Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “user study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Computational Modeling of Graphite Degradation due to Molten Salt Infiltration and Wear

Molten-salt reactors (MSRs) represent a promising next-generation reactor design, with graphite serving as a moderator and/or reflector in several designs. However, due to limited experimental data and operational experience, a technical understanding of the structural integrity of graphite in molten salt environments remains incomplete. This report presents a modeling-based evaluation of graphite degradation in MSR environments, focusing on the effects of salt infiltration in fuel salt-based designs and surface wear in pebble bed reactor designs. The objective of this study is to enhance understanding of the structural integrity challenges posed by these degradation mechanisms and to provide a framework for assessing graphite behavior in MSRs. The first part of the report investigates the phenomenon of molten salt infiltration into graphite. This infiltration occurs when molten salt permeates the interconnected pore structure of the graphite moderator, driven by factors such as pressure differentials and the physical properties of both the salt and graphite. The infiltration process is influenced by characteristics of the pore structure, viscosity of the molten salt, and the interfacial energies between the graphite, salt, and the atmosphere within the graphite pore. Utilizing a coupled multiphysics modeling approach with Grizzly software, the study evaluates the stress induced by internal heat sources due to infiltration, which can lead to structural concerns. This evaluation is crucial for understanding how infiltration affects the mechanical integrity of graphite components in MSRs. The study considers the Molten-Salt Reactor Experiment (MSRE) graphite stringer geometry due to the availability of relevant data. Through detailed finite element analysis, the study examines stress distributions at varying infiltration percentages, revealing that stress levels increase with higher amounts of infiltration. Rare-event simulations, using the parallel subset simulation (PSS) framework, further quantify the failure probabilities under input uncertainties, with a user-specified failure metric. The PSS framework also identifies critical input parameters that significantly affect the stress values, including infiltration amount, thermal conductivity, and power density. Additionally, considering realistic reactor scenarios, the analysis was performed to account for the combined effects of radiation and infiltration, and modeling strategies on how to analyze new reactor designs or new graphite grades are discussed. The second part of the report focuses on wear mechanisms in pebble bed-based MSRs. As graphite fuel pebbles interact with the graphite reflector block, wear can result in material loss and the formation of surface defects, which may act as stress concentrators. A similar multiphysics modeling framework is employed to assess the impact of wear on the structural integrity of graphite components. This study considers a generic fluoride-cooled high-temperature reactor (gFHR) design due to the availability of comprehensive data. Worst-case scenario dimensions of the reflector blocks were analyzed under thermal and radiation conditions. Subsequently, wear in the form of idealized pits and grooves is modeled on the inner surface of the graphite block, with the maximum stress from previous simulations. The simulations show that groove-type defects are more detrimental than pits, leading to higher stress concentrations. Considering worst-case simulation scenarios and experimental wear rates, it was determined that the formation of a surface defect critical enough to affect the stress may not be possible in a gFHR design. Overall, the findings of this research contribute to the development of robust modeling tools for predicting graphite behavior under various operational conditions in MSRs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Deciding Between an X-Ray and 137Cs Irradiator – It’s Not Just About Energy Spectra

Irradiators utilizing radioactive cesium-137 or cobalt-60 have been used for medical applications for many decades. This includes the irradiation of much of the nation’s blood supply, and radiation biology research. In 2005, the U.S. Nuclear Regulatory Commission was assigned to evaluate and prevent the misuse of radioactive materials with malicious intentions, with gamma-ray sources being high on the list. Licensees who possessed higher quantities of radioactive material of concern were required to set up increased security controls such as constant surveillance, controlled access, personnel background checks, and other security controls. As a result of introducing such regulations, and problems with disposing of high activity sources, many users of gamma-ray sources started to look into alternative technologies to replace their gamma-ray irradiators – the main alternative being an X-ray irradiator. To make an educated decision on whether a particular type of X-ray irradiator is equivalent to a particular type of cesium-137 irradiator for specific applications, one has to rely on relevant published comparison studies from other researchers, or perform the comparison studies on their own. This publication focuses on the authors’ technical performance comparison of two cesium-137 irradiator models and two X-ray irradiator models, for the purpose of determining whether the X-ray irradiator models could validly replace the cesium-137 irradiator models for certain applications. Utilizing 47 gram and 120 gram tissue-equivalent rodent dosimetry phantoms, our results indicate that, depending upon the user’s dose uncertainty budget and maximum size of specimens to be irradiated, the Model RS2000 160 kVp X-ray irradiator, Model XRAD-160 X-ray irradiator, or Model XRAD-320 X-ray irradiator, could successfully replace a cesium-137 irradiator. It is expected such equivalency could be extrapolated to other irradiated specimens of known sizes and density. Results also reveal that differences in inherent source geometry, field geometry and irradiation geometry can counter some of the influence due to differences in energy spectrum. It is hoped that this publication can be used as a guide for other similar studies, providing investigators guidance on important details that can make the difference between strong and weak comparison conclusions.

