Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “visibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Surface Biology and Geology (SBG) Visible to Short Wavelength Infrared (VSWIR) Wide Swath Instrument Concept

The 2017 Decadal Survey: Thriving on Our Changing Planet, A Decadal Strategy for Earth Observation from Space has called new observations including global coverage Visible to Short Wavelength Infrared (VSWIR) Wide Swath (WS) imaging spectroscopy measurements as part of the Surface Biology and Geology (SBG) Designated Observable. The SBG VSWIR-WS along with the companion SBG Thermal Infrared (TIR) imager is an important element of NASA’s larger Earth System Observatory (ESO).

Walch, Marc↗

Assessment of Dust Size Retrievals Based on AERONET: A Case Study of Radiative Closure From Visible-Near-Infrared to Thermal Infrared

Super-coarse dust particles (diameters >10 μm) are evidenced to be more abundant in the atmosphere than model estimates and contribute significantly to the dust climate impacts. Since super-coarse dust accounts for less dust extinction in the visible-to-near-infrared (VIS-NIR) than in the thermal infrared (TIR) spectral regime, they are suspected to be underestimated by remote sensing instruments operates only in VIS-NIR, including Aerosol Robotic Networks (AERONET), a widely used data set for dust model validation. In this study, we perform a radiative closure assessment using the AERONET-retrieved size distribution in comparison with the collocated Atmospheric Infrared Sounder (AIRS) TIR observations with comprehensive uncertainty analysis. The consistently warm bias in the comparisons suggests a potential underestimation of super-coarse dust in the AERONET retrievals due to the limited VIS-NIR sensitivity. An extra super-coarse mode included in the AERONET-retrieved size distribution helps improve the TIR closure without deteriorating the retrieval accuracy in the VIS-NIR.

thermal infrared (TIR)↗

Three-Dimensional Atmospheric Dynamics of Jupiter from Ground-Based Doppler Imaging Spectroscopy in the Visible

We present three-dimensional (3D) maps of Jupiter’s atmospheric circulation at cloud-top level from Doppler-imaging data obtained in the visible domain with JIVE, the second node of the JOVIAL network, which is mounted on the Dunn Solar Telescope at Sunspot, New Mexico. We report on 12 nights of observations between May 4 and May 30, 2018, representing a total of about 80 hours. Firstly, the average zonal wind profile derived from our data is compatible with that derived from cloud-tracking measurements performed on Hubble Space Telescope images obtained in April 2018 from the Outer Planet Atmospheres Legacy (OPAL) program. Secondly, we present the first ever two-dimensional maps of Jupiter’s atmospheric circulation from Doppler measurements. The zonal velocity map highlights well-known atmospheric features, such as the equatorial hot spots and the Great Red Spot (GRS). In addition to zonal winds, we derive meridional and vertical velocity fields from the Doppler data. The motions attributed to vertical flows are mainly located at the boundary between the equatorial belts and tropical zones, which could indicate active motion in these regions. Qualitatively, these results compare well to recent Juno data that have unveiled the three-dimensional structure of Jupiter’s wind field. To the contrary, the motions attributed to meridional circulation are very different from what is obtained by cloud tracking, except at the GRS. Because of limitations with data resolution and processing techniques, we acknowledge that our measurement of vertical or meridional flows of Jupiter are still to be confirmed.

Francois-Xavier Schmider↗

The CapiSorb Visible System (CVS) Demonstrations on ISS

Falling liquid film amine sorbent reactors have been successfully employed to scrub CO 2 aboard submarines for decades. However, applying such proven methods aboard orbiting and coast spacecraft is significantly challenged by the nearly weightless environment, where liquid sprays and films do not fall, and vapor bubbles and gases do not rise. The Capillary Sorbent (CapiSorb) Visible System (CVS) is a technology demonstration experiment performed aboard the ISS April 18 – 21, 2023. The system establishes stable steady thin liquid film flows in Contactor (absorber) and Degasser (desorber/stripper) replacing the passive role of gravity with the combined passive roles of surface tension, wetting, and system geometry. A TOX-0 fructose ersatz liquid sorbent is employed enabling ‘transparent’ experiments performed and filmed by the crew safely in the open cabin of the ISS. Completed objectives include demonstrations of stable passive ‘massively’ parallel planar thin film capillary flows across atmospheric pressure Contactor and sealed heated Degasser. The impacts of varying flow rate, flow direction, heat input, viscosity, positive and negative Degasser pressures, condensate collection and return, fluid distribution, interfacial stability, and others are reported. At least 49 diagnostics are recorded for digitization and subsequent thermal-fluids model validation by a single HD video downlink during the nearly 22 hours of operations. An overview of the flight hardware including description of the components, diagnostics, crew procedures, flight operations, and summary of accomplishments is reported in Ref. 1. Further details of the diagnostics, tests performed, and data reduction is reported in Ref. 2. This report collects both1,2 into a single report adding methods of data digitization, reduction, and archive along with analyses and discussions of technology impacts.

