Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Brayton cycle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

142 records · Page 8

Pilot Development Progress to Demonstrate Electric Thermal Energy Storage (ETES) Using Low-Cost Particles

The rapid growth of future energy demand increases the need to economically store electrical energy over durations up to several days in long-duration energy storage (LDES) applications. LDES can reduce the grid stress for improving the resilience of the grid. The integration of renewable power and storage has several significant and positive impacts including expanding the renewable energy portion of electricity generation, meeting peak-load demand, and coordinating supply and demand. Several energy storage approaches including mechanical, chemical and electrochemical methods are currently deployed or under development. However, LDES requirements pose unique challenges for scalability, energy capacity, and cost. Thermal energy storage (TES) has the ability to store a large capacity of energy with improved site flexibility compared to incumbent LDES technologies (i.e., pumped hydro) and has attracted significant interest. Our development in TES technology using solid particles as the storage medium has shown feasibility and potential in serving LDES purposes. Particle TES has various advantages over commercialized molten nitrate salt TES and has emerged as a promising storage technology originating from Generation 3 concentrating solar power (CSP) development. Stable, inexpensive silica sand produced in the Midwestern U.S. was identified as a suitable storage medium and has been validated through lab heating and cycling tests. We have successfully developed particle TES for bidirectional electric energy storage to broaden the applications for TES beyond CSP technologies and into standalone electric-thermal energy storage (ETES) systems. Key component designs and performance were verified with prototype testing and model simulations. The ETES system uses high-temperature, low-cost particle thermal energy storage coupled with a unique pressurized fluidized bed heat exchanger that supports a high-efficiency, air-Brayton combined power cycle. At times of low energy demand or high renewable production, an electric particle heater heats large quantities of solid particles to high temperatures in excess of 1100 degrees C. The particles are stored in internally insulated silos. At times of high electricity demand, the hot particles are gravity-fed through the heat exchanger where stored thermal energy is transferred to the power cycle working fluid to drive the gas turbine power generation system, thereby converting the thermal energy back into electricity for the grid. The cold particles leaving the heat exchanger are returned to the storage silos by a well-insulated particle conveyor. This ETES technology using particle TES can be sited anywhere and is predicted to be economic and efficient. Moreover, this ETES technology could be co-located with a retired coal or gas plant to leverage existing power generation and grid infrastructure. Our work has focused on the development of each of the key components (e.g., the electric particle heater, particle storage silos, and the particle-to-gas pressurized fluidized bed heat exchanger) through conceptual designs, prototype testing, and computational modeling. These developments demonstrate technological feasibility and are an important step towards the next phase of development of this promising LDES technology. This presentation will show the progress in developing a pilot demonstration of the ETES system on a commercially relevant scale.

25 ENERGY STORAGE↗

System and component development for long-duration energy storage using particle thermal energy storage

Energy storage, at various scales, will be required to maintain reliable power supply from variable renewable resources, and improve grid resilience. Long-duration energy storage (10-100 h) can substitute baseload coal power generation and increase levels of renewable power supply. Thermal energy storage (TES) has siting flexibility and the ability to store a large capacity of energy, and thus it has the potential to meet the needs of long-duration energy storage. Here, a novel TES system was developed by using solid particles as storage media and charging/discharging electricity from renewable power connected via the electric grid. The particle TES uses low-cost silica sand at 30-40$/Ton that is stable at high temperatures of >1,000 degrees C. Thus, the particle TES system has an overall low storage cost and high thermal-power efficiency. Key components of the system were conceptually designed and modeled for their performance. Conversion of electricity to thermal energy using electric heating can achieve a >98% charging efficiency, and the conversion of thermal energy back to electricity uses an air-Brayton combined power cycle with >52% thermal-to-electricity efficiency at >1,170 degrees C to achieve a >50% roundtrip efficiency after subtracting estimated plant parasitic losses. Laboratory-scale prototypes were fabricated and tested to verify their design approaches and operations relevant to product-scale components.

