Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION EXTRACTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Mechanism of Exact Transition between Cationic and Anionic Redox Activities in Cathode Material Li 2 FeSiO 4

The discovery of anion redox activity is promising for boosting the capacity of lithium ion battery (LIB) cathodes. However, fundamental understanding of the mechanisms that trigger the anionic redox is still lacking. In this study, using hybrid density functional study combined with experimental soft X-ray absorption spectroscopy (sXAS) measurements, we unambiguously proved that Li (2-x) FeSiO 4 performs sequent cationic and anionic redox activity through delithiation. Specifically, Fe 2+ is oxidized to Fe 3+ during the first Li ion extraction per formula unit (f.u.), while the second Li ion extraction triggered the oxygen redox exclusively. Cationic and anionic redox result in electron and hole polaron states, respectively, explaining the poor conductivity of Li (2-x) FeSiO 4 noted by previous experiments. In contrast, other cathode materials in this family exhibit diversity of the redox process. Li 2 MnSiO 4 shows double cationic redox (Mn 2+ -Mn 4+ ) during the whole delithiation, while Li 2 CoSiO 4 shows simultaneous cationic and anionic redox. The present finding not only provides new insights into the oxygen redox activity in polyanionic compounds for rechargeable batteries but also sheds light on the future design of high-capacity rechargeable batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Upgrade of the extraction system of permanent magnet electron cyclotron resonance ion source

A set of new ion extraction electrodes have been designed for the permanent magnetic electron cyclotron resonance ion source at Peking University to improve beam quality and transmission. PBGUNS has been used to optimize the extraction electrodes and simulate the beam behavior at the extraction region. The experiments showed that with the new system, the beam half divergence angle can be less than 40 mrad and the normalized rms emittance is about 0.13{pi} mm mrad when the extracted current is 100 mA at 50 keV in pulse mode. The voltage of the suppression electrode has great effect on beam divergence. The effect of the microwave power and gas flow is also studied.

43 PARTICLE ACCELERATORS↗

Controlling Electron Backstreaming Phenomena Through the Use of a Transverse Magnetic Field

DEEP-SPACE mission propulsion requirements can be satisfied by the use of high specific impulse systems such as ion thrusters. For such missions. however. the ion thruster will be required to provide thrust for long periods of time. To meet the long operation time and high-propellant throughput requirements, thruster lifetime must be increased. In general, potential ion thruster failure mechanisms associated with long-duration thrusting can be grouped into four areas: (1) ion optics failure; (2) discharge cathode failure; (3) neutralizer failure; and (4) electron backstreaming caused by accelerator grid aperture enlargement brought on by accelerator grid erosion. The work presented here focuses on electron backstreaming. which occurs when the potential at the center of an accelerator grid aperture is insufficient to prevent the backflow of electrons into the ion thruster. The likelihood of this occurring depends on ion source operation time. plasma density, and grid voltages, as accelerator grid apertures enlarge as a result of erosion. Electrons that enter the gap between the high-voltage screen and accelerator grids are accelerated to the energies approximately equal to the beam voltage. This energetic electron beam (typically higher than 1 kV) can damage not only the ion source discharge cathode assembly. but also any of the discharge surfaces upstream of the ion acceleration optics that the electrons happen to impact. Indeed. past backstreaming studies have shown that near the backstreaming limit, which corresponds to the absolute value of the accelerator grid voltage below which electrons can backflow into the thruster, there is a rather sharp rise in temperature at structures such as the cathode keeper electrode. In this respect operation at accelerator grid voltages near the backstreaming limit is avoided. Generally speaking, electron backstreaming is prevented by operating the accelerator grid at a sufficiently negative voltage to ensure a sufficiently negative aperture center potential. This approach can provide the necessary margin assuming an expected aperture enlargement. Operation at very negative accelerator grid voltages, however, enhances ion charge-exchange and direct impingement erosion of the accelerator grid. The focus of the work presented here is the mitigation of electron backstreaming by the use of a magnetic field. The presence of a magnetic field oriented perpendicular to the thruster axis can significantly decrease the magnitude of the backflowing electron current by significantly reducing the electron diffusion coefficient. Negative ion sources utilize this principle to reduce the fraction of electrons in the negative ion beam. The focus of these efforts has been on the attenuation of electron current diffusing from the discharge plasma into the negative ion extraction optics by placing the transverse magnetic field upstream of the extraction electrodes. In contrast. in the case of positive ion sources such as ion thrusters, the approach taken in the work presented here is to apply the transverse field downstream of the ion extraction system so as to prevent electrons from flowing back into the source. It was found in the work presented here that the magnetic field also reduces the absolute value of the electron backstreaming limit voltage. In this respect. the applied transverse magnetic field provides two mechanisms for electron backstreaming mitigation: (1) electron current attenuation and (2) backstreaming limit voltage shift. Such a shift to less negative voltages can lead to reduced accelerator grid erosion rates.

