Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “risk mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SARS-CoV-2 transmission control in California correctional facilities

LBNL provided technical assistance to the CalPROTECT project, which is a collaboration between the University of California, Berkeley and the University of California, San Francisco. The CalPORTECT team provided support and guidance to the California Department of Corrections and Rehabilitation (CDCR) and the California Correctional Health Care Services (CCHCS) in their response to the COVID-19 pandemic. The CalPROTECT team provided recommendations to mitigate the risk posed to the residents and staff who live and work in CDCR prisons through considering scientific knowledge of the virus, analyzing anonymized resident and staff level data from CCHCS, evaluation of statewide and institution-level policies, and data collection during site visits to CDCR prisons during the pandemic.

59 BASIC BIOLOGICAL SCIENCES↗

A Comprehensive Economic Coal Transition in South Asia

Many countries are considering accelerating their coal transition. A coal transition refers to an energy sector’s shift from a reliance on coal toward an energy mix largely based on cleaner fuels and renewable energy sources. Such a transition is not just related to greenhouse gas emissions, but also encompasses a range of benefits, recognizing that global energy costs and options are changing. Since 2015, proposed new coal power capacity has dropped by three-quarters globally, leaving only a few countries that develop coal-fired power plants at scale (Littlecott et al., 2021). Historic steps were taken at the United Nations Climate Change 26th Conference of Parties (COP26) in Glasgow, as countries pledged to stop new coal builds, end international coal financing, phase down and phase out unabated coal use, and transition to clean energy. In South Asia, there have been several indicators suggesting that countries may be open to moving toward a coal transition. For example, the number of coal power plants under development across South Asia has decreased by 87% since 2015 (Littlecott et al., 2021). However, the challenges of assuring a just transition are substantial. Because coal plays a critical role in the energy and economic systems in South Asia, especially India, moving away from coal means realizing a broader country-wide economic and social transition. A comprehensive, integrated transition strategy for each state is thus needed urgently. This report briefly reviews the current trends and policies on coal in South Asian countries, develops a framework for a comprehensive economic coal transition, and assesses the opportunities and challenges of the transition in key countries. Several important findings emerge from the analysis. First, a coal transition can support overall economic growth and stability. Financial advantages to a well-planned coal transition include mitigating the risk of stranded assets and taking advantage of low-cost renewables. As a global coal transition proceeds, funds are being diverted from new unabated coal power plants, and utilization rates are declining. The likelihood that coal assets will become stranded is increasing, and the potential for future losses therefore increases as well. Second, coal imports in South Asia are rising. Of the coal consumed in Bangladesh, India, Nepal, and Sri Lanka, 32% is imported; this number increases to 94% when excluding India (International Energy Agency [IEA], 2021d). This illustrates a serious energy security risk. One example is the recent increase in coal prices in South Asia, to be discussed in Section 2.2.1. A diverse energy portfolio that incorporates local renewable energy can provide resilience in the face of changing commodity prices and availability. Third, the social benefits of a coal transition include positive health impacts and broader economic improvements in job creation, although assuring a just transition may be a challenge. Phasing out or phasing down coal can significantly reduce air pollutant emissions and therefore minimize associated premature mortality and improve life expectancy. Additional societal benefits of a coal transition include the high economy-wide potential for job creation, although it creates challenges in terms of reintegration and resettlement for coal miners and their communities.

01 COAL, LIGNITE, AND PEAT↗

Comprehensive Technology Readiness Assessment Report for LL20-ML-AIT-NE-1-PD3TB

This document ensures that technologies relevant to LL20-ML-AIT-NE-1-PD3TB “AIT-NEO” have been demonstrated to work as intended and at the appropriate technology readiness level. This assessment is intended to offer management tools for understanding and mitigating programmatic risks associated with new technologies being developed under the AIT-NEO effort.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Enabling Cybersecurity, Situational Awareness and Resilience in Distribution Grids with High Penetration of Photovoltaics (CARE-PV) (Final Report)