25 ENERGY STORAGE↗

ANL Design Team Analysis: Transportable Modular Reactor by Balance of Plant Elimination

HolosGen LLC is developing “Holos-Quad” a transportable gas-cooled reactor, with integral load following power conversion systems equipping subcritical power modules (SPMs), fully comprised within standard transport containers. The design eliminates the Balance of Plant (BoP) and greatly simplifies the design layout. A closed-loop full Brayton gas thermodynamic cycle converts the fuel cartridges thermal energy into electricity. This ARPA-E project utilizes advanced reactor modeling tools and manufacturing-testing of a scaled SPM equipped with a surrogate fuel cartridge to eliminate the most significant technology gaps to accelerate commercialization. The Argonne Design Team contributes to the research by demonstrating feasibility of various aspects of the Holos-Quad design by performing high-fidelity neutronic modeling, and investigating various reactivity control systems. This work consists of two main tasks: evaluation of HolosGen’s design features and alternative options study for reactivity control.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling a Water-Cooled Printed Circuit Heat Exchanger Condensing CO2 for use in SCO2 Cycle System Optimization Studies

This work describes a one-dimensional model of a water-cooled printed circuit heat exchanger (PCHE) condensing supercritical CO2. The model is developed for use in cycle optimization studies (e.g., minimizing levelized cost of electricity) as either the main heat rejection cooler and/or a compressor intercooler for recompression closed Brayton supercritical CO2 power cycles. Sensitivity and case studies are used to illustrate the impact of important model parameters, and this includes allowing for independent variation of zig-zag channel wave angles on the CO2 and water side. Results show that for a given CO2 design pressure (and thus saturation temperature), the PCHE design inlet water temperature has a significant impact on the PCHE size. Results also demonstrate that if wave angles are the same on the CO2 and water side, the water side pressure drop will have more influence on determining the optimum PCHE mass than the CO2 side pressure drop. Reducing the water side wave angle to near straight channel flow offers a more compact design for a similar water side pressure drop (and pump power requirement). Cases are also shown for further increasing the compactness and how the PCHE mass is affected along with water pump power.

Liese, Eric↗

Novel Modular Heat Engines with sCO 2 Bottoming Cycle Utilizing Advanced Oil-Free Turbomachinery

This report presents the thermal, mechanical, and electric machine design of a 27krpm rotating test rig aimed at reducing technical risks with hermetic oil-free super-critical carbon dioxide (sCO 2 ) turbomachinery. The test rig rotor system is based on a conceptual turbomachine design discussed that evaluates a sCO 2 waste heat recovery (WHR) unit for land-based gas turbines at natural gas (NG) compressor stations. The key novelty of the hermetic sCO 2 turbomachine concept is the utilization of additively manufactured CO 2 gas bearings and a CO 2 -immersed direct-drive permanent magnet (PM) electric machine. The previous effort on conceptual design identified 3 main technical risks, which included thrust bearing load capacity, rotordynamics, and thermal performance of the system. Therefore, key requirements of the test vehicle include the ability to test the rotor system in a 400psi (27.6 bar) hermetic CO 2 operating environment, apply up to 1,500 lbs (6.7 kN) of rotor thrust loads, capability to assess rotordynamics with radial gas bearings, inclusion of instrumentation to assess thrust bearing load capability, and flexibility for varying secondary cooling flows to confirm thermal model predictions. Design topics such as rotordynamics, bearing design, and electric machine design are addressed, while highlighting critical elements. In addition, additive build trials for Inconel 718 radial and thrust bearings were performed to prove the manufacturability of the bearing design concepts. The results of the design efforts yield a test rig concept with ability to operate at 27,000 rpm, apply thrust loads to 1,500 lbs, deliver CO 2 up to 800psi, and modulate cooling flows.

