes of ions from about 260,000 km before (10:08:37 UT spacecraft time) to about 86,000 km after (17:01:33 UT spacecraft time) closest approach to comet P/Grigg- Skjellerup during the encounter on July 10, 1992. Although the HIS sensor was not designed to measure protons, the unusual flyby geometry at Grigg-Skjellerup allowed the sensor to detect these ions. Considerable temporal structure appears in the data, well- correlated with the data of other instruments onboard, especially those of the magnetometer. In particular, the proton count rate correlates with the direction of the magnetic field.

Rosenbauer, H.↗

Giotto ion mass spectrometer measurements at comet P/Grigg-Skjellerup

The Giotto ion mass spectrometer high-intensity spectrometer (IMS-HIS) measured fluxes of ions from about 260,000 km before (1008:37 UT spacecraft time) to about 86,000 km after (1701:33 UT spacecraft time) closest approach to comet P/Grigg-Skjellerup during the encounter on July 10, 1992. Although the HIS sensor was not designed to measure protons, these ions were measured far from the comet. Close in to the comet, the ions observed were probably also protons, although heavier ions cannot be completely ruled out. Considerable temporal structure appears in the data, well-correlated with the data of other instruments onboard, especially those of the magnetometer. In particular, the ion count rate correlates with the direction of the magnetic field. This strong modulation at the water group ion cyclotron period (approx. 90 s) inside the inbound bow wave indicates a very narrow ion pitch angle distribution. Hence at Grigg-Skjellerup the ions appear to experience very little pitch angle scattering. This may result from strong compression in the rapidly increasing magnetic field.

Goldstein, R.↗

Composite fermion mass: Experimental measurements in ultrahigh quality two-dimensional electron systems

Composite fermions (CFs), exotic quasiparticles formed by pairing an electron and an even number of magnetic flux quanta, emerge at high magnetic fields in an interacting electron system, and can explain phenomena such as the fractional quantum Hall state (FQHS) and other many-body phases. CFs possess an effective mass (m CF ) whose magnitude is inversely related to the most fundamental property of a FQHS, namely its energy gap. Here we present here experimental measurements of m CF in ultrahigh quality two-dimensional electron systems confined to GaAs quantum wells of varying thickness. An advantage of measuring m CF over gap measurements is that mass values are insensitive to disorder and are therefore ideal for comparison with theoretical calculations, especially for high-order FQHS. Our data reveal that m CF increases with increasing well width, reflecting a decrease in the energy gap as the electron layer becomes thicker and the in-plane Coulomb energy softens. Comparing our measured masses with available theoretical results, we find significant quantitative discrepancies, highlighting that more rigorous and accurate calculations are needed to explain the experimental data.

36 MATERIALS SCIENCE↗