Since legacy distribution systems have very limited visibility beyond the substation, high penetration of PV at the grid edge presents some unique operational challenges. One approach to address these challenges is to use information from advanced metering infrastructure (AMI) and µPMUs. However, exploiting this information is impacted by a number of factors, including multi-timescale measurements, volume of data generated, communication network impairments (e.g., information loss and latency) and susceptibility to cyber-attacks. Therefore, one of the critical tasks involved in the management of a distribution grid is to develop complete situational awareness by integrating cyber-security mechanisms with state estimation strategies and leveraging this situational awareness to assure energy services at strategic locations while exploiting AMI/PV inverter/ µPMU data. This CARE-PV project addresses the fundamental challenges in situational awareness and resilience to cyber and physical vectors by exploiting the synergy between innovative modeling, estimation, data analytics, testing and validation using smart PV inverters designed at K-State and facilities at NREL. Specifically, the project involved the development, testing and validation of the following novel enabling technologies: (Thrust 1) Resilience to cyber vectors that impact data integrity was addressed via a two-level defense strategy that combines cyber intrusion detection using self-learning, cooperative smart PV inverters, and a novel moving target defense framework to combat data integrity attacks. (Thrust 2) Resilience to cyber-physical vectors that impact situational awareness by limiting data availability was addressed via novel centralized and decentralized, sparsity-based static and dynamic state estimation approaches that enhance observability even when the underlying system is unobservable. (Thrust 3) Leveraging a unique probabilistic sensitivity analysis approach accompanied by one-of-a-kind dominant influencer set computation, the vulnerability of critical infrastructure at strategic locations was evaluated so that proactive PV-based control strategies can be used to support operations under normal/outage scenarios. These CARE-PV project innovations were demonstrated on both small-scale IEEE and larger utility-scale testbeds (Thrust 4). Feedback from Industry Advisory Board members was used to formulate a commercialization pathway for a subset of CARE-PV technologies. These CARE-PV technologies will ultimately lead to reliable and secure, large-scale integration of renewable energy and mitigate the risk of energy disruption resulting from cyber incidents and other emerging threats within the energy environment.

14 SOLAR ENERGY↗

An Innovative Design of High-Temperature, Sensible Molten Salt Thermal Energy Storage Systems With Geopolymer Insulation

This project aims to mitigate the risks of the current molten salt TES tank designs. The goal is to create a more reliable and cost-effective TES by (1) developing a new material solution for internal thermal insulation and (2) by designing a concrete-based tank structure to eliminate metal-related issues (e.g., corrosion, thermomechanical failure, etc.). Firstly, the project aims to engineer a composite refractory insulation material that possesses sufficient thermal insulation properties without significantly sacrificing the resistance to salt permeation and mechanical strength, which is the major trade-off in traditional refractory insulation design. The primary objective is to perform materials design and optimization of the composite refractory to achieve the required thermal and mechanical properties as suitable internal insulation for molten salt TES. Secondly, the project aims to design a concrete-based TES system with conventional low- cost Portland cement serving as the primary tank structure and the aforementioned composite refractory as the internal thermal insulation and salt containment. The objective is to investigate the technical and economical feasibilities of concrete tanks for high- temperature molten salt storage applications.

14 SOLAR ENERGY↗

Dual-Purpose Canister Filling Demonstration Project Progress Report at ORNL, 2023

The US DOE Office of Nuclear Energy is investigating the feasibility of direct disposal of dual-purpose canisters (DPCs) in a hypothetical geological repository to offset the potential requirement to repackage spent nuclear fuel (SNF) from existing DPCs into smaller, disposal-ready canisters. Oak Ridge National Laboratory (ORNL) is currently evaluating the feasibility of filling void space in loaded DPCs with an engineered material to prevent a criticality event caused by groundwater/moderator intrusion. Metal alloys are being investigated as a filler material because of their relatively low viscosities when molten, which may facilitate their injection via an existing drainpipe that runs almost the full length of the DPC. ORNL’s strategy for evaluating filler viability includes simulations and physical demonstrations of filling and casting behavior, as well as evaluations of materials for compatibility in the repository environment. Filling of DPCs in this manner is expected to mitigate the risk associated with a post-closure criticality event during the repository performance assessment time frame (10,000 years or greater). Efforts in this fiscal year focused on (1) destructive analysis of experimental filler castings made in FY 2022, (2) a report outlining a conceptual design of a DPC filling facility (Fortner et al., 2023, M3SF 23OR010305044/ ORNL/SPR-2023/2921, May 31, 2023), (3) a report on affected features, events, and processes (FEPs) due to DPC filling (Price et al., 2023, M3SF-23SN010305093, issuance pending), (4) developing and testing a more practical alloy filler based upon a Sn-Al eutectic, and (5) modeling the heating and cooling dynamics of a DPC subjected to molten metal filling. The preliminary results from each of these tasks support the feasibility of filling DPCs with metal as a strategy against the possibility of criticality in the repository. The FY 2022 casting was found to penetrate even very small orifices in the mold and internal structures. Preliminary testing of the Sn-Al eutectic indicate little interaction of the melt with Zircaloy cladding. Thermal modelling shows that a filled DPC will cool to manageable temperatures within 2-3 days, which is likely manageable in a facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation (Rev.1)