03 NATURAL GAS↗

High Effectiveness, Compact, High Pressure and Low-Cost Recuperator, Presented at The Fifth International Symposium – Super-Critical CO2 Power Cycles, San Antonio, Texas, March 28-31, 2016, by Dr. John Kelly, President, Altex Technologies Corporation

Closed Brayton super-critical CO2 power cycles are well suited to waste heat bottoming cycles, due to their increased efficiency and compactness, relative to Rankine steam bottoming cycles. Since waste heat applications would be retrofits, the power system compactness is important. To achieve high efficiency, these power cycles require high pressure recuperative type heat exchangers, of substantial heat duty. Current Printed Circuit Heat Exchangers (PCHE), originally developed for high pressure gas and oil applications, can be used as recuperators, but costs are higher than desired. Altex is developing a purpose-built high pressure and effectiveness recuperator to provide the reliability, compactness, performance and pressure capability of current recuperators, but at a reduced cost. The High Effectiveness Low Cost (HELC) recuperative heat exchanger design yields volume and weight metrics of .0024 m3/UA and 10.2 kg/UA, which are 4% and 77.3% below recuperator target metrics, respectively. A 50 kW test article was designed and fabricated. Performance tests on water and oil showed that the HELC design model could predict heat transfer, to within 10% of the measured value. This model was then used to project HELC performance, when operating on supercritical CO2. Besides performance tests, the test article was hydrostatically tested, for integrity at up to 4,000 psi pressure. At these conditions, some distortion of channels was encountered. To mitigate distortion, the inserts were redesigned and these results were used to project the cost of 500 kW and 5,083 kW HELC units. The cost metric for the 5,083 kW unit was determined to be $1,349/UA, which is 10% lower than the recuperator desired cost metric desired target of $1,500/UA. In addition, the 5,083 kW unit HELC cost of $61.09/kW is 33.6% lower than the $92/kW estimated cost for a PCHE. Hydrostatic pressure tests, at up to 4,000psi, showed that the unit did not leak. However, channels were distorted at this pressure differential. Design updates to minimize stress concentrations and distortion were prepared and analyzed, to show that distortion could be controlled, but to date tests have not been run to prove the design. Project results show the potential of the HELC approach, but more work is required to confirm this potential, at the larger scales of interest.

14 SOLAR ENERGY↗

High Effectiveness, Compact, High Pressure and Low Cost Recuperator for Super-Critical CO2 Power Cycles, Paper Presented at The Fifth International Symposium – Super-Critical CO2 Power Cycles, San Antonio, Texas, March 28-31, 2016, by Dr. John Kelly, President, Altex Technologies Corporation

Closed Brayton super-critical CO2 power cycles are well suited to waste heat bottoming cycles, due to their increased efficiency and compactness, relative to Rankine steam bottoming cycles. Since waste heat applications would be retrofits, the power system compactness is important. To achieve high efficiency, these power cycles require high pressure recuperative type heat exchangers, of substantial heat duty. Current Printed Circuit Heat Exchangers (PCHE), originally developed for high pressure gas and oil applications, can be used as recuperators, but costs are higher than desired. Altex is developing a purpose-built high pressure and effectiveness recuperator to provide the reliability, compactness, performance and pressure capability of current recuperators, but at a reduced cost. The High Effectiveness Low Cost (HELC) recuperative heat exchanger design yields volume and weight metrics of .0024 m3/UA and 10.2 kg/UA, which are 4% and 77.3% below recuperator target metrics, respectively. A 50 kW test article was designed and fabricated. Performance tests on water and oil showed that the HELC design model could predict heat transfer, to within 10% of the measured value. This model was then used to project HELC performance, when operating on supercritical CO2. Besides performance tests, the test article was hydrostatically tested, for integrity at up to 4,000 psi pressure. At these conditions, some distortion of channels was encountered. To mitigate distortion, the inserts were redesigned and these results were used to project the cost of 500 kW and 5,083 kW HELC units. The cost metric for the 5,083 kW unit was determined to be $1,349/UA, which is 10% lower than the recuperator desired cost metric desired target of $1,500/UA. In addition, the 5,083 kW unit HELC cost of $61.09/kW is 33.6% lower than the $92/kW estimated cost for a PCHE. Hydrostatic pressure tests, at up to 4,000psi, showed that the unit did not leak. However, channels were distorted at this pressure differential. Design updates to minimize stress concentrations and distortion were prepared and analyzed, to show that distortion could be controlled, but to date tests have not been run to prove the design. Project results show the potential of the HELC approach, but more work is required to confirm this potential, at the larger scales of interest.