Cs-137 irradiator, X-ray Irradiator, self-containe↗

The future evolution of energy-water-agriculture interconnectivity across the US

Abstract Energy, water, and agricultural resources across the globe are highly interconnected. This interconnectivity poses science challenges, such as understanding and modeling interconnections, as well as practical challenges, such as efficiently managing interdependent resource systems. Using the US as an example, this study seeks to define and explore how interconnectivity evolves over space and time under a range of influences. Concepts from graph theory and input–output analysis are used to visualize and quantify key intersectoral linkages using two new indices: the ‘Interconnectivity Magnitude Index’ and the ‘Interconnectivity Spread Index’. Using the Global Change Analysis Model (GCAM-USA), we explore the future evolution of these indices under four scenarios that explore a range of forces, including socioeconomic and technological change. Analysis is conducted at both national and state level spatial scales from 2015 to 2100. Results from a Reference scenario show that resource interconnectivity in the US is primarily driven by water use amongst different sectors, while changes in interconnectivity are driven by a decoupling of the water and electricity systems, as power plants become more water-efficient over time. High population and GDP growth results in relatively more decoupling of sectors, as a larger share of water and energy is used outside of interconnected sector feedback loops. Lower socioeconomic growth results in the opposite trend. Transitioning to a low-carbon economy increases interconnectivity because of the expansion of purpose-grown biomass, which strengthens the connections between water and energy. The results highlight that while some regions may experience similar sectoral stress projections, the composition of the intersectoral connectivity leading to that sectoral stress may call for distinctly different multi-sector co-management strategies. The methodology we introduce here can be applied in diverse geographical and sectoral contexts to enable better understanding of where, when, and how coupling or decoupling between sectors could evolve and be better managed.

Khan, Zarrar (ORCID:0000000281478553)↗

The Stanford Nanocharacterization Laboratory (SNL) and Recent Applications of an Aberration-Corrected Environmental Transmission Electron Microscope

Here, this article describes the establishment, over a period of 10 years or so, of a multi-user, institution-wide facility for the characterization of materials and devices at the nanoscale. Emphasis is placed on the type of equipment that we have found to be most useful for our users, and the business strategy that maintains its operations. A central component of our facility is an aberration-corrected environmental transmission electron microscope and its application is summarized in the studies of plasmon energies of silver nanoparticles, the band gap of PbS quantum dots, atomic site occupancy near grain boundaries in yttria stabilized zirconia, the lithiation of silicon nanoparticles, in situ observations on carbon nanotube oxidation and the electron tomography of varicella zoster virus nucleocapsids.

bio-inspired↗

In-device Battery Failure Analysis

Lithium-ion batteries are indispensable power sources for a wide range of modern electronic devices. However, battery lifespan remains a critical limitation, directly affecting the sustainability and user experience. Conventional battery failure analysis in controlled lab settings may not capture the complex interactions and environmental factors encountered in real-world, in-device operating conditions. Here, this study analyzes the failure of commercial wireless earbud batteries as a model system within their intended usage context. Through multiscale and multimodal characterizations, the degradations from the material level to the device level are correlated, elucidating a failure pattern that is closely tied to the specific device configuration and operating conditions. The findings indicate that the ultimate failure mode is determined by the interplay of battery materials, cell structural design, and the in-device microenvironment, such as temperature gradients and their fluctuations. This holistic, in-device perspective on environmental influences provides critical insights for battery integration design, enhancing the reliability of modern electronics.