The Hanford Tank Waste Treatment and Immobilization Plant Low Activity Waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of discovering that sampling locations do not meet the qualification criteria on the full-scale stacks. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. For this analysis, the range of qualified flow rates listed is conservatively based on the average DV through 6 DV for LV-S1, LV-S2, and LV-C2, and 1/3 DV to 3 DV for LV-S3. Table S1 lists the operating flow rates along with the conservative lower and upper qualified stack flow rates for each of the LAW facility stacks. For each stack, the operating flow is below the upper qualified stack.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solar Power + Electric Vehicle Charging: Capturing Synergies in Minnesota

Despite the state policy support, significant market barriers to decarbonization of transportation remain. Analysis conducted by the National Renewable Energy Laboratory (NREL) and others confirm that without routine access to charging infrastructure, both at home and in non-residential locations, bullish market forecasts are unlikely to materialize. Similarly, the expansion of EV charging and variable renewable energy deployment each have potentially disruptive and costly effects on the distribution grid. Finally, electrification of passenger vehicles is not enough to decarbonize transportation without pathways to carbon-free electrification, linking EV charging and clean energy generation. This document examines the opportunity to jointly deploy solar energy and EV charging infrastructure to capture synergistic value, mitigate for risks associated with integrating and scaling both solar and EV charging, and accelerate their mutual deployment.

14 SOLAR ENERGY↗

Project No. 5: Evaluating Dredged Materials for Energy Storage Applications with Economic and Carbon Benefits (CRADA Final Report)

The New York Power Authority (NYPA) is committed to supporting the Climate Leadership and Community Protection Act (CLCPA) through its VISION2030 strategic plan. As a clean energy provider, NYPA is seeking to demonstrate leadership in every aspect of its business by taking a comprehensive approach to sustainability management and integrating sustainability principles into day-to-day decision-making. This effort includes planning for climate resilience through projects that mitigate climate risk in our operations and prioritize climate opportunities in our investments. Canal Corporation, a subsidiary of NYPA, is charged with maintaining minimum water depths for navigation in the Cayuga-Seneca, Champlain, Erie and Oswego Canals. In order to do so, an average volume of 280,000 cubic yards of sediment is dredged annually and held in Upland Disposal Sites (UDS) permitted by the New York Department of Environmental Conservation (NYSDEC). The required on-land storage at UDSes are nearing capacity, and disposal opportunities are costly, both economically and environmentally. Novel energy storage technology developed by NREL provides an opportunity for meeting NYPA's need to find reuse options for dredged materials and commitment to providing clean reliable energy. This would also support NYPA's goal of developing 300 MW of utility scale storage and enabling 150 MW of distributed storage by 2030. NREL will consult NYPA on the environmental and economic impact of reusing dredged materials as useful commodities such as energy storage media, construction sand or industrial uses. Test and material characterization methods will be based on current NREL storage material characterization approaches. NREL worked with NYPA on sample preparation, material testing, test results analysis. Test and material characterization methods were based on current NREL storage material characterization approaches. The team analyzed the environmental and economic impact of reusing dredged materials as useful commodities such as energy storage media, construction sand or industrial uses. The test and analysis works have achieved the project goal in characterizing NYPA dredging materials and verifying their various uses including construction sand and thermal energy storage media. Uses of dredging materials as useful materials will bring economic and environmental benefits and avoid disposal costs.

25 ENERGY STORAGE↗

Low Temperature CO2 Capture from an NGCC Flue Gas Using a Magnetically Stabilized, Inductively Heated Fluidized Bed Reactor

The lab sorbent testing finalized the sorbent composition and operating conditions for the integrated unit. The bench unit design included COMSOL simulation to finalize the coil design and select initial operating conditions of the power supply system. Fluidized bed testing with the induction heating verified that a heating efficiency of up to 90% can be achieved. The integrated bench unit operations provided valuable data confirming the feasibility of using induction heating for the desorption of CO2. Major challenge observed was the limited working capacity of the sorbent, requiring additional development in future projects. In addition, a large-scale reactor demonstration is required to mitigate the risk of uniform temperature distribution and heating efficiency over a large cross-sectional area when using induction heating.

