Hidden geothermal systems represent a potentially prolific energy resource that could support critical U.S. public and government energy priorities. Basin and Range Investigations for Developing Geothermal Energy (BRIDGE) addressed some the challenges associated with hidden system exploration by prioritizing cost-effective exploration early on through strategic workflow and informed decision-making that mitigates early risk and shifts resources to later exploration stages (e.g., drilling). Sandia National Laboratories partnered with U.S. Navy Geothermal Office, Geologic Geothermal Group, and independent consultants, with additional collaboration with U.S. Geological Survey and private industry. The primary tool of the BRIDGE project was to deploy a regional-scale airborne electromagnetic method to investigate the shallow resistivity structure in areas with high prospectivity. This was followed up at several prospects by a multidisciplinary exploration approach, including additional geologic, geophysical and geochemical studies. A central tenet to the BRIDGE methodology is that zones of low resistivity frequently occur over geothermal systems in the Basin and Range, and when paired with other data constraints, imaging these zones can enable discovery of these systems. In addition to exploring greenfield areas (i.e., Grover Point), the BRIDGE project also flew HTEM resistivity surveys over known geothermal systems including those with established power plants (Don A. Campbell and Salt Wells) and prospects that are known to the literature but remain undeveloped, at least in part, due to a lack of understanding on the location of their producible reservoirs. BRIDGE produced a comprehensive set of data from prospects identified in the Nevada Play Fairway Analysis along with conceptual models for top ranking prospects, wherein all of the observations are used to inform an interpreted model of the system. These models present a range of possible system parameters such as temperature and size, and they are further informed by system analogues in the Basin and Range province and elsewhere. The results of this work leave space for further exploration that may now occur at prospects ‘down the list’ rather than distribution exploration resources evenly across all prospects.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Downs, Christine [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)], Schwering, Paul C. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)], Kraal, Kurt Otto [Geologica Geothermal Group, Reno, NV (United States)], Folsom, Matthew [Geologica Geothermal Group, Reno, NV (United States)], Winn, Carmen [Geologica Geothermal Group, Reno, NV (United States)] (ORCID:0000000232663963), Hinz, Nicholas [Geologica Geothermal Group, Reno, NV (United States)], Milton, Alex [Geologica Geothermal Group, Reno, NV (United States)], Zimmerman, Jade [Naval Facilities Engineering Command Southwest, Joint Base Pearl Harbor-Hickam, HI (United States)] (ORCID:0000000345492742), Sabin, Andrew [Naval Facilities Engineering Command Southwest, Joint Base Pearl Harbor-Hickam, HI (United States)], Sewell, Steven [Austrailis Geoscience Ltd.], Cumming, William [Cumming Geoscience], Lopeman, Janice [Geologica Geothermal Group, Reno, NV (United States)]. 2025-02-01. Basin & Range Investigation for Developing Geothermal Energy. https://doi.org/10.2172/2540220

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Technical, economic, and load-following capabilities assessment of grid-connected geothermal and geothermal-solar hybrid systems

The technical and economic performance as well as the load-following capabilities of grid-connected geothermal hybrid systems were assessed in this work. The analyzed geothermal hybrid configuration is composed of a binary geothermal plant integrated with a concentrating solar-thermal system and underground thermal energy storage (UTES) through a primary heat exchanger. Physics-based models for the hybrid system for plant generation capacities of 1, 25, and 50 MW were developed from validated models for each subsystem. Also, an economic model was developed that accounts for different hybrid system capabilities, solar field sizes, and thermal storage duration. The advantage of the geothermal hybrid system was assessed by comparing the performance with the baseline benchmark geothermal plant with a similar configuration and generation capacity. It was found that hybridizing geothermal plants with concentrating solar and thermal energy storage not only improves the thermal efficiency by up to 8 percentage points when additional heat from the solar-UTES loop rises the evaporator temperatures from 70 to 125 °C, but also enhances the load-following capability for the geothermal plant, which can meet a typical residential load profile with a power rate of change 0.25 kW/s with an absolute error under 13 kW for a 1 MW plant. Other benefits of hybridization include resource preservation and a potential LCOE reduction of up to 56% for a 50 MW geothermal hybrid plant having a 50% solar share, a 1.4 solar multiple, and 24-h storage capacity. The results presented in this work demonstrate that hybridizing geothermal systems transforms them into a flexible and cost-effective solution for addressing the dynamic requirements of modern electric grids.

15 GEOTHERMAL ENERGY

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY

Impact of Space Heating Options on Electricity Rates and Affordability

Electricity prices have increased in many regions of the U.S., with a national average of 18 cents/kWh projected for 2026, up from 16 cents/kWh in 2020. While the increases can be attributed to a number of factors, increasing electricity use in an efficient and strategic manner - with energy efficient building envelope upgrades and high performance HVAC systems - has the potential to increase revenue for utilities without significantly increasing electricity demand, and therefore could help moderate rate increases. This effect has been studied for electric vehicle charging[1] and dual-fuel heat pumps in Minnesota[2]. Leveraging a recently developed system cost methodology and FERC data on utility revenue, spending, and profits, this poster will present the direction and relative magnitude of rate impacts for efficient space heating upgrades in utility balancing areas across the contiguous U.S., using current prices and showing how the rate impacts would evolve under future grid scenarios.

15 GEOTHERMAL ENERGY