36 MATERIALS SCIENCE↗

Reducing Disk Storage of Full-3D Seismic Waveform Tomography (F3DT) Through Lossy Online Compression

Full-3D seismic waveform tomography (F3DT) is the latest seismic tomography technique that can assimilate broadband, multi-component seismic waveform observations into high-resolution 3D subsurface seismic structure models. The main drawback in the current F3DT implementation, in particular the scattering-integral implementation (F3DT-SI), is the high disk storage cost and the associated I/O overhead of archiving the 4D space-time wavefields of the receiver- or source-side strain tensors. The strain tensor fields are needed for computing the data sensitivity kernels, which are used for constructing the Jacobian matrix in the Gauss-Newton optimization algorithm. In this study, we have successfully integrated a lossy compression algorithm into our F3DT SI workflow to significantly reduce the disk space for storing the strain tensor fields. The compressor supports a user-specified tolerance for bounding the error, and can be integrated into our finite-difference wave-propagation simulation code used for computing the strain fields. The decompressor can be integrated into the kernel calculation code that reads the strain fields from the disk and compute the data sensitivity kernels. During the wave-propagation simulations, we compress the strain fields before writing them to the disk. To compute the data sensitivity kernels, we read the compressed strain fields from the disk and decompress them before using them in kernel calculations. Experiments using a realistic dataset in our California statewide F3DT project have shown that we can reduce the strain-field disk storage by at least an order of magnitude with acceptable loss, and also improve the overall I/O performance of the entire F3DT-SI workflow significantly. The integration of the lossy online compressor may potentially open up the possibilities of the wide adoption of F3DT-SI in routine seismic tomography practices in the near future.

97 MATHEMATICS AND COMPUTING↗

Defining an industrial heat pump: A review & synthesis

Clear and understandable definitions of advanced energy technologies are not common and often confuse those who are not experts. This review paper addresses a critical issue in the field of heat pumps: the ambiguity surrounding the term “industrial heat pump.” The term, as discussed in various literature and media, often leads to misconceptions about the capabilities and applications of heat pumps, particularly in industrial contexts. This review paper seeks to refine and unify the definition of industrial heat pumps by analyzing existing academic and commercial literature, industry reports, and classifications. Unique identifiers explored for the definition of an industrial heat pump include the use of waste heat, operating temperature ranges, size specifications, and specific end-use applications. The study reveals differences in how industrial heat pumps are defined in academic and commercial contexts, highlighting the need for a standardized definition to facilitate better communication among manufacturers, policymakers, and end users. This is especially important considering recent legislative efforts such as the HEAT Act, which seeks to promote industrial heat pump adoption. The proposed definition aims to provide clarity while supporting the effective deployment of industrial heat pumps. With proper adoption, the definition will help promote the role of industrial heat pumps in achieving energy efficiency goals in the industrial sector. The intended impact is for the definition to serve as a foundational reference for future research and policy development.

Heat pump characteristics↗

CHARMM-GUI Bicelle Builder : An Extension of Membrane Builder for Modeling and Simulation of Bicelle Systems

Membrane mimetics, such as detergent micelles, nanodiscs, and amphipol complexes, which can provide membrane-like environments while retaining small and soluble features, have been utilized to study membrane proteins. A bicelle, composed of varying lipids and detergents, is a useful membrane mimetic because the lipid-to-detergent ratio, the q-value, can be adjusted to alter the properties of the aggregate, including the thickness and size of the bicelle. However, building a bicelle model for modeling and simulation studies requires nontrivial efforts, even for experts. We introduce CHARMM-GUI Bicelle Builder, a web-based platform that can generate various all-atom bicelle systems via a graphical user interface with all available lipids and detergents in Membrane Builder. To illustrate and validate Bicelle Builder with practical systems, we have modeled and simulated pure bicelles consisting of 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) lipids with 1,2-dihexanoyl-sn-glycero-3-phosphocholine (C6DHPC) detergents and protein–bicelle complexes, composed of DMPC with C6DHPC, foscholine-10 (FOS10), and lysophosphatidylcholine-12 (LPC12) detergents. Our simulation results indicate that Bicelle Builder can generate reliable and robust bicelle models with and without proteins that retain DMPC bilayer characteristics. Bicelle Builder is expected to help researchers better understand not only bicelles themselves but also atomistic-level structures of protein–bicelle complexes that are often difficult to access through experimental approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Asymmetric Rowland circle geometries for spherically bent crystal analyzers in laboratory and synchrotron applications