Foster, John E.↗

Downstream plasma transport and metal ionization in a high-powered pulsed-plasma magnetron

Downstream plasma transport and ionization processes in a high-powered pulsed-plasma magnetron were studied. The temporal evolution and spatial distribution of electron density (n{sub e}) and temperature (T{sub e}) were characterized with a 3D scanning triple Langmuir probe. Plasma expanded from the racetrack region into the downstream region, where a high n{sub e} peak was formed some time into the pulse-off period. The expansion speed and directionality towards the substrate increased with a stronger magnetic field (B), largely as a consequence of a larger potential drop in the bulk plasma region during a relatively slower sheath formation. The fraction of Cu ions in the deposition flux was measured on the substrate using a gridded energy analyzer. It increased with higher pulse voltage. With increased B field from 200 to 800 Gauss above racetrack, n{sub e} increased but the Cu ion fraction decreased from 42% to 16%. A comprehensive model was built, including the diffusion of as-sputtered Cu flux, the Cu ionization in the entire plasma region using the mapped n{sub e} and T{sub e} data, and ion extraction efficiency based on the measured plasma potential (V{sub p}) distribution. The calculations matched the measurements and indicated the main causes of lower Cu ion fractions in stronger B fields to be the lower T{sub e} and inefficient ion extraction in a larger pre-sheath potential.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Compact electron beam ion sources/traps: Review and prospects (invited)

The Dresden electron beam ion trap (EBIT)/electron beam ion source (EBIS) family are very compact and economically working table-top ion sources. We report on the development of three generations of such ion sources, the so-called Dresden EBIT, Dresden EBIS, and Dresden EBIS-A, respectively. The ion sources are classified by different currents of extractable ions at different charge states and by the x-ray spectra emitted by the ions inside the electron beam. We present examples of x-ray measurements and measured ion currents extracted from the ion sources at certain individual operating conditions. Ion charge states of up to Xe{sup 48+} but also bare nuclei of lighter elements up to nickel have been extracted. The application potential of the ion sources is demonstrated via proof-of-concept applications employing an EBIT in a focused ion beam (FIB) column or using an EBIT for the production of nanostructures by single ion hits. Additionally we give first information about the next generation of the Dresden EBIS series. The so-called Dresden EBIS-SC is a compact and cryogen-free superconducting high-B-field EBIS for high-current operation.

43 PARTICLE ACCELERATORS↗

Product specific thermal degradation kinetics of bisphenol F epoxy in inert and oxidative atmospheres using evolved gas analysis–mass spectrometry

Knowledge of the degradation kinetics for polymer materials is important for understanding thermal stability. In this study, evolved gas analysis–mass spectrometry and pyrolysis gas-chromatography-mass spectrometry were evaluated for the potential to deliver additional insight into thermal degradation kinetics of diglycidal ether of bisphenol F (DGEBF) epoxy thermoset under inert and oxidative atmospheres. Degradation products of selected precursor ions were evaluated for their uniqueness to the specific precursor using extracted ion thermographs. Unique mass peaks, solely attributed to a single reaction pathway of a specific product, were determined from extracted ion thermographs and used to determine both activation energy (E a ) and pre-exponential factors for the specific primary reaction pathways. These primary reaction pathways for DGEBF epoxy degradation were then evaluated in the context of transition state theory (TST) and related transition state enthalpies (ΔH ‡ ) and entropies (ΔS ‡ ) of activation to further elucidate the degradation process. It was determined under pyrolysis conditions, as suggested by the E a , the formation of bisphenol F monomer was the rate-limiting step toward the formation of xanthene and phenol. In contrast, under thermo-oxidative conditions, reactions involving oxygen containing species were identified as the rate-limiting step for all observed products based on the large negative ΔS ‡ calculated from TST. This work demonstrates a powerful combination of technique and theory that can provide new insight into the degradation of polymer materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of Compact Penning Ion Source for Material Studies

Development of ion sources of various sizes has been carried out since a long back. Gaseous ions of different nature are being used in different field of research as well as industrial applications like surface modification, doping, surface etching, sputtering, production of nano size particles and focused ion beam etc. Out of various geometry and operation regime, due to compactness, ruggedness and long life, penning type ion sources are widely used in different field of research and applications. One such type of ion source was developed in our laboratory. Though this source was meant for neutron generation, using deuterium ions, the effectiveness for other purposes was investigated. The discharge characteristic was studied for different gases like, Deuterium, Helium, Nitrogen, Oxygen and Argon. The source being a self extracted type; the extracted ion current from the extraction aperture was measured using one faraday cup. In this paper we have discussed, the discharge characteristic and the extraction ion current for different type of gases.