Tong, Andrew↗

National Energy Water Treatment and Speciation (NEWTS) Database & Dashboard

The Department of Energy's Office of Fossil Energy & Carbon Management (DOE/FECM) through the National Energy Technology Laboratory (NETL) has launched a free online tool, the National Energy Water Treatment and Speciation (NEWTS) Database and Dashboard, which can be utilized by community leaders and water researchers to better understand the composition of energy-related wastewater streams. The NEWTS Database and Dashboard provide public access to difficult-to-access datasets, including the original data sources and the processed data forms for input into aqueous chemistry modeling software. The data provided by the tool will help mitigate environmental risks and identify possible sources of valuable critical minerals (CM). The goal of this ASME Power presentation is to highlight the data and capabilities of this free online-tool for obtaining high quality water datasets in formats that are easy for modeling the treatment and recovery of valuable resources from effluent waste stream associated with energy operations.

Siefert, Nicholas↗

Overview and Commentary on Applying the Coordinated Vulnerability Disclosure Process to Photovoltaic System Devices

The rapid expansion of photovoltaic (PV) systems, particularly inverters, has introduced new cybersecurity challenges that threaten both local operations as well as the broader electrical grid’s stability. PV inverters, integrated into critical energy infrastructure are potential targets for cyber attacks due to vulnerabilities in firmware, remote access systems, and communication protocols. The Coordinated Vulnerability Disclosure (CVD) process, as defined by the Cybersecurity and Infrastructure Security Agency (CISA), provides a framework for identifying, reporting, and addressing these vulnerabilities in a transparent and collaborative manner. This report outlines the CVD process as it applies to PV systems, detailing the roles of key stakeholders, such as manufacturers, grid operators, and security researchers. The report also highlights specific challenges in managing vulnerabilities for new and legacy PV systems, which includes those introduced by insecure communications and third-party supply chain components. By adhering to the CVD process, the PV industry can mitigate cybersecurity risks, ensure regulatory compliance, and maintain consumer trust, while safeguarding the operational resilience of the energy grid. Ultimately, the effective coordination of vulnerability management is crucial for securing the future of PV systems within the critical electric grid infrastructure landscape.

14 SOLAR ENERGY↗

Simple and Scalable Process for Nanocellulose Production from Residues and Waste (CRADA Final Report)

This project successfully developed an innovative, cost-effective, and scalable method for converting low-cost agricultural waste feedstocks into nanocellulose—a sustainable material with wide-ranging industrial applications. It addressed the critical challenges of high production costs and limited global supply, which have hindered the widespread adoption of nanocellulose in industry. Through this work, significant advancements were made in optimizing resource use, improving process efficiency, and reducing costs. Notable achievements included a 50% reduction in water usage, 30% lower chemical consumption, and 20% energy savings, all while maintaining high-quality product standards. The technical feasibility of the process was further validated at a 10L scale in collaboration with the Advanced Biofuels and Bioproducts Development Unit (ABPDU), demonstrating scalability and replicability. Key challenges in reducing nanocellulose production costs were addressed by utilizing low-cost biomass feedstocks and implementing low-temperature conversion reactions, leading to lower capital and operating expenses. The project also mitigated financial risk by generating critical data on the feasibility, adaptability, and scalability of the conversion technology, paving the way for its commercial implementation. Public benefits include advancing the circular bioeconomy, reducing environmental impact, fostering job creation, and enabling a shift toward biobased materials as sustainable alternatives to fossil-based products. These outcomes align closely with national goals to reduce greenhouse gas emissions and promote sustainable technological innovation.