Spherically bent crystal analyzers (SBCAs) are the dominant high-resolution hard X-ray optic in the ongoing rebirth of laboratory-based X-ray absorption fine structure (XAFS) and X-ray emission spectroscopy (XES) as well as in synchrotron methods such as high energy resolution fluorescence detection (HERFD) and non-resonant X-ray Raman scattering (XRS). In the overwhelming majority of cases, SBCAs are implemented in a ‘symmetric’ configuration on the Rowland circle, wherein the diffracting crystal plane is nominally coincident with the analyzer surface. We report here comprehensive investigations of ‘asymmetric’ operation of SBCA on the Rowland circle, wherein the diffracting crystal plane is not coincident with the optical surface of the analyzer. First, we have developed a laboratory spectrometer for XAFS and XES that is specialized for asymmetric SBCA operation. Here we find several benefits, including the capacity to use a single SBCA over a very wide energy range via ‘hkl hopping’ and the frequent ability to eliminate Johann error, the most prevalent energy-broadening mechanism when using SBCA symmetrically on the Rowland circle. Second, we expand these ideas to synchrotron facilities with a demonstration study of HERFD and XRS where asymmetric operation also provided advantage. Our results suggest that large-array systems for HERFD augmented with an additional mechanical degree of freedom could streamline user operation and also indicate benefits to XRS in the asymmetric configuration, where larger solid angle, larger sample-to-detector distance, and decreased Johann error can be achieved simultaneously.

47 OTHER INSTRUMENTATION↗

Fly scan apparatus for high pressure research using diamond anvil cells

In this paper, the hardware and software used to execute fly scans at Sector 16 of the Advanced Photon Source is described. The system design and capabilities address dimensions and time scales relevant to samples in high pressure diamond anvil cells. The time required for routine sample positioning and centering is significantly reduced and, more importantly, the time savings associated with fly scanning makes it feasible for users to routinely generate two-dimensional x-ray transmission and x-ray diffraction maps. Consequently, this facilitates an important shift in high pressure research as experimentalists embrace the study of heterogeneous and minute sample volumes in the diamond anvil cell.

47 OTHER INSTRUMENTATION↗

Validity of Machine Learning in the Quantitative Analysis of Complex Scanning Near-Field Optical Microscopy Signals Using Simulated Data

Scattering-type scanning near-field optical microscope (s-SNOM) is a modern technique for subdiffractional optical imaging and spectroscopy. Over the past two decades, tremendous efforts have been devoted to modeling complex tip-sample interactions in s-SNOM, aimed at understanding the electrodynamics of materials at the nanoscale. However, due to complexities in analytical methods and the limited computation power for fully numerical simulations, compromises must be made to facilitate the modeling of tip-sample interaction, such as using quasistatic approximation or unrealistic tip geometries. Here, we apply a variety of widely utilized machine-learning methods, including k nearest neighbor and feedforward neural network etc. to study the phase-resolved spectroscopic near-field response. With only a small set of training data, which is simulated using the finite-dipole model, we demonstrate that the relation between the experimental near-field signal and sample optical constant can be one to one mapped without the need for tip modeling: for a given material with a moderate dielectric function, its complex near-field spectrum can be accurately determined within the mid-IR spectral range, and vice versa. Our preliminary study sets the stage for future exploration using real experimental data. Our method is beneficial for processing the increasing amount of data accumulated across many research groups and especially useful for user facilities such as synchrotron-based national laboratories where a large amount of data is generated on a daily basis.