07 ISOTOPE AND RADIATION SOURCES↗

Interstitial and interlayer ion diffusion geometry extraction in graphitic nanosphere battery materials

Large-scale molecular dynamics (MD) simulations are commonly used for simulating the synthesis and ion diffusion of battery materials. A good battery anode material is determined by its capacity to store ion or other diffusers. However, modeling of ion diffusion dynamics and transport properties at large length and long time scales would be impossible with current MD codes. To analyze the fundamental properties of these materials, therefore, we turn to geometric and topological analysis of their structure. In this paper, we apply a novel technique inspired by discrete Morse theory to the Delaunay triangulation of the simulated geometry of a thermally annealed carbon nanosphere. We utilize our computed structures to drive further geometric analysis to extract the interstitial diffusion structure as a single mesh. Lastly, our results provide a new approach to analyze the geometry of the simulated carbon nanosphere, and new insights into the role of carbon defect size and distribution in determining the charge capacity and charge dynamics of these carbon based battery materials.

25 ENERGY STORAGE↗

An electrostatic autoresonant ion trap mass spectrometer

A new method for ion extraction from an anharmonic electrostatic trap is introduced. Anharmonicity is a common feature of electrostatic traps which can be used for small scale spatial confinement of ions, and this feature is also necessary for autoresonant ion extraction. With the aid of ion trajectory simulations, novel autoresonant trap mass spectrometers (ART-MSs) have been designed based on these very simple principles. A mass resolution {approx}60 is demonstrated for the prototypes discussed here. We report also on the pressure dependencies, and the (mV) rf field strength dependencies of the ART-MS sensitivity. Importantly the new MS designs do not require heavy magnets, tight manufacturing tolerances, introduction of buffer gases, high power rf sources, nor complicated electronics. The designs described here are very inexpensive to implement relative to other instruments, and can be easily miniaturized. Possible applications are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

10 K Ring Electrode Trap - Tandem Mass Spectrometer for Infrared Spectroscopy of Mass Selected Ions

A novel instrumental setup for measuring infrared photodissociation spectra of buffer gas cooled, mass-selected ions is described and tested. It combines a cryogenically cooled, linear radio frequency ion trap with a tandem mass spectrometer, optimally coupling continuous ion sources to pulsed laser experiments. The use of six independently adjustable DC potentials superimposed over the trapping radio frequency field provides control over the ion distribution within, as well as the kinetic energy distribution of the ions extracted from the ion trap. The scheme allows focusing the ions in space and time, such that they can be optimally irradiated by a pulsed, widely tunable infrared photodissociation laser. Ion intensities are monitored with a time-of-flight mass spectrometer mounted orthogonally to the ion trap axis.

74 ATOMIC AND MOLECULAR PHYSICS↗

A composition analyzer for microparticles using a spark ion source

Iron microparticles were fired onto a capacitor-type microparticle detector which responded to an impact with a spark discharge. Ion currents were extracted from the spark and analyzed in a time-of-flight mass spectrometer. The mass spectra showed the element of both detector and particle materials. The total extracted ion currents was typically 10A within a period of 100ns, indicating very efficient vaporization of the particle and ionization of the vapor. Potential applications include research on cosmic dust, atmospheric aerosols and cloud droplets, particles ejected by rocket or jet engines, by machining processes, or by nuclear bomb explosions.

Auer, S. O.↗

Composition analyzer for microparticles using a spark ion source

Iron microparticles were fired onto a capacitor-type microparticle detector which responded to an impact with a spark discharge. Ion currents were extracted from the spark and analyzed in a time-of-flight mass spectrometer. The mass spectra showed the elements of both detector and particle materials. The total extracted ion current was typically 10 A within a period of 100 nsec, indicating very efficient vaporization of the particle and ionization of the vapor. Potential applications include research on cosmic dust, atmospheric aerosols and cloud droplets, particles ejected by rocket or jet engines, by machining processes or by nuclear bomb explosions.

Auer, S.↗

Improved ion containment using a ring-cusp ion thruster

A 30-centimeter diameter ring-cusp ion thruster is described which operates at inert gas ion beam currents up to about 7 ampere, with significant improvements in discharge chamber performance over conventional divergent-field thrusters. The thruster has strong boundary ring-cusp magnetic fields, a diverging field on the cathode region, and a nearly field-free volume upstream of the ion extraction system. Minimum ion beam production costs of 90 to 100 watts per beam ampere (W/A) were obtained for argon, krypton and xenon. Propellant efficiencies in excess of 0.90 were achieved at 100 to 120 W/A for the three inert gases. The ion beam charge-state was documented with a collimating mass spectrometer probe to allow evaluation of overall thruster efficiencies.