14 SOLAR ENERGY↗

sCO 2 Brayton Energy Conversion Customer Discovery

All energy production systems need efficient energy conversion systems. Current Rankine cycles use water to generate steam at temperatures where efficiency is limited to around 40%. As existing fossil and nuclear power plants are decommissioned due to end of effective life and/or societies’ desire for cleaner generation options, more efficient energy conversion is needed to keep up with increasing electricity demands. Modern energy generation technologies, such as advanced nuclear reactors and concentrated solar, coupled to high efficiency sCO 2 conversion systems provide a solution to efficient, clean energy systems. Leading R&D communities worldwide agree that the successful development of sCO 2 Brayton power cycle technology will eventually bring about large-scale changes to existing multi-billion-dollar global markets and enable power applications not currently possible or economically justifiable. However, all new technologies face challenges in the path to commercialization and the electricity sector is distinctively risk averse. The Sandia sCO 2 Brayton team needs to better understand what the electricity sector needs in terms of new technology risk mitigation, generation efficiency, reliability improvements above current technology, and cost requirements which would make new technology adoption worthwhile. Relying on the R&D community consensus that a sCO 2 power cycle will increase the revenue of the electrical industry, without addressing the electrical industry’s concerns, significantly decreases the potential for adoption at commercial scale. With a clear understanding of the market perspectives on technology adoption, including military, private sector, and utilities customers, the Sandia Brayton Team can resolve industry concerns for smoother development and faster transition to commercialization. An extensive customer discovery process, similar to that executed through the NSF’s I-Corp program, is necessary in order to understand the pain points of the market and articulate the value proposition of Brayton systems in terms that engage decision makers and facilitate commercialization of the technology.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Supercritical CO2 Recuperators, Presented at The ASME Turbo Expo 2017, June 29, 2017, by Dr. John Kelly, President, Altex Technologies Corporation

Closed Brayton super-critical CO2 power cycles are well suited to waste heat bottoming cycles, due to their increased efficiency and compactness, relative to Rankine steam bottoming cycles. Since waste heat applications would be retrofits, the power system compactness is important. To achieve high efficiency, these power cycles require high pressure recuperative type heat exchangers, of substantial heat duty. Current Printed Circuit Heat Exchangers (PCHE), originally developed for high pressure gas and oil applications, can be used as recuperators, but costs are higher than desired. Altex is developing a purpose-built high pressure and effectiveness recuperator to provide the reliability, compactness, performance and pressure capability of current recuperators, but at a reduced cost. The High Effectiveness Low Cost (HELC) recuperative heat exchanger design yields volume and weight metrics of .0024 m3/UA and 10.2 kg/UA, which are 4% and 77.3% below recuperator target metrics, respectively. A 50 kW test article was designed and fabricated. Performance tests on water and oil showed that the HELC design model could predict heat transfer, to within 10% of the measured value. This model was then used to project HELC performance, when operating on supercritical CO2. Besides performance tests, the test article was hydrostatically tested, for integrity at up to 4,000 psi pressure. At these conditions, some distortion of channels was encountered. To mitigate distortion, the inserts were redesigned and these results were used to project the cost of 500 kW and 5,083 kW HELC units. The cost metric for the 5,083 kW unit was determined to be $1,349/UA, which is 10% lower than the recuperator desired cost metric desired target of $1,500/UA. In addition, the 5,083 kW unit HELC cost of $61.09/kW is 33.6% lower than the $92/kW estimated cost for a PCHE. Hydrostatic pressure tests, at up to 4,000psi, showed that the unit did not leak. However, channels were distorted at this pressure differential. Design updates to minimize stress concentrations and distortion were prepared and analyzed, to show that distortion could be controlled, but to date tests have not been run to prove the design. Project results show the potential of the HELC approach, but more work is required to confirm this potential, at the larger scales of interest.

