Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “charged”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Depth-Resolved Lithiated Gradients in Pristine and Laser-Ablated Anodes During Fast Charging

Laser ablating 3D electrode microstructures is a technique to improve Li-ion battery fast-charge performance. This technique has been theoretically proposed and electrochemically validated previously in the literature. The fundamental principle underlying laser ablation is that the ablated features reduce Li-ion transport pathways, improving access to the electrode active material near the current collector. This, in turn, promotes more homogeneous electrode utilization. The present study seeks to directly affirm the physics attributed to laser ablation using operando high-speed synchrotron X-ray diffraction. In this study, depth-resolved graphite lithiation gradients are measured operando during high-rate (15 min) charging. The depth-resolved lithiation dynamics of both ablated and non-ablated anodes are compared. The results highlight that the laser-ablated graphite electrode has notably more homogeneous utilization as compared to the non-ablated electrode. Additionally, the ablated electrode has a significant delay in reaching the maximum graphite lithiation at the separator, indicating less propensity for lithium plating. During low rate delithiation/discharge (2 hr), the two cells' lithiation gradients converge. Notably, a calibrated physics-based electrochemical model accurately reflects experimental findings, suggesting the potential to use pseudo-4D models not only to optimize laser ablation parameters in fast-charge capable electrodes but also to guide fast charging protocols that avoid lithium plating.

25 ENERGY STORAGE↗

PyChargeModel (Oriented Programming Based Electric Vehicle and Electric Vehicle Supply Equipment Charging Model in Python) [SWR-22-39]

The PyChargeModel creates two classes called "ElectricVehicles" and "evse_class", which can be used to create multiple instances of electric vehicles (EVs) and electric vehicle supply equipment (EVSE or charging ports) and simulate charging behavior. These objects can be instantiated with several properties such as battery chemistries, battery pack sizes, cell sizes, charging port power, dc or ac chargers etc. The objects can communicate with each other by calling different methods built within the classes. Through these methods, each EV object can be assigned to an EVSE, charged either using a default protocol or using setpoint values communicated from a site controller via the EVSE object.

Mishra, Partha↗

Software Control Program For Transportable Microgrid State-of-charge Balancing And Frequency Stability Controls

A deterministic state-of-charge (SOC) balancing approach software control code is introduced as an integral secondary management to primary control layer of an islanded small microgrid or nanogrid system made up of multiple grid-forming inverter/battery/solar combination systems, where each set of batteries with each inverter are on independent DC buses (i.e. non-paralleled on the DC sides). A DERMS-level control approach, algorithm and automation controller program was developed to improve coordination and enable microgrid asset compliance and SOC balancing, enabling provision of a system-level power stability support architecture, load support, and asset scalability. The architecture is configured to treat each unit or micro/nano-grid as a node in a microgrid network, allowing for autonomous DERMS control regarding load and SOC balancing and power stability. As the network grows with the addition of units, greater coordination efforts may be required. The ideal small network microgrid ranges from 2-10 inverter/battery units before additional control parameters must be considered in the existing architecture. The control approach focuses on a deterministic state-of-charge analysis as the primary level control process followed by a secondary control loop using a forced frequency-watt droop strategy to conform off-the-shelf components into behaving under a leader-follower configuration. Adopting this control scheme has been shown to allow for a balanced, unit-coordinated microgrid network, enabling stable power flow. The deterministic state-of-charge approach is introduced as an integral primary control layer of an islanded small network microgrid. A standard strategy for SOC balancing is implementing a battery management system (BMS) to control SOC on the DC side. An alternative approach is to determine how to coordinate sending and receiving power on the AC side with multiple units. The latter approach assesses all the integrated units in the microgrid network. Once the individual units are identified, further system data is required to calculate each unit's total kWh, provided information about its capability to supply or consume kWh and availability. The secondary control layer in the multi-layered small network microgrid methodology uses the primary layer’s decision to initiate frequency setpoint changes, initializing the SOC balancing. The secondary control layer considers numerous system-dependent variables to enable a charging and discharging profile based on adjustable frequency setpoints. The combined architecture will result in stable, coordinated power flow enhancing an AC microgrid's functionalities.