Sovey, J. S.↗

Characterization of hollow cathode, ring cusp discharge chambers

An experimental study into the effects of changes in such physical design parameters as hollow cathode position, anode position and ring cusp magnetic field configuration and strength on discharge chamber performance, is described. The results are presented in terms of comparative plasma ion energy cost, extracted ion fraction and ion beam profile data. Such comparisons are used to demonstrate specific means by which changes in these design parameters induce changes in performance, i.e., through changes in the loss rates of primary electrons to the anode, of ions to discharge chamber walls or of ions to cathode and anode surfaces. Results show: (1) the rate of primary electron loss to the anode decreases as the anode is moved downstream of the ring cusp toward the screen grid, (2) the loss rate of ions to hollow cathode surfaces are excessive if the cathode is located upstream of a point of peak magnetic flux density on the discharge chamber centerline, and (3) the fraction of the ions produced that are lost to discharge chamber walls and ring magnet surfaces is reduced by positioning the magnet rings so the plasma density is uniform over the grid surface and so there are no steep magnetic flux density gradients near the walls through which ions can be lost by Bohm diffusion. The uniformity of the plasma density at the grids can also be improved by moving the point of primary electron injection into the discharge chamber off of the chamber centerline. Other results show the discharge chamber losses decrease when a filament cathode is substituted for a hollow cathode to the extent of the hollow cathode operating power. When plasma ion energy cost is determined in such a way that the cost of operating the hollow cathode is subtracted out, the performance using either electron source is similar.

Vaughn, Jason A.↗

Ring cusp/hollow cathode discharge chamber performance studies

An experimental study was performed to determine the effects of hollow cathode position, anode position, and ring cusp magnetic field configuration and strength on discharge chamber performance. The results are presented in terms of comparative plasma ion energy cost, extracted ion fraction, and beam profile data. Such comparisons are used to demonstrate whether changes in performance are caused by changes in the loss rate of primary electrons to the anode or the loss rate of ions to discharge chamber walls or cathode and anode surfaces. Results show: (1) the rate of primary electron loss to the anode decreases as the anode is moved downstream of the ring cusp toward the screen grid; (2) the loss rate of ions to hollow cathode surfaces are excessive if the cathode is located upstream of a point of peak magnetic flux density at the discharge chamber centerline; and (3) the fraction of the ions produced that are lost to discharge chamber walls and ring magnet surfaces is reduced by positioning of the magnet rings so the plasma density is uniform over the grid surface, and adjusting their strength to a level where it is sufficient to prevent excessive ion losses by Bohm diffusion.

Vaughn, J. A.↗

Ring cusp/hollow cathode discharge chamber performance studies

An experimental study performed to determine the effects of hollow cathode position, anode position, and ring cusp magnetic field configuration and strength on discharge chamber performance is described. The results are presented in terms of comparative plasma ion energy cost, extracted ion fraction, and beam profile data. Results show that the rate of primary electron loss to the anode decreases as the anode is moved downstream of the ring cusp toward the screen grid and that the loss rate of ions to hollow cathode surfaces are excessive if the cathode is located upstream of a point of peak magnetic flux density at the discharge chamber centerline. Moreover, the fraction of the ions produced that are lost to discharge chamber walls and ring magnet surfaces is reduced by positioning of the magnet rings so the plasma density is uniform over the grid surface, and adjusting their strength to a level where it is sufficient to prevent excessive ion losses by Bohm diffusion.

Vaughn, J. A.↗

Characterization of ion accelerating systems on NASA LeRC's ion thrusters

An investigation is conducted regarding ion-accelerating systems for two NASA thrusters to study the limits of ion-extraction capability or perveance. A total of nine two-grid ion-accelerating systems are tested with the 30- and 50-cm-diam ring-cusp inert-gas ion thrusters emphasizing the extension of ion-extraction. The vacuum-tank testing is described using xenon, krypton, and argon propellants, and thruster performance is computed with attention given to theoretical design considerations. Reductions in perveance are noted with decreasing accelerator-hole-to-screen-hole diameter ratios. Perveance values vary indirectly with the ratio of discharge voltage to total accelerating voltage, and screen/accelerator electrode hole-pair alignment is also found to contribute to perveance values.

Rawlin, Vincent K.↗

2013 GASEOUS IONS GORDON RESEARCH CONFERENCE, FEBRUARY 24 - MARCH 1, 2013

The Gaseous Ions: Structures, Energetics and Reactions Gordon Research Conference will focus on ions and their interactions with molecules, surfaces, electrons, and light. The long-standing goal of our community is to develop new strategies for capturing complex molecular architectures as gas phase ions where they can be isolated, characterized and manipulated with great sensitivity. Emergent areas of interest include catalytic mechanisms, cryogenic processing of ions extracted from solution, ion fragmentation mechanisms, and new methods for ion formation and structural characterization. The conference will cover theoretical and experimental advances on systems ranging from model studies at the molecular scale to preparation of nanomaterials and characterization of large biological molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