Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electromagnetic calorimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Geant4 Event Biasing and Fast Simulation

Geant4 offers advanced event biasing techniques to significantly accelerate simulations involving rare events. Various biasing methods, such as leading particle selection, cross-section biasing, radioactive decay enhancement, and bremsstrahlung splitting, enable efficient event sampling, though they require careful handling. Additionally, Geant4 provides a Fast Simulation Interface, allowing the replacement of standard processes in specific region and for selected particles, enabling faster execution or external code integration. Applications of fast simulation include electromagnetic shower modeling in calorimeters, machine learning inference, and offloading tasks to specialized hardware like GPUs, making Geant4 a powerful tool for computationally demanding simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Construction and commissioning of CMS CE prototype silicon modules

As part of its HL-LHC upgrade program, the CMS collaboration is developing a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CEE) and hadronic (CE-H) compartments. The calorimeter will be built with ~30,000 hexagonal silicon modules. Prototype modules have been constructed with 6-inch hexagonal silicon sensors with cell areas of 1.1 cm 2 , and the SKIROC2-CMS readout ASIC. Beam tests of different sampling configurations were conducted with the prototype modules at DESY and CERN in 2017 and 2018. This paper describes the construction and commissioning of the CE calorimeter prototype, the silicon modules used in the construction, their basic performance, and the methods used for their calibration.

Calorimeters↗

Dual Readout in Homogenous Inorganic Scintillators for Precision Calorimeters

Homogeneous inorganic scintillator-based calorimeters are the gold standard for electromagnetic energy resolution, but often degrade the hadronic energy resolution achievable at colliders. By incorporating the dual readout technique, we seek to improve the hadronic energy resolution of these calorimeters through the measurement and separation of the scintillation and Cherenkov light in hadronic showers. In April 2024, CalVision performed single-crystal tests using the electron test beam at DESY. Using a single delay line technique for waveform analysis, sufficient cerenkov light can be extracted to fully capitalize on the dual readout technique. This talk will present the results of PWO, BGO, BSO, PbF2, and two novel scintillating glasses.

Anderson, Thomas [Virginia U.]↗

Calibration technique for electromagnetic flowmeters

Thermal calorimetric method is used to calibrate electromagnetic flowmeters for liquid alkali metals. The electromagnetic flowmeter is placed in the liquid metal flow system in series with a thermal calorimeter. Therefore, the calculated flow rate through the calorimeter can be compared directly with the respective electromagnetic flowmeter reading.

Sawochka, S. G.↗

Anomaly detection with flow-based fast calorimeter simulators

Recently, several normalizing flow-based deep generative models have been proposed to accelerate the simulation of calorimeter showers. Using caloflow as an example, we show that these models can simultaneously perform unsupervised anomaly detection with no additional training cost. As a demonstration, we consider electromagnetic showers initiated by one (background) or multiple (signal) photons. The caloflow model is designed to generate single-photon showers, but it also provides access to the shower likelihood. We use this likelihood as an anomaly score and study the showers tagged as being unlikely. As expected, the tagger struggles when the signal photons are nearly collinear but is otherwise effective. This approach is complementary to a supervised classifier trained on only specific signal models using the same low-level calorimeter inputs. While the supervised classifier is also highly effective at unseen signal models, the unsupervised method is more sensitive in certain regions, and, thus, we expect that the ultimate performance will require a combination of these approaches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charge collection and electrical characterization of neutron irradiated silicon pad detectors for the CMS High Granularity Calorimeter

The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$\mu\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 $^\circ$C to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 $^\circ$C. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60$\%$ or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90$\%$ at the lowest fluence, at 600 V. The collected charge close to the fluence of $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$ exceeds 1 fC at voltages beyond 800 V.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search in diphoton and dielectron final states for displaced production of Higgs or Z bosons with the ATLAS detector in s = 13 TeV p p collisions

A search is presented for displaced production of Higgs bosons or Z bosons, originating from the decay of a neutral long-lived particle (LLP) and reconstructed in the decay modes H → γ γ and Z → ee . The analysis uses the full Run 2 dataset of proton-proton collisions delivered by the LHC at an energy of $\sqrt{s}$ = 13 TeV between 2015 and 2018 and recorded by the ATLAS detector, corresponding to an integrated luminosity of 139 fb -1 . Exploiting the capabilities of the ATLAS liquid argon calorimeter to precisely measure the arrival times and trajectories of electromagnetic objects, the analysis searches for the signature of pairs of photons or electrons which arise from a common displaced vertex and which arrive after some delay at the calorimeter. The results are interpreted in a gauge-mediated supersymmetry breaking model with pair-produced Higgsinos that decay to LLPs, and each LLP subsequently decays into either a Higgs boson or a Z boson. The final state includes at least two particles that escape direct detection, giving rise to missing transverse momentum. No significant excess is observed above the background expectation. The results are used to set upper limits on the cross section for Higgsino pair production, up to a $\bar{χ}^0_1$ mass of 369 (704) GeV for decays with 100% branching ratio of $\bar{χ}^0_1$ to Higgs (Z) bosons for a $\bar{χ}^0_1$ lifetime of 2 ns. A model-independent limit is also set on the production of pairs of photons or electrons with a significant delay in arrival at the calorimeter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron irradiation and electrical characterisation of the first 8” silicon pad sensor prototypes for the CMS calorimeter endcap upgrade