36 MATERIALS SCIENCE↗

Model-based dose calculations for {sup 125}I lung brachytherapy

Purpose: Model-baseddose calculations (MBDCs) are performed using patient computed tomography (CT) data for patients treated with intraoperative {sup 125}I lung brachytherapy at the Mayo Clinic Rochester. Various metallic artifact correction and tissue assignment schemes are considered and their effects on dose distributions are studied. Dose distributions are compared to those calculated under TG-43 assumptions. Methods: Dose distributions for six patients are calculated using phantoms derived from patient CT data and the EGSnrc user-code BrachyDose. {sup 125}I (GE Healthcare/Oncura model 6711) seeds are fully modeled. Four metallic artifact correction schemes are applied to the CT data phantoms: (1) no correction, (2) a filtered back-projection on a modified virtual sinogram, (3) the reassignment of CT numbers above a threshold in the vicinity of the seeds, and (4) a combination of (2) and (3). Tissue assignment is based on voxel CT number and mass density is assigned using a CT number to mass density calibration. Three tissue assignment schemes with varying levels of detail (20, 11, and 5 tissues) are applied to metallic artifact corrected phantoms. Simulations are also performed under TG-43 assumptions, i.e., seeds in homogeneous water with no interseed attenuation. Results: Significant dose differences (up to 40% for D{sub 90}) are observed between uncorrected and metallic artifact corrected phantoms. For phantoms created with metallic artifact correction schemes (3) and (4), dose volume metrics are generally in good agreement (less than 2% differences for all patients) although there are significant local dose differences. The application of the three tissue assignment schemes results in differences of up to 8% for D{sub 90}; these differences vary between patients. Significant dose differences are seen between fully modeled and TG-43 calculations with TG-43 underestimating the dose (up to 36% in D{sub 90}) for larger volumes containing higher proportions of healthy lung tissue. Conclusions: Metallic artifact correction is necessary for accurate application of MBDCs for lung brachytherapy; simpler threshold replacement methods may be sufficient for early adopters concerned with clinical dose metrics. Rigorous determination of voxel tissue parameters and tissue assignment is required for accurate dose calculations as different tissue assignment schemes can result in significantly different dose distributions. Significant differences are seen between MBDCs and TG-43 dose distributions with TG-43 underestimating dose in volumes containing healthy lung tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-I-29: Care KV: Dose It Influence Radiation Dose in Non-Contrast Examination of CT Abdomen/pelvis?

Purpose: CARE kV is a tool that automatically recommends optimal kV setting for individual patient for specific CT examination. The use of CARE kV depends on topogram and the user-selected contrast behavior. CARE kV is expected to reduce radiation dose while improving image quality. However, this may work only for certain groups of patients and/or certain CT examinations. This study is to investigate the effects of CARE kV on radiation dose of non-contrast examination of CT abdomen/pelvis. Methods: Radiation dose (CTDIvol and DLP) from patients who underwent abdomen/pelvis non-contrast examination with and without CARE kV were retrospectively reviewed. All patients were scanned in the same scanner (Siemens Somatom AS64). To mitigate any possible influences due to technologists’ unfamiliarity with the CARE kV, the data with CARE kV were retrieved 1.5 years after the start of CARE kV usage. T-test was used for significant difference in radiation dose. Results: Volume CTDIs and DLPs from 18 patients before and 24 patients after the use of CARE kV were obtained in a duration of one month. There is a slight increase in both average CTDIvol and average DLP with CARE kV compared to those without CARE kV (25.52 mGy vs. 22.65 mGy for CTDIvol; 1265.81 mGy-cm vs. 1199.19 mGy-cm). Statistically there was no significant difference. Without CARE kV, 140 kV was used in 9 of 18 patients, while with CARE KV, 140 kV was used in 15 of 24 patients. 80kV was not used in either group. Conclusion: The use of CARE kV may save time for protocol optimization and minimize variability among technologists. Radiation dose reduction was not observed in non-contrast examinations of CT abdomen/pelvis. This was partially because our CT protocols were tailored according to patient size before CARE kV and partially because of large size patients.

60 APPLIED LIFE SCIENCES↗

Flexible and Effective Object Tiering for Heterogeneous Memory Systems

Computing platforms that package multiple types of memory, each with their own performance characteristics, are quickly becoming mainstream. To operate efficiently, heterogeneous memory architectures require new data management solutions that are able to match the needs of each application with an appropriate type of memory. As the primary generators of memory usage, applications create a great deal of information that can be useful for guiding memory management, but the community still lacks tools to collect, organize, and leverage this information effectively. To address this gap, this work introduces a novel software framework that collects and analyzes object-level information to guide memory tiering. The framework includes tools to monitor the capacity and usage of individual data objects, routines that aggregate and convert this information into tier recommendations for the host platform, and mechanisms to enforce these recommendations according to user-selected policies. Moreover, the developed tools and techniques are fully automatic, work on standard Linux systems, and do not require modification or recompilation of existing software. Using this framework, this study evaluates and compares the impact of a variety of design choices for memory tiering, including different policies for prioritizing objects for the fast memory tier as well as the frequency and timing of migration events. In conclusion, the results, collected on a modern Intel platform with conventional DDR4 SDRAM as well as Intel Optane NVRAM, show that guiding data tiering with object-level information can enable significant performance and efficiency benefits compared with standard hardware- and software-directed data-tiering strategies for a diverse set of memory-intensive workloads.