microgravity↗

Effect of Barely Visible Impact Damage on Thermoplastic Welded Structure

Spirit Aerosystems recently conducted screening tests on thermoplastic skin/stringer panels manufactured with Automated Fiber Placement (AFP) and stamp forming which were joined using Spirit’s Co-Fusion process. Skin and stringer gauge were both set to 0.168 cm. The resulting panel design is 48 cm tall, 49 cm wide, and has 3 stringers welded at a 21.5 cm pitch. Barely Visible Impact Damage (BVID) and Residual Compressive Strength were chosen to conduct a damage tolerance study. Zee stringers, made with IM8/PEKK-FC material, were Co-Fusion welded to a T1100/TC1225 skin. Out of these 5 panels, 1 was chosen to be a BVID survey panel, 1 for pristine compressive strength determination, and 3 to be impacted to create BVID followed by testing for residual compressive strength. On the survey panel, impacts ranged in energy from 40J – 65J and dent depth measurements were conducted at 24 hours, 48 hours, and two weeks after impacting. The residual compressive strength panel failed near the predicted load of 214 MPa. For the residual compressive strength panels, BVID was created at two different mid-bay locations: 1) striking the OML coincident with the stringer and 2) striking the skin IML 2.5 cm away from the stringer flange. Pulse Echo Ultrasonic Testing was used to inspect the panels before and after creating BVID.

HiCAM↗

Enhancement of the visibility of objects located below the surface of a scattering medium

Techniques are provided for enhancing the visibility of objects located below the surface of a scattering medium such as tissue, water and smoke. Examples of such an object include a vein located below the skin, a mine located below the surface of the sea and a human in a location covered by smoke. The enhancement of the image contrast of a subsurface structure is based on the utilization of structured illumination. In the specific application of this invention to image the veins in the arm or other part of the body, the issue of how to control the intensity of the image of a metal object (such as a needle) that must be inserted into the vein is also addressed.

47 OTHER INSTRUMENTATION↗

Volume-scalable high-brightness three-dimensional visible light source

A volume-scalable, high-brightness, electrically driven visible light source comprises a three-dimensional photonic crystal (3DPC) comprising one or more direct bandgap semiconductors. The improved light emission performance of the invention is achieved based on the enhancement of radiative emission of light emitters placed inside a 3DPC due to the strong modification of the photonic density-of-states engendered by the 3DPC.

42 ENGINEERING↗

Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air

Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. However, the reflectance of PTFE is a function of its thickness. In this work, we investigate this dependence in air for light of wavelengths 260 nm and 450 nm using two complementary methods. We find that PTFE reflectance for thicknesses from 5 mm to 10 mm ranges from 92.5% to 94.5% at 450 nm, and from 90.0% to 92.0% at 260 nm. We also see that the reflectance of PTFE of a given thickness can vary by as much as 2.7% within the same piece of material. Finally, we show that placing a specular reflector behind the PTFE can recover the loss of reflectance in the visible without introducing a specular component in the reflectance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrathin, polarization-independent, achromatic metalens for focusing visible light

An optical device includes a titanium dioxide substrate layer on a quartz base of a substrate. The substrate is configured to focus light in visible wavelength spectrum of 400 nm to 700 nm. The substrate comprises a first zone and a second zone. In some embodiments, the first zone and the second zone are concentric circles. A plurality of resonators are disposed on the substrate, the plurality of resonators comprising a first plurality corresponding to the first zone and a second plurality corresponding to the second zone. Each resonator is comprised of a dielectric material with a defined thickness “t” in the range of 30 nm to 300 nm. Each resonator has a radius “r” in the range of 30 nm to 300 nm and a gap “g” between adjacent resonators in the range of 5 nm to 200 nm. The first plurality of resonators in the first zone have a first radius within a first radius range that is different from a second radius range of the second plurality of resonators in the second zone. The plurality of resonators form a metasurface that defines at least in part an ultra-thin achromatic lens of the optical device.