As part of its HL-LHC upgrade program, the CMS collaboration is replacing its existing endcap calorimeters with a high-granularity calorimeter (CE). The new calorimeter is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic and hadronic compartments. Due to its compactness, intrinsic time resolution, and radiation hardness, silicon has been chosen as active material for the regions exposed to higher radiation levels. The silicon sensors are fabricated as 20 cm (8”) wide hexagonal wafers and are segmented into several hundred pads which are read out individually. As part of the sensor qualification strategy, 8” sensor irradiation with neutrons has been conducted at the Rhode Island Nuclear Science Center (RINSC) and followed by their electrical characterisation in 2020-21. The completion of this important milestone in the CE's R&D program is documented in this paper and it provides detailed account of the associated infrastructure and procedures.The results on the electrical properties of the irradiated CE silicon sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The GlueX beamline and detector

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μs$. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. Here, we describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray film chamber with carbon target of Tien-Shan complex array

X-ray films were exposed inside the ionization calorimeter under 74g/sq cm of carbon and 5 cm of lead. The X-ray film chamber area is 35 sq. m. Moving X-ray films were used, 50% of the events, which succeeded to determine incidence time, were identified with corresponding extensive air showers (EAS). For such events the size spectrum of associated EAS was derived. Two methods of energy measurement using X-ray films and ionization calorimeter were compared. The energy transfer from selected hadron to electromagnetic component is illustrated. It is found that in cascades with high energy release into electromagnetic components the hadron component is practically absent.

Cherdyntseva, K. V.↗

Performance of the Pair Spectrometer in Hall D at Jefferson Lab

This article describes the performance of the pair spectrometer installed in experimental Hall D at Jefferson Lab and its successfully operation in multiple experiments with the GlueX detector. The primary purpose of the pair spectrometer is the precise determination of the flux of beam photons incident on the GlueX target, a critical input for physics analyses such as absolute cross-section measurements. The photon energy spectrum is determined by reconstructing electron–positron pairs produced in a thin converter inserted into the photon beam. The spectrometer is integrated into the GlueX trigger system, whose electronics enable continuous real-time monitoring of the photon flux and the recording of e+e- pair candidates for offline analysis. In addition, the pair spectrometer provides a versatile test facility for evaluating calorimeter prototypes using leptons with well-defined energies produced via electromagnetic pair production.

Somov, Alexander [Jefferson Lab]↗

Monte-Carlo Simulations of the Suzaku-XRS Residual Background Spectrum

Cryogenic micro-calorimeters are suitable to detect small amounts of energy deposited by electromagnetic and nuclear interactions, which makes them attractive in a variety of applications on ground and in space. The only X-ray microcalorimeter that operated in orbit to date is the X-Ray Spectrometer on-board of the Japanese Suzaku satellite. We discuss the analysis of the components of its residual background spectrum with the support of Monte-Carlo simulations.

X-ray↗

Installation for the study of the angular distribution of cosmic muons with super-high energies at large zenith angles

An installation consisting of an ionization calorimeter and a counter hodoscope can be used to record cascade showers caused by the electromagnetic interactions of muons with superhigh energies in the cosmic ray horizontal flux. The direction of the muons is determined by a hodoscope consisting of 2196 counters. The information obtained makes it possible to restore the angular and energy distribution of the cosmic muons, which, in turn, makes it possible to determine the mechanism of their generation. The accuracy with which the angle of the passing particle is determined is discussed in detail in addition to the causes which can introduce distortions, such as shower accompaniment of neutrons, escape of shower electrons from the calorimeter, random coincidences, etc.

Borog, V. V.↗

The beam test of the lead tungstate calorimeter prototype with SiPM readout at Jefferson Lab

The lead tungstate crystals (PWO4) are a well-known radiator material for precise homogeneous electromagnetic calorimetry. In nuclear physics experiments, the typical way to read out the crystals is using conventional photomultiplier tubes (PMTs). In the case of the presence of a magnetic field, such a method has some complications and requires a passive PMT shielding design. The recent development of Silicon Photomultipliers (SiPMs) with small pixel pitch sizes and relatively small noise levels opens an opportunity avenue to use such a device as an alternative to conventional PMTs. The SiPM readout method may be beneficial for future nuclear physics and collider experiments. We are presenting the beam test results of the calorimeter prototype instrumented with SiPM readout performed at Jefferson Lab. The SiPM readout performance was compared with PMT readout measured at the same experimental conditions. The prototype was successfully tested using beam of photons in the energy range between 3 GeV and 11 GeV in experimental Hall D. The detector performance was also studied using a secondary beam of positrons provided by Hall D pair spectrometer.