97 MATHEMATICS AND COMPUTING↗

Xanthos

Xanthos is a Python package designed to quantify and analyze global water availability in history and in future at 0.5° × 0.5° spatial resolution and a monthly time step under a changing climate. Its performance was also tested through real applications. It is open-source, extendable and convenient to researchers who work on long-term climate data for studies of global water supply, and Global Change Assessment Model (GCAM). This package integrates inherent global gridded data maps, I/O modules, Water-Balance Model modules and diagnostics modules by user-defined configuration.

Source record↗

stor4build

The EnergyPlus simulation engine supports modeling and simulation of thermal energy storage (TES) systems in several ways, including using the Python-EMS feature, which extends the operation of the engine with custom code written in Python. Creation of models using this feature can be tedious and error prone, with the connection of the model components to the Python code a particularly troublesome area. The stor4build Python package simplifies this process by modifying an input model to add a selected TES technology (implemented with the Python-EMS feature) and runs the simulation. The package leverages the OpenStudio middleware software development kit to automate this process as much as possible, eliminating potential errors and simplifying usage of EnergyPlus. The package provides objects, functions, and OpenStudio measures that implement the necessary operations to automate the creation of EnergyPlus models that integrate TES technologies with building systems. In addition, two user interfaces are provided: a command line interface and a web application programming interface. The automated process implemented by the package greatly simplifies the modeling and simulation process, allowing for parametric studies to be executed much more efficiently and effectively. The OpenStudio-based workflow is also very flexible and will allow for future additions of new technologies.

DeGraw, JasonWilliam [Oak Ridge National Laborator↗

ZFS on RBODs - Leveraging RAID Controllers for Metrics and Enclosure Management

Traditionally, the Lustre file system has relied on the ldiskfs file system with reliable RAID (Redundant Array of Independent Disks) storage underneath. As of Lustre 2.4, ZFS was added as a backend file system, with built-in software RAID, thereby removing the need of expensive RAID controllers. ZFS was designed to work with JBOD (Just a Bunch Of Disks) storage enclosures under the Solaris Operating System, which provided a rich device management system. Long time users of the Lustre file system have relied on the RAID controllers to provide metrics and enclosure monitoring and management services, with rich APIs and command line interfaces. This paper will study a hybrid approach using an advanced full featured RAID enclosure which is presented to the host as a JBOD, This RBOD (RAIDed Bunch Of Disks) allows ZFS to do the RAID protection and error correction, while the RAID controller handles management of the disks and monitors the enclosure. It was hoped that the value of the RAID controller features would offset the additional cost, and that performance would not suffer in this mode. The test results revealed that the hybrid RBOD approach did suffer reduced performance.

97 MATHEMATICS AND COMPUTING↗

Global Survey of Selected Deep Underground Facilities; Examples of Geotechnical and Engineering Capabilities, Achievements, Challenges(Mines, Shafts, Tunnels, Boreholes, Sites and Underground Facilities for Nuclear Waste and Physics R&D):A Guide

This report presents tables, references, notes, and a synthesis of some notable geotechnical and engineering information that were applied in the creation of five interactive layer maps [http://gis.inl.gov/globalsites/ will redirect to 2018 update, http://gis.inl.gov/GlobalSurvey/] for selected: 1) deep mines and shafts; 2) existing, considered or planned radioactive waste management deep underground studies or disposal facilities 3) deep large diameter boreholes, 4) physics underground laboratories and facilities, and 5) deep open pit mines from around the world. These data are intended to facilitate user access to basic information and references regarding “deep underground” facilities, history, activities, and plans. In general, the interactive maps and database provide each facility’s approximate site location, geology, and engineered features (e.g.: access, geometry, depth, diameter, year of operations, groundwater, lithology, host unit name and age, basin; operator, management organization, geographic data, nearby cultural features, other). Although the survey is not all encompassing, it is a comprehensive review of many of the significant existing and historical underground facilities discussed in the literature addressing radioactive waste management and deep mined geologic disposal safety systems. The interactive map suite allows for a better appreciation of site area geographic and cultural settings. The global survey is intended to be used as a communication tool to support and inform: 1) interested parties and decision makers; 2) radioactive waste disposal and siting option evaluations, and 3) safety case development applicable to any mined geologic disposal facility as a demonstration (examples) of historical and current engineering and geotechnical capabilities available for use in deep underground facility siting, planning, construction, operations and monitoring.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