14 SOLAR ENERGY↗

Integrated Heat Exchanger-Phase Change Material Thermal Energy Storage System

The purpose of this study is to experimentally investigate the thermal performance of an innovative thermal energy storage (TES) system that combines the advantages of the phase-change material (PCM)/graphite foam latent heat TES medium developed at Argonne National Laboratory (Argonne) and the internally supported plate-fin (ISPE) cell architecture heat transfer fluid (HTF) flow channels developed at Brayton Energy (Brayton). Several essential tasks were accomplished: (1) Thermal property characterization. Thermal properties of the graphite foam were characterized, providing necessary data for experimental result analysis and numerical simulation. (2) Design and optimization of lab-scale test module. Based on Brayton’s full-scale heat exchanger (HX)-TES system, the experimental test module was designed, optimized, and fabricated. (3) Thermal performance testing and data analysis. Five cycle tests were successfully conducted—including one with approximately 3.5 psig of pressure applied to the diaphragms—to investigate the thermal performance of the experimental test module for charging and discharging. Temperature profiles were generated for each charging test and discharging test as a function of time. The temperature profiles clearly show three TES stages: sensible heat (temperature increase), latent heat (melting), and sensible heat (temperature increase) for the charging process. Similarly, the temperature profiles clearly show three thermal energy release stages: sensible heat (temperature decrease), latent heat (solidification), and sensible heat (temperature decrease). Melting and solidification of the PCM generally occurred in relatively narrow temperature ranges, indicated by the flattened temperature regions in the temperature profiles. These phase changes ranged approximately 3°C for melting and 3.5°C for solidification. The charging and discharging temperature profiles were similar for similar experimental parameter tests whether or not pressure was applied to the diaphragm to eliminate the gap between the HX surface and the TES subsystem. This indicates that the effect of a small gap between the HX surface and the TES subsystem is insignificant for charging and discharging. (4) Comparison of experimental data and simulation results. We compared the experimental data to the numerical simulation results. Numerical simulations were conducted by using the ANSYS FLUENT 2019 R3 commercial computational fluid dynamics software. The predicted phase-change times agreed reasonably well with those from the experimental data. In most cases, the estimated time differences between the relative phase changes were within 16%. The predicted start and end times for the charging process agreed well with those from the experimental data. However, the simulation results showed earlier start and end times than the experimental data for the discharging process. Overall, the experimental data and its comparison with the simulation predictions verified the technical viability of the integrated ISPF HX-PCM/graphite foam latent-heat TES system.

25 ENERGY STORAGE↗

Modified Calcium Manganites for Thermochemical Energy Storage Applications

CaAl 0.2 Mn 0.8 O 3-δ (CAM28) and CaTi 0.2 Mn 0.8 O 3-δ (CTM28) are perovskite metal oxides developed for high-temperature thermochemical energy storage (TCES) applications, e.g., in support of air Brayton power generation. Previous reports for these compounds focus on the equilibrium non-stoichiometry (δ) as a function of temperature and oxygen partial pressure (pO 2 ) and the endotherm (or exotherm) accompanying changes in δ resulting from thermal reduction (or re-oxidation). Herein, we report results for elemental substitution and doping (Al, Co, Fe, La, Sr, Ti, Y, Zn, and Zr) of calcium manganites (CM) that establish the preference for CAM28 and CTM28. Techniques employed include conventional (screening and equilibrium) and ballistically heated multi-cycle thermogravimetric analysis (TGA), conventional and high temperature ( in-situ ) X-ray diffraction (XRD), and differential scanning calorimetry (DSC). Forward-looking results for A-site Y-doped materials, e.g., Ca 0.9 Y 0.1 MnO 3-δ (CYM910), establish a route to increasing the reduction enthalpy relative to CAM28 and CTM28, albeit at the expense of increased reduction temperatures and raw materials costs. A thermodynamic model presented for CAM28, but extendable to related materials, provides values for the reaction enthalpy and extent of reduction as a function of temperature and oxygen partial pressure for use in design efforts. Taken as a whole, the results support the choice of Al-doped CaMnO 3-δ as a low-cost material for TCES in a high temperature air Brayton application, but point the way to achieving higher stored energy densities that could lead to overall cost savings.