Myers, KurtS [Idaho National Laboratory (INL), Ida↗

Theoretical analysis of the role of complex transition dipole phase in XUV transient-absorption probing of charge migration

We theoretically investigate the role of complex dipole phase in the attosecond probing of charge migration. The iodobromoacetylene ion (ICCBr + ) is considered as an example, in which one can probe charge migration by accessing both the iodine and bromine ends of the molecule with different spectral windows of an extreme-ultraviolet (XUV) pulse. The analytical expression for transient absorption shows that the site-specific information of charge migration is encoded in the complex phase of cross dipole products for XUV transitions between the I-4 d and Br-3 d spectral windows. Ab-initio quantum chemistry calculations on ICCBr + reveal that there is a constant π phase difference between the I-4 d and Br-3 d transient-absorption spectral windows, irrespective of the fine-structure energy splittings. Transient absorption spectra are simulated with a multistate model including the complex dipole phase, and the results correctly reconstruct the charge-migration dynamics via the quantum beats in the two element spectral windows, exhibiting out-of-phase oscillations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

IOTA experiment for proton pulse compression at extreme space-charge

The longitudinal compression of intense proton bunches with strong space-charge force is an essential component of a proton driver for a muon collider. We propose a proton bunch compression experiment at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab to explore optimal radio frequency (RF) cavity and lattice configurations. IOTA is a compact fixed-energy storage ring dedicated to beam physics R&D that can circulate a 2.5-MeV proton beam with extreme space-charge. Using ImpactX and its 3D space-charge solver, simulations indicate that bunch length can be rapidly reduced by a factor of at least two, without appreciable degradation in transverse beam quality, even under strong space-charge conditions. However, longitudinal defocusing presents a large effect in short-pulsed proton beams, and the optimization of bunch compression under such conditions is discussed.

Simons, Benjamin [Northern Illinois U.; Fermilab]↗

Space charge studies on strong hadron cooler energy recovery linac

An Energy Recovery Linac (ERL) based cooler, using Coherent electron Cooling (CeC) is being designed for cooling hadron beams of the Electron-Ion Collider (EIC). The ERL design utilizes highcurrent, high-brightness electron beams with low emittance and a uniform longitudinal distribution for efficient hadron cooling. This is designed to operate in two modes to accommodate cooling requirements for hadron bunches at 100 GeV and 275 GeV, each with an average current of 100 mA and 1 nC bunch charge. With these parameters, the space charge effects become significant in this ERL design due to the low beam energy and high beam current. In this paper, we discuss strategies for including space charge effects in the optics design and implementation of an interface for space charge dominated and non-dominated regions of this ERL lattice.

Accelerator Physics↗

Federal Workplace Charging Program Guide

This report serves as a program guide to support federal agencies in developing their own policy documents for workplace charging. It provides suggested language that agencies can incorporate into their own policies to define requirements for charging privately owned vehicles (POVs) on government-owned or leased property. The Fixing America's Surface Transportation Act authorizes the U.S. General Services Administration (GSA) and other federal agencies to install, operate, and maintain electric vehicle supply equipment (EVSE) for POVs in parking areas used by federal employees and authorized users, and it requires the collection of fees to recover the costs of installing, operating, and maintaining this equipment. This guide offers details for agency facility managers, transportation personnel, employees, and vendors regarding the charging of electric vehicles (EVs) for use by employees and personnel at government-owned and leased buildings. This guide describes the requirements associated with federal agencies providing EV charging in publicly accessible sites. The policy also describes when and how fees may be imposed to cover costs of electricity, as well as EVSE units and installations in various scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Federal Workplace Charging Program Guide