47 OTHER INSTRUMENTATION↗

Combining visible shadowgraph imaging with x-ray imaging for dynamic shock experiments

Interrogating ejecta particles launched from target materials that are undergoing dynamic shock can be done with both x-ray imaging and visible shadowgraph imaging. Our dynamic testing must be done inside a containment vessel with limited access ports available. We designed an imaging system to relay both types of imaging systems through a single port using the same optical relay and then splitting the images onto three separate high-speed imaging cameras outside the containment vessel. X-ray imaging provides ejecta density measurements. Shadowgraph imaging that is done at two wavelengths (blue and red) constrains ejecta particle size distributions and provides areal density measurements of the ejecta cloud. The ejecta particles are positioned 225 mm before the x-ray scintillators; this arrangement permits a folded mirror system to allow the shadowgraph data to bypass the x-ray scintillators. This configuration results in spatial separations between the intermediate image planes of the x-ray and shadowgraph images along the optical axis. At the position of the x-ray intermediate image plane, mirrors are positioned such that the shadowgraph images are kicked out and their images are sent on to different cameras. Positioning of the large doublet relay lenses keeps shrapnel from impacting the vessel containment windows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tag that enhances vehicle radar visibility of objects

A tag enhances vehicle radar visibility of objects by increasing the effective radar cross-section of the object, allowing detection at longer ranges and providing the vehicle/driver with more time to avoid a collision. The tag may include a receive antenna and a bandpass filter configured to receive a signal from the receive antenna and to allow a portion of the frequency range of the signal from the receive antenna through. The tag may also include an amplifier configured to receive and amplify the signal with the portion of the frequency range from the bandpass filter. The tag may further include a transmit antenna configured to transmit the amplified signal. The receive antenna, the transmit antenna, and the amplifier may be configured such that antenna-to-antenna isolation between the receive antenna and the transmit antenna is greater than a gain of the amplifier.

42 ENGINEERING↗

Zapiary: Creating Visibility in IOT Networks

Zigbee and Z-Wave are the main networking protocols used by low-power Internet of Things (IOT) devices. These protocols use low frequencies. Mesh architecture, and unique address formats that make them not compatible with traditional network traffic tools like IX-Discovery Tools. Zapiary is a software that takes CSV files with Zigbee and Z-Wave traffic and generates Structured Threat Information eXpression (STIX) JSON bundles illustrating the communication within IOT networks. The bundles can then be viewed within Structured Threat Intelligence Graph (STIG) or used with AI/ML models to provide deeper visibility into nodes that make up the network and the ability to trend the mesh network over time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-throughput Accurate-wavelength Lens-based Visible Spectrometera

A scanning visible spectrometer has been prototyped to complement fixed-wavelength transmission grating spectrometers for charge exchange recombination spectroscopy. Fast f/1.8 200 mm commercial lenses are used with a large 2160 mm-1 grating for high throughput. A stepping-motor controlled sine drive positions the grating, which is mounted on a precision rotary table. A high-resolution optical encoder on the grating stage allows the grating angle to be measured with an absolute accuracy of 0.075 arcsec, corresponding to a wavelength error ≤ 0.005 Å. At this precision, changes in grating groove density due to thermal expansion and variations in the refractive index of air are important. An automated calibration procedure determines all relevant spectrometer parameters to high accuracy. Changes in bulk grating temperature, atmospheric temperature and pressure are monitored between the time of calibration and the time of measurement to insure a persistent wavelength calibration

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emission of Visible Light by Hot Dense Metals

We consider the emission of visible light by hot metal surfaces having uniform and non-uniform temperature distributions and by small droplets of liquid metal. The calculations employ a nonlocal transport theory for light emission, using the Kubo formula to relate microscopic current fluctuations to the dielectric function of the material. We describe a related algorithm for calculating radiation emission in particle simulation of hot fusion plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Accuracy Wavelength Calibration For A Scanning Visible Spectrometer

Spectroscopic applications for plasma velocity measurements often require wavelength accuracies ≤ 0.2Â. An automated calibration for a scanning spectrometer has been developed to achieve a high wavelength accuracy overr the visible spectrum, stable over time and environmental conditions, without the need to recalibrate after each grating movement. The method fits all relevant spectrometer paraameters using multiple calibration spectra. With a steping-motor controlled sine-drive, accuracies of ~0.025 Â have been demonstrated. With the addition of high resolution (0.075 aresec) optical encoder on the grading stage, greater precision (~0.005 Â) is possible, allowing absolute velocity measurements with ~0.3 km/s. This level of precision requires monitoring of atmospheric temperature and pressure and of grating bulk temperature to correct for changes in the refractive index of air and the groove density, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Examining the temporal evolution of hypervelocity impact phenomena via high-speed imaging and ultraviolet-visible emission spectroscopy

