Engineering PapersSearch

NASA NTRS · 19760028802

Composition analyzer for microparticles using a spark ion source

Abstract

Iron microparticles were fired onto a capacitor-type microparticle detector which responded to an impact with a spark discharge. Ion currents were extracted from the spark and analyzed in a time-of-flight mass spectrometer. The mass spectra showed the elements of both detector and particle materials. The total extracted ion current was typically 10 A within a period of 100 nsec, indicating very efficient vaporization of the particle and ionization of the vapor. Potential applications include research on cosmic dust, atmospheric aerosols and cloud droplets, particles ejected by rocket or jet engines, by machining processes or by nuclear bomb explosions.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Auer, S., Berg, O. E.. 1975-11-01. Composition analyzer for microparticles using a spark ion source. https://ntrs.nasa.gov/citations/19760028802