Miller, James E.↗

Solar Receiver with Integrated Thermal Storage for a Supercritical Carbon Dioxide Power Cycle

This project endeavors to design and demonstrate an integrated CSP system that meets the Department of Energy’s 6¢/kW-hr LCOE goal [1]. This design is based on the 10 MWe Supercritical Transformational Electric Power (STEP) engine specifications, but adaptable to any sCO 2 power module up to 10 MW e . The enabling technology to be tested is a new class of metal hydride based thermal energy storage materials which can store thermal energy in the hydrogen bonds between the metal hydride and hydrogen. This thermochemical energy storage solution provides a much greater energy density than sensible and latent energy storage enabling an integrated system design that closely linked the metal hydride to the power block. This allows the entire system to be mounted up tower to provide cost reductions. A novel metal hydride, capable of operating above 760 °C, was developed during the course of this project and thoroughly tested at a lab scale. The material’s hydrogen capacity, reaction enthalpy, thermal conductivity, and cyclic stability were measured. A demonstration test article was built that can store 2kWh of thermal energy and was coupled to Brayton Energy’s CO 2 loop where the performance of the metal hydride under commercial conditions was measured. An integrated model was created that uses the inputs from all the different sub-models in order to return an overall system LCOE using SAM. This project greatly advanced metal hydride based thermochemical energy storage technology and demonstrated its use. Previously there were no metal hydrides which were capable of operating at the proposed temperature limits (760°C), there is now a high temperature metal hydride with documented performance/stability and a path for low-cost production. Additionally, the metal hydride was tested at a scale >650x larger than what had previously been done in the lab. While not at commercial scale, it was an excellent demonstration of the technology and provided knowledge that can be leveraged for other applications.

08 HYDROGEN↗

Creep and Fatigue Characterization of High Strength Alloy Thin Sections in Advanced CO2 Heat Exchangers

The objective of this work was to characterize and model elevated temperature creep and fatigue behavior for thin sheet and foil forms of gamma-prime strengthened alloys in wrought form and as-processed folded and brazed constructions. This work was motivated by the demanding temperature and pressure service conditions of the GEN3 Concentrated Solar Power (CSP) and supercritical CO2 (sCO2) power cycle working fluid. More specifically, the possibility of leveraging the superior creep strength of gamma-prime alloys in folded-fin and brazed-plate heat exchanger constructions. Gamma-prime alloys represent a step-change in raw-material strength over solid-solution strengthened alloys. And the folded-fin and brazed-plate heat exchanger architecture is lightweight and leverages cost-effective material stock forms. The investigation contained two parallel paths. (1) The first is referred to as a fundamental investigation where Oak Ridge National Laboratory conducts uniaxial creep testing on thin sheet and foil in wrought form. This effort aimed to serve as a benchmark against a relatively sparse existing database and a baseline comparison for path number 2. (2) The second path is referred to as the practical investigation where Brayton Energy manufactures plate-fin heat exchangers and performs pressurized creep and fatigue testing. This effort aimed to de-risk heat exchanger manufacturing process for service under sCO2 CSP conditions. A total of 14 uniaxial creep tests were completed using Haynes 282 thin sheet and foil. A variety of heat treatments were specified to coincide with path number 2. Baseline metallography of test samples and creep strength performance are contained. Benchmarks relatively to existing thick-form Haynes 282 are made, as well as to other thin-form Nickel-based superalloys. Description of a wrought-form modeling approach for thin gamma-prime alloys is also discussed. A total of 11 pressurized creep and fatigue tests were completed successfully with Haynes 282 heat exchanger prototypes. Manufacturing processing details, testing details, testing results, and failure analysis are discussed. Additionally, creep modeling techniques to predict failure are discussed, and modeling to support technological-to-market. In conclusion, Haynes 282 foils were demonstrated to yield rupture two-to-three orders of magnitude higher than Haynes 230 foils under similar conditions. And the manufactured heat exchanger prototypes demonstrated strength similar to the wrought constituents. Both of which contribute to elevated performance potential or cost savings in practice. Discussion is included.