The temporal evolution of a previously observed hypervelocity impact-induced vapor cloud [Mihaly et al., Int. J. Impact Eng. 62, 13 (2013)] was measured by simultaneously recording several full-field, near-IR images of the resulting emission using an OMA-V high-speed camera. A two-stage light-gas gun was used to accelerate 5 mg Nylon 6/6 right-cylinders to speeds between 5 km/s and 7 km/s to impact 1.5 mm thick 6061-T6 aluminum target plates. Complementary laser-side-lighting [Mihaly et al., Int. J. Impact Eng. 62, 13 (2013); Proc. Eng. 58, 363 (2013)] and front-of-target (without laser illumination) images were also captured using a Cordin ultra-high-speed camera. The rapid expansion of the vapor cloud was observed to contain a bright, emitting exterior, and a darker, optically thick interior. The shape of this phenomenon was also observed to vary considerably between experiments due to extremely high-rate (>250 000 rpm) of tumbling of the cylindrical projectiles. Additionally, UV-vis emission spectra were simultaneously recorded to investigate the temporal evolution of the atomic and molecular composition of the up-range, impact-induced vapor plume. A PI-MAX3 high-speed camera coupled to an Acton spectrograph was utilized to capture the UV-vis spectra, which shows an overall peak in emission intensity between approximately 6–10 μs after impact trigger, corresponding to an increased quantity of emitting vapor/plasma passing through the spectrometer slit during this time period. The relative intensity of the numerous spectral bands was also observed to vary according to the exposure delay of the camera, indicating that the different atomic/molecular species exhibit a varied temporal evolution during the vapor cloud expansion. Higher resolution spectra yielded additional emission lines/bands that provide further evidence of interaction between fragmented projectile material and the 1 mmHg atmosphere inside the target chamber. A comparison of the data to down-range emission spectra also revealed differences in the relative intensities of the atomic/molecular composition of the observed vapor clouds.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectroscopic Monitoring of Spent Nuclear Fuel Reprocessing Streams: An Evaluation of Spent Fuel Solutions via Raman, Visible, and Near-Infrared Spectroscopy

The potential of using optical spectroscopic techniques, such as Raman and Visible/Near Infrared (Vis/NIR), for on-line process control and special nuclear materials accountability applications at a spent nuclear fuel reprocessing facility was evaluated. Availability of on-line real-time techniques that directly measure process concentrations of nuclear materials will enhance performance and proliferation resistance of the solvent extraction processes. Further, on-line monitoring of radiochemical streams will also improve reprocessing plant operation and safety. This report reviews current state of development of the spectroscopic on-line monitoring techniques for such solutions. To further examine applicability of optical spectroscopy for monitoring reprocessing solutions, segments of a spent nuclear fuel, with approximate burn-up values of 70 MWd/kgM, were dissolved in concentrated nitric acid and adjusted to varying final concentrations of HNO3. The resulting spent fuel solutions were batch-contacted with tributyl phosphate/dodecane organic solvent. The feed and equilibrium aqueous and loaded organic solutions were subjected to optical measurements. The obtained spectra showed the presence of the quantifiable Raman bands due to NO3- and UO22+ and Vis/NIR bands due to multiple species of Pu(IV), Pu(VI), Np(V), the Np(V)-U(VI) cation-cation complex, and Nd(III) in fuel solutions, justifying spectroscopic techniques as a promising methodology for monitoring spent fuel processing solutions in real-time. Quantitative evaluation of the fuel solution was performed based on spectroscopic measurements and compared to ICP-MS analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Photocatalytic degradation of orange II dye via high pore volume polymorph zirconium-doped titania under visible light irradiation

A series of mixed-phase Zr-doped TiO 2 was utilized for the photocatalytic degradation of orange II dye. These materials were synthesized through a sol–gel technique by varying the amounts of zirconium in the photocatalysts. These materials were characterized using X-ray diffraction (XRD), transmission electron microscopy (TEM), X-ray fluorescence (XRF), Raman spectroscopy, thermogravimetry analysis (TGA), and X-ray photoelectron spectroscopy (XPS) among others. XRF and XPS data showed that the elemental composition of the photocatalysts consists of zirconium, titanium, and oxygen. In addition, XRD and Raman spectroscopy confirmed the existence of anatase and rutile phases of TiO 2 . The TGA analyses showed that the undoped TiO 2 was the most stable, with no significant weight loss during the heating range. Furthermore, the materials can effectively degrade orange II dye solution up to 7 cycles through asymmetric cleavage of the azo bond.

36 MATERIALS SCIENCE↗