The 2015 Fixing America's Surface Transportation (FAST) Act authorizes the installation, operation, and maintenance of electric vehicle supply equipment (EVSE) for the purpose of recharging employees' privately owned vehicles (POVs) under the custody or control of the General Services Administration (GSA) or a Federal agency. It requires the collection of fees to recover the costs of installing, operating, and maintaining this equipment and imposes reporting requirements. This program guide reviews those requirements, excerpts the relevant language in Appendix A, and describes when and how fees may be required to cover costs of electricity, network costs, EVSE units, and installations in various scenarios. This program guide is designed to support Federal agencies developing and refining workplace charging programs for employee POVs. While it provides guidance and best practices, it does not replace agencywide policies or agency-specific legal counsel. It contains a roadmap for agency workplace charging programs and defines roles and responsibilities. This guide explains how to determine the number of POVs likely to charge at a given site and contains a sample employee survey in Appendix B. It reviews EVSE planning, including unit selection and acquisition, charger location(s), accounting for available power capacity, using existing infrastructure, and funding an incentive program. It also discusses the costs associated with EVSE acquisition, installation, and network management. These costs inform the subsequently provided information, which describes how to amortize costs to determine appropriate fees for each charging session. The final two sections of this guide address aspects of ongoing program management that the facility coordinator should consider and the reporting requirements associated with the FAST Act. The insights in this guide are applicable to all agency-owned and GSA-leased buildings or facilities offering the use of EVSE or a 120-volt receptacle for the purpose of recharging an employee's POV. However, the FAST Act requirements typically do not apply to any building or facility operated and maintained by a third-party vendor offering the use of EVSE as part of a commercial building lease unless the agency is managing the station and/or energy on behalf of the building and collecting POV fees.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Redox-Hopping-Based Charge Transport Mediated by Ru(II)-Polypyridyl Species Immobilized in a Mesoporous Metal-Organic Framework

Electronic charge transport through crystalline metal-organic frameworks (MOFs) can be accomplished by site-to-site electron (or hole) hopping, provided that redox-active sites, such as easily reducible or oxidizable MOF linkers, are present. If the framework itself is redox-inert, solvent-assisted ligand incorporation of redox-active moieties can serve to enable hopping-based charge transport. Here we have studied the redox hopping process within Ru-bpy@NU-1008, where Ru-bpy is a carboxylate-functionalized derivative, i . e ., a node-ligating derivative, of the well-known chromophore Ru(2,2′-bipyridine) 3 2+ , and NU-1008 is a redox-inert MOF featuring hierarchical porosity and csq topology. Chronoamperometry experiments with electrode-supported thin films of Ru-bpy@NU-1008 show that charge transport is feasible through portions of the MOF, with other portions being inaccessible. Possible confounding features are the undersized c- pores that cross-connect 1D mesoporous channels, as ingress and egress of charge-compensating anions is believed to accompany the net oxidation of Ru(II) to Ru(III) and the reduction of Ru(III) to Ru(II). Phenomenologically, transport through the electroactive portion of the films is diffusion-like, with the magnitude of the apparent diffusion coefficient being 6 × 10 −12 cm 2 /s.

Duan, Jiaxin↗

Superconductivity from Charge Order in Cuprates

Superconductivity in layered cuprates is induced by doping holes into a parent antiferromagnetic insulator. It is now recognized that another common emergent order involves charge stripes, and our understanding of the relationship been charge stripes and superconductivity has been evolving. Here we review studies of 214 cuprate families obtained by doping La 2 CuO 4 . Charge-stripe order tends to compete with bulk superconductivity; nevertheless, there is plentiful evidence that it coexists with two-dimensional superconductivity. This has been interpreted in terms of pair-densitywave superconductivity, and the perspective has shifted from competing to intertwined orders. In fact, a new picture of superconductivity based on pairing within charge stripes has been proposed, as we review.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation program for secondary spacecraft cells: Evaluation of storage methods, open circuit versus continuous trickle charge, Sonotone 3.5 ampere-hour sealed nickel-cadmium secondary spacecraft cells

Twenty-five cells were used in a five-year test to compare, after each successive one-year storage period, the discharge and charge characteristics of charged cells on open circuit versus that of cells on continuous trickle charge. The test procedure, instrumentation, and results are described. Based on the test results, the following recommendations were made: (1) If the user's purpose will allow a rejuvenation cycle or two after a long storage period, the open circuit regime will likely give slightly greater capacity. (2) If the user's purpose demands immediately available power following a long storage period, the trickle charge method of storage is definitely the regime to use.