14 SOLAR ENERGY↗

Thermodynamically Stable, Plasmonic Transition Metal Oxide Nanoparticle Solar Selective Absorbers towards 95% Optical-to-Thermal Conversion Efficiency at 750 °C

Generation 3 (Gen) concentrating solar power (CSP) systems requires a high operation temperature ≥750°C to increase the power-cycle efficiency towards ≥50%. However, such a high operation temperature poses a notable challenge to high temperature materials. On the receiver side, a critical challenge is the lack of solar selective absorbers that demonstrate both high optical-to-thermal energy conversion efficiency η therm approaching 95% and long-term thermal stability at >750°C in air. Existing solar absorbers either have limited η therm ≤89% or deteriorate significantly within 500 h at 750°C; some of these also require costly vacuum deposition for stringent thickness control. Therefore, it is highly desirable to simultaneously achieve η therm ~95% AND high thermal stability at 750°C for future generations of CSP receivers. This project has investigated and developed low-cost, highly scalable spray-coated transition metal oxide nanoparticle (NP) pigmented solar selective coatings on various types of Inconel alloy tube sections that are thermodynamically stable at 750-800°C in air, maintaining η therm >94.3%(93.2%) under a solar concentration ratio of C=1000 after 60 simulated day-night cycles at 750ºC (800ºC) (1 cycle=12 h at 750 or 800°C and 12h ramping down to 25°C). We have also coated up to 48 inches long receiver tubes for preliminary solar testing under Norwich Technology’s parabolic trough systems, demonstrating notably improved performance in solar heating compared to benchmark Pyromark 2500 coatings. Two key innovations have been developed in this project: (1) We achieved an unprecedented high thermal efficiency >94% by optimizing the d-band optical absorption spectra of transition metal ions, engineering their valences and stoichiometry; (2) We were able to maintain or even slightly increase the efficiency when operating at 750°C in air by engineering the interdiffusion of transition metal ions between the coating and the Inconel substrate to our advantage. Featuring high-temperature solar spectral selectivity and thermodynamic stability in air, as well as low-cost, highly scalable solution-chemical synthesis and spray coating techniques, this innovation in solar selective absorber technology alone accounts for nearly 40% of the targeted reduction in the levelized cost of electricity (LCOE) from the receiver, thermal energy storage, and operation & maintenance combined by 2030, as proposed by the U.S. Department of Energy. For a 110 MWe CSP power plant, this LCOE reduction from the solar selective coating alone transfers to ~$\$ $1.9 M increase in annual profit based on a sales price of 10¢/kWh (or an annual sale of $50 M/year). The high solar absorptance (~98%) NP pigment materials developed in this project are equally applicable to volumetric receivers either as a coating or as bigger ceramic microspheres after sintering, potentially benefiting Gen3 falling particle CSP technologies. All these contributions facilitate the larger scale deployment of CSP systems with energy storage capability to address the intermittency issue of solar energy towards dispatchable solar electricity, bridging the temporal gap between peak solar electricity production and peak electricity consumption. The collaboration with Norwich Technologies and Brayton Energy in this project will also facilitate the future commercialization of this new solar selective coating technology developed in this SIPS project.