Berdnikov, Vladimir↗

The Heavy Photon Search (HPS) Software Environment

The Heavy Photon Search (HPS) is an experiment at the Thomas Jefferson National Accelerator Facility (JLab) designed to search for a hidden sector photon (A’) in fixed-target electro-production. It uses a silicon microstrip tracking and vertexing detector placed inside a dipole magnet to measure charged particle trajectories and a fast lead-tungstate crystal calorimeter located just downstream of the magnet to provide a trigger and to identify electromagnetic showers. The HPS experiment uses both invariant mass and secondary vertex signatures to search for the A’. The experimental collaboration is small and quite heterogeneous: it is composed of members of the nuclear physics as well as particle physics communities, from universities and national labs from around the US and Europe. Enabling such a disparate group to concentrate on the physics aspects of the experiment required that the software be easy to install and use, and having such limited manpower meant that existing solutions had to be exploited. HPS has successfully completed two engineering runs and completed its first physics run in the summer of 2019. We begin with an overview of the physics goals of the experiment followed by a short description of the detector design. We then describe the software tools used to design the detector layout and simulate the expected detector performance. Event reconstruction involving track, cluster and vertex finding and fitting for both simulated and real data was, to first order, adopted from existing software originally developed for Linear Collider studies. Bringing it all together into a cohesive whole involved the use of multiple software solutions with common interfaces.

Graf, Norman↗

Report on High Energy Arcing Fault Experiments: Experimental Results from Low-Voltage Switchgear Enclosures

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for low-voltage metal enclosed switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers experiments performed on two low-voltage switchgear units with each unit consisting of two vertical sections. The data collected supports characterization of the low-voltage HEAF hazard and these results will be used to support potential improvements in fire probabilistic risk assessment (PRA) methods. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 26 and Augsut 29, 2019 on nearidentical Westinghouse Type DS low-voltage metal-enclosed indoor switchgear. The threephase arcing fault was initiated on the aluminum main bus or in select cases on the copper bus stabs near the breaker. These experiments used either nominal 480 volts AC or 600 volts AC. Durations of the experiments ranged from approximately 0.4 s to 8.3 s with fault currents ranging from approximately 9.2 kA to 19.3 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. Environmental measurements of breakdown, conductivity and electromagnetics were also taken. The experiments were documented with normal and high-speed videography, infrared imaging and photography. The results, while limited, indicated the difficulty in maintaining and sustaining low-voltage arcs on aluminum components of sufficient duration and at a single point as observed operating experience.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Self-compensating light calorimetry with liquid argon time projection chamber for GeV neutrino physics

The Liquid Argon Time Projection Chamber (LArTPC) is a powerful dual calorimeter capable of estimating particle energy from both ionization charge and scintillation light. Here, our study shows that, due to the recombination luminescence, the LArTPC functions as a self-compensating light calorimeter: the missing energy in the hadronic component is compensated for by the increased luminescence relative to the electromagnetic component. Using 0.5-5 GeV electron neutrino charged current interactions as a case study, we show that good compensation of the electron-to-hadron response ratio (e/h) from 1-1.05 can be achieved across a broad range of drift electric fields (0.2-1.8 kV / cm), with better performance for neutrino energies above 2 GeV. This study highlights the potential of light calorimetry in LArTPCs for GeV neutrino energy reconstruction, complementing traditional charge calorimetry. Under ideal conditions of uniform light collection, we show that LArTPC light calorimetry can achieve an energy resolution comparable to the charge imaging calorimetry. Challenges arising from nonuniform light collection in large LArTPCs can be mitigated with a position-dependent light yield correction derived from 3D charge signal imaging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CALET Search for Electromagnetic Counterparts of Gravitational Waves during the LIGO/Virgo O3 Run

The CALorimetric Electron Telescope (CALET) on the International Space Station consists of a high-energy cosmic-ray CALorimeter (CAL) and a lower-energy CALET Gamma-ray Burst Monitor (CGBM). CAL is sensitive to electrons up to 20 TeV, cosmic-ray nuclei from Z = 1 through Z ~ 40, and gamma rays over the range 1 GeV–10 TeV. CGBM observes gamma rays from 7 keV to 20 MeV. The combined CAL-CGBM instrument has conducted a search for gamma-ray bursts (GRBs) since 2015 October. We report here on the results of a search for X-ray/gamma-ray counterparts to gravitational-wave events reported during the LIGO/Virgo observing run O3. No events have been detected that pass all acceptance criteria. We describe the components, performance, and triggering algorithms of the CGBM—the two Hard X-ray Monitors consisting of LaBr 3 (Ce) scintillators sensitive to 7 keV–1 MeV gamma rays and a Soft Gamma-ray Monitor BGO scintillator sensitive to 40 keV–20 MeV—and the high-energy CAL consisting of a charge detection module, imaging calorimeter, and the fully active total absorption calorimeter. The analysis procedure is described and upper limits to the time-averaged fluxes are presented.

79 ASTRONOMY AND ASTROPHYSICS↗