Thomas, R. E.↗

Population inversion calculations using near resonant charge exchange as a pumping mechanism

Near resonance charge exchange between ions of a large ionization potential gas such as helium or neon and vapors of metals such as zinc, cadmium, selenium, or tellurium has produced laser action in the metal ion gas. The possibility of obtaining population inversions in near resonant charge exchange systems (Xe-Ca, Xe-Mg, Xe-Sr, Xe-Ba, Ar-Mg, N-Ca) was investigated. The analysis is an initial value problem that utilizes rate equations for the densities of relevant levels of the laser gas (Ca, Ba, Mg, or Sr) and an electron energy equation. Electron excitation rates are calculated using the Bohr-Thomson approximation for the cross section. Approximations to experimental values of the electron ionization cross section and the ion-atom charge exchange cross section are used. Preliminary results have been obtained for the Ca-Xe system and show that it is possible to obtain gains greater than 10 to the 14th power/m with inversion times up to 8x10 to the minus 7th power second. A possible charge exchange laser system using a MPD arc plasma accelerator is also described.

Chubb, D. L.↗

Space-charge dynamics of liquids.

The propagation and instability characteristics of small-signal electro-fluid-mechanical space-charge and polarization waves in nonhomogeneous fluids are developed. Stratified equilibrium configurations with fluid properties and space-charge density constant within planar, cylindrical, and spherical surfaces, are emphasized. Equilibrium electric fields due both to charges in the fluid and to externally imposed potentials are normal to these surfaces. The liquid is modeled as incompressible, inviscid, and perfectly insulating, with domains of sufficiently high frequency or growth rate to validate the last assumption defined in terms of electrical conductivity or mobility. A general set of relations for perturbation field and flow variables on the perturbed surfaces of fluid layers having constant properties and space charge are derived in each of the configurations.

Zahn, M.↗

Rechargeable, silver-zinc battery conditioner/monitor unit and state-of-charge indicator

Unit automatically charges batteries to desired state-of-charge levels, monitors functional battery parameter data both on meters and printer, and automatically activates alarm in event of battery malfunctions. Unit consists of state-of-charge indicator panel, control panel, monitor panel, power panel, charging-current power supply, and load panel.

Thomas, C. E.↗

Characterization of charge states of energetic ions in solids from associated K X-ray production

The strong projectile-charge-state dependence of K X-ray production in gases establishes a charge-state scale for ions penetrating solids. Si K X-ray cross sections in gaseous SiH4 were compared to those in solid Si for 40-MeV O (6+ to 8+) and 86-MeV Ar (6+ to 16+) projectiles. For Ar an effective charge of 11 plus or minus one is found compared to an emergent charge of 14.8 plus or minus 0.5. The result is discussed in terms of alternate models for steady-state excitation in solids.

Datz, S.↗

A study of the interaction of neutral and charged particles

Preliminary experimental data on the number of charged neutral nuclear-active particles were obtained at 200 BeV. The ratio of the number of charged particles to the number of neutral particles was 2.1 + or - 0.3. Nuclear cascade curves in iron and distributions over the portions of energy transferred to neutral pions in lead were obtained for avalanches generated by charged and neutral particles. The characteristics of interactions of the charged neutral particles at the existing experimental errors showed no difference.

Kim, V. M.↗

Development of environmental charging effect monitors for operational satellites

An instrumentation package to monitor the effects of the environmental charging of spacecraft surfaces on the systems of operational spacecraft was developed. This package performs two functions: first, the local charged particle flux and the particle characteristic energy is monitored; and second, transients in the spacecraft electrical harness is counted as a function of amplitude, with time. It is used to determine the duration and effect of any environmental charging of the spacecraft surfaces. Thus, it will be possible to determine the relationship between the occurrence of any anomalies and the charging phenomenon. Design details and design goals of this package are presented.

Stevens, N. J.↗

Charge coupled device integration-time coding for detection of images moving with unknown velocities

Existing techniques for the detection of a moving low light level image by a CCD array have required velocity synchronism between the image and the photogenerated charges. This was necessary to prevent blurring during the long duration of charge integration. A new detection scheme is described which causes the image to be convolved with a clock modulation signal as the photocharges are collected. The charge accumulating from each image point will now be spread over many photoelements due to the absence of velocity synchronism, but the output is not blurred in the usual sense. Instead the charge is distributed through the array in a controlled way so that the image can be reconstructed.

White, J. M.↗