14 SOLAR ENERGY↗

Reduced order modeling of a fluidized bed particle receiver for concentrating solar power with thermal energy storage

Oxide particles can serve as both the heat transfer and thermal energy storage (TES) media for next-generation concentrating solar power (CSP) plants where high-temperature TES enables dispatchable electricity from efficient power cycles with firing temperatures above 600 °C. Transferring heat to flowing particles at such high temperatures in a MW-scale central tower receiver remains a challenge for the CSP community. For indirect receivers with external walls to contain the particles, maintaining wall temperatures below the limits of structural metal alloys requires high heat transfer coefficients between the wall and the moving particle stream. Bubbling fluidization of downward-flowing particles can sustain high bed-wall heat transfer coefficients (> 1000 W m -2 K -1 ). Using experimentally calibrated correlations for bed-wall heat transfer and vertical particle dispersion, this study implements an axially discretized zonal model of a counterflow fluidized bed receiver to explore how bubbling fluidization may enable indirect cavity particle receivers. High bed-wall heat transfer coefficients support solar fluxes on angled cavity walls > 200 kW m -2 at peak aperture fluxes of 980 kW m -2 while maintaining external wall temperatures < 950 °C. Lateral particle dispersion enables hotter particles near the receiver leading edge to mix with cooler particles further from the leading edge to lower maximum external wall temperatures. Parametric studies identify how mass fluxes, particle dispersion, and solar concentrations impact indirect receiver thermal efficiency and uniformity for a CSP plant. These studies provide a basis for the design of indirect fluidized-bed cavity receivers that can maintain particle outlet temperatures for TES above 750 °C.

14 SOLAR ENERGY↗

Coatings for CSP Lifetime

The feasibility and performance of tower-technology-based concentrated solar power (CSP) is highly dependent on the efficiency of the energy transformation from sun to heat at the receiver. The higher the solar absorptivity of the receiver coating, the higher the efficiency of the plant as a whole. BrightSource Energy (BSE) has developed a series of High-Performance Coating (HPC) systems in order to achieve high absorptivity over the plant lifetime (25-35 years). This requires stable coatings that are easily applicable on the large receiver surface and will maintain their optical properties under intense solar flux and thousands of heating and cooling cycles in desert conditions. Different coating formulations are required according to the differing plant conditions: receiver materials, operating conditions (temperatures, daily cycles, etc.), and environmental conditions. BSE also developed a coating for the next generation of CSP receivers, such as those being under DOE’s CSP Gen3 program, which will be operated with high temperature heat transfer fluids at temperatures of up to 800°C, which is significantly hotter than the operating temperature of current systems. Once the coating is formulated, the next challenge is evaluating its lifetime properties. BSE has found several independent failure modes that impact HPC absorptivity degradation: • Decrease in HPC optical properties due to oxidation in the receiver tubes surface below the HPC; • HPC film deterioration due to cycling of temperatures and humidity due to daily operation startup and shutdown as well as changing ambient conditions; • Mechanical degradation due to erosion by sand and wind. Existing test methods examine various aspects independently, but do not provide a combined accelerated lifetime result. Creating such a combined test suite, with a way to interpret the results to predict the coating’s projected lifetime, was the ultimate goal of this project. The project was divided into three major workstreams: lab testing (individual failure mode tests and combined failure mode tests); developing a theoretical model for aging; and validation of the test apparatus via on-sun testing in near real-world conditions at CIEMAT-PSA. Developing a test apparatus that accurately controlled the temperature while also introducing the desired solar flux proved more challenging than expected. While in the end we did succeed in creating a test apparatus that can control temperature, solar flux, and humidity, the results did not appear to accelerate the lifetime of the samples as desired. We suspect that to properly accelerate the samples we must also subject the samples to increased amounts of oxygen. Similarly, while we successfully created a combined model that is publicly available, we were unable to validate it sufficiently to feel comfortable recommending it as a general guideline.

14 SOLAR ENERGY↗