09 BIOMASS FUELS↗

Testing- and Model- Based Optimization of Coal-fired Primary Heater Design for Indirect Supercritical CO 2 Power Cycles (Final Scientific and Technical Report)

The overall objective of this project was to perform the R&D necessary to mitigate the risk associated with the design of a primary heat exchanger for a solid-fired combustion system coupled with an indirect-fired closed-loop Brayton Cycle utilizing supercritical CO 2 . The key technological hurdle was the coupling of a solid-fuel firing system with the primary heater, which poses a singular challenge, which is the management of burner performance and operational conditions in a way to manage heat exchanger tube metal temperatures and temperature ramp rates in the absence of fluid phase change on the inside of the tubes. We designed and built the first ever pseudo power system employing a simple recuperated supercritical CO 2 closed-loop Brayton Cycle coupled to a solid-fuel fired system. Advanced coupled CFD and process modeling were used to design the primary heat exchanger (PHX), which consisted of both radiative and convective sections, to limit tube metal temperatures resulting from the heat release profile of the solid fuel flame near the radiative tubes. The heat exchanger was designed to produce finished CO 2 temperatures of 600 °C a pressure of 20.7 MPa and CO 2 flow of 5.5 kg/s. The constructed PHX was capable of 1.2 MWth heat uptake. During design of the PHX, the modeling showed that most variables influencing flame shape (burner stoichiometric ratio and register velocities and swirl) were not suitable to manage heat flux to the metal surfaces. This is because they substantially increased adiabatic flame temperature through the influence of localized stoichiometric ratio. Excess air and firing rate were the two most powerful variables that could be used to control tube surface temperatures. The coupled system was operated for a total of 407 hours, with the longest continuous run of 248 hours. For 62% of the operational time, the unit was unmanned and in automatic control. The fuels used for the testing included natural gas, two Utah Bituminous coals, woody biomass, and bagasse. During the testing we were able to verify the 1.2 MWth heat uptake and we operated at a finished CO 2 temperature of 607 °C and a pressure of 20.3 MPa simultaneously. The real-time corrosion rate of the Super 304H tube CO 2 surface in the region of the radiative section of the PHX were measured, at an approximate temperature of 550 °C. The two key variables related to corrosion rate are the pressure and flow rate of the CO 2 . A technoeconomic analysis was performed at a scale of 120 MWE. The updated analysis showed that the efficiency of an sCO 2 power producing plant will be related to the pressure drop of the PHX.

01 COAL, LIGNITE, AND PEAT↗

MRCI Subtask 2.2: Precambrian Basement Structure, Faulting, and Stress Final Technical Summary Report

Subtask 2.2 was largely focused on compiling information about the Precambrian basement rock that underlies the MRCI region. Understanding the nature and extent of the basement rock is important in order to mitigate certain risks associated with CO2 injection. For example, this information will provide a resource for defining areas where a storage reservoir is in direct contact with the Precambrian or indirectly via a fault. Also, an understanding of the stress field in addition to fault orientations will help determine which faults may be subject to reactivation under increased pore pressures.

Battelle,CCS,CCUS,Carbon storage,MRCI,Midwest Regi↗

Basin & Range Investigation for Developing Geothermal Energy

Hidden geothermal systems represent a potentially prolific energy resource that could support critical U.S. public and government energy priorities. Basin and Range Investigations for Developing Geothermal Energy (BRIDGE) addressed some the challenges associated with hidden system exploration by prioritizing cost-effective exploration early on through strategic workflow and informed decision-making that mitigates early risk and shifts resources to later exploration stages (e.g., drilling). Sandia National Laboratories partnered with U.S. Navy Geothermal Office, Geologic Geothermal Group, and independent consultants, with additional collaboration with U.S. Geological Survey and private industry. The primary tool of the BRIDGE project was to deploy a regional-scale airborne electromagnetic method to investigate the shallow resistivity structure in areas with high prospectivity. This was followed up at several prospects by a multidisciplinary exploration approach, including additional geologic, geophysical and geochemical studies. A central tenet to the BRIDGE methodology is that zones of low resistivity frequently occur over geothermal systems in the Basin and Range, and when paired with other data constraints, imaging these zones can enable discovery of these systems. In addition to exploring greenfield areas (i.e., Grover Point), the BRIDGE project also flew HTEM resistivity surveys over known geothermal systems including those with established power plants (Don A. Campbell and Salt Wells) and prospects that are known to the literature but remain undeveloped, at least in part, due to a lack of understanding on the location of their producible reservoirs. BRIDGE produced a comprehensive set of data from prospects identified in the Nevada Play Fairway Analysis along with conceptual models for top ranking prospects, wherein all of the observations are used to inform an interpreted model of the system. These models present a range of possible system parameters such as temperature and size, and they are further informed by system analogues in the Basin and Range province and elsewhere. The results of this work leave space for further exploration that may now occur at prospects ‘down the list’ rather than distribution exploration resources evenly across all prospects.

15 GEOTHERMAL ENERGY↗